[CT-colonography: current status and future directions in consideration of the technical evolution].

Computertomography and with it CT-colonography evolves technically and also possibilities of data processing proceed rapidly. The current status of CTC can be summarized as follows:The method represents a true alternative to barium enema if technical conditions are given.CTC can be performed with excellent results immediately following an incomplete colonoscopy. In pretherapeutic diagnosis of colorectal carcinoma, CTC can be combined with a staging CT of the abdomen. The recent technical advances with new 16 row technology in image quality and data acquisition - mainly concerning the spatial and temporal resolution - are very promising. Developments in postprocessing of CT data can also contribute to a higher efficiency of labor. Alternative preparation schemata can lead to a more comfortable bowel cleansing and stool labeling can even avoid this procedure, resulting both in an even improved compliance. Radiation exposure in low dose technique is comparable to a double contrast barium enema and can be still reduced by optimisation of scanning parameters.The aim of the following article is (1 to give an overview of the current status of patient preparation, image acquisition and data processing; (2) to review recent clinical trials and experimental studies and to show future directions of CTC with regard to the clinical development.

Colonic Polyps↗

Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.

AIMS: A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS: A total of 102 patients underwent both conventional and MDCT coronary angiography. After intravenous injection of a non-ionic contrast medium the entire heart was scanned within a single breath hold using 1mm slices. All MDCT data sets were reconstructed with retrospective gating at 20% to 80% in increments of 10% relative to the cardiac cycle. Two blinded independent reviewers analysed image quality for segments 1-4 (right coronary artery), 5-8 (left main, left anterior descending), and 11, 12 (left circumflex). These segments were evaluated for the presence or absence of significant (>or=50%) stenoses. The results were compared with those of invasive coronary angiography in a blinded fashion. Overall sensitivity for the detection of significant stenoses (>or=50%) were 0.86 (reader 1) and 0.93 (reader 2), specificity 0.96 (reader 1) and 0.97 (reader 2), negative predictive value 0.98 (reader 1) and 0.99 (reader 2). CONCLUSIONS: High resolution MDCT angiography with retrospective gating permits the non-invasive detection of coronary artery stenoses with high accuracy if image quality is optimized for each of the three major coronary arteries.

Coronary Angiography↗

[Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences].

PURPOSE: First evaluation of image quality of a new 16-slice multidetector-row computed tomography (MDCT) for the assessment of coronary artery disease and lesion detection of the coronary arteries. MATERIALS AND METHODS: On a newly developed 16-slice CT scanner (SOMATOM Sensation 16, Siemens, Forchheim, Germany) a calcium score as well as a contrast-enhanced CT angiography (CTA) were performed on 4 patients with retrospective ECG-gating and a gantry rotation time of 420 ms to exclude or follow-up coronary heart disease. CTA was performed after injecting 120 ml contrast media intravenously. After medication with a ss-Blocker, the heart rate was between 55 and 67 bpm. RESULTS: The scan time for calcium score was 12 s, for CTA 18 s (scan range 15 and 12 cm, respectively). Volume score was between 0 and 256.4. In the CT angiography the entire coronary tree could be visualized in all patients up to the very distal subsegmental branches. In two patients a complete occlusion of the RCA and the LAD were depicted, respectively. In one of these patients, a large aneurysm of the left anterior ventricular wall was also delineated. CONCLUSION: Considering our first experiences with the new 16-slice technology, an excellent visualization of the entire coronary tree including the very distal and side branches due to substantially increased spatial resolution seems to be achievable. In these patients the acquired image quality raises the hope for improved, non-invasive cardiac diagnostics. In larger studies, the clinical impact of this new technology needs to be further investigated.

Aged↗

[CT-angiography of the carotid artery: First results with a novel 16-slice-spiral-CT scanner].

PURPOSE: To evaluate a novel multislice CT system (16-slice-spiral-CT scanner) for the diagnosis of carotid artery stenosis. MATERIAL AND METHODS: Five patients with symptomatic atherosclerotic disease of the carotid arteries were examined with a 16- slice-spiral-CT scanner. Collimation was 16 x 0.75 mm, table speed 36 mm/s (pitch of 1.5), rotation time 0.5 s, tube current was 160 eff.mAs at 120 kV. 60 ml of contrast material were injected with a power injector followed by a saline flush. The start delay was measured with test bolus method (20 ml CM). Interactive multiplanar reformation (iMPR) and thin slab MIP as well as volume rendering were used for image evaluation and presentation. RESULTS: Scan time was 9 s for a range of 300 mm. This allowed imaging the whole length of the carotid artery (aortic arch to circle of Willis) in a true arterial phase. Pulsation artefacts did not impair the evaluation of the vessels at the level of the aortic arch. Overall image quality of both "source images" and 3D-reconstructions was excellent, due to a reduced voxel size of 0.03 mm (3). Image evaluation and postprocessing (iMPR, MIP) was done within 15 min. iMPR was highly accurate for demonstrating plaque morphology and determining the percentage of the stenosis. CONCLUSION: For the first time, true arterial phase images of the entire carotid artery with high spatial resolution could be acquired using a 16-slice-spiral-CT scanner. This method offers the potential to replace catheter angiography in the evaluation of carotid artery stenosis.

Blood Flow Velocity↗

[Characterization of motion artifacts in multi-slice spiral CT].

PURPOSE: Motion artifacts in multi-slice spiral CT (MSCT) resulting from object motion in and against the table feed direction (z-direction) are examined using a spherical phantom. For image interpretation of complex anatomic structures, qualitative reference points are, also applicable to selected, which are ECG-gated cardiac imaging. In this case the motion of the coronary vessels in phase with the cardiac contraction must be considered. METHODS: Measurements are obtained with a multi-slice spiral CT with a rotation time of 500 ms for 4 x 1.0 mm and 2 x 0.5 mm collimation. The phantom consists of an acrylic glass body with imbedded glass beads of 1, 2, and 3 mm diameter. The object motion is sinusoidal with an amplitude of 5 mm and frequencies of 60/min and 90/min. Compensation of the table feed by object motion is examined as a special case. RESULTS: Small parameter changes can induce a strikingly different image quality, and the moving objects emerge in different slices. Depending on the phase of the movement with respect to the CT scan, objects up to a size of 3 mm can vanish completely or appear hyperintense in the image. The model investigated is also applicable to ECG-gated cardiac imaging for the detection of stenosis. It can explain variations in the reproducibility and absolute score values of the calcium scoring. CONCLUSION: The presented considerations and results must be taken into account in image interpretation with possible object motion in the z-direction. Variations in the determination of the degree of stenosis or in calcium score measurements can be explained by different vessel motion during the diastolic heart phase.

Artifacts↗

Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound.

The reliable non-invasive detection of coronary artery disease (CAD) is a prime goal for future developments in clinical cardiology. In addition to the documentation of high-grade stenoses, the detection of vulnerable plaques is of major importance for risk stratification and early treatment to prevent plaque rupture. Recently, a new generation of fast spiral CT has been introduced using a multi-slice technique (MSCT), which is the first real quantum leap in CT since the introduction of spiral CT in the early 1990s. We report on non-invasive differentiation of coronary plaque morphology by MSCT in patients with lesions in the proximal left anterior descending artery (LAD). The results were compared with the findings of intracoronary ultrasound (ICUS). The ICUS and MSCT scans were analysed in 6 patients scheduled for ICUS-guided PTCA. One target lesion was selected in each patient. On ICUS, two lesions were classified as soft, two as intermediate and two as calcified according to established criteria based on echogenicity. By multislice CT, density measurements (expressed in Hounsfield Units, HU) were performed at 16 randomly selected areas within the plaques. The two soft plaques showed a mean density of 6+/-28 and -5+/-25 HU, the two intermediate plaques of 83+/-17 and 51+/-19 HU, and the two calcified plaques of 489+/-372 and 423+/-111 HU. To our knowledge, this is the first report on non-invasive characterisation of coronary lesions by MSCT. Plaque composition could be clearly differentiated and classified according to the ICUS results by determining tissue density within the lesions. Thus, this new technology holds promise for non-invasive risk assessment in patients with known or suspected CAD since also rupture-prone soft coronary lesions can be detected by use of this new technique.

Aged↗

[Use of VR (virtual reality) software for preoperative implantation fitting with an implantable hearing aid as an example].

PURPOSE: To prove the feasibility of a preoperative fitting test for an implantable hearing aid using a VR environment. METHODS: A high-resolution spiral CT was performed after mastoidectomy in 10 temporal bone specimens. The bony structures were segmented and merged with the Computer-Aided Design (CAD) data of the hearing aid in a VR environment. For each specimen a three-dimensional fitting test was carried out by three examiners determining the implantability of the hearing aid. The implantation simulation was compared with the real implantation procedure performed by an experienced ENT surgeon. RESULTS: The used VR system enabled real-time 3D-visualisation and manipulation of CT- and CAD-data. All objects could be independently moved in all three dimensions. The VR fitting test corresponded closely with the real implantation. The implantability of the hearing aid was properly predicted by all three examiners. CONCLUSION: Merging CT and CAD data in a virtual reality environment bears high potential for the pre-surgical determination of the fit and mountability of medical implants in complex anatomical regions.

Cochlear Implantation↗

[Analysis of artefacts by virtual endoscopy visualization of spiral CT data].

PURPOSE: Analysis of patterns and causes of artifacts found in endographic visualization of spiral CT data. MATERIALS AND METHODS: A straight perspex tube with a diameter of 20 mm was scanned in three different positions with ten scan protocols of varying table feed, increment, kernel, and signal to noise ratio (Tomoscan AVE, Philips). The resulting 30 CT datasets were visualized as a virtual endoscopy (VE) with ten different visualization protocols (Easy Vision 4.2, Philips) of varying threshold, resolution, and perspective angle. 300 VE datasets were analyzed by two radiologists and compared with the visualization of a software-generated tube in order to differentiate scanning and software artifacts. RESULTS: Five different classes of artifacts have been identified. Two of them result from the scanning process and two from the specific visualization method. Spiral patterns and the unevenness of the tube wall vary with the scanning parameter. Moiré-like patterns are caused by the VE software and depend on the visualization matrix. A high perspective angle distorts the size and form of the tube and makes it difficult for the observer to locate his position within the tube. The appearance of pseudoforamina depends on both the scanning and the visualization parameters. CONCLUSION: The knowledge of the patterns and potential causes of artifacts in endographic visualization of spiral CT scans are the basis for interpretation and optimization of this visualization method.

Artifacts↗

[Multidetector CT Angiography - is it a valuable screening tool to detect significant renal artery stenosis?].

PURPOSE: To evaluate the diagnostic value of multidetector CT angiography (MDCTA) of the renal arteries. METHODS: 27 patients underwent MDCTA of the renal arteries. Scan parameters were: collimation 4 x 1 mm, pitch 1.5, effective slice thickness 1.25 mm, reconstruction increment 0.8 mm, circulation time measurement, power injection of 80 ml iomeprol 400, flow 4 ml/sec. Independent reading on laser film was done by two radiologists using edited maximum intensity projections, multiplanar reconstructions and source images. Standard of reference was a 3D-FLASH MR angiography (1.5 T, 3.9/1.2, 10 degrees 0.2 mmol GdDTPA/kg bw) in 10 and intraarterial angiography in 17 patients. RESULTS: Analysing 63 arteries, sensitivity, specificity, positive predictive value and negative predictive value in terms of detection of moderate and high grade renal artery stenosis (n = 10) were 90, 98, 90 and 98 % for reader A, and 90 % each for reader B, respectively (kappa = 0.91 interobserver agreement). 1/11 accessory renal arteries was missed by both angiography and MDCTA. Image quality was graded as excellent or good in 26/27 of cases by both readers. CONCLUSION: MDCTA proved to be a highly accurate tool in the detection of therapeutically relevant renal artery stenosis.

Aged↗

Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.

PURPOSE: To investigate how the technique of retrospective gating can be used to optimize reconstruction of multi-detector row computed tomographic (CT) images for each of the three major coronary arteries during the cardiac cycle. MATERIALS AND METHODS: Multi-detector row coronary CT angiograms obtained in 50 patients were reconstructed at 20%-80% of the cardiac cycle in increments of 10%. Two blinded independent reviewers assessed the image quality, in terms of artifacts and visibility, obtained with three-dimensional postprocessing for segments 1-3 (right coronary artery), segments 5-8 (left main and left anterior descending coronary arteries), and segments 11 and 12 (left circumflex artery). The following grades were assigned: 1, very poor; 2, poor; 3, fair; 4, good; and 5, excellent. RESULTS: The left anterior descending artery was best visualized in middiastole at 60%-70% of the cardiac cycle, and the left circumflex artery was best visualized at 50%. The optimal reconstruction window for the right coronary artery was significantly different at 40% (P < .05). Although there was good agreement (kappa = 0.75) between the two reviewers, there was a high degree of variation in the patient population. CONCLUSION: The image reconstruction window for CT angiography of the coronary arteries should be adapted to each coronary artery. The use of one fixed time point in the cardiac cycle for image reconstruction does not provide optimal image quality.

Aged↗

[Multislice spiral CT of the paranasal sinuses: first experiences using various parameters of radiation dosage].

PURPOSE: To evaluate the potential of multislice CT in the diagnosis of the paranasal sinuses. METHODS: Dose measurements were performed exposing an Alderson Rando phantom in a four-slice spiral CT (MS-CT) while applying a variety of scan parameters. Additionally, 30 consecutive patients underwent a transversal examination by the MS-CT using 1/1/3.5/0.5 mm spiral parameters and an additional transversal or coronal scan on a conventional single slice spiral CT (SS-CT) with 2/3/1 mm. Coronal reformations of the MS-CT were compared with the primary coronal SS-CT, or coronal reformations of the transversal SS-CT, respectively, with regard to image quality and depiction of relevant anatomical details of the region. RESULTS: Superficial exposure values at the level of the eye lenses as well as for the thyroid gland were superior for MS-CT (3.62 mGy, and 0.12 mGy, resp.) as compared to SS-CT (2.96 mGy, and 0.07 mGy). Image quality was equal or superior for MS-CT as compared to SS-CT in all but one case. Drawbacks of SS-CT, such as dental amalgam artifacts, stair step artifacts or partial volume artifacts did not notably affect the coronal reformations of MS-CT. CONCLUSION: MS-CT seems to have the potential to replace primary coronal CT of the paranasal sinuses without any loss of image quality, but may even improve the overall diagnostic value. Radiation doses may still have to be reduced.

Humans↗

Functional regions of the human cytomegalovirus protein pUL97 involved in nuclear localization and phosphorylation of ganciclovir and pUL97 itself.

In order to identify functional regions of the human cytomegalovirus protein pUL97 (i) different 5' fragments of the UL97 open reading frame (ORF) were fused to the coding region of the green fluorescent protein and (ii) recombinant vaccinia viruses (rVV) were generated carrying two full-length and 11 mutated UL97 ORFs. The results indicated the presence of an N-terminal region within pUL97 which changed the intracellular distribution of the fusion proteins. pUL97 was localized in the nucleus, but not in the nucleoli, and was detected in the nuclear matrix fraction. Expression of all pUL97 mutants could be confirmed by Western blot analysis. pUL97-associated ganciclovir (GCV) phosphorylation in rVV-infected cells, determined quantitatively by HPLC analysis, was abolished completely using individual UL97 deletion mutants. Phosphorylation of full-length and some of the mutated pUL97 was detected in cells infected with the rVVs. The UL97 constructs carrying point mutations from GCV-resistant HCMV isolates at positions 460M, 520H, 594V, and the 4 aa deletion 590AACR593, also resulted in decreased but not abolished phosphorylation of GCV in the rVV system, whereas the phosphorylation of pUL97 itself was not influenced. The rVV system is a suitable method for quantitatively testing the functional relevance of pUL97 mutations.

Amino Acid Sequence↗

The UL97 gene product of human cytomegalovirus is an early-late protein with a nuclear localization but is not a nucleoside kinase.

The temporal expression of the UL97 gene product during human cytomegalovirus (HCMV) infection of human foreskin fibroblasts (HFF) and subcellular localization of this protein were analyzed by using a polyclonal antiserum raised against a truncated UL97 protein of 47 kDa. The UL97 protein was detectable 16 h after infection by Western blot (immunoblot) analysis. Since only reduced UL97 expression occurred in the presence of two inhibitors of DNA replication, phosphonoacetic acid and ganciclovir, we conclude that UL97 is an early-late gene, requiring DNA replication for maximum expression. By indirect immunofluorescence, the protein could be visualized in the nuclei of virus-infected HFF 22 h after infection. Nuclear localization of the UL97 protein was also detected in thymidine kinase-deficient 143B cells infected with a recombinant vaccinia virus containing the entire UL97 open reading frame (ORF), as well as in HFF transiently expressing the entire UL97 ORF under the control of HCMV major immediate-early promoter. However, transiently expressed 5'-terminal deletion mutants of the UL97 ORF in addition showed a cytoplasmic localization of the UL97 protein, confirming the presence of a nuclear localization site in the N-terminal region of the protein. Our high-pressure liquid chromatography analyses confirmed the ganciclovir phosphorylation by the UL97 protein, but no specific phosphorylation of natural nucleosides was observed, indicating that the UL97 protein is not a nucleoside kinase. During plaque purification of recombinant UL97-deficient HCMV, this virus was growth defective; hence, we presume that UL97 may be essential for the viral life cycle.

Amino Acid Sequence↗

Computer-aided surgical planning for implantation of hearing aids based on CT data in a VR environment.

A study was undertaken to assess the feasibility of a preoperative fitting test for an implantable hearing aid in a virtual reality (VR) environment. High-resolution spiral computed tomography (CT) of the mastoid bone was performed, and the results of a mastoidectomy were simulated with manual segmentation on a standard medical workstation. CT was also performed on a temporal bone specimen obtained at real mastoidectomy, and the bone margins were segmented automatically with threshold-based techniques. A triangulated surface representation of the bone structures including the mastoid cavity was generated. These data as well as the computer-aided design (CAD) files of the medical devices were transferred into a VR environment. The CAD components of the hearing aid were manipulated to simulate the surgical implantation procedure. Merging CAD data of an implantable hearing aid with CT data of the temporal bone in a VR environment was shown to be a feasible method of providing three-dimensional information for the presurgical determination of fit and mountability. Advances in hardware and software are expected to improve the usability of this method. Although clinical studies are needed, these results may serve as an impetus for exploring the use of low-cost, widely available VR computer equipment in a potentially broad field of clinical applications.

Cochlear Implants↗