PubMed HealthSearch

Biomedical subjects

M Goitein

Publications and source records attributed to M Goitein.

At least 19 recordsLinked to original sources

3D treatment planning for heavy charged particles.

The comments herein describe, at a necessarily superficial level, a number of issues which must be addressed in developing plans for heavy charged particle therapy. Programs now exist which provide the needed capabilities. The challenge now is to make the planning process easier and faster--and possibly more effective. It seems likely that this will be achieved in the next few years.

Equipment Design

A dose response analysis of injury to cranial nerves and/or nuclei following proton beam radiation therapy.

The low tolerance of the central nervous system (CNS) limits the radiation dose which can be delivered in the treatment of many patients with brain and head and neck tumors. Although there are many reports concerning the tolerance of the CNS, few have examined individual substructures of the brain and fewer still have had detailed dose information. This study has both. A three dimensional planning system was used to develop the combined proton beam/photon beam treatments for 27 patients with skull-base tumors. The cranial nerves and their related nuclei were delineated on the planning CT scans and the radiation dose to each was determined from three dimensional dose distributions. In the 594 CNS structures (22 structures/patient in 27 patients), there have been 17 structures (in 5 patients) with clinically manifest radiation injury, after a mean follow-up time of 74 months (range 40-110 months). From statistical analyses, dose is found to be a significant predictor of injury. Using logistic regression analysis, we find that, for each cranial nerve, at 60 Cobalt Gray Equivalent (CGE) the complication rate is 1% (0.5-3% with 95% confidence) and that the 5% complication rate occurs at 70 CGE (64-81 CGE with 95% confidence). The slope of the dose response curve (at 50%) is 3.2 (2.2-5.4 with 95% confidence). No significant relationship between dose and latency period for nerve injury was found.

Adolescent

Optimization of 3D radiation therapy with both physical and biological end points and constraints.

A new optimization model is described and its clinical usefulness is demonstrated. The optimization technique was developed to allow computer optimization of 3-dimensional radiation therapy plans with biological models of tumor and normal tissue response to radiation as well as with scores based on physical dose. The emphasis was placed on the optimization model, which should describe, as closely as possible, the goal of the radiation treatment, which is eradication of the tumor while sparing normal tissues. Since the statement of the goals may vary from case to case, a technique that allows a variety of objective functions and types of constraints was developed. The optimization algorithm is capable of handling nonlinear and even discrete score (objective) functions and constraints and effectively explores the vast space of feasible solutions in a relatively short time (minutes of MicroVax 3200 CPU time). An example of computer optimization of radiation therapy of a chordoma of the sphenoid bone using x-ray and proton beams is shown and compared with the best plans achieved by an experienced planner. Directions for future development of the algorithm, allowing optimization of beam orientation, are presented.

Chordoma

Dose-volume histograms.

A plot of a cumulative dose-volume frequency distribution, commonly known as a dose-volume histogram (DVH), graphically summarizes the simulated radiation distribution within a volume of interest of a patient which would result from a proposed radiation treatment plan. DVHs show promise as tools for comparing rival treatment plans for a specific patient by clearly presenting the uniformity of dose in the target volume and any hot spots in adjacent normal organs or tissues. However, because of the loss of positional information in the volume(s) under consideration, it should not be the sole criterion for plan evaluation. DVHs can also be used as input data to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). The sensitivity of TCP and NTCP calculations to small changes in the DVH shape points to the need for an accurate method for computing DVHs. We present a discussion of the methodology for generating and plotting the DVHs, some caveats, limitations on their use and the general experience of four hospitals using DVHs.

Humans

The role of uncertainty analysis in treatment planning.

The role of uncertainty analysis in 3-D treatment planning systems was addressed by four institutions which contracted with NCI to evaluate high energy photon external beam treatment planning. Treatment plans were developed at eight disease sites and the effects of uncertainties assessed in a number of experiments. Uncertainties which are patient-site specific included variations in the delineation of target volumes and normal tissues and the effects of positional uncertainties due to physiological motion and setup nonreproducibility. These were found to have a potentially major impact on the doses to the target volumes and to critical normal tissues which could result in significantly altered probabilities of tumor control and normal tissue complications. Other uncertainties, such as the conversion of CT data to electron densities, heterogeneities and dose calculation algorithms' weaknesses, are related to physical processes. The latter was noted to have the greatest potential contribution to uncertainty in some sites. A third category of uncertainty related to the treatment machine, the consequences of compensator misregistration, are exclusive to the site and the treatment portal. Because conventional treatment planning systems have not incorporated uncertainty analysis, tools and techniques had to be devised for this work; further development in this area is needed. Many of the analyses could not have been done without full 3-D capabilities of the planning systems, and it can be anticipated that the availability of uncertainty analysis in these systems which allow nontraditional beam arrangements will be of great value.

Humans

Tolerance of normal tissue to therapeutic irradiation.

The importance of knowledge on tolerance of normal tissue organs to irradiation by radiation oncologists cannot be overemphasized. Unfortunately, current knowledge is less than adequate. With the increasing use of 3-D treatment planning and dose delivery, this issue, particularly volumetric information, will become even more critical. As a part of the NCI contract N01 CM-47316, a task force, chaired by the primary author, was formed and an extensive literature search was carried out to address this issue. In this issue. In this manuscript we present the updated information on tolerance of normal tissues of concern in the protocols of this contract, based on available data, with a special emphasis on partial volume effects. Due to a lack of precise and comprehensive data base, opinions and experience of the clinicians from four universities involved in the contract have also been contributory. Obviously, this is not and cannot be a comprehensive work, which is beyond the scope of this contract.

Bone and Bones

Fitting of normal tissue tolerance data to an analytic function.

During external beam radiotherapy, normal tissues are irradiated along with the tumor. Radiation therapists try to minimize the dose of normal tissues while delivering a high dose to the target volume. Often this is difficult and complications arise due to irradiation of normal tissues. These complications depend not only on the dose but also on volume of the organ irradiated. Lyman has suggested a four-parameter empirical model which can be used to represent normal tissue response under conditions of uniform irradiation to whole and partial volumes as a function of the dose and volume irradiated. In this paper, Lyman's model has been applied to a compilation of clinical tolerance data developed by Emami et al. The four parameters to characterize the tissue response have been determined and graphical representations of the derived probability distributions are presented. The model may, therefore, be used to interpolate clinical data to provide estimated normal tissue complication probabilities for any combination of dose and irradiated volume for the normal tissues and end points considered.

Humans

Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations.

New tools are needed to help in evaluating 3-D treatment plans because of the large volume of data. One technique which may prove useful is the application of complication probability calculations. A method of calculating complication probabilities for inhomogeneously irradiated normal tissues is presented in this paper. The method uses clinical estimates of tolerance doses for a few discreet conditions of uniform partial organ irradiation, an empirical fit of a continuous function to these data, and a technique (the effective volume method) for transforming nonuniform dose-volume histograms into equivalent uniform histograms. The behavior of the effective volume histogram reduction method for various boundary conditions is reviewed. The use of complication probabilities in evaluating treatment plans is presented, using examples from an NCI 3-D treatment planning contract.

Humans

Three-dimensional treatment planning for para-aortic node irradiation in patients with cervical cancer.

Three-dimensional treatment planning has been used by four cooperating centers to prepare and analyze multiple treatment plans on two cervix cancer patients. One patient had biopsy-proven and CT-demonstrable metastasis to the para-aortic nodes, while the other was at high risk for metastatic involvement of para-aortic nodes. Volume dose distributions were analyzed, and an attempt was made to define the role of 3-D treatment planning to the para-aortic region, where moderate to high doses (50-66 Gy) are required to sterilize microscopic and gross metastasis. Plans were prepared using the 3-D capabilities for tailoring fields to the target volumes, but using standard field arrangements (3-D standard), and with full utilization of the 3-D capabilities (3-D unconstrained). In some but not all 3-D unconstrained plans, higher doses were delivered to the large nodal volume and to the volume containing gross nodal disease than in plans analyzed but not prepared with full 3-D capability (3-D standard). The small bowel was the major dose limiting organ. Its tolerance would have been exceeded in all plans which prescribed 66 Gy to the gross nodal mass, although some reduction in small bowel near-maximum dose was achieved in the 3-D unconstrained plans. All plans were able to limit doses to other normal organs to tolerance levels or less, with significant reductions seen in doses to spinal cord, kidneys, and large bowel in the 3-D unconstrained plans, as compared to the 3-D standard plans. A high probability of small bowel injury was detected in one of four 3-D standard plans prescribed to receive 50 Gy to the large para-aortic nodal volume; the small bowel dose was reduced to an acceptable level in the corresponding 3-D unconstrained plan. An optimum beam energy for treating this site was not identified, with plans using 4, 6, 10, 15, 18, and 25 MV photons all being equally acceptable. Attempts to deliver moderate or high doses (50-66 Gy) to this region should be made only after careful analysis of the plan with techniques similar to those employed in this study.

Aged

Calculation of normal tissue complication probability and dose-volume histogram reduction schemes for tissues with a critical element architecture.

We investigate a model of normal tissue complication probability for tissues that may be represented by a critical element architecture. We derive formulas for complication probability that apply to both a partial volume irradiation and to an arbitrary inhomogeneous dose distribution. The dose-volume isoeffect relationship which is a consequence of a critical element architecture is discussed and compared to the empirical power law relationship. A dose-volume histogram reduction scheme for a "pure" critical element model is derived. In addition, a point-based algorithm which does not require precomputation of a dose-volume histogram is derived. The existing published dose-volume histogram reduction algorithms are analyzed. We show that the existing algorithms, developed empirically without an explicit biophysical model, have a close relationship to the critical element model at low levels of complication probability. However, we also show that they have aspects which are not compatible with a critical element model and we propose a modification to one of them to circumvent its restriction to low complication probabilities.

Algorithms

Waiting patiently.

Explore the source record for details and available documents.

Appointments and Schedules

Considerations in fractionated proton radiation therapy: clinical potential and results.

Protons have a finite range in tissue and can provide a better concentration of radiation dose in the tumor than conventional X-rays in certain situations. The development of optimized treatment plans for X-rays and protons followed by a comparative evaluation is one method of selecting tumor sites best suited for proton treatment. The preliminary results of comparative treatment planning for base of skull tumors and carcinoma of the prostate are discussed. These comparisons suggest a clinical gain for proton treatment of tumors in these locations. The clinical experience with fractionated proton treatment of several tumor sites is also discussed. The results of high dose proton treatment of chordomas and low grade chondrosarcomas of the base of skull is particularly promising: an actuarial 5-year local control of 78% has been obtained in 50 patients followed for a minimum of 22 months.

Carcinoma

Fractionated proton radiation therapy of cranial and intracranial tumors.

Since 1973 fractionated proton radiation therapy has been used in the treatment of malignant disease. Protons have favorable physical characteristics that yield dose distributions superior to those of photons in certain clinical situations. As of December 31, 1987, 1,678 patients had been treated. Of these, 110 had chordomas or low-grade chondrosarcomas of the base of skull. The first 68 patients have a minimum follow-up of 17 months. The median dose was 69 Cobalt Gray Equivalent (CGE). (CGE is the dose in proton Gray multiplied by 1.1, which is the relative biological effectiveness for protons relative to 60Cobalt.) The actuarial 5-year local control rate is 82%, and the disease-free survival rate is 76%. Thirteen patients with meningiomas have been treated, following subtotal resection. The median dose was 59.4 CGE. With a median follow-up of 26 months, no patient has had tumor progression. In addition, nine patients with gliomas and 12 with craniopharyngiomas have been treated.

Adolescent

Increased efficacy of radiation therapy by use of proton beam.

Proton beam treatment techniques provide a powerful approach to improving dose distribution (decrease treatment volume towards target volume) and hence increasing dose to target with resultant higher tumor control rates and lesser morbity. To achieve these dose distributions in patients requires use of modern imaging techniques, rigid immobilization systems, confirmation of target position vis a vis the proton beam at each treatment session, treatment planning which feature beam's eye view, displays of uncertainty, dose at each anatomic point, boli based on accurate assessment of density along each pixel, etc. Experience at MGH/MEEI/HCL has yielded a disease-free survival of 78% for patients with chordoma/chondrosarcoma of base of skull. Local control is achieved by 98% of patients treated for choroidal melanoma.

Chondrosarcoma

Neurovisual outcome following proton radiation therapy.

From February 1981 to January 1984, 20 patients with a tumor of the upper clivus received proton irradiation at the Harvard Cyclotron Laboratory. For 15 patients with known neurovisual status (including visual acuity, color vision, visual field, and fundus examinations) we obtained a cumulative dose-volume histogram (DVH) of the optic nerves (ON) and the optic chiasm. The prescribed tumor doses ranged from 66.6 to 74.4 Cobalt Gray Equivalent (CGE) with a daily fraction size of 1.8 to 2.1 CGE. CGE is used because modulated protons have an RBE of 1.1 compared to 60Co. The follow-up ranged from 30 to 68 months (median 52). Two patients developed, 10 and 36 months post irradiation, a progressive visual deterioration affecting both eyes. This was attributed to an ON and a chiasm injury in one patient and to bilateral ON injury in the other patient. In the first patient, the dose-volume analysis indicated that approximately half of the ON and of the chiasm had received 65 CGE and 55 CGE, respectively. In the second patient, it indicated that a quarter of the left ON (LON) had received 55 CGE whereas the dose to the right ON (RON) was significantly less. This patient had diabetes mellitus which may be a predisposing factor. From this study, a complication rate of 20% (1/5) is observed when a substantial portion of the ON is taken to 65 CGE, while it doesn't exceed 12.5% (2/16) and 7.5% (1/13) at 55 CGE for the ON and for the chiasm, respectively. This suggests a tolerance dose implying a 10% rate of major complications close to 55 CGE. When a tumor requires a high radiation-dose, the exclusion of these structures at 55 to 60 Gy is recommended.

Adult

The risk of enucleation after proton beam irradiation of uveal melanoma.

Enucleation after proton beam irradiation of uveal melanomas occurred in 64 (6.4%) of 994 eyes with a median follow-up time of 2.7 years. The median time between irradiation and enucleation in the 64 enucleated eyes was 13 months. The probability of retaining the eye was 95 and 90%, 2 and 5 years postirradiation, respectively. Three percent of eyes were enucleated during posttreatment year 1, and the yearly rate was 1% by the fourth year. No patient had enucleation later than 5 1/2 years posttreatment. The complication most likely to result in enucleation was neovascular glaucoma although this was frequently managed without enucleation. Other common reasons for enucleation were documented or suspected tumor growth and complete retinal detachment with associated loss of vision. The leading risk factors for enucleation were anterior tumor margin involving the ciliary body, tumor height greater than 8 mm, and proximity of the tumor to the fovea. Based on the presence or absence of these factors, 5-year eye retention rates were 99, 92, and 76% for low-, moderate-, and high-risk groups, respectively. Thus, the probability of eye retention after proton beam irradiation is high even among those at greatest risk of enucleation.

Eye Enucleation