Aperture weighted cardiac reconstruction for cone-beam CT.

Multi-row detectors together with fast rotating gantries made cardiac imaging possible for CT. Due to the cardiac motion, ECG gating has to be integrated into the reconstruction of the data measured on a low pitch helical trajectory. Since the first multi-row scanners were introduced, it has been shown that approximative true cone-beam reconstruction methods are most suitable for the task of retrospectively gated cardiac volume CT. In this paper, we present the aperture weighted cardiac reconstruction (AWCR), which is a three-dimensional reconstruction algorithm of the filtered back-projection type. It is capable of handling all illumination intervals of an object point, which occur as a consequence of a low pitch helical cone-beam acquisition. Therefore, this method is able to use as much redundant data as possible, resulting in an improvement of the image homogeneity, the signal to noise ratio and the temporal resolution. Different optimization techniques like the heart rate adaptive cardiac weighting or the automatic phase determination can be adopted to AWCR. The excellent image quality achieved by AWCR is presented for medical datasets acquired with both a 40-slice and a 64-slice cone-beam CT scanner.

Algorithms↗

Experimental 16-row CT evaluation of in-stent restenosis using new stationary and moving cardiac stent phantoms: experimental examination.

PURPOSE: The aim of this study was to evaluate in-stent restenosiss using a newly developed stationary and moving cardiac stent phantom with three built-in artificial stenoses and a 16-row MDCT. MATERIALS AND METHODS: A newly developed coronary stent phantom with three artificial stenoses--low (approx. 30 %), medium (approx. 50 %) and high (approx. 70 %)--was attached to a moving heart phantom and used to evaluate the ability of 16-row MDCT to visualize in-stent restenosis. High resolution scans (16 x 0.75 mm, 250 mm FOV) were made to identify the baseline for image quality. The non-moving phantom was scanned (16 x 0.75 mm, routine cardiac scan protocol) first without and then with implementation of an ECG signal at various simulated heart rates (HR 40 to 120 bpm) and pitches (0.15 to 0.3). The moving cardiac phantom was scanned at the same simulated heart rates but at a pitch of 0.15. Images were reconstructed at every 10 % of the RR interval using a multi-cycle real cone-beam reconstruction algorithm. Multi-planar reformations (MPR) were made for the image evaluation. The image quality was assessed using a three-point scale, and stent patency and stenoses detection were evaluated using a four-point scale. To evaluate the image quality and to grade the stent stenoses, the median values were calculated while considering the reconstruction interval. RESULTS: The image quality for the static phantom was adequate in 97 % of the measurements. In this phantom, every stenosis was detected independent of the pitch and heart rate used. The dynamic stent phantom yielded the best results at 0 %, 40 %, and 50 % of the RR interval at a pitch of 0.15. The low stenosis was visible at a simulated heart rate of up to 80 bpm. Patency can be detected at heart rates greater than 80 bpm. CONCLUSION: The newly developed moving stent phantom allowed a nearly in-vivo condition for detecting re-stenoses within a stent. In this phantom study the use of a 16-row MDCT allowed the detection of re-stenosis within a coronary stent at a heart rate of up to 80 bpm. This phantom can then be used for future studies, e. g. with a 64-row MDCT.

Artifacts↗

Helical cardiac cone beam CT reconstruction with large area detectors: a simulation study.

Retrospectively gated cardiac volume CT imaging has become feasible with the introduction of heart rate adaptive cardiac CT reconstruction algorithms. The development in detector technology and the rapid introduction of multi-row detectors has demanded reconstruction schemes which account for the cone geometry. With the extended cardiac reconstruction (ECR) framework, the idea of approximate helical cone beam CT has been extended to be used with retrospective gating, enabling heart rate adaptive cardiac cone beam reconstruction. In this contribution, the ECR technique is evaluated for systems with an increased number of detector rows, which leads to larger cone angles. A simulation study has been carried out based on a 4D cardiac phantom consisting of a thorax model and a dynamic heart insert. Images have been reconstructed for different detector set-ups. Reconstruction assessment functions have been calculated for the detector set-ups employing different rotation times, relative pitches and heart rates. With the increased volume coverage of large area detector systems, low-pitch scans become feasible without resulting in extensive scan times, inhibiting single breath hold acquisitions. ECR delivers promising image results when being applied to systems with larger cone angles.

Algorithms↗

Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom.

Measurements of spatial and temporal resolution for ECG-gated scanning of a stationary and moving heart phantom with a 16-row MDCT were performed. A resolution phantom with cylindrical holes from 0.4 to 3.0 mm diameter was mounted to a cardiac phantom, which simulates the motion of a beating heart. Data acquisition was performed with 16x0.75 mm at various heart rates (HR, 60-120 bpm), pitches (0.15-0.30) and scanner rotation times (RT, 0.42 and 0.50 s). Raw data were reconstructed using a multi-cycle real cone-beam reconstruction algorithm at multiple phases of the RR interval. Multi-planar reformations (MPR) were generated and analyzed. Temporal resolution and cardiac cycles used for image reconstruction were calculated. In 97.2% (243/250) of data obtained with the stationary phantom, the complete row of holes with 0.6 mm was visible. These results were independent of heart rate, pitch, scanner rotation time and phase point of reconstruction. For the dynamic phantom, spatial resolution was determined during phases of minimal motion (116/250). In 40.5% (47/116), the resolution was 0.6 mm and in 37.1% (43/116) 0.7 mm. Temporal resolution varied between 63 and 205 ms, using 1.5-4.37 cardiac cycles for image reconstruction.

Electrocardiography↗

Cardiac cone-beam CT volume reconstruction using ART.

Modern computed tomography systems allow volume imaging of the heart. Up to now, approximately two-dimensional (2D) and 3D algorithms based on filtered backprojection are used for the reconstruction. These algorithms become more sensitive to artifacts when the cone angle of the x-ray beam increases as it is the current trend of computed tomography (CT) technology. In this paper, we investigate the potential of iterative reconstruction based on the algebraic reconstruction technique (ART) for helical cardiac cone-beam CT. Iterative reconstruction has the advantages that it takes the cone angle into account exactly and that it can be combined with retrospective cardiac gating fairly easily. We introduce a modified ART algorithm for cardiac CT reconstruction. We apply it to clinical cardiac data from a 16-slice CT scanner and compare the images to those obtained with a current analytical reconstruction method. In a second part, we investigate the potential of iterative reconstruction for a large area detector with 256 slices. For the clinical cases, iterative reconstruction produces excellent images of diagnostic quality. For the large area detector, iterative reconstruction produces images superior to analytical reconstruction in terms of cone-beam artifacts.

Algorithms↗

A quantitative analysis of 3-D coronary modeling from two or more projection images.

A method is introduced to examine the geometrical accuracy of the three-dimensional (3-D) representation of coronary arteries from multiple (two and more) calibrated two-dimensional (2-D) angiographic projections. When involving more then two projections, (multiprojection modeling) a novel procedure is presented that consists of fully automated centerline and width determination in all available projections based on the information provided by the semi-automated centerline detection in two initial calibrated projections. The accuracy of the 3-D coronary modeling approach is determined by a quantitative examination of the 3-D centerline point position and the 3-D cross sectional area of the reconstructed objects. The measurements are based on the analysis of calibrated phantom and calibrated coronary 2-D projection data. From this analysis a confidence region (alpha degrees approximately equal to [35 degrees - 145 degrees]) for the angular distance of two initial projection images is determined for which the modeling procedure is sufficiently accurate for the applied system. Within this angular border range the centerline position error is less then 0.8 mm, in terms of the Euclidean distance to a predefined ground truth. When involving more projections using our new procedure, experiments show that when the initial pair of projection images has an angular distance in the range alpha degrees approximately equal to [35 degrees - 145 degrees], the centerlines in all other projections (gamma = 0 degrees - 180 degrees) were indicated very precisely without any additional centering procedure. When involving additional projection images in the modeling procedure a more realistic shape of the structure can be provided. In case of the concave segment, however, the involvement of multiple projections does not necessarily provide a more realistic shape of the reconstructed structure.

Algorithms↗

Automatic phase determination for retrospectively gated cardiac CT.

The recent improvements in CT detector and gantry technology in combination with new heart rate adaptive cone beam reconstruction algorithms enable the visualization of the heart in three dimensions at high spatial resolution. However, the finite temporal resolution still impedes the artifact-free reconstruction of the heart at any arbitrary phase of the cardiac cycle. Cardiac phases must be found during which the heart is quasistationary to obtain outmost image quality. It is challenging to find these phases due to intercycle and patient-to-patient variability. Electrocardiogram (ECG) information does not always represent the heart motion with an adequate accuracy. In this publication, a simple and efficient image-based technique is introduced which is able to deliver stable cardiac phases in an automatic and patient-specific way. From low-resolution four-dimensional data sets, the most stable phases are derived by calculating the object similarity between subsequent phases in the cardiac cycle. Patient-specific information about the object motion can be determined and resolved spatially. This information is used to perform optimized high-resolution reconstructions at phases of little motion. Results based on a simulation study and three real patient data sets are presented. The projection data were generated using a 16-slice cone beam CT system in low-pitch helical mode with parallel ECG recording.

Algorithms↗

Helical cardiac cone beam reconstruction using retrospective ECG gating.

In modern computer tomography (CT) systems, the fast rotating gantry and the increased detector width enable 3D imaging of the heart. Cardiac volume CT has a high potential for non-invasive coronary angiography with high spatial resolution and short scan time. Due to the increased detector width, true cone beam reconstruction methods are needed instead of adapted 2D reconstruction schemes. In this paper, the extended cardiac reconstruction method is introduced. It integrates the idea of retrospectively gated cardiac reconstruction for helical data acquisition into a cone beam reconstruction framework. It leads to an efficient and flexible algorithmic scheme for the reconstruction of single- and multi-phase cardiac volume datasets. The method automatically adapts the number of cardiac cycles used for the reconstruction. The cone beam geometry is fully taken into account during the reconstruction process. Within this paper, results are presented on patient datasets which have been acquired using a 16-slice cone beam CT system.

Algorithms↗

A reconstruction algorithm for coherent scatter computed tomography based on filtered back-projection.

Coherent scatter computed tomography (CSCT) is a reconstructive x-ray imaging technique that yields the spatially resolved coherent-scatter form factor of the investigated object. Reconstruction from coherently scattered x-rays is commonly done using algebraic reconstruction techniques (ART). In this paper, we propose an alternative approach based on filtered back-projection. For the first time, a three-dimensional (3D) filtered back-projection technique using curved 3D back-projection lines is applied to two-dimensional coherent scatter projection data. The proposed algorithm is tested with simulated projection data as well as with projection data acquired with a demonstrator setup similar to a multi-line CT scanner geometry. While yielding comparable image quality as ART reconstruction, the modified 3D filtered back-projection algorithm is about two orders of magnitude faster. In contrast to iterative reconstruction schemes, it has the advantage that subfield-of-view reconstruction becomes feasible. This allows a selective reconstruction of the coherent-scatter form factor for a region of interest. The proposed modified 3D filtered back-projection algorithm is a powerful reconstruction technique to be implemented in a CSCT scanning system. This method gives coherent scatter CT the potential of becoming a competitive modality for medical imaging or nondestructive testing.

Algorithms↗

Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction.

Cone beam computed tomography scanners in combination with heart rate adaptive reconstruction schemes have the potential to enable cardiac volumetric computed tomography (CT) imaging for a larger number of patients and applications. In this publication, an adaptive scheme for the automatic and patient-specific reconstruction optimization is introduced to improve the temporal resolution and image quality. The optimization method permits the automatic determination of the required amount of gated helical cone beam projection data for the reconstruction volume. It furthermore allows one to optimize subvolume reconstruction yielding an increased temporal resolution. In addition, methods for the assessment of the temporal resolution are given which enable a quantitative documentation of the reconstruction improvements. Results are presented for patient data sets acquired in low pitch helical mode using a 16-slice cone beam CT system with parallel ECG recording.

Algorithms↗

Technology failure analysis: understanding why a diabetes management tool developed for a Personal Digital Assistant (PDA) didn't work in a randomized controlled trial.

Managing Type 1 Diabetes Mellitus is a challenging feat especially for young patients. It is a tedious and demanding disease which requires painful self-monitoring and injections multiple times per day. Many patients are unable to achieve good blood sugar control, in spite of strong evidence that good control leads to better outcomes. Many caregivers believe that more communication between caregivers and patients could lead to better control. This paper describes a tool that was developed to improve communication between caregivers and patients, its testing, how it failed to achieve its outcomes and recommendations for improvement.

Blood Glucose Self-Monitoring↗

An X-ray-based method for the determination of the contrast agent propagation in 3-D vessel structures.

A method for the determination of the contrast-agent propagation in vessel trees is presented. A standard three-dimensional (3-D) rotational angiography procedure is performed to reconstruct the morphology of the contrast-filled vessel tree in a 3-D volume. An additional fluoroscopy projection series acquired with a fixed projection angle delivers the temporal information of the bolus propagating. The mapping of the propagation information from the two-dimensional projections to the 3-D image data set is the topic of this paper. A symbolic tree structure is built up that represents the vessel tree including bifurcations. Neighborhood relations between vessel pieces are given in three dimensions. This facilitates filtering procedures and plausibility controls of the resulting time dependent 3-D data set. The presented method proved to be accurate with phantom data and gives novel insight in the feeding structure of arterio-venous malformations and aneurysms.

Algorithms↗

Artifact analysis of approximate helical cone-beam CT reconstruction algorithms.

In this paper, four approximate cone-beam CT reconstruction algorithms are compared: Advanced single slice rebinning (ASSR) as a representative of algorithms employing a two dimensional approximation, PI, PI-SLANT, and 3-PI which all use a proper three dimensional back-projection. A detailed analysis of the image artifacts produced by these techniques shows that aliasing in the z-direction is the predominant source of artifacts for a 16-row scanner with 1.25 mm nominal slice thickness. For a detector with isotropic resolution of 0.5 mm, we found that ASSR and PI produce different kinds of artifacts which are almost at the same level, while PI-SLANT produces none of these artifacts. It is shown that the use of redundant data in the 3-PI method suppresses aliasing artifacts efficiently for both scanners.

Algorithms↗

Angular weighted hybrid cone-beam CT reconstruction for circular trajectories.

Hybrid reconstruction techniques have been introduced for the volume reconstruction of axially truncated cone-beam computed tomography projection data acquired along a circular source-detector trajectory. The introduction of weighted half-scan techniques into this framework is described in this paper. Due to the cone-beam geometry it is not possible to perform the weighting on the projections as is typically done in conventional single-line computed tomography. Hence, in this paper we present an efficient way to incorporate angular weighting functions, depending on the object point position, into the framework of hybrid cone-beam reconstruction. Four different angular weighting functions are introduced and discussed with respect to their cone-beam artefact behaviour and their influence on the signal-to-noise ratio. As a result, the most effective angular weighting function for hybrid circular cone-beam reconstruction is determined by means of a simulation study based on mathematical phantoms and clinical data sets. This distance-weighted angular weighting scheme yields the best results in terms of high image quality, low computational complexity and signal-to-noise variations in the reconstruction volume.

Computer Simulation↗

A fast and efficient method for sequential cone-beam tomography.

Sequential cone-beam tomography is a method that uses data of two or more parallel circular trajectories of a cone-beam scanner to reconstruct the object function. We propose a condition for the data acquisition that ensures that all object points between two successive circles are irradiated over an angular span of the x-ray source position of exactly 360 degrees in total as seen along the rotation axis. A fast and efficient approximative reconstruction method for the proposed acquisition is presented which uses data from exactly 360 degrees for every object point. It is based on the Tent-FDK method which was recently developed for single circular cone-beam CT. The measurement geometry does not provide sufficient data for exact reconstruction but it is shown that the proposed reconstruction method provides satisfying image quality for small cone angles.

Algorithms↗

3D cone-beam CT reconstruction for circular trajectories.

3D reconstruction from 2D projections obtained along a single circular source trajectory is most commonly done using an algorithm due to Feldkamp, Davis and Kress. In this paper we propose an alternative approach based on a cone-beam to parallel-beam rebinning step, a corresponding rebinning step into a rectangular virtual detector plane and a filtered backprojection. This approach yields an improved image quality reflected by a decreased low-intensity drop which is well known for 3D reconstruction from projection data obtained along circular trajectories. At the same time the computational complexity is lower than in Feldkamp's original approach. Based on this idea, a hybrid 3D cone-beam reconstruction method is formulated that enlarges the reconstruction volume in its dimension along the rotation axis of the cone-beam CT system. This enlargement is achieved by applying different reconstruction conditions for each voxel. An optimal ratio between the reconstructible and irradiated volume of the scanned object is achieved.

Algorithms↗

The n-PI-method for helical cone-beam CT.

A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes are compatible with exact reconstruction methods, and the adaptation of exact reconstruction algorithms to the new acquisition geometry is described. At the same time, the so-called PI-sufficiency condition is fulfilled. Moreover, a good fit to the acquisition requirements of the various medical applications of cone-beam CT is achieved. In contrast to other helical cone-beam acquisition and reconstruction methods, the n-PI-method introduced in this publication allows for variable pitches of the acquisition helix. This additional feature will introduce a higher flexibility into the acquisition protocols of future medical cone-beam scanners. An approximative n-PI-filtered backprojection (n-PI-FBP) reconstruction method is presented and verified. It yields convincing image quality.

Image Processing, Computer-Assisted↗

[Angiosarcoma of the right atrium: local control via low radiation doses and razoxane. A case report].

BACKGROUND: Angiosarcomas of the heart are rare neoplasms bearing an unfavorable prognosis. In recent series, the median survival is about 5 months. The response to radiation therapy is uncertain. CASE REPORT: A 65-year-old copper smith with an angiosarcoma of the right atrium and metastases of the liver received a partial resection of the primary tumor in January 1992. This was followed by a polychemotherapy including ifosfamide, epirubicin and dacarbacin (DTIC). In April 1992, after 5 cycles of this treatment a large regrowth of the primary and multiple pulmonary metastases were observed. After a 4-day pretreatment with the radiosensitizer razoxane, the large tumor of the right heart was irradiated with 25 MV photons of a linear accelerator. Single doses of 200 cGy were given via parallel opposed fields. The total radiation dose at the tumor was 30 Gy. Concomitantly, razoxane was given at a dose of 125 mg twice daily during the radiation days until the end of the radiotherapy. The treatment was well tolerated and the patient went into a subtotal remission. Chest X-rays from September 1992 revealed a progression of the metastases in the lung and the liver, the recurrent tumor of the right atrium remained in a subtotal remission. The patient was retreated with ifosfamide, epirubicin and DTIC. No substantial remission of the metastases occurred and the patient died at the end of January 1993. At autopsy, the recurrent primary and the lung metastases within the region of the former radiation field remained locally controlled. CONCLUSION: Reviewing the literature and considering this case, irradiation seems to be a valid treatment option for the local control of cardiac angiosarcomas. The combination of radiotherapy with razoxane eventually allows a considerable reduction of the radiation dose.

Aged↗