M Höher

Publications and source records attributed to M Höher.

At least 19 recordsLinked to original sources

The future of cardiovascular imaging and non-invasive diagnosis: a joint statement from the European Association of Echocardiography, the Working Groups on Cardiovascular Magnetic Resonance, Computers in Cardiology, and Nuclear Cardiology, of the European Society of Cardiology, the European Association of Nuclear Medicine, and the Association for European Paediatric Cardiology.

Advances in medical imaging now make it possible to investigate any patient with cardiovascular disease using multiple methods which vary widely in their technical requirements, benefits, limitations, and costs. The appropriate use of alternative tests requires their integration into joint clinical diagnostic services where experts in all methods collaborate. This statement summarises the principles that should guide developments in cardiovascular diagnostic services.

Biomedical Research↗

[Rare cause of long QT and resuscitation-requiring torsade de pointes tachycardia].

A 62 year old patient underwent an intraoperative pancreas biopsy because of a pancreas head process. On 13(th) and 20(th) postoperative day a short syncope episode occurred. On that days calcium blood levels were 1,82 and 1,74 mmol/l, respectively. On 13(th) postoperative day QT(c) interval was 565 ms. On 26(th) postoperative day the patient was resuscitated because of torsade de pointes tachycardia. His actual calcium blood level was 1,47 mmol/l and QT(c) interval 627 ms. An extensive diagnostic work-up revealed no evidence of cardiac disease. After calcium substitution QT interval normalised. During a follow-up period of 16 months the patient remained without symptoms.

Calcium↗

Assessment of left ventricular function with steady-state-free-precession magnetic resonance imaging. Reference values and a comparison to left ventriculography.

UNLABELLED: Ejection fraction (EF) and end-diastolic and end-systolic volume index (EDVI/ ESVI) derived from ventriculography are important prognostic parameters. Cine magnetic resonance imaging (MRI) using a steady-state, free-precession sequence (SSFP) offers excellent delineation of the endocardial borders and highly reproducible and accurate results for cardiac volumes. We evaluated MRI volumetry against routine x-ray ventriculography. In 200 patients EF, EDVI and ESVI were measured with MRI volumetry and x-ray ventriculography. The same MRI protocol was applied to 102 healthy persons in order to establish reference values. In healthy subjects mean EF was 68.8% +/- 5.4% (range 59-84%), mean EDVI 69 +/- 10 (43-90) and mean ESVI 22 +/- 5.8 (10-35 ml). In the patients, overall correlation (Spearman's R) of MRI with ventriculography was 0.86 for EF, 0.77 for EDVI and 0.88 for ESVI. For postextrasystolic beats (38% of the measurements), R was 0.73/0.65/0.73 for EF/EDVI/ESVI. MRI correlated best with biplane ventriculography during sinus rhythm (0.96/0.85/0.93); the worst correlation (0.78/0.81/0.83) resulted from patients with wall motion abnormalities in comparison to monoplane x-ray ventriculography. CONCLUSION: Contemporary MRI volumetry compares well to invasive data obtained under optimal conditions. In view of the known limitations of single plane ventriculography, MRI seems to allow exact volumetry independent from regional wall motion abnormalities.

Cardiac Catheterization↗

[High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system].

PURPOSE: To evaluate magnetic field interactions of commonly used biomedical implants at 3.0 Tesla. MATERIALS AND METHODS: Fourteen aneurysm clips designed for permanent placement in intracranial aneurysms, 19 coronary artery stents and 20 iliac artery stents were evaluated in an actively shielded compact 3.0 T MR system (Intera, Philips Medical Systems, Best, The Netherlands, length of magnet 1.57 m). The magnetic deflection forces (translational movement) were evaluated as follows: The implants were suspended by a fine string and placed in the magnet bore at the location of the maximum magnetic field gradient. The translational forces F (z) were calculated from the measured angle of deflection from the vertical axis. The magnetic field-induced torque (rotational forces) was evaluated as follows: Each implant was placed in the center of the magnetic bore parallel to the static magnetic field B0 (position 0 degrees ). Any possible displacement of the implant was noted on a millimeter scale and any torque qualitatively evaluated using a 5 point grading scale (0: no torque; + 4: very strong torque). The implant was turned in steps of 45 degrees, and the procedure was repeated to encompass a full 360 degrees rotation. RESULTS: In 52 of the 53 devices tested, the deflection force (deflection angle: range 0-21 degrees, translational force: range 0-3.8 mN) was less than the gravitational force (i.e., the implant's weight). These devices (n = 52/53) did not show any alignment to or rotation in the magnetic field at any of the various 45 degrees -increment positions corresponding to a qualitative torque evaluation of grade 0/4. One device (n = 1/53), an iliac artery stent made of stainless steel (Zenith, Cook, Mönchengladbach, BRD), was found to have deflection forces (deflection angle 88 degrees translational force 299 mN) greatly exceeding the gravitational force as well as a pronounced torque (grade 4/4). CONCLUSION: Out of 53 biomedical implants evaluated for magnetic field interactions at 3.0 T, one iliac artery stent made of stainless steel was found to be potentially unsafe based on ASTM criteria. MR imaging at 3.0 Tesla may be performed safely in patients with any of the other 52 different implants evaluated in this study with respect to magnetic field translational attraction and torque.

Alloys↗

[Effect of molsidomine on rheological parameters and the incidence of cardiovascular events].

BACKGROUND AND OBJECTIVE: In-vitro studies revealed that nitric oxide (NO) may affect rheological parameters. We studied the effect of highly-dosed NO-donor molsidomine on blood rheology and the impact of rheological parameters on the incidence of severe cardiovascular events. PATIENTS AND METHODS: In this randomized, placebo-controlled and double-blind trial 166 patients (60 +/- 10 years) with stable angina pectoris and coronary intervention received molsidomine 3 x 8 mg t. i. d. (controlled release tablets) or placebo for 6 months. Patients with inflammatory/neoplastic disorders or elevated values of C-reactive protein were excluded from analysis. A rheological profile (plasma viscosity, blood viscosity, aggregation and flexibility of erythrocytes, filtrability of leukocytes, fibrinogen levels) was done initially and after 6 months. Adverse cardiovascular events (death, myocardial infarction, stroke, coronary/peripheral revascularization) were recorded during 12 months. Furthermore, the impact of rheological parameters regarding the occurrence of severe cardiovascular events (death, myocardial infarction, stroke) was evaluated during a follow-up of median 38 months. RESULTS: The data of 137 patients (n = 71 placebo, n = 66 molsidomine) were analysed. The difference of rheological parameters between the two measurements did not vary between the two groups. Analysis of event-free survival with Kaplan-Meier technique revealed no difference between the two groups. Multivariate Cox regression analysis with adjustment for diabetes mellitus, smoking and therapy with statin showed a significant association of fibrinogen and plasma viscosity with the occurrence of severe cardiovascular events. CONCLUSION: Treatment with molsidomine 3 x 8 mg/day for 6 months does not improve blood rheology or reduce cardiovascular events. But elevated levels of fibrinogen and plasma viscosity were associated with the occurrence of severe cardiovascular events.

Blood Viscosity↗

Interventional nuclear medicine in the prevention of restenosis following angioplasty.

Restenosis is an unsolved clinical and economic limitation of angioplasty. Local irradiation is a new concept to overcome this problem. The magnitude of this health problem becomes apparent when one recognizes that 166132 percutaneous transluminal coronary angioplasty (PTCA) procedures were performed in Germany in 1999. Each angioplasty has subsequent costs of 6384 DM, which can be reduced to 2161 DM by 50% restenosis reduction due to irradiation [1]. The number of diagnostic and therapeutic procedures is growing by at least 10% per year.

Angioplasty↗

Validation of myocardial blood flow estimation with nitrogen-13 ammonia PET by the argon inert gas technique in humans.

We simultaneously determined global myocardial blood flow (MBF) by the argon inert gas technique and by nitrogen-13 ammonia positron emission tomography (PET) to validate PET-derived MBF values in humans. A total of 19 patients were investigated at rest (n = 19) and during adenosine-induced hyperaemia (n = 16). Regional coronary artery stenoses were ruled out by angiography. The argon inert gas method uses the difference of arterial and coronary sinus argon concentrations during inhalation of a mixture of 75% argon and 25% oxygen to estimate global MBF. It can be considered as valid as the microspheres technique, which, however, cannot be applied in humans. Dynamic PET was performed after injection of 0.8 +/- 0.2 GBq 13N-ammonia and MBF was calculated applying a two-tissue compartment model. MBF values derived from the argon method at rest and during the hyperaemic state were 1.03 +/- 0.24 ml min-1 g-1 and 2.64 +/- 1.02 ml min-1 g-1, respectively. MBF values derived from ammonia PET at rest and during hyperaemia were 0.95 +/- 0.23 ml min-1 g-1 and 2.44 +/- 0.81 ml min-1 g-1, respectively. The correlation between the two methods was close (y = 0.92x + 0.14, r = 0.96; P < 0.0001). No indication was found for limited extraction of ammonia in the myocardium. The high concordance of global MBF values derived with argon and ammonia indicates that the implicit correction of spillover and recovery effects, incorporated in the model by including an effective blood volume parameter, works correctly quantitatively. Our data provide the previously missing human validation of MBF measurements from 13N-ammonia PET.

Adenosine↗

Angioscopic predictors of restenosis following coronary angioplasty--the impact of yellow smooth plaques.

Despite angioscopy being used for more than 10 years, data regarding the prognostic significance are still limited. This study evaluated the prognostic relevance of the angioscopic lesion morphology and plaque colour on restenosis rate following coronary angioplasty. Out of 66 patients with coronary angioscopy prior to an angioplasty procedure, 46 patients with successful balloon dilation and 16 patients with stenting were included into the study. Angioscopic plaque morphology and plaque colour were correlated with the anginal status, the angiographic lesion morphology, the procedural result, and the restenosis rate during six months follow-up. Clinical follow-up was obtained from all patients, re-angiography was performed in 61%. Angioscopically complicated lesions were more frequent in patients with unstable versus stable angina (63% versus 28%, p < 0.005) and ACC/AHA type B2/C versus A/B1 stenoses (86% versus 7%, p < 0.03). In addition yellow plaques were more often seen in unstable versus stable angina (80% versus 50%, p < 0.02) and in type B2/C versus A/B1 lesions (81% versus 47%, p < 0.005). There were no deaths or myocardial infarctions during follow-up. Restenosis (n = 11) occurred significantly more frequent in patients with smooth, yellow lesions (37%) compared to all other lesion morphologies (9%, p < 0.02). Logistic regression analysis revealed angioscopically smooth, yellow plaques (p < 0.05) and angiographically type B2/C lesions (p < 0.03) as independent predictors for restenosis. We conclude that angioscopically smooth, yellow plaques covered by an intact inner vessel surface are associated with a higher incidence of restenosis following coronary angioplasty, potentially indicating a higher proliferative response after a mechanical trauma of such lesions.

Aged↗

Endovascular irradiation with the liquid beta-emitter Rhenium-188 to reduce restenosis after experimental wall injury.

OBJECTIVE: Postinterventional irradiation is a new therapeutic concept in the prevention of restenosis. The liquid beta-emitter Rhenium-188 allows endovascular brachytherapy using a conventional balloon catheter without the problem of centering the radiation source. In an animal model of restenosis the feasibility and the dose dependent effect of intravascular brachytherapy with a Rhenium-188 filled balloon catheter was investigated. METHODS: In 68 male New Zealand White rabbits after endothelial denudation of the right common carotid artery with a Fogarty catheter, endovascular irradiation was performed with a Rhenium-188 filled 3.0-mm balloon catheter using different dosages (0, 7.5, 15, 30, 45 and 60 Gy at the surface of the vessel). Then 4 weeks after the intervention the vessels were excised and histologically analyzed. RESULTS: Whereas at 7.5 Gy the intimal area (median [first quartile; third quartile]) did not differ significantly from the control (0.46 mm(2) [0.33 mm(2), 0.75 mm(2)] vs. 0.49 mm(2) [0.34 mm(2), 0.66 mm(2)]), neointimal hyperplasia was decreased significantly at 15 Gy (0.15 mm(2) [0.04 mm(2), 0.17 mm(2)]) and 30 Gy (0.07 mm(2) [0.04 mm(2), 0. 10 mm(2)]), and completely inhibited at the highest dosages (45 Gy: 0 mm(2) [0 mm(2), 0.04 mm(2)]; 60 Gy: 0 mm(2) [0 mm(2), 0.01 mm(2)]). CONCLUSIONS: Catheter transmitted endovascular irradiation with the liquid beta-emitter Rhenium-188 after vascular injury is feasible and effectively reduced neointimal hyperplasia in hypercholesterolemic rabbits. A significant reduction of the neointimal formation could be found already at a radiation absorbed dose of 15 Gy at the vessel surface. Following a surface dosage of 45 Gy the proliferative response to the vessel injury is almost completely abolished.

Angioplasty, Balloon↗

Comparison of the heparin coated vs the uncoated Jostent--no influence on restenosis or clinical outcome.

AIMS: Heparin coating of stents is thought to reduce stent thrombosis and restenosis rates. However, clinical data comparing coated and uncoated stents of the same model are lacking. We compared the heparin coated (C) and the uncoated (U) version of the Jostent stent with regard to the clinical and angiographic outcome after 6 months. METHODS AND RESULTS: Provisional stenting was done in 277 patients and 306 lesions; only 40 were Benestent-II like lesions. Delivery success rate was 98.4%. Both groups (C/U: n=156/150 lesions) were comparable in clinical and procedural data. Post stenting, reference diameter (C/U: 2.68+/-0.56/2.66+/-0.53 mm) and minimal lumen diameter did not differ (C/U: 2.48+/-0.47/2.48+/-0.52 mm). During follow-up the rate of subacute stent thrombosis (C/U: 1.9%/1.3%) and myocardial infarction did not differ. Angiography at the 6-month follow-up (79.4%) revealed no difference in restenosis rate (C/U: 33.1%/30.3%). Risk factors for restenosis were a type B2/C lesion (P<0.02), a stented segment longer than 16 mm (P<0.006) and a stent inflation pressure <14 bar (P<0.0063). CONCLUSION: Corline heparin coating of the Jostent has no impact on the in-hospital complication rate, stent thrombosis or restenosis. The Jostent design gives a high procedural success rate and satisfying result at 6 months in an everyday patient population undergoing provisional stenting.

Anticoagulants↗

Intracoronary beta-irradiation with a liquid (188)re-filled balloon: six-month results from a clinical safety and feasibility study.

BACKGROUND: Coronary irradiation is a new concept to reduce restenosis. We evaluated the feasibility and safety of intracoronary irradiation with a balloon catheter filled with (188)Re, a liquid, high-energy beta-emitter. METHODS AND RESULTS: Irradiation with 15 Gy at 0.5-mm tissue depth was performed in 28 lesions after balloon dilation (n=9) or stenting (n=19). Lesions included 19 de novo stenoses, 4 occlusions, and 5 restenoses. Irradiation time was 515+/-199 seconds in 1 to 4 fractions. There were no procedural complications. One patient died of noncardiac causes at day 23. One asymptomatic patient refused 6-month angiography. Quantitative angiography after intervention showed a reference diameter of 2. 77+/-0.35 mm and a minimal lumen diameter of 2.36+/-0.43 mm. At 6-month follow-up, minimal lumen diameter was 1.45+/-0.88 mm (late loss index 0.57). Target lesion restenosis rate (>50% in diameter) was low (12%; 3 of 26). In addition, we observed 9 stenoses at the proximal or distal end of the irradiation zone, potentially caused by the short irradiation segment and the decreasing irradiation dose at its borders ("edge" stenoses). The total restenosis rate was 46% and was significantly lower (29% vs 70%, P=0.042) when the length of the irradiated segment was more than twice the lesion length. CONCLUSIONS: Coronary irradiation with a (188)Re-filled balloon is technically feasible and safe, requiring only standard percutaneous transluminal coronary angioplasty techniques. The target lesion restenosis rate was low. The observed edge stenoses appear to be avoidable by increasing the length of the irradiated segment.

Adolescent↗

Cardiac vulnerability assessment from electrical microvariability of high-resolution electrocardiogram.

Patients susceptible to malignant arrhythmias often have an increased beat-to-beat variation of the T-wave of the electrocardiogram. Variability analysis of the T-wave is increasingly used for non-invasive risk assessment. The aim of this study is to evaluate intra-QRS beat-to-beat signal variation and to compare it to ST-T variation. The beat-to-beat, microvolt variation of the QRS and the ST-T segment from 44 patients with coronary heart disease at high risk of suffering from malignant arrhythmias and from 51 healthy volunteers are compared. Variation analysis is carried out on 250 consecutive sinus beats from high-resolution electrocardiograms. The individual beats are filtered using a waveform-independent, cubic spline-filter. A variability index of the QRS and ST-T segments is calculated as the integrated standard deviation of corresponding samples inside the area of interest. Patients at risk of suffering from malignant arrhythmias have a significantly higher variability index of both the QRS (median 44.5 ms against 34.7 ms, p < 0.001) and the ST-T segment (median 20.5 ms against 9.8 ms, p < 0.001) compared to the group of healthy subjects. The discriminative ability of the odds variability indices of the QRS and ST-T segments are not statistically different, the ratios being 7.8 (QRS) and 12.6 (ST-T). We conclude that patients at high risk of suffering from malignant arrhythmias are characterised by an increased beat-to-beat microvolt variation of both the QRS and the ST-T segment. Further studies are necessary to evaluate the prognostic potential of depolarisation variability.

Adult↗

Endovascular brachytherapy for the prevention of restenosis after angioplasty.

Restenosis is an unsolved clinical and financial limitation of angioplasty. Local irradiation is a new approach for the reduction of restenosis. Several animal studies have demonstrated the effective inhibition of arterial neointimal proliferation by percutaneous or endovascular irradiation. High-dose-rate irradiation from gamma and beta sources can be applied from radioactive wires or seeds and from liquid beta-emitter-filled balloon catheters. Dosimetric calculations have been performed for all relevant radionuclides. An effective dose can be applied within 10 min to the treated arteries. Beta-emitters are characterized by a low tissue penetration, which simplifies radiation protection but complicates the achievement of a homogeneous dose distribution without centering of the irradiation source. Gamma-emitters are characterized by deep tissue penetration and delivery of almost the same dose to all vessel layers; however, considerable care with regard to radiation protection of the environment is required if gamma-emitters are used. The liquid-filled balloon ensures a homogeneous dose delivery due to the self-centring irradiation source but entails the possibility of radioactivity incorporation in the event of balloon rupture. The most attractive radionuclide for this purpose is rhenium-188, which is available from the 188W/188Re generator system. Radiation exposure after accidental incorporation can be limited by chelation with mercaptoacetyltriglycine or by subsequent oral administration of perchlorate. Initial clinical trials have demonstrated the feasibility of the various irradiation techniques and yielded encouraging results. The use of unsealed radioactivity in a balloon catheter involves the nuclear medicine physician in this new field of therapy. This review discusses the concepts, the radiotracers and the results of animal experiments and early clinical trials in the field of endovascular irradiation employed as a possible means to prevent restenosis after angioplasty.

Angioplasty, Balloon, Coronary↗

[Risk stratification after myocardial infarct].

In industrialized countries the rate of sudden cardiac death remains unchanged. The most frequently encountered structural heart disease in these patients is coronary artery disease. Despite the era of thrombolytic therapy of acute myocardial infarction patients carry an increased risk of sudden cardiac arrhythmogenic death within a time period of one to two years following the acute event. Therefore, risk stratification post-MI before patient discharge is furthermore mandatory. The spectrum of non-invasive techniques for risk stratification includes the clinical risk profile, measurement of left ventricular global function (LV ejection fraction), the resting ECG (QT dispersion), an ECG stress test (detection and severity of myocardial ischemia), ambulatory ECG monitoring (number and type of ventricular arrhythmias), surface high resolution ECG (detection of ventricular late potentials), measurement of T wave alternans (TWA, alternans ratio), and measurements of the activity and balance of the autonomous nervous system (heart rate variability, baroreflex sensitivity = BRS). Programmed ventricular stimulation (PVS) serves as an invasive risk stratification technique (detection of an arrhythmogenic substrate). The prognostic power of the non-invasive techniques is limited; in general, the prognostic value of a negative test is reasonably high (90 to 100% depending on the test used), whereas the prognostic value of a positive test is rather low (4 to 42% depending on the test used). Combining several non-invasive tests may significantly improve the positive predictive value above 50%, but this goes along with a significant decreases of sensitivity below 50%. Therefore, a combination of several non-invasive tests (detection and exclusion of a large number of low-risk individuals) with the invasive method of PVS (detection of an arrhythmogenic substrate, i.e. a high-risk patient) seems reasonable, as has been convincingly shown by several smaller prognostic studies.

Arrhythmias, Cardiac↗

Aortic regurgitant flow by color Doppler measurement of the local velocity 7 mm above the leak orifice--Part 2: Comparison with cardiac catheterization.

AIMS: An in vitro study of the flow convergence region in aortic regurgitation has shown that regurgitant flow rate can be derived from the local velocity V(7 mm) at 7 mm distance above the leak orifice. This clinical study was performed to test this method in patients. METHODS AND RESULTS: In 67 patients with aortic regurgitation, the flow convergence region was imaged by color Doppler. By analogy with the afore mentioned in vitro study, velocity profiles of the acceleration across the flow convergence region were read from the color maps. The profiles were fitted by using a multiplicative regression model. The V(7 mm) was read from the regression curve, and instantaneous regurgitant flow Q was derived from the V(7 mm) with the equation developed in vitro (Q = V(7 mm).cm2/0.28). Q showed a close association with the angiographic grade. Q-derived regurgitant stroke volume correlated significantly with invasive measurements by the angio-Fick method (r = 0.897, SEE = 19.9 ml, y = 0.88x + 5.9 ml). CONCLUSIONS: Within the color Doppler flow convergence region of aortic regurgitation, the local velocity at 7 mm distance to the leak reflects regurgitant flow rate.

Adult↗

A human arterial organ culture model of postangioplasty restenosis: results up to 56 days after ballooning.

BACKGROUND: Restenosis is a reparative process that is activated in response to injury induced by angioplasty. Despite numerous experimental models of restenosis the number of human arterial organ culture systems is very limited and long-term experiences do not exist. METHODS AND RESULTS: During routine nephrectomies parts of the renal arteries of 88 patients were extracted, 47 were suitable for organ culture preparations. Sections were made at 3 mm intervals perpendicular to the vessel wall axis. The arterial segments were treated with 3 mm standard balloon-catheters (Medtronic 14K2030E) for 60 s with 3, 6, 9, and 12 bar. After angioplasty, the organ segments were cultured in a mixture of Waymouth's MB 752/1 and Ham F-12, supplemented with 15% fetal calf serum. After 0, 4, 14, 21, 28, and 56 days the organ cultures were fixed in 4% para-formaldehyde and embedded in paraffin. After staining with a modified elastica-van Gieson technique the intimal wall thickening was analyzed with a computerized morphometric system. For the identification of smooth muscle cells (SMC) a monoclonal antibody against smooth muscle alpha-actin was used. Endothelial cells were identified using an anti-human von Willebrand factor. To determine the number of cells undergoing DNA synthesis, bromodeoxyuridine (BrdU), a thymidine analogue, was added to the culture media 18 h prior to fixation. BrdU was detected with a monoclonal antibody, as secondary antibody a biotinylated horse-anti-mouse antibody was used. After 14, 21, and 28 days in culture BrdU-positive cells were detected in the neointima of the organ cultures, indicating mitotic activity in this area. After 28 and 56 days in culture a clear increase of neointimal thickening was found in the morphometric analysis. By positive reaction with antibodies against smooth muscle alpha-actin these cells were partly identified as SMC. CONCLUSIONS: The organ culture model offers opportunities for in vitro investigations of postangioplasty restenosis. The data emphasize the importance of a relatively late proliferative response of SMC in the human arterial organ culture model.

Adult↗

A randomized trial of elective stenting after balloon recanalization of chronic total occlusions.

OBJECTIVES: The aim of this study was to assess the role of Wiktor stent implantation after recanalization of chronic total coronary occlusions with regard to the clinical and angiographic outcome after six months. BACKGROUND: Beside the common use of stents in clinical practice, the number of stent indications proven by randomized trials is still limited. METHODS: Eighty-five patients with a thrombolysis in myocardial infarction grade 0 chronic coronary occlusion were examined. After standard balloon angioplasty, the patients were randomly assigned to stent implantation, or percutaneous transluminal coronary angioplasty (PTCA) alone (no further intervention). Quantitative coronary angiography was performed at baseline and after six months. RESULTS: The minimal lumen diameter did not differ immediately after recanalization (stent group 1.61 +/- 0.30 mm vs. PTCA group 1.65 +/- 0.36 mm), and increased after stent implantation to 2.51 +/- 0.41 mm. After six months, the stent group still had a significantly greater lumen (1.57 +/- 0.59 vs. 1.06 +/- 0.90 mm; p < 0.01) and a significantly lower restenosis and reocclusion rate (32% and 3%) compared with the PTCA group (64% and 24%); restenosis analysis according to treatment was 72% (PTCA) versus 29% (stent, p < 0.01). Late loss was equal in both groups. At follow-up, the stent patients had a better angina class (p < 0.01), and fewer cardiac events (p < 0.03). A meta-analysis including this trial and three other controlled trials with the Palmaz-Schatz stent showed concordant results. CONCLUSIONS: Stent implantation after reopening of a chronic total occlusion provides a better angiographic result, corresponding to a better clinical outcome with fewer recurrence of symptoms and reinterventions after six months.

Adult↗