PubMed Health⌕ Search

Biomedical subjects

M Haverling

Publications and source records attributed to M Haverling.

At least 19 recordsLinked to original sources

Multiple-beam equalization radiography in chest radiology. Image quality and radiation dose considerations.

The large difference in transmission between the mediastinum and the part of the chest mainly containing lungs causes major problems in chest radiography. A system for advanced multiple beam equalization radiography has been evaluated. Evaluation of image quality has been performed both using standard phantoms and from clinical radiographs. Measurements of radiation dose burden to the patient have been made both in clinical examinations and using an anthropomorphic phantom. The image quality, in areas with low transmission, is substantially increased using the equalization system. In parts of the chest mainly containing lung tissue, conventional systems show an equal or slightly better image quality. The radiation dose burden to the patient is increased by 25 percent using the equalization system, as compared to a low-dose air-gap system. In our opinion, the slight increase in radiation dose burden is well motivated by the high overall quality of the radiographs produced.

Humans↗

Clinical value of serum digoxin assays in outpatients: improvement by the standardization of blood sampling.

Everyday physical activity previously has been shown to affect serum digoxin concentrations. Standardized rest in the supine position increases outpatient serum digoxin levels 0% to 75%. The present study comprising 56 outpatients treated with digoxin was undertaken to elucidate the clinical importance of a standardized period of rest before collection of the blood sample. Blood samples were taken about 24 hours after the latest dose, before and after 2 hours of rest in the supine position. A careful clinical examination, including electrocardiogram (ECG) findings, systolic time intervals, and chest x-ray studies, was performed to identify adverse effects/intoxication or failure of digitalis treatment. Signs of failure of digitalis treatment occurred in 12% of the patients, with a serum digoxin concentration of 0.68 +/- 0.15 (mean +/- SD) nmol/L before rest and 0.85 +/- 0.22 nmol/L after rest. Eleven percent showed signs of adverse effects/intoxication, with serum digoxin concentrations of 1.70 +/- 0.70 nmol/L before rest and 2.08 +/- 0.80 nmol/L after rest. The serum digoxin concentrations of the adequately treated patients (77%) were 1.02 +/- 0.35 nmol/L before rest and 1.28 +/- 0.41 nmol/L after rest. The importance of standardized rest before blood sampling is illustrated by the fact that only one third of the patients without signs of adverse effects/intoxication or failure of digitalis treatment had serum digoxin concentrations within the therapeutic range most commonly used (1.2 to 2.6 nmol/L) without supine rest. If allowed to rest in the supine position before blood sampling, approximately 60% of the adequately treated patients had serum digoxin concentrations within this range.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The mineral content of the middle ear ossicles. A radiologic and chemical study on normal and diseased ossicles.

The underlying mechanism responsible for bone resorption in chronic otitis media with or without cholesteatoma is not sufficiently well documented. Certain areas in the middle ear are affected more often than others. The most frequent site of bony erosion in the ossicular chain is the long process of the incus. The mineral content of the ossicular chain was investigated with a clinical radiologic technique (polytomography). The findings were correlated with chemical measurements of the mineral content in normal and diseased ossicles. A poor correlation between the radiologic findings and the chemical assessment was found. The mineral content of ossicles obtained from ears with chronic otitis was similar to that of specimens obtained from healthy middle ears. The findings indicate that the demineralization process seems to be localized to a narrow zone of the ossicle and that this zone cannot be adequately visualized by standard radiologic techniques.

Absorptiometry, Photon↗

Salivary calculi and chronic sialoadenitis of the submandibular gland: a radiographic and histologic study.

This study correlated radiographic observations and histologic findings of submandibular glands with the diagnosis of salivary calculus and/or chronic sialoadenitis. During a 15-year period eighty-eight patients satisfied clinical requirements by having a radiographic examination performed prior to gland extirpation. Salivary calculi were present in 83% of the patients. The diagnostic accuracy of radiographs regarding salivary calculi in the submandibular gland system was 92%. Radiolucent calculi constituted 20% of the total number of cases with concrements. Failure to disclose concrements was caused by lack of contrast filling due to a damaged gland which presumably camouflaged radiolucent concretions. Ductal changes observed in sialograms corresponded to histologic changes in the glandular parenchyma in 96% of the cases. The absence of ductal change in sialograms did not necessarily indicate a nondiseased gland.

Adolescent↗

Radiographic diagnosis of foreign bodies in the oesophagus.

In a group of patients suspected of harbouring a foreign body in the oesophagus, the diagnostic accuracy of radiographic examination is found to be high. Only 1 of 243 patients examined by radiography presented a false negative result.

Adolescent↗

Soft tissue abnormalities at fracture of the scaphoid.

In a retrospective examination of the films from 53 cases with fracture of the scaphoid it was possible to demonstrate soft tissue alterations within the scaphoid fossa. All these cases were examined adequately, i.e. with correct projections and satisfactory penetrating exposure. A somewhat higher quality of the views was obtained on industrial film.

Adolescent↗

Facial bone scintigraphy. I. Metastatic lesions in the mandible.

Five cases of metastases in the mandible are reported. Conventional radiography and bone scintigraphy by 99Tcm-DP recorded by gamma camera were performed. Invariably the lesions were clearly demonstrated by scintigraphy when radiography revealed only minor structural changes of the bone tissue.

Aged↗