PubMed Health⌕ Search

Biomedical subjects

M Hanley

Publications and source records attributed to M Hanley.

22 records · Page 2Linked to original sources

Behavior of expiratory neurons in response to mechanical and chemical loading.

The response of medullary expiratory neurons to added mechanical and chemical loads was studied in anesthetized cats. Alterations in burst characteristics and central timing were compared in the intact and bilaterally vagotomized cat. The following results were obtained: (1) Graded expiratory airflow resistances caused progressive increases in burst duration, spikes per burst and firing rate; similar effects were noted for end-inspiratory tracheal occlusions and continuous positive breathing; all facilitation was eliminated by vagotomy. (2) Graded inspiratory airflow resistances delayed the onset of an expiratory burst but did not change the overall burst characteristics. (3) Acute hypercapnia increased ventilation without noticeable changes in expiratory burst characteristics; acute hypoxia produced a reduction in burst duration concomitant with changes in ventilation. It is concluded that (1) expiratory neurons are responsive to vagally mediated volume information and (2) transient hypoxia and hypercapnia sufficient to increase ventilation does not increase the firing rate of expiratory neurons but exerts differential effects with respect to timing. It is suggested that expiratory duration is related to the time integral of expired volume and that the increase in FRC imposed by expiratory loads does not alter the central timing of the next inspiration.

Action Potentials↗

Pseudomonas aeruginosa bacteremia in a dialysis unit. 11. Relationship to reuse of coils.

Blood for culture was obtained over a six week period from 17 patients undergoing long-term hemodialysis. Bacteremia was detected during 18 of 201 dialyses. Blood drawn during fifteen of these dialyses contained pseudomonas aeruginosa. Ten of the 17 patients (59 per cent) had a Pseudomonas bacteremia some time during the study. Only one patient was symptomatic. The frequency of positive cultures was related to reuse of coils. No cultures were positive until after the fifth use, but by the tenth use, 41 per cent of the dialyses were associated with bacteremia. All coils that were used repeatedly and 32 of 48 of those used only once, grew Ps. aeruginosa when filled with media and incubated. This suggests that the coils were inoculated during dialysis and that benzalkonium chloride, the sterilizing agent, was unable to eradicate this organism. With repeated uses, the number of residual bacteria in the coil became large enough to cause detectable bacteremia during dialysis.

Cross Infection↗