UNLABELLED: Benign acute pericarditis is a common disorder. Although, at first glance, its management appears well defined, the guidelines issued by professional societies with respect to optimal treatment and length of its administration remain vague. METHODS: a brief, anonymous questionnaire probing into treatment practices was sent in April 2005 to all cardiologists of Brittany. RESULTS: we collected 164 analyzable questionnaires out of 248 submitted (66%). The initial investigations in presence of acute pericarditis included an electrocardiogram in 100% of cases, an echocardiogram in 95%, and screening biochemistry in 93% of cases. Systematic hospitalisation was advised by only 24% of cardiologists. Aspirin was prescribed as first choice treatment in 92.5% of cases. Duration of treatment recommendations varied widely, from <5 days by 2.5%, between 5 and 10 days by 25.5%, 11 and 15 days by 23.0%, 16 to 21 days by 35.3%, and for >21 days by 14% of cardiologists. Hospital-based cardiologists were more likely to systematically hospitalise their patients than outpatient practice-based physicians (79.5% versus 5.1%; p<0.001) as well as to order an initial biochemical screening tests (100% versus 81.4%, p<0.01). Cardiologists <42 years of age recommended significantly fewer hospitalisations than older physicians (6.8% versus 36.4%: p<0.001). CONCLUSIONS: the management of acute, benign pericarditis was limited nearly exclusively to the prescription of aspirin. Duration of treatment varied widely. These observations are concordant with data published in the literature (where the recommended duration of treatment is systematically missing).
During 2005, the evolution of interventional cardiology has largely been dominated by the trial of active endoprostheses, whose advantage has been consistently shown by various studies, mete-analyses and surveys. Extending their use to new indications and evaluating new drugs have also been studied. In parallel, clinical trials have been performed in the promising field of percutaneous treatment of valvular heart disease, particularly mitral insufficiency and calcified aortic stenosis in the adult.
OBJECTIVE: To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography. PATIENTS AND METHODS: 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 x 0.75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/s). Two independent blinded reviewers analysed the MSCT. RESULTS: 143 patients had previous stenting (232 stents) and 190 (82%) of the 232 stents were detected. Intrastent lumen was interpretable in 126 (64%) of the detected stents. Lumen interpretability depended on stent diameter: for stent diameter > 3 mm, 81% of lumens were interpretable, as against 51% with < or = 3 mm stent diameter (p < 0.001). Restenosis detection likewise depended on stent diameter: with small stents (< or = 3 mm), sensitivity and specificity of MSCT were 54% and 100%, respectively; positive and negative predictive values were 100% and 94%. For stents with > 3 mm diameter, corresponding values were 86%, 100%, 100%, and 99%. CONCLUSION: 16 slice MSCT allows analysis of in-stent lumen in about half of all stented angioplasties. It performs better when stent diameter is more than 3 mm and may offer a non-invasive alternative to conventional coronary angiography for monitoring stented coronary arteries. Technical progress may improve interpretability and hence increase the yield of MSCT in this application.
The aim ot tnis study was to assess the results of interventional strategy in patients over 75 years of age admitted to hospital with acute coronary syndromes (ACS) without persistent ST elevation. Over three months, patients over the age of 75 undergoing coronary angiography for ACS were included in a multicentre register and followed up for 6 months. A total of 126 patients with an average age of 79 were included: 70% had at least one poor prognostic factor. The treatment on admission included: Aspirin (84%), Clopidogrel (60%), anti GpIIb-IIIa (12%) and Heparin (81%, of which 3/4 of cases were low molecular weight heparins). Coronary angiography (average delay 80 hours) showed single, double and triple vessel disease in 21, 29 and 35% of cases respectively. Coronary angioplasty was proposed in 83 patients and carried out in 82. Eleven patients underwent coronary artery bypass grafting and 31 were treated medically. During the hospital phase, there were 3 major cardiovascular complications: 1 death during coronary angiography, 1 intra-stent thrombosis and 1 death in the group undergoing bypass grafting, with no major bleeding complications. At 6 months, there were 8 (6.5%) major cardiovascular adverse events with 6 in the "angioplasty" group; 5 deaths (3 cardiac deaths), 3 myocardial infarcts. Two thirds of patients were asymptomatic. The authors conclude that interventional strategy in ACS of elderly patients is associated with a low rate of major adverse events. The benefits of this strategy should be confirmed by randomised trial.
Explore the source record for details and available documents.
UNLABELLED: Left ventricular-based pacing is an established method for treatment of congestive heart failure in patients with ventricular dyssynchrony. The transvenous epicardial approach is the method of choice to pace the left ventricle. AIMS: To evaluate short and long-term stability and pacing and sensing performance of an S-shaped non-steroid unipolar lead. METHODS: Forty-eight procedures were performed in 43 consecutive patients (mean age: 70+/-8 years, 32 males) with severe congestive heart failure. The left ventricular lead was placed into a coronary sinus tributary. Pacing and sensing thresholds and pacing impedance were measured at implant, 1 and 6 months. RESULTS: The mean procedure time was 90.0+/-35.5 min. Pacing thresholds at implant, 1 and 6 months were 1.1+/-0.8 V, 1.9+/-1.3 V and 1.9+/-1.5 V respectively. In 7 patients, lead implantation was unsuccessful. One of them had a successful second attempt. Lead revision was performed in 5 patients for loss of capture. CONCLUSION: The S-shaped unipolar lead evaluated in this study provides stable long-term position and pacing thresholds. Recent improvement of this S-shaped lead model will hopefully reduce the rate of implantation failures and acute dislodgements.
We report a documented observation of coronary thrombosis occurring in a 25-year-old patient with no risk factor, presenting a hereditary thrombophilia (facteur V Leiden) diagnosed a few months earlier in a context of venous thrombosis. This patient had a spread out anterior myocardial infarction with cardiac arrest due to a ventricular fibrillation; although he was quickly rescued by the mobile intensive Care Unit, the patient died 48 hours later, after cerebral anoxia. The mutation called factor V Leiden is a widely spread hereditary family thrombophilia (5 to 6% of the population) and is characterized by a resistance to activated C protein provoking a hypercoagulable state. The unexpected arterial thrombosis, very rare in that case, can be extremely serious and raises the question of a preventive medication such as antiplatelet agent or low-molecular-weight heparin as soon as the genetic abnormally has been proved to be symptomatic.
This is a case-report of two patients with superior vena cava syndrome related to pacemaker leads. Both patients were treated successfully using intravenous stenting.
BACKGROUND: Stenting has been demonstrated to be superior to balloon angioplasty in de novo focal lesions located in large native vessels. However, in small vessels, the benefit of stenting remains questionable. METHODS AND RESULTS: A total of 381 symptomatic patients with de novo focal lesion located on a small coronary segment vessel (<3 mm) were randomly assigned to either stent implantation (192 patients; 197 lesions) or standard balloon angioplasty (189 patients; 198 lesions). The primary end point was the angiographic restenosis rate at 6 months, as determined by quantitative coronary angiography. On intention-to-treat analysis, angiographic success rate and major adverse cardiac events were comparable: 97.9% and 4.6% versus 93.9% and 5.8% in the stent group and the balloon group, respectively. After the procedure, a larger acute gain was achieved with stent placement (1.35+/-0.45 versus 0.94+/-0.47 mm, P=0.0001), resulting in a larger minimal lumen diameter (2.06+/-0.42 versus 1.70+/-0.46 mm, P=0.0001). At follow-up (obtained in 91% of patients), angiographic restenosis rate was 21% in the stent group versus 47% in the balloon group (P=0.0001), a risk reduction of 55%. Repeat target lesion revascularization was less frequent in the stent group (13% versus 25%, P=0.0006). CONCLUSIONS: Elective stent placement in small coronary arteries with focal de novo lesions is safe and associated with a marked reduction in restenosis rate and subsequent target lesion revascularization rate at 6 months.
OBJECTIVE: The purpose of this study is to report prospectively the results of six-month follow-up of permanent left ventricular (LV) based pacing in patients with severe congestive heart failure (CHF) and left bundle branch block (LBBB). BACKGROUND: Left ventricular pacing alone has been demonstrated to result in identical improvement compared to biventricular pacing (BiV) during acute hemodynamic evaluation in patients with advanced CHF and LBBB. However, to our knowledge, the clinical outcome during permanent LV pacing alone versus BiV pacing mode has not been evaluated. METHODS: Pacing configuration (LV or BiV) was selected according to the physician's preference. Patient evaluation was performed at baseline and at six months. RESULTS: Thirty-three patients with advanced CHF and LBBB were included. Baseline characteristics of LV (18 patients) and BiV (15 patients) pacing groups were similar. During the six-month follow-up period, seven patients died three BiV and four LV). In the surviving patients at 6 months, 8 of 14 patients in the LV group and 9 of 12 in the BiV group were in New York Heart Association class I or II (p = 0.39). No significant difference was observed between the two groups in terms of objective parameters except for LV end-diastolic diameter decrease (-4.4 mm in BiV group vs. -0.7 mm in LV group; p = 0.04). CONCLUSION: At six-month follow-up, a trend toward improvement was observed in objective parameters in patients with severe CHF and LBBB following LV-based pacing. The two pacing modes (LV and BiV) were associated with almost equivalent improvement of subjective and objective parameters.
BACKGROUND: Beneficial effects of left ventricular (LV)-based pacing on acute hemodynamic parameters were reported in several series, but only a few studies examined the long-term effects of this new pacing procedure. AIMS: To assess long-term effects of permanent LV-based pacing on LV function and mitral regurgitation (MR) in patients with refractory congestive heart failure (CHF). METHODS: A prospective evaluation of LV function and MR was performed in 23 patients with severe but stable CHF and left bundle branch block (mean QRS: 186+/-31 ms) by radionuclide and echocardiographic techniques at baseline and 6 months after implantation of a permanent LV-based (LV alone: 13 patients; biventricular: 10 patients) pacemaker programmed either in a DDD mode (sinus rhythm; n=14) or in a VVIR mode (atrial fibrillation; n=9). RESULTS: Compared to baseline, the 6 months follow-up visit demonstrated a significant increase in radionuclide derived LV ejection fraction from 23.3+/-7 to 26.2+/-7% (P<0.01) and in echocardiographic LV fractional shortening from 13+/-4 to 16+/-6% (P<0.05), without any change in cardiac index, a significant decrease in LV end-diastolic diameter (from 73.2+/-6 to 71.2+/-7 mm; P<0.05), end-systolic diameter (from 63.6+/-6 to 60.2+/-8 mm; P<0.05) and color Doppler MR jet area (from 11.5+/-6 to 6.6+/-4 cm(1); P<0.001). A comparison of patients with LV pacing alone and patients with biventricular pacing showed similar beneficial effects of pacing on MR severity in the two subgroups and a non-significant trend for a better improvement of LV function during biventricular pacing. CONCLUSION: Thus, in patients with severe CHF and left bundle branch block, permanent LV-based pacing may significantly improve LV systolic function and decrease MR.
AIMS: Assessment of complications following implantation of transvenous ventricular electrodes to pace the left ventricle. METHODS AND RESULTS: Twenty-eight patients with severe cardiac failure and left bundle branch block were prospectively followed for adverse effects of implantation of a left ventricular transvenous pacing system. Immediate follow-up was associated with loss of left ventricular pacing in nine patients (32%). This was due to lead dislodgement in four cases (corrected by re-operation in three of these cases), and due to increased threshold in five cases (corrected by programming a higher pacing amplitude in all five cases, but with intermittent diaphragmatic contraction in one case). After 1 month, one patient died, one patient with severe coronary heart disease suffered a myocardial infarction, and left ventricular pacing was lost in two patients. Pericardial effusion, new significant ventricular arrhythmias or other adverse effects were not observed. After a mean follow-up of 16 +/- 9.2 months, pacing leads remained stable and no late complications related to the transvenous left ventricular epicardial pacing were observed. CONCLUSION: Placement of a permanent lead in a tributary of the coronary sinus is feasible without serious adverse effects during the first month. The only frequent adverse event was lead dislodgement; a finding which emphasizes the need for development of specially designed leads for this application.
BACKGROUND: The SWIBAP (stent without balloon predilatation) prospective randomised trial was designed to compare direct coronary stenting with stenting preceded by lesion predilatation with an angioplasty balloon. OBJECTIVE: To determine the feasibility and safety of direct stenting in non-complex coronary lesions in a prospective study. PATIENTS AND DESIGN: All patients < 76 years of age scheduled to undergo angioplasty of a non-complex, non-calcified lesion in a coronary artery of > 3.0 mm, who granted their informed consent, were randomised into the trial. In group I, the stent was placed without balloon predilatation, while in group II stent implantation was preceded by balloon predilatation. The primary end point was the angiographic result according to procedure assigned by randomisation. An intravascular ultrasound substudy was performed in 60 patients. RESULTS: Stent implantation was successful without predilatation in 192 of the 197 group I patients (97.5%), and with predilatation in 197 of the 199 group II patients (99%) (NS). No in-hospital stent thrombosis or death occurred. Overall procedural times, fluoroscopy times, and volumes of contrast agent given (mean (SD)) in group I v group II were 23.50 (13.54) min v 27.96 (15.23) min (p = 0.002), 6.04 (4.13) min v 6.67 (3.65) min (NS), and 135 (65) ml v 157 (62) ml (p < 0.001), respectively. No major adverse cardiovascular events had occurred by 30 days. CONCLUSIONS: The feasibility and safety of direct stenting of selected and non-complex coronary lesions is confirmed. This technique was as successful as the conventional approach and was associated with a minor reduction in fluoroscopic exposure and procedure time and the administration of less contrast agent.
The aim of this study was to evaluate the clinical events occurring after coronary stenting in a series of 318 consecutive patients treated in 1997. Hospital follow-up was by gathering all the data in the hospital record and medium-term follow-up was performed by questionnaire filled with the help of the patient, the attending physician and the referring cardiologist. The primary clinical success rate was 95.6% and the clinical follow-up rate was 98.7%. The follow-up period was at least 16 months (mean 22 +/- 6 months). The restenosis rate was 15% in the remaining population (318-7 deaths and 4 lost to follow-up) and 47% in the population undergoing control coronary angiography. No major clinical cardiac events (death, myocardial infarction or revascularisation) were observed in 80.5% at 1 year and 79% at 22 months. Twenty per cent of the remaining population had no non-invasive paraclinical investigations for myocardial ischaemia after coronary stenting. These results are comparable to those of the literature, indicating excellent feasibility of this technique and the fact that, programmed or not, coronary stenting is a safe procedure confirming its value in what has become everyday practice. Nevertheless, this experience did highlight certain lapses in medical follow-up and patient information.
The aim of this study was to assess the impact of cardiovascular risk factors on the modelling of atherosclerotic coronary arteries. One hundred consecutive patients who underwent coronary angioplasty were studied by endocoronary ultrasonography at the site of dilatation. At the site of the treated stenosis of the dilated arteries there was either compensatory widening or positive modelling (PM), or focal contraction or negative modelling (NM) if the total surface area (TSA) of the artery at the site of dilatation was greater or smaller than the total surface area of the proximal or distal reference segments. PM was observed in 53 cases (53%) and NM in 47 cases (47%). Lesions with NM had smaller TSA (13.7 +/- 5.8 versus 20.8 +/- 6.4 mm2, p < 0.0001) and a smaller atheromatous plaque (11.8 +/- 5.6 versus 19.1 +/- 6.5 mm2, p < 0.0001) than lesions with PM. Cardiovascular risk factors such as hypercholesterolaemia, smoking and hypertension were not predictive of either form of arterial modelling and there was no relationship between the cardiovascular risk factors and the qualitative appearances of the plaque studied.
SEARCH FOR AN ALTERNATIVE TREATMENT: The concept of stimulating the ventricle to improve heart function in patients with severe heart failure is an old one, but the first published series was reported about 10 years ago and provided encouraging results that lead to numerous other studies. A PROMISING TECHNIQUE: Excepting a few patients with a long PR, stimulation of the right ventricle is ineffective or even deleterious. Stimulation of the lateral region of the left ventricle has produced some undeniably favorable and sometimes even spectacular improvement in hemodynamic performances. Permanent stimulation of both ventricles or the left ventricle produces an overall clinical improvement in patients with severe heart failure (NYHA III or IV) and major left intraventricular conduction disorders (QRS > 140 ms). These results have been recently confirmed in a prospective randomized trial. CAREFUL OPEN QUESTIONS: There is no fully satisfactory explanation for the improvement which, it is important to note, does not occur in all patients. A more homogeneous contraction of the left ventricle certainly plays a fundamental role. Resynchronization of the two ventricles with dual stimulation is more complex and costly and remains to be evaluated. One crucial question is currently being examined: what is the effect of stimulation on the high mortality in these patients?
Internal mammary artery-to-venous fistulas represent a rare cause of a continuous precordial murmur that may be confused clinically with a patent ductus arteriosus. The acquired variety may be secondary to inflammatory, neoplasic, or traumatic events. A congenital fistula may occur as an isolated event, as in the present case, and the question of advisability of endovascular treatment for this patient remains unanswered.