Arterial blood gas reference values for sea level and an altitude of 1,400 meters.

Blood gas measurements were collected on healthy lifetime nonsmokers at sea level (n = 96) and at an altitude of 1,400 meters (n = 243) to establish reference equations. At each study site, arterial blood samples were analyzed in duplicate on two separate blood gas analyzers and CO-oximeters. Arterial blood gas variables included Pa(O(2)), Pa(CO(2)), pH, and calculated alveolar-arterial PO(2) difference (AaPO(2)). CO-oximeter variables were Hb, COHb, MetHb, and Sa(O(2)). Subjects were 18 to 81 yr of age with 166 male and 173 female. Outlier data were excluded from multiple regression analysis, and reference equations were fitted to the data in two ways: (1) best fit using linear, squared, and cross-product terms; (2) simple equations, including only the variables that explained at least 3% of the variance. Two sets of equations were created: (1) using only the sea level data and (2) using the combined data with barometric pressure as an independent variable. Comparisons with earlier studies revealed small but significant differences; the decline in Pa(O(2)) with age at each altitude was consistent with most previous studies. At sea level, the equation that included barometric pressure predicted Pa(O(2)) slightly better than the sea level specific equation. The inclusion of barometric pressure in the equations allows better prediction of blood gas reference values at sea level and at altitudes as high as 1,400 meters.

Adolescent↗

High-frequency electrostimulation hearing after mastoidectomy.

This study was undertaken to measure the degree of high-frequency sensorineural hearing loss following mastoid surgery. Twenty-five patients undergoing mastoidectomy procedures were tested preoperatively, less than 2 days postoperatively, and at 30 days postoperatively using the Tonndorf Audimax 500 high-frequency audiometer. Electrostimulation thresholds in 1-kHz intervals, from 1 to 20 kHz, were measured, and the highest detectable frequency was determined to within 0.1 kHz. Surgical drilling time was recorded. Average drilling time was 51 minutes. A significant temporary threshold shift was observed, measurable at multiple frequencies, less than 48 hours after mastoidectomy. There was no clinically significant change in electrostimulation thresholds (measured in 1-kHz increments, from 1 to 16 kHz) preoperatively to 30 days postoperatively. A statistically significant average loss of 0.89 kHz in the highest frequency producing a measurable response was noted (p less than 0.05). Determinations of the highest measurable frequency may be the most sensitive measure of surgically-induced, high-frequency sensorineural hearing changes.

Adolescent↗