The authors describe a study in which they placed 126 Class V composite resin restorations without mechanical retention, divided into three groups of 42, in 23 patients. They followed the performance of the restorations over a three-year period. For all three groups, restorations were placed using All-Bond 2 dental adhesive and Z100 composite resin; A.R.T. Bond and Brilliant Dentin composite; and Prisma Universal Bond 3 and Variglass VLC polyacid-modified composite resin. The authors evaluated retention as well as color stability, wear resistance, sensitivity, sulcular depth, loss of attachment, bleeding on probing and crevicular fluid flow. Based on their results, the authors propose that restoration of Class V lesions without using mechanical retention could be expected to succeed in seven of 10 restorations over a three-year period using these restorative systems.

Acrylic Resins

Performance of basic ventricular tachycardia detection algorithms in implantable cardioverter defibrillators: implications for device programming.

Around 20% of patients with third generation implantable cardioverter defibrillators receive inappropriate therapy, usually triggered by atrial fibrillation. This is because the criteria used for ventricular tachycardia detection by current implantable cardioverter defibrillators are based on the analysis of a sequence of RR intervals and may be inappropriately satisfied by supraventricular tachyarrhythmias. Algorithms for ventricular tachycardia detection were challenged against the full RR interval sequences from 482 spontaneous episodes of atrial fibrillation and 260 spontaneous episodes of ventricular tachycardia to determine their ability to discriminate between the arrhythmias. The sensitivities and specificities of the algorithms were calculated over a wide range of programmable parameters. For a given window length and detection interval, the most stringent algorithms, that required all beats to be classified as "fast", were more specific than those allowing a proportion of "normal" intervals, even after adjustment for differing sensitivity. These differences were less marked for faster tachycardias. Specificity increased with the detection window length to a limit of approximately 18 beats. We conclude that ventricular tachycardia is detected with the highest specificity if all beats in an analyzed sequence are required to be "fast," even after lengthening of the tachycardia detection interval to maintain sensitivity. Further improvement in algorithm performance may require the incorporation of criteria such as tachycardia onset and stability.

Algorithms

Catheter ablation for successful management of left posterior fascicular tachycardia: an approach guided by recording of fascicular potentials.

OBJECTIVE: To assess whether catheter ablation of fascicular tachycardia can be facilitated by the recording of sharp deflections arising from the mid-septum---inferior apical septum of the left ventricle. PATIENTS AND METHODS: Seven consecutive patients (mean age 29 (range 16-43) years) with ventricular tachycardia originating from the left posterior fascicle underwent electrophysiology study and detailed mapping of endocardial activation. Selection of ablation sites in the last five patients was based on the recording, during left posterior fascicular tachycardia and sinus rhythm, of a discrete potential preceding the earliest ventricular electrogram, which was thought to represent conduction through the posterior fascicle. RESULTS: Patients were treated with low energy direct current or radiofrequency current ablation. The median fluoroscopy and procedure times were 23 (range 6-42) min and 110 (range 50-176) min, respectively. In a follow up period of 4 to 16 months, six patients were asymptomatic and one had minor symptoms. No patient had any change in intraventricular conduction. Similar potentials were also recorded from the left posterobasal septum in three of eight patients who underwent catheter ablation of left free wall accessory pathways. CONCLUSION: Fascicular potentials can be reproducibly recorded in left posterior fascicular tachycardia and may serve as a reliable marker for successful ablation procedures. The relation of these potentials with the substrate of the tachycardia, however, remains obscure.

Adult

Effects of passive tilt and submaximal exercise on spectral heart rate variability in ventricular fibrillation patients without significant structural heart disease.

It has been shown that tilt and exercise elicit significant changes in autonomic activity in normal subjects and that submaximal exercise causes a greater reduction in heart rate variability (HRV) in animals susceptible to ventricular fibrillation (VF). Whether there is an abnormal HRV response to tilt and exercise in patients at risk of sudden cardiac death (SCD) remains unknown. Short-term HRV before and during passive tilt and exercise was studied in 12 survivors of out-of-hospital cardiac arrest with documented VF and compared with 12 age- and sex-matched normal controls. No patient had significant structural heart disease or left ventricular dysfunction. HRV was computed as total-frequency (TF, 0.01 to 1.00 Hz), low-frequency (LF, 0.04 to 0.15 Hz) and high-frequency (HF, 0.15 to 0.40 Hz) components. There was no significant difference between normal controls and SCD survivors in HRV before or during tilt or submaximal exercise testing. The HF component was significantly decreased during tilt compared with that in the supine position in both normal controls (5.85 +/- 0.61 vs 5.08 +/- 0.95 In(msec2), p = 0.005) and patients (5.58 +/- 1.49 versus 4.74 +/- 1.18 In(msec2), p = 0.003). There was again no significant change in the TF or LF components during tilt in either patients or controls. All frequency components were significantly decreased during submaximal exercise testing in both patients and controls. However, there was no significant difference in any of these tilt- and exercise-induced changes in HRV between normal controls and SCD survivors.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Radiological appearances of implantable defibrillator systems.

Implantable defibrillator systems have been used in over 20,000 patients worldwide. Such systems use a variety of different electrodes and the identification of these and the recognition of associated problems with them presents a challenge to the radiologist. The appearance of currently available implantable defibrillation systems and the use of radiological examination in patient follow-up and system troubleshooting is discussed based on our experience with a large population of patients receiving these devices. Radiological examination is excellent for demonstrating displacement of distortion of defibrillation electrodes, but in our experience is ineffective for the identification of lead conductor fractures.

Defibrillators, Implantable

Is there an abnormal QT interval in sudden cardiac death survivors with a "normal" QTc?

Correcting the QT interval for heart rate may mask ventricular repolarization abnormalities and may lead to a misinterpretation of the physiologic and pathophysiologic findings. In this study the QT/R-R relationship was studied in eight sudden cardiac death (SCD) survivors without overt structural heart disease and compared with eight age- and sex-matched normal subjects. All patients were in a drug-free state. The QT intervals and their preceding R-R intervals were measured on electrocardiogram (ECG) strips from 24-hour Holter recordings at hourly intervals. The differences in mean heart rate, mean QT intervals, and QTc values between SCD survivors and normal subjects were not statistically significant. There was a significant correlation between the QT and R-R intervals in normal subjects (tau = 0.71 +/- 0.13, p < 0.05) and in SCD survivors (tau = 0.79 +/- 0.07, p < 0.05). However, the regression line of the QT interval against the R-R interval was significantly (p < 0.01) altered in SCD survivors compared with normal subjects. These observations suggest that there is abnormal ventricular repolarization (QT interval) despite an apparently normal QTc using Bazett's formula in these patients. Evaluation of the QT/R-R relationship by means of 24-hour ambulatory Holter ECG monitoring may provide a useful clinical tool for the assessment of ventricular repolarization abnormalities.

Adult

Legal and ethical aspects of driving and working in patients with an implantable cardioverter defibrillator.

Automobile driving is essential to work and leisure for many people, and patients with implantable cardioverter defibrillators (ICDs) are no exception. Whether patients who may suffer sudden incapacitation should be allowed to drive raises important ethical and legal issues. The opinion of physicians regarding when or if it is safe to drive with an ICD varies, and most countries have no regulations to assist such decisions. Such regulations can best be developed by actuarial analysis of the risks involved, although the limited volume of published data on the ICD hinders this process. A policy based on very low levels of social risk from driving by patients with ICDs or a comparison with epileptic patients suggests a ban on driving for 12 to 24 months after ICD implantation. Patients who have received therapy from the ICD within this period would not be granted a driver's licence. As further data from actuarial studies become available, these guidelines could be relaxed for patients at low risk of therapy delivery.

Actuarial Analysis

Relationship between short- and long-term measurements of heart rate variability in patients at risk of sudden cardiac death.

Because of technical difficulties in analyzing heart rate variability (HRV) from ambulatory Holter recordings over 24-hour periods, short-term recordings are more practical for the clinical application of HRV. However, the relationship between short- and long-term recordings is unclear. In this study, short-term (10 min) electrocardiograms were assessed in the supine position, during passive head-up tilt and on standing in 15 patients (aged 39 +/- 14 years) with ventricular tachycardia/fibrillation not associated with coronary artery disease. Spectral HRV was computed as total frequency (TF: 0.01-1.00 Hz), low frequency (LF: 0.04-0.15 Hz), and high frequency (HF: 0.15-0.40 Hz) components. The short-term HRV parameters were compared with those obtained from long-term (24 hour) recordings from the same patients. There was a significant decrease in the HF component of HRV and a significant increase in LF/HF ratio during passive tilt or active standing compared with supine recordings, but no significant changes were observed in the TF or LF components. All frequency components of HRV for the 24-hour periods showed significant correlation with the values from short-term recordings (tau ranged from 0.67-0.87). Stepwise multivariate regression analysis showed that both the TF and HF components of HRV over 24 hours were predominantly related to the corresponding frequency components of HRV in the supine position, while the LF component of HRV over 24 hours was predominantly related to that on standing. Our observations suggest that the short-term HRV is related to the long-term value, but global HRV over 24 hours cannot completely be replaced by the short-term recordings.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Decreased heart rate variability in survivors of sudden cardiac death not associated with coronary artery disease.

BACKGROUND: Although heart rate variability has already been studied in survivors of sudden cardiac death secondary to coronary artery disease, an assessment of heart rate variability in survivors of sudden cardiac death not associated with coronary artery disease has not been made. METHODS: 10 patients with aborted sudden cardiac death not associated with coronary artery disease (seven patients with primary ventricular fibrillation and three with unclassified mild cardiomyopathy) underwent two channel 24 hour Holter monitoring in a drug free state. All subjects were in sinus rhythm and had normal atrioventricular conduction and normal cardiac function. Spectral heart rate variability was analysed on a Holter analysis system and was expressed as total (0.01-1.00 Hz), low (0.04-0.15 Hz) and high (0.15-0.40 Hz) frequency components for each hour. Heart rate variability index was calculated for the 24 hour periods. 10 age and sex matched healthy subjects were taken as a control group. RESULTS: The spectral heart rate variability over 24 hours was significantly lower in survivors of sudden cardiac death than in controls (total 38(15) v 48(14) ms; low, 25(11) v 32(13) ms; and high, 13(8) v 18(8) ms; p < 0.05 for all comparisons). The differences in the ratio of low/high (2.19(0.76) v 1.98(0.50), p = 0.132), mean heart rate (77(12) v 69(12) beats/min, p = 0.070), and heart rate variability index (38(12) v 44(16), p = 0.287) over 24 hours between survivors of sudden cardiac death and controls did not reach significance. Comparisons of the hourly heart rate variability over the 24 hour period between the two groups showed that the differences in all components of heart rate variability, low/high ratio and mean heart rate were highly significant. Furthermore, there was no significant difference in the maximum hourly heart rate variability over the 24 hour period. The minimum hourly heart rate variability was, however, significantly lower in survivors of sudden cardiac death than in controls (total, 20(8) v 28(4) ms; low, 12(6) v 17(3) ms; high, 6(2) v 8(2) ms; p < 0.05 for all comparisons). CONCLUSIONS: These findings suggest that there is abnormal autonomic influence on the heart in patients without coronary artery disease at risk of sudden cardiac death. Hourly analysis of heart rate variability throughout the 24 hour period may provide additional information important in the identification of high risk patients.

Adolescent

Effects of procainamide on the signal-averaged electrocardiogram in relation to the results of programmed ventricular stimulation in patients with sustained monomorphic ventricular tachycardia.

OBJECTIVES: The aim of this study was to assess the ability of the signal-averaged electrocardiogram (ECG) to predict the efficacy of procainamide. BACKGROUND: The main role of the signal-averaged ECG has been the identification of postinfarction patients at risk of sudden death. Prediction of the efficacy of antiarrhythmic drugs represents another potential clinical application of this technique. METHODS: The study examined the effects of procainamide on the time domain and spectral temporal analysis of the signal-averaged ECG in relation to the results of programmed ventricular stimulation studies in 31 patients with inducible sustained monomorphic ventricular tachycardia. RESULTS: Procainamide significantly prolonged the total and the initial QRS complex and low amplitude signal durations (mean +/- SD 135 +/- 30 vs. 161 +/- 46 ms, p < 0.0001; 87 +/- 16 vs. 98 +/- 20 ms, p < 0.0001, and 48 +/- 23 vs. 63 +/- 36 ms, p < 0.001, respectively) whereas the root-mean-square voltage of the total QRS complex and of the last 40 ms of the QRS complex was significantly reduced (mean +/- SD 112 +/- 36 vs. 87 +/- 36 microV, p < 0.0001; 21 +/- 19 vs. 13 +/- 12 microV, p < 0.002, respectively). The results of spectral temporal mapping of the signal-averaged ECG were similar before and after procainamide administration. Procainamide prevented the inducibility of sustained ventricular tachycardia or prolonged the cycle length of ventricular tachycardia by > or = 100 ms in 16 patients (52%) (responders). The fractional prolongation of the total QRS duration was significantly greater in responders (26 +/- 15%) than in nonresponders (10 +/- 10%) (p < 0.002) and, when this prolongation was > or = 15%, identified responders with a sensitivity of 94%, a specificity of 87% and an overall predictive accuracy of 90%. CONCLUSIONS: The effects of procainamide on inducibility of ventricular tachycardia during programmed ventricular stimulation can be predicted by the degree of drug-induced prolongation of the signal-averaged QRS complex.

Aged

Implications for present and future applications of the implantable cardioverter-defibrillator resulting from the use of a simple model of cost efficacy.

OBJECTIVE: To develop a model to assess the cost-efficacy of the implantable cardioverter defibrillator to prevent sudden death. The model must be sufficiently flexible to allow the use of cost and survival figures derived from different sources. SETTING: The study was conducted in a teaching hospital department of cardiology with experience of 40 implantable cardioverter defibrillator implants and a large database of over 500 survivors of myocardial infarction. PROCEDURE: The basic costs of screening tests, stay in hospital, and purchase of implantable cardioverter defibrillators were derived from St George's Hospital during 1991. To assess the cost-efficacy of various strategies for the use of implantable cardioverter defibrillators, survival data taken from published studies or from our own database. Implications of the national cost of the various strategies were calculated by estimating the number of patients a year requiring implantation of a defibrillator if the strategy was adopted. RESULTS: Use of implantable cardioverter defibrillators in survivors of cardiac arrest costs between 22,400 pounds and 57,000 pounds for each year of life saved. Most of the strategies proposed by the current generation of implantable cardioverter defibrillator trials have cost efficacies in the same range, and adoption of any one of these strategies in the United Kingdom could cost between 2 million pounds and 100 million pounds a year. Future technical and medical developments mean that cost-efficacy may be improved by up to 80%. Due to the limitations of screening tests currently available restriction on the use of implantable cardioverter defibrillators to those groups where it seems highly cost-effective will result in a small impact on overall mortality from sudden cardiac death. CONCLUSION: Present and possible future applications of the implantable cardioverter defibrillator seem expensive when compared with currently accepted treatments. Technical and medical developments are, however, likely to result in a dramatic improvement in cost efficacy over the next few years.

Clinical Trials as Topic

Dental amalgam. The state of the art and science.

When you balance the benefits and liabilities of a modern dental amalgam, it is one of the materials that comes closet to being an ideal restorative. Its numerous clinical advantages have, in the past, made it a standard in dental care. The profession's and public's awareness of the issues surrounding the mercury content, coupled with the biased reporting of the controversy by less than responsible journalists, have served to impung the material. The dental profession has used the material successfully in its present form for almost 100 years. There are still valid questions about the material that require further scientific investigation. Investigators continue to make improvements in the alloy's strength and handling properties while limiting the mercury-release potential of the material. As we move into the twenty-first century, we are again told we will soon have a suitable replacement for dental amalgam. That is an often repeated promise for this multifunctional product. Time and sound research into the longevity and liabilities of all restorative materials as applied in the office of the general practitioner will tell us if amalgam is or is not going to disappear from the dental armamentarium in the near future.

Dental Amalgam

The effect of slot preparation length on the transverse strength of slot-retained restorations.

An in vitro study was conducted (1) to compare fracture strength of amalgam restorations retained with retentive slots of different lengths when stressed with a transverse force, (2) to determine if beveling the slot preparation resulted in an increase in fracture resistance to a transverse force, and (3) to evaluate the incidence of unrestorable tooth fracture as it relates to slot preparation length. Six groups of 10 specimens were prepared with slots of increasing length, with each specimen receiving four slots of equal length. Slot preparations in group 6 were beveled. Results showed that shorter slot preparations provided statistically equal amounts of resistance to a transverse force as did the longer preparations. Beveling the slot preparation did not significantly increase fracture strength. Specimens restored with longer slot preparations failed unrestorably more often than restorations retained with shorter slot preparations.

Dental Amalgam

Adhesive properties of modified glass-ionomer cements.

The incorporation of water-soluble polymers and/or vinyl monomers into glass-ionomer cements can yield toughened "hybrid cement-composites". This study compared a commercial water-hardening glass-ionomer cement and seven experimental hybrids in their bonding to both dentin and Silar composite. The cements were sanded and phosphoric-acid-etched or left with an unaltered matrix-formed surface when adhesion to composite was tested. The seven hybrids included: 15% 2-hydroxyethyl methacrylate (HEMA) with appropriate initiators/activators, 29% HEMA, 27% HEMA + 0.5% polyacrylic acid (PAA), 0.5% PAA, 1.5% PAA, 2.5% polyvinyl alcohol, and 2.5% gelatin. Acceptable bond strengths to applied composite and to dentin were observed for most of the modified hybrid cements. There were higher bond strengths with composite when the hybrids were left unetched. Bonding of some unetched, HEMA-containing cements achieved bond strengths (29% HEMA, 10.09 MPa) significantly higher than those of the unmodified cement (4.92 MPa). Resin-modified cements may promote better bonding by improved interaction and compatibility with the resin component of the composite.

Acid Etching, Dental

Prediction of antiarrhythmic efficacy of class I and III agents in patients with ventricular tachycardia by signal-averaged ECG analysis.

The effects of procainamide and dofetilide (pure Class III antiarrhythmic agent) on the signal-averaged ECG (SAECG) were examined in relation to the results of programmed ventricular stimulation studies in 25 patients with inducible sustained monomorphic ventricular tachycardia. Procainamide prolonged significantly the total QRS and low amplitude signal durations (140 +/- 31 msec vs 166 +/- 48 msec, P < 0.0001; 50 +/- 25 msec vs 65 +/- 38 msec, P < 0.002, respectively) whereas the root mean square voltage of the last 40 msec of the QRS complex was significantly reduced (22 +/- 21 microV vs 13 +/- 12 microV, P < 0.006). Procainamide was effective (prevention of the inducibility of sustained ventricular tachycardia or prolongation of the cycle length of ventricular tachycardia by > 100 msec) in 15 of 27 drug trials. Of the procainamide induced SAECG changes, the fractional prolongation of the total QRS duration was the best parameter that identified effectively treated patients (24% +/- 16% in responders vs 10% +/- 11% in nonresponders, P < 0.014). A fractional prolongation of the total QRS duration by > 15% identified effectively treated patients with a sensitivity of 87%, specificity of 81%, and an overall predictive accuracy of 84%. Dofetilide did not change the SAECG, and no SAECG parameter predicted the results of programmed ventricular stimulation. The effects of both drugs on the spectral analysis (area ratios) and on the spectral temporal mapping (the values of normality factor) of the SAECG were not consistent. In conclusion, antiarrhythmic efficacy of procainamide can be predicted by the degree of drug induced prolongation of the signal-averaged QRS complex.(ABSTRACT TRUNCATED AT 250 WORDS)

Anti-Arrhythmia Agents