3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

This study aimed to evaluate the influence of a new navigator technique (3D MAG) on navigator efficiency, total acquisition time, image quality and diagnostic accuracy. Fifty-six patients with suspected coronary artery disease underwent free breathing navigator gated coronary MRA (Intera, Philips Medical Systems, 1.5 T, spatial resolution 0.9x0.9x3 mm3) with and without 3D MAG. Evaluation of both sequences included: 1) navigator scan efficiency, 2) total acquisition time, 3) assessment of image quality and 4) detection of stenoses >50%. Average navigator efficiencies of the LCA and RCA were 43+/-12% and 42+/-12% with and 36+/-16% and 35+/-16% without 3D MAG (P<0.01). Scan time was reduced from 12 min 7 s without to 8 min 55 s with 3D MAG for the LCA and from 12 min 19 s to 9 min 7 s with 3D MAG for the RCA (P<0.01). The average scores of image quality of the coronary MRAs with and without 3D MAG were 3.5+/-0.79 and 3.46+/-0.84 (P>0.05). There was no significant difference in the sensitivity and specificity in the detection of coronary artery stenoses between coronary MRAs with and without 3D MAG (P>0.05). 3D MAG provides accelerated acquisition of navigator gated coronary MRA by about 19% while maintaining image quality and diagnostic accuracy.

Aged↗

[3D motion adapted gating: a new navigator technique to shorten the acquisition time for coronary MRA].

PURPOSE: A major problem of free breathing coronary MR angiography (MRA) with respiratory navigator gating is low navigator efficiency and prolonged scan time due to irregular breathing patterns. 3D motion adapted gating (MAG) is a new adaptive navigator technique, which adapts in real time to changes of the end-expiratory position of diaphragm. This study evaluates the influence of 3D MAG on coronary MRA. METHODS AND MATERIALS: In 3D MAG, two additional gating windows are grouped around the conventional window. Additionally, each gating window is divided into three bands assigned to different portions of the k-space. The scan is terminated when three consecutive bands are filled and one complete image data set is collected. Free breathing navigator-gated coronary MRA was performed on 48 patients with suspected coronary artery disease. In random order, each patient underwent an ECG-gated, a 3D segmented k-space gradient echo sequence using 3D MAG and a conventional navigator technique. The coronary MRA was evaluated and compared using the following parameters: 1. navigator efficiency and scan time; 2. visualized coronary artery length; 3. qualitative assessment of image quality; and 4. detection of stenoses > 50 % in comparison with catheter angiography. RESULTS: Coronary MRA with 3D MAG had a significant increase in the average navigator efficiency (46 % +/- 12 % vs. 38 % +/- 12 %, p < 0.05), resulting in a significantly shorter scan time (mean: 18 % +/- 4 %, p < 0.05) for coronary MRA with 3D MAG compared to conventional navigator technique. Scans with and without 3D MAG had no significant differences in the continuously visualized vessel lengths, in the assessed image quality and in the sensitivity and specificity (83 % and 89 % vs. 83 % and 88 %, p > 0.05) of detecting coronary artery stenoses > 50 %. CONCLUSION: The 3D MAG technique improves the navigator efficiency and significantly (p < 0.05) shortens the scan time of navigator gated coronary MRA while maintaining image quality and diagnostic accuracy in the detection of coronary artery stenoses.

Adult↗

[Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla].

PURPOSE: In-vitro and In-vivo evaluation of feasibility and safety of MRI of the brain at 1.5 T in patients with implanted pacemakers (PM). MATERIALS AND METHODS: 24 PM models and 45 PM electrodes were tested In-vitro with respect to translational forces, heating of PM leads, behaviour of reed switch (activated vs. deactivated) and function at a 1.5 T MRI-system (actively shielded, maximum field gradient: 30 mT/m; rise time: 150 T/m/s). Based on these results, 63 MRI examinations in 45 patients with implanted PM were performed. Prior to MRI the PM were re-programmed in an asynchronous mode. The maximum SAR of MRI-sequences was limited to 1.2 W/kg. Continuous monitoring of ECG and pulse oximetry was performed during MRI. PM inquiry was performed prior to MRI, immediately after MRI and -- to assess long-term damages -- three months after the MRI exams, including determination of stimulation thresholds to assess potential thermal myocardial injuries at the lead tips. RESULTS: Translational forces (F (max) < or = 560 mN) and temperature increase (DeltaT (max) < or = 2.98 degrees C) were in a range which does not represent a safety concern from a biophysical point of view. No changes to the programmed parameters of the PM or damage of PM components were observed neither In-vitro (n = 0/24) nor In-vivo (n = 0/63). Despite the strong magnetic field, the reed switch remained deactivated in 54 % (13/24) of the cases during In-vitro simulated MRI exams of the brain. All patient studies (n = 63/63) could be completed without any complications. Atrial and ventricular stimulation thresholds (expressed as pulse duration at 2-fold rheobase) did not change significantly immediately post-MRI nor in the 3 months follow-up (pre-MRI: 0.17 ms +/- 0.13 ms, post-MRI: 0.18 ms +/- 0.14 ms, 3 months follow-up: 0.17 ms +/- 0.12 ms). CONCLUSION: MRI of the brain at 1.5 Tesla can be safely performed in carefully selected clinical circumstances when appropriate strategies are used (re-programming the PM to an asynchronous mode, continuous monitoring of ECG and pulse oximetry, limiting the SAR value of the MRI sequences, cardiological stand-by). Based on these studies, implanted PM should not longer be regarded as an absolute contraindication for MRI at 1.5 T.

Burns, Electric↗

[Long-term fate of left atrial thrombi and incidence of cerebral embolism under continuous anticoagulation therapy].

PURPOSE: Patients (pts.) with atrial fibrillation (AF) and atrial thrombi are known to have an increased risk for cerebral embolism. However, little is known about the clinical course of atrial thrombi and the incidence of cerebral embolism in those patients during anticoagulation therapy. The high sensitivity of MR imaging (MRI) including diffusion-weighted imaging (DWI) suggests that this technique could provide an improved estimate of cerebral embolism associated with the presence of left atrial thrombi. The aims of this prospective study were to evaluate 1) the prevalence of clinically silent and apparent cerebral embolism in pts. with newly diagnosed AF and atrial thrombi using MRI/DWI, 2) the long-term fate of atrial thrombi under continues anticoagulation therapy and 3) the incidence of cerebral embolism during a follow-up period of 12 months with continuous anticoagulation therapy. MATERIALS AND METHODS: The study group consisted of 32 pts. with 1) newly diagnosed AF and evidence of left atrial (LA) thrombi detected by TEE and 2) a new start of anticoagulation therapy [International Normalized Ratio (INR) 2.0 - 3.0]. 19 pts. with 1) newly diagnosed AF and no evidence of atrial thrombi and 2) an equivalent anticoagulation regimen served as the control group. In both groups a) MRI/DWI studies of the brain (weeks 0, 4, 8, 12, 20, 28, 36, 44, and 52), b) transesophageal echocardiographic studies (TEE) for assessment of LA-Thrombi (weeks 0 and 52) and c) clinical neurological assessments (weeks 0, 20 and 52) were performed. RESULTS: In the study group (AF and LA-Thrombi) 11 out of 32 pts. (34 %) displayed signs of acute (n = 8) or chronic (n = 3) cerebral embolism in the initial MRI studies. In 4 out of 32 pts. (13 %), MRI/DWI depicted new or additional cerebral emboli (n = 12) during the follow-up period despite continuous anticoagulation therapy. 2 (n = 2/4; 50 %) of these patients had clinically apparent neurological deficits. In the control group 1 out of 19 pts. (5 %) showed evidence of chronic cerebral embolism as assessed by MRI/DWI at the beginning of the study (week 0). No embolic cerebral lesions were detected during the 12-month follow-up. Within 12 months only 63 % (n = 20/32) of LA thrombi in the study group resolved completely under anticoagulation. CONCLUSION: 1. The incidence of clinically inapparent cerebral emboli in pts. with newly diagnosed AF and atrial thrombi is much higher than the incidence of clinically apparent emboli and has been underestimated in the past. 2. New cerebral embolism may occur even with continued effective anticoagulation therapy in 13 % of pts. 3. Only 63 % of atrial thrombi resolve completely within 12 months under anticoagulation therapy.

Aged↗

[High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system].

PURPOSE: To evaluate magnetic field interactions of commonly used biomedical implants at 3.0 Tesla. MATERIALS AND METHODS: Fourteen aneurysm clips designed for permanent placement in intracranial aneurysms, 19 coronary artery stents and 20 iliac artery stents were evaluated in an actively shielded compact 3.0 T MR system (Intera, Philips Medical Systems, Best, The Netherlands, length of magnet 1.57 m). The magnetic deflection forces (translational movement) were evaluated as follows: The implants were suspended by a fine string and placed in the magnet bore at the location of the maximum magnetic field gradient. The translational forces F (z) were calculated from the measured angle of deflection from the vertical axis. The magnetic field-induced torque (rotational forces) was evaluated as follows: Each implant was placed in the center of the magnetic bore parallel to the static magnetic field B0 (position 0 degrees ). Any possible displacement of the implant was noted on a millimeter scale and any torque qualitatively evaluated using a 5 point grading scale (0: no torque; + 4: very strong torque). The implant was turned in steps of 45 degrees, and the procedure was repeated to encompass a full 360 degrees rotation. RESULTS: In 52 of the 53 devices tested, the deflection force (deflection angle: range 0-21 degrees, translational force: range 0-3.8 mN) was less than the gravitational force (i.e., the implant's weight). These devices (n = 52/53) did not show any alignment to or rotation in the magnetic field at any of the various 45 degrees -increment positions corresponding to a qualitative torque evaluation of grade 0/4. One device (n = 1/53), an iliac artery stent made of stainless steel (Zenith, Cook, Mönchengladbach, BRD), was found to have deflection forces (deflection angle 88 degrees translational force 299 mN) greatly exceeding the gravitational force as well as a pronounced torque (grade 4/4). CONCLUSION: Out of 53 biomedical implants evaluated for magnetic field interactions at 3.0 T, one iliac artery stent made of stainless steel was found to be potentially unsafe based on ASTM criteria. MR imaging at 3.0 Tesla may be performed safely in patients with any of the other 52 different implants evaluated in this study with respect to magnetic field translational attraction and torque.

Alloys↗

[The value of applying nitroglycerin in 3D coronary MR angiographie with real-time navigation technique].

PURPOSE: Nitroglycerin administration results in dilation of epicardial coronary vessels and in an increase in coronary blood flow, and has been suggested to improve MR coronary angiography. This study evaluates systematically whether administration of nitroglycerin improves the visualization of coronary arteries and, as a result, the detection of coronary artery stenosis during free breathing 3D coronary MR angiography. MATERIALS AND METHODS: Coronary MR angiography was performed in 44 patients with suspected coronary artery disease at a 1.5 Tesla System (Intera, Philips Medical Systems) (a) with and (b) without continuous administration of intravenous nitroglycerin at a dose rate of 2.5 mg/h, using an ECG gated gradient echo sequence with real-time navigator correction (turbo field echo, in-plane resolution 0.70 x 0.79 mm(2), acquisition window 80 ms). Equivalent segments of the coronary arteries in the sequences with and without nitroglycerin were evaluated for visualized vessel length and diameter, qualitative assessment of visualization using a four point grading scale and detection of stenoses > 50 %. Catheter coronary angiography was used as a gold-standard. RESULTS: No significant differences were found between scans with and without nitroglycerin as to average length of the contiguously visualized vessel length (p > 0.05) and diameter (p > 0.05). There was also no significant difference in the coronary MR angiography with and without nitroglycerin in the average qualitative assessment score of the visualization of LM, proximal LAD, proximal CX, and proximal and distal RCA (2.1 +/- 0.8 and 2.2 +/- 0.7; p > 0.05). Sensitivity (77 % [17/22] vs. 82 % [18/22] p > 0.05) and specificity (72 % [13/18] vs. 72 % [13/18] p > 0.05) for the detection of coronary artery stenosis also did not differ significantly between scans with and without intravenous administration of nitroglycerin. CONCLUSION: Administration of nitroglycerin does not improve visualization of the coronary arteries and detection of coronary artery stenosis in free breathing 3D coronary MR angiography.

Coronary Angiography↗

[Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease].

PURPOSE: To evaluate the clinical value of high-resolution coronary MR angiography (coronary MRA) in a large group of patients with suspected coronary artery disease. METHODS AND MATERIAL: 107 patients with suspected coronary artery disease underwent free-breathing coronary MRA (Intera, 1.5 T, Philips Medical Systems). To compensate for artefacts due to respiratory motion, a right hemidiaphragmatic navigator with real time-time slice correction was used. An ECG-gated, fat-suppressed, 3D segmented-k-space gradient echo sequence (in plane resolution 0.70 x 0.79 mm(2)) was used. Cardiac catheterization with selective coronary angiography was performed in all patients. Visualization of the coronary arteries (CA) was qualitatively assessed using a four-point grading scale. RESULTS: Image quality of grade 1 was achieved in 24 %, grade 2 in 48 %, grade 3 in 24 % and grade in in 4 % of patients. Based on an evaluation of the coronary MRAs of all patients (n = 107) sensitivity and specificity for the detection of stenoses > 60 % in the proximal and middle main coronary arteries were 74 % and 63 %, respectively. In coronary MRAs with good quality [grade 1 and 2, n = 77/107 (72 %)] sensitivity and specificity for the detection of coronary stenoses were 88 % and 91 %, respectively. CONCLUSION: Submillimeter 3D coronary MRA with real-time navigator correction allows high quality imaging of the proximal and middle main coronary arteries with good sensitivity and specificity for detection of stenoses > 50 % in selected patients. However, in about 28 % of patients image quality is severely impaired.

Adult↗

Alterations of INK4a(p16-p14ARF)/INK4b(p15) expression and telomerase activation in meningioma progression.

Dysregulation of cell cycle progression and telomerase activation have been implicated in malignant tumor progression as well as in the evasion of senescence and immortalization. We have investigated expression of the cell cycle control and tumor suppressor genes INK4a(p16-p14ARF), INK4b(p15-p10) and RB, and their relation to telomerase activation during malignant meningioma progression. 7/26 (27%) benign, 3/12 (25%) atypical but 4/7 (57%) anaplastic tumors lacked both, p16 and p15 protein expression. 14/39 (36%) benign and atypical but 5/7 (71%) anaplastic meningiomas contained no p14ARF mRNA. 2/46 (4%) tumors failed to express pRB. We observed frequent differential loss of expression of the alternatively spliced INK4a tumor suppressors p16 and p14ARF. Exclusive expression of the alternative INK4b transcript p10 possibly at the expense of p15 and therefore resulting in loss of p15 tumor suppressor activity was noted in two meningiomas. We have previously described telomerase activity or expression of the telomerase catalytic subunit hTERT in this meningioma series. Telomerase activation was detected in 10/27 (37%) benign, but 18/19 (95%) non-benign meningiomas. We observed no significant overall correlation between loss of INK4a/INK4b expression and telomerase activation. In conclusion, our results suggest a greater role for losses of INK4a/INK4b gene products in meningioma formation and malignant progression than previously thought. Inactivation of p16/p15- and pl4ARF-dependent pathways possibly in conjunction with telomerase activation might be critical steps for a meningioma cell towards escape from senescence, that is, immortalization.

Adult↗

["Words" in orthopaedics (author's transl)].

The interpretation of the words in the detailed and prolix terminology by Andry conveys some of the essential contents of modern orthopaedics, but completely ignores another branch of orthopaedics in adults, particularly its most important source, namely, traumatology of the locomotor organs.