PubMed Health⌕ Search

Biomedical subjects

M Helsen

Publications and source records attributed to M Helsen.

4 recordsLinked to original sources

Recovery of impaired muscle function in severe sciatica.

This is a prospective cohort study of patients with acute treated severe sciatica. The objectives of the study are, firstly, to describe the recovery of muscle performance by manual and isokinetic muscle testing in patients with acute severe sciatica over 1 year, and secondly, to discuss the potential clinical relevance of the isokinetic testing of the ankle for patients with acute sciatica. In clinical daily practice, muscle performance is evaluated by means of isometric manual tests. Different authors using manual muscle tests have reported the long-term outcome of the muscle function in patients with sciatica. Overall, the results are good in terms of the recovery of muscle strength. However, it is not clear whether the isometric strength is sufficiently relevant to evaluate the more complete muscle performance of the affected muscles in patients with sciatica. This study presents data on the muscle recovery measured with manual testing and isokinetic testing of patients with severe sciatica. Consecutive patients admitted to the Cantonal Hospital for conservative management of severe acute sciatica were eligible for inclusion in the study. Patients were evaluated at admission, discharge, and follow-up at 3, 6, and 12 months. All the visits included a standardized clinical examination and the completion of questionnaires. Imaging and electromyography were conducted at the first visit. Isokinetic muscle tests at 30 degrees/s and 120 degrees/s were performed at discharge and follow-up visits. Manual and isokinetic tests were performed on foot and ankle flexor and extensor muscles. Eighty-two consecutive patients (66% men), with a mean age of 43 (+/-10.3) years, entered the study. The prevalence of major muscle weakness was low, with 7% of patients unable to perform toe walking and 11% unable to walk on the heel at visit one. Moreover, motor deficit defined as a score of 4 or less (out of 5) was found in 15% of subjects at the first evaluation. Such severe deficits were not found during the last three visits. The isokinetic tests showed a higher prevalence of muscle function impairment. At visit 5, the isokinetic test showed impaired muscle function recovery from 23% to 32%, while the manual test showed almost full recovery. The issues of agreement between manual and isokinetic muscle testing are discussed. In this selected and homogeneous cohort of patients, the prevalence of motor deficit was rather low and the outcome excellent according to the results of the manual testing. Isokinetic muscle tests showed a higher prevalence of deficit and a much slower recovery. The manual muscle test is a crude clinical test. For more indepth muscle performance evaluation, additional testing may be necessary, especially for those patients with physically demanding jobs or activities.

Adult↗

Efficient method for (lyso)phospholipid class separation by high-performance liquid chromatography using an evaporative light-scattering detector.

A simple high-performance liquid chromatography method with evaporative light-scattering detection has been devised in order to separate and quantify the major phospholipid and lysophospholipid classes. HPLC analyses were performed with a diol-silica column and ternary gradient elution. Standard curves were drawn up for each of the (lyso)phospholipids involved.

Chromatography, High Pressure Liquid↗

Amelioration of established murine collagen-induced arthritis with anti-IL-1 treatment.

Inflammatory cytokines have been implicated in the pathogenesis of rheumatoid arthritis. To validate a key role for IL-1 in arthritic processes we have studied the protective effect of neutralizing antimurine IL-1 antibodies in the murine collagen-induced arthritis (CIA) model. Combination of anti-IL-1 alpha and anti-IL-1 beta given before onset of arthritis was shown to prevent disease completely. Remarkably, a single treatment was also highly effective in the established phase of arthritis, reducing both inflammation as well as cartilage destruction. Suppression was most pronounced with the combination, but anti-IL-1 beta alone also induced significant relief. Finally, we studied the protective effect of IL-1 neutralization on cartilage metabolism in a unilateral expression model of collagen arthritis. To this end zymosan was injected in one knee joint before onset of disease, resulting in accelerated expression in that particular joint and the draining paw. Anti-IL-1 treatment started after accelerated expression of arthritis was able to fully normalize chondrocyte synthetic function, which was highly suppressed in the control group. It is concluded that IL-1 is an important determinant in both inflammation and cartilage destruction in collagen arthritis, and this may have implications for therapy in human arthritis.

Animals↗

Element concentrations in the air of an indoor shooting range.

Elemental emissions during firing in a shooting range were measured for different types of ammunition. When using Hirtenberger bullets, lead, barium, antimony and to a lesser extent copper and arsenic were the primary metal pollutants. Stationary sampling at three locations in the range did not reveal large concentration gradients. Large concentration variations were observed by sampling before, during and after shooting. Lead and antimony concentrations peak at 5060 and 119 micrograms m-3, respectively. Soil elements such as aluminium, sodium and calcium are enriched during shooting, probably due to soil resuspension by the shooters and the bullets hitting the sand backstop. After shooting has ceased the concentrations fall to within pre-shooting levels within a couple of hours. Measurement of the aerodynamic particle size shows low mass median diameters for the elements emitted during firing and larger diameters for the soil-associated elements. The peak airborne concentrations measured by stationary sampling, and human exposure measured by a personal sampler carried by an instructor were compared with threshold limit values. During the shooting the TLV is significantly exceeded for lead.

Air↗