Determination of the minimum number of marginal gap measurements required for practical in-vitro testing.

STATEMENT OF PROBLEM: Gap measurements along margins are frequently used to assess the quality of single crowns. However, the number of gap measurements required for clinically relevant results in laboratory studies is not known. PURPOSE: This study estimated the minimum number of gap measurements on margins of single crowns to produce relevant results for gap analysis. METHODS AND MATERIAL: Ten all-ceramic crowns were fabricated on a master steel die. Gaps along crown margins were investigated in a scanning electron microscope on the master steel die without cementation and on replica dies after conventional cementation. Measurements were made in 100 microm steps according to 3 gap definitions. The initial number of measurements per crown (n = 230) was reduced to smaller subsets using both systematic and random approaches to determine the impact on the quality of results. RESULTS: On the data of gap definition 1, reduction from 230 to about 50 measurements caused less than +/-5 microm variability for arithmetic means. Analysis of standard errors showed slowly increasing values smaller than 3 microm, both indicating no relevant impact on the quality of results. Smaller data sizes yielded accelerated increase of standard errors and divergent variabilities of mean. The minimum of 50 measurements did not depend on gap definition or on cementation condition. CONCLUSION: Fifty measurements are required for clinically relevant information about gap size regardless of whether the measurement sites are selected in a systematic or random manner, which is far more than what current in vitro studies use.

Aluminum Oxide↗

[Using individually designed ceramic implants for secondary reconstruction of the bony orbit].

The use of autogenous transplants and the application of intraoperatively customised alloplastic materials show, in cases of secondary orbital reconstruction, a higher postoperative morbidity caused by additional approaches to the transplant donor site. On the other hand, thorough surgical exploration and fitting of the transplants or alloplastic materials greatly prolongs operating times. For these reason we designed ceramic implants (Bioverit) on the basis of stereolithography models and prefabricated them using a commercially available dental copy milling unit (Celay). In five cases up until now seven customised implants have been inserted for reconstruction of the lamina papyracea, zygomatic complex and infraorbital floor and rim. Encouraged by the good postoperative aesthetic and functional results, with significantly reduced operating times and morbidity in all cases, we will continue to take this technique into account for reconstruction after complex orbital fractures.

Adult↗

Orbital reconstruction with individually copy-milled ceramic implants.

Diagnostic advances such as computed tomography and new surgical techniques have dramatically improved both the functional and aesthetic outcome of orbital reconstructions. Taking a further approach, we designed ceramic implants (Bioverit) on the basis of stereolithographic models. After copy milling a resin template with a commercially available dental unit (Celay), the prefabricated implants were inserted for reconstruction of the lamina papyracea (n = 1), zygomatic complex (n = 2), infraorbital floor (n = 5), and rim (n = 3). Intraoperatively, only slight modifications of the implants had to be performed. The results were encouraging, as all cases showed a good aesthetic and functional postoperative outcome. Preoperative evaluation of the osseous defect and prefabrication of the required implant reduced operating time and patient morbidity significantly.

Adult↗

Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro.

The aim of this study was to evaluate the marginal fit of copy-milled Celay In-Ceram crowns after different fabrication steps and to compare light-microscopic with scanning-electron-microscopic data. A master steel die of an upper middle incisor with a shoulder preparation and a rounded inner line angle was used. Impressions were taken to produce 10 working stone dies. One crown per working die was manufactured. The evaluation of the external marginal gap was performed on the master steel die by using a light microscope and a computerized video image analysis system after copy milling (A), glass infiltration (B), and veneering (C). Approximately 3900 readings were taken. In a final series the veneered crowns were measured by using a scanning electron microscope (Cs), yielding approximately 1000 readings. The results obtained were: A mean, 25.1 microm; s.d., 5.1 microm; range, 2.5-76.8 microm: B mean, 20.6 microm; s.d., 2.3 microm; range, 2.5-76.1 microm: C mean, 18.3 microm; s.d., 4.1 microm; range, 2.5-87.2 microm: Cs mean, 23.0 microm; s.d., 7.6 microm; range, 0.0-94.5 microm. The results were statistically evaluated using the t-test. The differences found between the series did not show practical relevance. Therefore, it is concluded that the manufacturing steps after copy milling have no obvious influence on the external marginal gap width. Scanning electron microscopic data seem to confirm the light-microscopic results. Hence, we expect that the Celay In-Ceram method yields a clinically acceptable marginal fit.

Aluminum Oxide↗

Copy-milled all-ceramic Celay-InCeram crowns for modified CeraOne abutments: a technical report.

With single-tooth implant restorations, a divergence between implant and crown axes, a lack of interocclusal space, and supracrestal implant placement may result in fabrication problems for the prosthetic crown. It was found that the CeraOne abutment can be modified in three ways: (1) height reduction is possible; (2) a 15-degree taper can be applied; and (3) the cervical shoulder can be reduced in height with a chamfer remaining. For these modified abutments, the Celay-InCeram system was used to create individual, all-ceramic crowns for these modified abutments with improved esthetics.

Aluminum Oxide↗

The influence of different cementation modes on the fracture resistance of feldspathic ceramic crowns.

One hundred twenty pressed feldspathic ceramic crowns were luted to 20 steel dies using six different cementation modes. Fracture resistance was tested under an angle of 45 degrees and was determined as the maximal fracture load. Crowns were tested with luting agent only (groups A and C) and after etching with hydrofluoric acid, silanating, and the application of a bonding agent (groups B, D, E, and F). The resulting means were: phosphate cement 294.3 (A) and 282.2 (B); glass-ionomer cement 217.2 (C) and 255.4 (D); resin composite 382.2 (E) and 687.6 (F). Statistical analysis revealed significantly greater fracture resistance (P < .01) of resin luted crowns. Bonding to the die almost doubled the fracture resistance. Conditioning of the inner surfaces of the crowns did not improve the fracture resistance of crowns luted using zinc phosphate or glass-ionomer cements.

Acrylates↗