PubMed Health⌕ Search

Biomedical subjects

M Haacke

Publications and source records attributed to M Haacke.

4 recordsLinked to original sources

MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesions.

A new technique for detecting vascular malformations, high-resolution BOLD venography (HRBV), is described. This technique relies on the BOLD principle for detecting deoxygenated blood in low-flow malformations. HRBV images are acquired using a modified 3D gradient-echo with voxel volumes of 0.5 x 0.5 x 2 mm3. The magnitude data are masked with the phase images to enhance visibility of the venous structures and are displayed using the minimum intensity projection. Preliminary results for 10 patients show that HRBV is more sensitive in detecting cavernomas than is T2-weighted imaging, and lesions that are presumed to be telangiectasias are detected only with this technique.

Brain↗

[Increase of connective tissue in rat hearts under exposure to noise and with magnesium deficiency (author's transl)].

Only a small amount of noise caused, combined with a nutritional Mg deficiency, a significant increase of collagen in the myocard of rats. While Mg deficiency or noise each for its own had no effect, the combination of both had a noxious effect. The results of these experiments give a hint to a correlation between collagen-increase in the myocard and an increase of urinal Catecholamine during the same time.

Animals↗

Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients.

OBJECTIVE: Our goal was to determine the feasibility of using an intravascular MR contrast agent to improve 3D MRA. MATERIALS AND METHODS: Three-dimensional TOF MRA was performed in nine patients both prior to and following the administration of an ultrasmall particle superparamagnetic iron oxide contrast agent (AMI 227). The lengths of both renal arteries were measured from the maximum intensity projection (MIP) images as well as the individual partitions. Seven of these patients also were studied by a 3D coronary artery MRA sequence. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements of the right coronary artery were determined both prior to and following the administration of AMI 227. Statistical analysis of both renal artery lengths and right coronary SNR and CNR was performed using a one tailed paired t test comparing pre- and postcontrast images. RESULTS: The renal artery lengths significantly increased (right and artery: 30%, p = 0.001; left renal artery: 25%, p < 0.008) when measured from the individual axial slice partitions. No significant increase in length was observed on the MIP images following contrast. In the right coronary artery, the SNR increased by an average of 80% (p = 0.008) and CNR increased by an average of 109% (p = 0.007). Increased background signal and superimposed venous structures reduced the measurable lengths of the renal arteries from the MIP images. CONCLUSION: These studies support the hypothesis that 3D MRA in the body will benefit from the use of intravascular contrast agents. Nevertheless, conventional MIP processing is unable to reveal the full advantage of the contrast improvement.

Contrast Media↗