Dual X-ray absorptiometry of the proximal femur: normal European values standardized with the European Spine Phantom.

Measurements of the proximal femur by dual X-ray absorptiometry (DXA) are assuming increasing importance in clinical and epidemiological studies. However, different DXA manufacturers have adopted varying approaches to measuring the femoral neck and trochanter regions with the result that there is as yet no agreement on normal ranges and how to cross-calibrate between different machines. In this Concerted Action (of the EU's 2nd Framework Programme), 12 clinical centers in eight countries recruited a total of 855 female and 517 male Caucasian subjects who were judged to be free of conditions known to cause secondary osteoporosis and who had not been treated with drugs known to affect bone mass. The DXA machines used were made by Hologic, Lunar, and Norland. Each machine was cross-calibrated with the European Spine Phantom prototype designed by Kalender. All femoral neck and trochanter results were expressed as standardized values and were first examined for possible bias due to between-brand differences in choice of areas for measurement. On average, trochanter areas were similar between brands but Norland chose a narrower neck region for analysis. Bone mineral density (BMA or BMD g/cm2) was log-normally distributed for all groups at the femoral neck but normally distributed at the trochanter in men and postmenopausal women. There were substantial between-center differences after cross-calibration in age-adjusted mean values at both sites and also in the rates of apparent bone loss with age and the amounts of scatter within populations about mean age-adjusted values. With the proviso that locally derived normal ranges would allow more accurate comparisons for clinical purposes, European normal ranges were derived for both neck and trochanter. Data obtained with the three individual brands of machine fitted these overall ranges well. Bone loss was apparent in premenopausal women at the femoral neck but not the trochanter. Postmenopausal women's data was somewhat better fitted by reference to years since menopause than to chronological age. This work provides a basis for conducting future epidemiological and clinical studies with more than one brand of machine as long as each individual subject, if measured consecutively, is measured on the same machine throughout.

Absorptiometry, Photon

European semi-anthropomorphic spine phantom for the calibration of bone densitometers: assessment of precision, stability and accuracy. The European Quantitation of Osteoporosis Study Group.

Up to now it has not been possible to reliably cross-calibrate dual-energy X-ray absorptiometry (DXA) densitometry equipment made by different manufacturers so that a measurement made on an individual subject can be expressed in the units used with a different type of machine. Manufacturers have adopted various procedures for edge detection and calibration, producing various normal ranges which are specific to each individual manufacturer's brand of machine. In this study we have used the recently described European Spine Phantom (ESP, prototype version), which contains three semi-anthropomorphic "vertebrae" of different densities made of stimulated cortical and trabecular bone, to calibrate a range of DXA densitometers and quantitative computed tomography (QCT) equipment used in the measurement of trabecular bone density of the lumbar vertebrae. Three brands of QCT equipment and three brands of DXA equipment were assessed. Repeat measurements were made to assess machine stability. With the large majority of machines which proved stable, mean values were obtained for the measured low, medium and high density vertebrae respectively. In the case of the QCT equipment these means were for the trabecular bone density, and in the case of the DXA equipment for vertebral body bone density in the posteroanterior projection. All DXA machines overestimated the projected area of the vertebral bodies by incorporating variable amounts of transverse process. In general, the QCT equipment gave measured values which were close to the specified values for trabecular density, but there were substantial differences from the specified values in the results provided by the three DXA brands. For the QCT and Norland DXA machines (posteroanterior view), the relationships between specified densities and observed densities were found to be linear, whereas for the other DXA equipment (posteroanterior view), slightly curvilinear, exponential fits were found to be necessary to fit the plots of observed versus specified densities. From these plots, individual calibration equations were derived for each machine studied. For optimal cross-calibration, it was found to be necessary to use an individual calibration equation for each machine. This study has shown that it is possible to cross-calibrate DXA as well as QCT equipment for the measurement of axial bone density. This will be of considerable benefit for large-scale epidemiological studies as well as for multi-site clinical studies depending on bone densitometry.

Absorptiometry, Photon

The effects of differing concentrations of bupivacaine on the epidural somatosensory evoked potential after posterior tibial nerve stimulation.

The somatosensory evoked potential (SEP) recorded from the cervical epidural space in response to stimulation of the posterior tibial nerve is often used to monitor spinal cord integrity during scoliosis surgery. Epidural analgesia may be used as part of the anesthetic technique for scoliosis surgery, but the effects of the local analgesic on the evoked potential must be determined to ensure that it does not interfere with the monitoring of spinal cord function. Therefore, we compared the effects of the administration of 10 mL of 0.25% (n = 8), 0.5% (n = 8), or 0.75% (n = 8) bupivacaine injected into the L3-4 epidural space on the somatosensory evoked potential to posterior tibial nerve stimulation in patients anesthetized with a propofol infusion, nitrous oxide and oxygen, immediately before scoliosis surgery. Compared with a control group (n = 8), a concentration-dependent effect of bupivacaine was found on overall amplitude of the evoked potentials and the amplitude of all peaks. There were no significant differences between 0.25% bupivacaine and the control group, but both 0.5% and 0.75% bupivacaine were associated with clinically and statistically significant decreases in overall amplitude (P < 0.002, 0.5% bupivacaine; P < 0.001, 0.75% bupivacaine). Latency increased similarly in all groups. We conclude that bupivacaine in concentrations greater than 0.25% is not suitable for scoliosis surgery, if spinal somatosensory evoked potentials (SSEP) are to be measured.

Adolescent

Cleft palate re-repair--a clinical and radiographic study of 32 consecutive cases.

The results of clinical and radiographic assessment of palate re-repair (by a single operator) in 32 patients are presented. This has shown that radical muscle correction as a secondary procedure (following limited or no muscle correction in primary repair) has produced measurable improvement in velar function and should be considered as the first option in many patients with velopharyngeal incompetence. The results also support the concept of muscle dissection and retropositioning in primary cleft palate repair.

Adolescent

European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability.

A semi-anthropomorphic 'distal radius like' phantom, developed by Kalender and Ruegsegger for use in peripheral bone densitometry using single photon (DPA) dual X-ray (DXA) and quantitative computed tomography (QCT) machines, has been studied with a view to cross-calibrating different types and brands of densitometers in current use. In the context of an EU 'Concerted Action' (second Framework Programme) the phantom was repeatedly measured on six SPA machines, three DXA machines and nine QCT machines (545 measurements). Linear regression equations were derived, individual to each machine, which allowed the derivation of 'standardized densities'. In this way we converted measurements made by machines of the same modality to a common scale of measurements. Two machines (one DXA, one SPA) showed statistically significant instability over time emphasising the need for rigorous quality control in the application of densitometry. In other respects these results provide an encouraging basis for the derivation of standardized normative ranges and the more effective use of peripheral densitometry in future clinical and epidemiological studies.

Absorptiometry, Photon

Comparison of radionuclide ventriculography and 2D echocardiography for the measurement of left ventricular ejection fraction following acute myocardial infarction.

To compare the measurement of left ventricular ejection fraction obtained by two-dimensional echocardiography and by radionuclide ventriculography in patients following acute myocardial infarction, 49 consecutive patients with acute myocardial infarction underwent echocardiography and radionuclide ventriculography on the same day, pre-discharge. Left ventricular ejection fraction was assessed by two blinded observers for each method and reproducibility was also assessed for each technique. The limits of agreement for the differences in ejection fraction (%) between the two methods was--11.4, 12.2; the mean difference 0.4 was not significantly different from zero. The limits of agreement for the intra- and inter-observer differences in ejection fraction by radionuclide ventriculography were--9.4, 7.6 and -8.6, 11.0, respectively; the mean differences--0.9 and 1.2 were not significantly different from zero. The limits of agreement for the intra- and inter-observer differences by echocardiography were--5.8, 6.6 and--8.9, 9.5 respectively; the mean differences 0.4 and 0.3 were not significantly different from zero. Thus, two-dimensional echocardiography compares well with radionuclide ventriculography for the assessment of ejection fraction without the disadvantage of radiation.

Adult

The orally active NMDA receptor antagonist CGP 39551 ameliorates the high pressure neurological syndrome in Papio anubis.

The neurophysiological effects of a novel, orally active, competitive N-methyl-D-aspartate (NMDA) receptor antagonist (DL-(E)-2-amino-4-methyl-5-phosphono-3-pentenoic acid ethyl ester), CGP 39551, on the high pressure neurological syndrome (HPNS) were investigated in the non-human primate Papio anubis. Six animals were exposed to maximum pressures of 81 ATA in a helium and oxygen environment, on two occasions. One exposure was pretreated orally with CGP 39551 100 mg/kg 24 h before compression, the other pretreated with an equivalent volume of vehicle, in this case water. CGP 39551 significantly ameliorated the signs of HPNS, compared with controls, at pressures above 31 ATA and prevented the severe signs from occurring at the higher pressures. Onset pressures of the mild signs at low pressures were, however, unaffected. Among EEG changes, the pressure induced reduction in delta wave amplitude was prevented by CGP 39551, but the increase in the amplitude of the 7-9 Hz band was not. It is concluded that CGP 39551 may play an important role in the prophylactic treatment of HPNS.

2-Amino-5-phosphonovalerate

Psychosocial factors related to perceived compliance with cystic fibrosis treatment.

The present research was designed to investigate the adjustment of patients with cystic fibrosis (CF) and their families as well as the relationship between adjustment and physician perceptions of compliance with CF treatment. Patient and family adjustment was assessed by means of the Personality Inventory for Children as well as measures of marital adjustment, depression, and social isolation completed by mothers of CF patients. Results indicated no characteristic pattern of psychopathology or adjustment problems. However, higher levels of perceived compliance with CF treatment were found to be associated with less satisfactory marital relationships and with less frequent maternal social contacts. These findings are discussed in terms of achieving a balance between compliance and psychological adjustment.

Adaptation, Psychological

Objective evidence for tolerance, against a background of improvement, during maintenance therapy with controlled release levodopa/carbidopa.

We have investigated whether the potential benefits of a controlled release formulation of levodopa (200 mg)/carbidopa (50 mg), Sinemet CR, are realised during maintenance therapy. Eight sufferers from idiopathic Parkinsonism, mean age 69.9 y, were studied: all exhibited "end of dose" effect within 4 h of a dose of their maintenance therapy with levodopa (100 mg)/carbidopa (25 mg) in a conventional release formulation, Sinemet Plus. They received, in random order, initial single dose challenges with one tablet of Sinemet Plus, one and two tablets of Sinemet CR and placebo alone, each on a separate day. After a mean of 21 weeks on maintenance therapy with Sinemet CR, subsequent single dose challenges with Sinemet CR and placebo were made. Objective measures of performance and blood sampling for assay of plasma concentrations of levodopa and the major peripheral metabolite, 3-0-methyldopa (30MD) were carried out immediately before (10.00 h) and serially until 6 h after each challenge. The overall mean stride length was significantly greater in relation to the subsequent (679 mm) than the initial (517 mm) placebo challenge. Moreover, stride length immediately before the challenges was significantly greater on the subsequent occasions. Improved performance, also seen for free walking speed, was not explained by plasma levodopa or 30MD concentrations. In the initial challenges, the mean increment in stride length achieved by active treatment, as compared with placebo, did not differ significantly between the one (210 mm) and two (235 mm) tablet doses of Sinemet CR: a maximal response had been obtained.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Somatosensory and auditory evoked responses recorded simultaneously: differential effects of nitrous oxide and isoflurane.

Auditory (AER) and somatosensory evoked responses (SSER) were recorded simultaneously in eight patients under anaesthesia before surgery. We studied the effects of equi-MAC end-expiratory concentrations of isoflurane (0.65-0.75%) and nitrous oxide (60-65%). The anaesthetics were changed at random in three consecutive 10-min periods so that each patient received both drugs. From the AER recorded from the vertex and inion, Pa and Nb latency and amplitude were measured. N13, P20 latency and N13 amplitude were measured from SSER recordings from the neck and P15, N20, P25, N35, P45 latency and P15-N20, N20-P25, P25-N35 and N35-P45 amplitude from the scalp over the hand area of the sensory cortex. Compared with nitrous oxide, isoflurane significantly increased the latencies of the AER waves Pa (P = 0.02) and Nb (P = 0.02), and the SSER waves N20 (P = 0.001) and P25 (P = 0.04). We were unable to demonstrate significant differences in Pa and Nb amplitude between isoflurane and nitrous oxide that we had seen previously. However, the amplitude of the SSER wave N20 was reduced significantly by nitrous oxide compared with isoflurane (P = 0.0004). This wave (N20) is thought to emanate from the thalamo-cortical radiations, and our findings may be explained by an analgesic effect of nitrous oxide mediated by endogenous opioids.

Adult