PubMed HealthSearch

Biomedical subjects

M G Sampson

Publications and source records attributed to M G Sampson.

7 recordsLinked to original sources

Operative management of greater saphenous thrombophlebitis involving the saphenofemoral junction.

Forty-three consecutive patients with greater saphenous vein (GSV) thrombosis extending to the saphenofemoral junction (SFJ) were treated. Twenty-three patients had extension of thrombus into the common femoral vein (CFV). Twenty patients had thrombus extending to but not within the CFV. Symptoms, risk factors, and physical examination were not predictive of CFV thrombus extension. When compared with the operative record, duplex scans accurately located the extent of the thrombosis 100% of the time. Forty-one surgical procedures were performed. No patients had pulmonary emboli during the procedures. Thirty-seven patients were treated as outpatients or were discharged within 3 days of their surgical procedures. The two patients who did not undergo operative procedures in this series had complete occlusion of the CFV with extension into the external iliac vein. Thrombus within 3 cm of the SFJ is an indication for surgical intervention. Disconnection of the GSV from the CFV prevents extension of the thrombus, and a limited CFV thrombectomy can be performed when necessary. This is considerably more cost-effective than treatment with anticoagulation.

Adult

Venous and arterial anomalies of the lower extremities diagnosed by duplex scanning.

The complex embryologic development of the vascular system often results in a myriad of clinically relevant anomalies. It has been stated that the classic anatomic venous pattern in the lower extremity is found in only 16 percent of patients. Previous studies on this topic are limited to isolated venous dissections or phlebography that lack complete anatomic detail. The recent introduction of high resolution duplex scanners for the assessment of veins of the lower extremity provides a unique opportunity to determine the incidence of anatomic variation. The current prospective study was done to identify venous or arterial anomalies apparent during routine duplex scanning of the lower extremity performed to rule out deep venous thrombosis (DVT). Limbs that had evidence of acute or chronic extensive DVT were excluded. Of 1,600 consecutive extremity scans, 946 extremities (59 percent) had no evidence of DVT. Of these, there were 43 patients with 64 anomalies in 57 extremities. The mean age of the group was 53.4 years. There were 24 women (55.8 percent) and 19 men (44.2 percent). There were 59 (92.2 percent) venous and five (7.8 percent) arterial anomalies. Duplication of the superficial femoral vein was the most common anomaly noted. Duplication of the deep femoral and popliteal vein was also noted. Unilateral anomalies were more common than bilateral anomalies, namely 67.4 versus 32.6 percent, respectively. Pain and swelling, common complaints in the patients with an anomaly, were noted in 71.4 and 45.7 percent, respectively. The frequency of deep venous anomalies of the lower extremities may be less than previously reported. Knowledge concerning the incidence and distribution of venous anomalies may lead to improved assessment and treatment of venous disease.

Adult

Upper extremity venous duplex imaging.

Over 500 upper extremities have been imaged with the Duplex Scanner at the John J. Cranley Vascular laboratory. Venous anatomy and imaging techniques are presented. Reference points and zones for localizing abnormal findings are demonstrated. Abnormal venous pathology including case presentations of acute radial, basilic, cephalic, and axillary vein thrombosis are presented. Complications of subclavian and internal jugular vein catheterization are demonstrated. Soft tissue pathology including edema, lymphadenopathy, hematomas, cysts, and abscesses are visualized and differentiated. Duplex use for evaluation of aneurysm, pseudo aneurysm and graft surveillance has been increasing in frequency. Examples are demonstrated.

Arm

Measurement of blood flow rates in the lower extremities with use of a nuclear magnetic resonance based instrument.

Direct, noninvasive measurement of pulsatile blood flow to the human extremity is now possible by means of a flow measurement instrument that is based on the principles of nuclear magnetic resonance. The instrument uses a physically independent calibration module as a primary calibration standard. Volumetric calibration of this module indicates that it is precise and accurate over the range of 0 to 100 ml/min. The calibration module is used, in turn, to calibrate an electromagnetic flow sensor that is incorporated into the instrumentation. The calibration module and the electromagnetic sensor were found to be linearly related over the range of 5 to 100 ml/min, with a regression correlation coefficient of 0.996. The calibrated electromagnetic flow sensor is used as a secondary standard for calibration of the nuclear magnetic resonance sensor. Blood flow measurements, obtained by use of this method, agree closely with those obtained by plethysmographic methods. They differ from the plethysmographic results in that magnetic resonance flows will distinguish between the at-rest blood flow in the normal extremity and the flows seen in the extremity (also at rest) with claudication. Based on the results obtained from studying a limited number of limbs with a high degree of ischemia, the method will not distinguish the limb with ischemia from the limb with claudication. Limitations of the method and refinements required to make the method clinically useful are discussed.

Adult

Superficial thrombophlebitis diagnosed by duplex scanning.

Since July 1982, this noninvasive vascular laboratory has performed 12,856 lower extermity venous duplex examinations. All cases of acute venous thrombosis have been categorized and entered into a computer data base. One thousand four hundred twelve examinations were positive for acute venous thrombosis. This report analyzes the laboratory's entire experience with superficial thrombophlebitis (SVT). One hundred eighty-six patients were diagnosed by duplex scanning to have SVT. Women outnumbered men 99 to 87. They were slightly older (average age 58.4 +/- 16.2 years) compared with the men (53.8 +/- 14.2 years). Men were more likely to have a complicated course of SVT (40% vs 22%; p less than 0.01). Complications included either radiographically documented pulmonary embolism or deep venous involvement. Fifty-seven (31%) patients had at least one complication of SVT. A series of predisposing factors was analyzed and six factors were associated with an increased risk of complications. They are bilateral SVT (p less than 0.01), age greater than 60 years (p less than 0.01), male sex (p less than 0.01), history of deep venous thrombosis (p less than 0.01), bed rest (p less than 0.02), and presence of infection (p less than 0.02). Location of thrombus within the greater saphenous vein (35%) was most likely to be associated with complications. Isolated varicosities (8%) were least likely to be associated with complications. Duplex scanning identifies a significant number of complications of patients with SVT and should be obtained in cases of saphenous vein involvement or in the presence of associated risk factors.

Aged

Upper extremity venous thrombosis diagnosed by duplex scanning.

The incidence of axillary-subclavian venous thrombosis continues to rise, while reports of noninvasive methods to diagnose this condition have been sparse. A review of the records of 693 consecutive upper extremity duplex scans was performed, and a diagnosis of acute venous thrombosis was made in 123 of these patients. Of these, 85 involved the axillary or subclavian vein. Use of a central venous catheter was the most common risk factor for axillary-subclavian venous thrombosis. Within this group, 8% had a pulmonary embolism, of which 25% were fatal. Follow-up of patients with axillary-subclavian venous thrombosis at a mean of 2 years revealed that 49% of these patients had died. Of the remaining patients, more than one third had evidence of the post-thrombotic syndrome. Duplex scanning of the venous system provides a safe, reliable, and repeatable method of evaluating and following patients with suspected venous thrombosis of the upper extremity.

Acute Disease

Voluntary breath holding in the obese.

Alveolar gas tensions and arterial O2 saturation (Sao2) during a voluntary breath hold at functional residual capacity (FRC) were examined in 13 healthy seated subjects. An excellent correlation (r = 0.80) was found between the fall of alveolar O2 tensions (delta PETo2) and body weight, expressed as the ratio of weight to height (wt/ht, kg/cm). An even greater correlation (r = 0.89) was found between delta PETo2 and the ratio of breath-hold time X O2 consumption/FRC. Alveolar Po2 decreased to 70 mmHg in the obese group after just 15 s of apnea, whereas this degree of hypoxia did not occur in the nonobese until the breath hold was sustained for 30 s. This variable rate of fall of alveolar Po2 during a breath hold can be ascribed to the changes of O2 consumption (Vo2) and FRC associated with changing body weight. In the obese, Vo2/FRC was twice as large as in the nonobese, thus accounting for the differences of breath-hold time needed to obtain the same alveolar Po2. Sao2 measured at the end of the breath hold was the same as that value predicted from the reduction of PETo2. This suggests that the fall of alveolar Po2 can entirely account for the observed fall of O2 saturation and that venous admixture had not increased during the 15-s apnea. In patients with sleep apnea, the ratio of Vo2/(initial lung volume) may also be an important determinant of the severity of hypoxemia observed.

Apnea