PubMed Health⌕ Search

Biomedical subjects

M H Godinho

Publications and source records attributed to M H Godinho.

2 recordsLinked to original sources

Study of micro and nano surface structures from UV irradiated urethane/urea elastomers.

In this work we address new results obtained with a thin free standing flexible film (approximately 120 microm) of a urethane/urea copolymer related to the formation of micro and nano size structures [M.H. Godinho, A.C. Trindade, J.L. Figueirinhas, L.V. Melo, P. Brogueira, Synthetic Metals, 147(1-3), 209 (2004); M.H. Godinho, A.C. Trindade, J.L. Figueirinhas, L.V. Melo, P. Brogueira, Molecular Crystals and Liquid Crystals (2005)]. The copolymer was synthesized from a polypropylene oxide-based prepolymer with three isocyanate terminal groups (PU) and polybutadienediol (PBDO) with PBDO content of 40% wt. After casting and curing the film was cut into different samples and each exposed to UV radiation for different periods of time; 23, 25, 26, 31 and 49 h (lambda=254 nm) and later extracted with toluene and dried. The dried films were then studied by polarising optical microscopy (POM), small angle light scattering (SALS) and the surfaces exposed to UV radiation analyzed by means of atomic force microscopy (AFM). Before extraction with toluene a nanometer-flat surface, characterized by a mean roughness value Ra=0.59 nm, was obtained. Depending on exposure time to UV radiation and after extraction with toluene a corrugated surface, with features mum-sized in all axes, resulting in an increase of the overall mean roughness value to Ra=50.7 nm, starts to develop after 25 h of exposure time. This work gives evidence of the non-monotonous time behavior of the wrinkled surface growth that develops under the action of ultraviolet radiation. As the exposure time increases the free-standing films directly exposed surfaces show a decreasing density of the structures observed and an increasing characteristic peak-to-valley height. The peak-to-valley height measured for samples exposed for 23, 25, 26, 31 and 49 h, respectively 193, 383, 381, 1550 and 2039 nm and the corresponding mean roughness values are Ra=50.7 nm, 105.4, 116.8, 438.3 and 515.4 nm, respectively. Between 26 and 31 h exposure time a leap in both values, peak-to-valley and Ra, was observed. The sudden increase in these values is correlated to fabrication of wrinkles by uniaxially stretching PU/PBDO elastomer films.

Biocompatible Materials↗

Staphylococcus epidermidis adhesion on modified urea/urethane elastomers.

Block urea/urethane co-polymer films present elastomeric properties with the possible tuning of their surface properties within a wide range and are therefore considered relevant surfaces for possible medical applications. In particular, thin free standing films of urea/urethane elastomers with two soft segments, polypropylene oxide and more hydrophobic polybutadiene, develop multistable states with surface topography features with remarkable regularity. Moreover, complex surface structures may be obtained by UV radiation treatment followed by suitable mechanical action and also by extraction of the elastomer with a suitable solvent. In the present work, different modified elastomer samples were assayed for Staphylococcus epidermidis adhesion during 2 h and the extent of bacterial adhesion was evaluated by automatic cell enumeration. Bacterial adhesion assays demonstrate that the typical trend relating the increase in the number of adhered bacteria with the increase of the surface roughness does not hold for all materials. Results may be interpreted taking into account both the surface topography and the different types of micro-phase segregation of hydrophobic and hydrophilic parts of the elastomer.

Bacterial Adhesion↗