[Echocardiographic diagnosis of the aorto-pulmonary window].

UNLABELLED: PURPOSE/MATERIALS AND METHODS: The aorto-pulmonary window is a rare congenital cardiac malformation consisting of a connection between the ascending aorta and the main pulmonary artery. Based on 5 consecutive patients who were treated in our tertiary referral centre between 7/2000 and 11/2005, we report the echocardiographic features as well the limitations of this diagnostic method in the assessment of this rare malformation. RESULTS: Dilation of the left atrium and ventricle due to the large left-to-right-shunt was the characteristic echocardiographic feature in all patients with aorto-pulmonary window. In all patients we were able to visualise the window by 2D-echocardiography. Pulsed- and continuous-wave Doppler showed diastolic negative flow in the descending aorta and in systemic arteries due to left-to-right shunting in diastole via the aorto-pulmonary window. All 5 patients had significant associated cardiovascular malformations. They were accurately diagnosed by echocardiography. Coronary anomalies could be excluded noninvasively in all patients. CONCLUSION: Echocardiography is the method of choice for diagnosis of aortopulmonary window. Detection of aortopulmonary window, however, requires a systematic and careful investigation of all cardiovascular anatomic details, since this anomaly is frequently associated with substantial additional cardiac anomalies, which would by themselves be sufficient to explain the haemodynamic abnormalities of the patient. Cardiac catheterisation is required only in cases with inadequate information about coronary artery anatomy or in older patients with pulmonary hypertension, to determine the patient's suitability for surgical correction.

Aorta, Thoracic↗

Systematic assessment of atypical deletions reveals genotype-phenotype correlation in 22q11.2.

INTRODUCTION: Clinical variability associated with the common 22q11.2 microdeletion is well known, and has led to a broad application of FISH diagnostics with probes for loci TUPLE1 or D22S75 (N25), although, rarely reported atypical deletions associated with the same phenotypic spectrum would not be discovered by these probes. As most types of 22q11.2 deletions occur between low copy repeats within the region (LCR22), we assumed that atypical deletions should be more common than has been reported. To address this question and the possibility of a deletion size related genotype-phenotype correlation, we systematically assessed the frequency of typical and atypical 22q11.2 deletions in a large cohort of patients. METHODS: We used a set of 10 fluorescent in situ hybridisation (FISH) DNA probes, capable of detecting all reported and hypothetical deletions between the LCR22, and analysed 350 patients. Deletion sizes in atypical deletions were established by use of further FISH probes. Frequency of certain atypical deletions was analysed in controls by FISH and quantitative PCR. RESULTS: Patients with conotruncal heart defects (ctCHD) and with typical VCFS phenotype showed the common 3 Mb or nested 1.5 Mb deletions (in 18.5% and 78.6%, respectively), but no atypical deletion, while 5% (3/63) of patients with a mildly suggestive, atypical phenotype showed atypical distal deletions, which were not detected in patients with mental retardation of unknown origin or in healthy controls. DISCUSSION: These statistically significant differences demonstrate that atypical distal 22q11.2 deletions are very uncommon in patients with ctCHDs, while atypical congenital heart defects and mild dysmorphism are recognisable feature of atypical distal deletions. Further phenotype-genotype analysis disclosed association of significant developmental delay with the distal part of the common deletion region, and choanal atresia and atypical CHDs with the adjacent distal deletion region.

Chromosomes, Human, Pair 22↗

Recanalisation of bilateral superior vena cava after total cavopulmonary connection. Interventional occlusion with the Amplatzer VSD Occluder.

UNLABELLED: Formation of systemic to pulmonary venous or systemic venous left atrial collaterals frequently occurs in patients after Glenn or Fontan-type operations. Embolization with detachable metal coils is the therapy of choice for the closure of small vessels. These devices however are not appropriate for the occlusion of large collaterals, e. g. recanalized bilateral caval veins. We report two patients who presented late after Fontan-type operations with a gradual decrease in oxygen saturation due to recanalisation of bilateral caval veins. Interventional closure of these large veins was carried out successfully with the use of 8 mm Amplatzer muscular VSD Occluders, resulting in an increase of arterial oxygen saturations. CONCLUSION: The closure of recanalized bilateral superior caval veins after Fontan procedures is possible without technical problems by means of the Amplatzer muscular VSD Occluder. In order to avoid future formation of venous collaterals via the azygos or hemiazgos system, the occluder should be placed in the vena cava below the orifice of the azygos/ hemiazygos vein.

Adult↗

[Cervical origin of the subclavian artery: echocardiographic diagnosis in patients with monosomy 22q11].

OBJECTIVE: To assess the sensitivity and specificity of echocardiography in the detection of anomalies of the subclavian artery (cervical origin, aberrant origin from the descending aorta or isolation) in patients with monosomy 22q11. METHOD: From 1/1998 until 03/2002 we examined 57 patients with conotruncal cardiac malformations. 30 patients had pulmonary atresia and ventricular septal defect (53 %), 13 interrupted aortic arch (23 %), 9 tetralogy of Fallot (16 %) and 5 common truncus arteriosus (9 %). Echocardiographic examination included identification of the laterality of the aortic arch as well as examination of the origin of the brachiocephalic vessels. The results were compared with angiographic and intraoperative findings. Median age at echocardiographic investigation was 74 days (range 1 d - 33.4 yrs.). RESULTS: Laterality of the aortic arch was assessed correctly in all patients. 20/57 patients had a right-sided aortic arch (35 %). Echocardiography detected all anomalies of the subclavian artery (14/57 patients, 25 %, sensitivity 100 %) and excluded these anomalies correctly in 43 patients (specificity 100 %). Exact classification of the anomaly of the subclavian artery was possible in 6/6 patients with a cervical origin of the artery and in 7/8 patients with aberrant origin from the descending aorta. Monosomy 22q11 was diagnosed in 21 patients (37 %). CONCLUSION: Echocardiography achieves a high sensitivity in the detection of anomalies of the subclavian artery. The diagnosis of cervical origin of the artery, in particular, can be easily established. As this anomaly appears to be a specific marker for monosomy 22q11, echocardiography facilitates reliable identification of these patients in clinical practice.

Adolescent↗

Current treatment and prognosis in children with functionally univentricular hearts.

For more than 30 years Fontan-type procedures have been performed for surgical treatment in patients with functionally univentricular hearts. Advances in proper patient selection, staging of the Fontan palliation, and modifications of the surgical technique resulted in continuous improvement of the surgical results during the past two decades. However, increasing experience with medium term and long term follow-up of the Fontan circulation has drawn attention to a number of sequelae and chronic complications affecting a significant number of patients.

Fontan Procedure↗

Double-chamber right ventricle associated with severe fetal cardiac failure.

Fetal cardiac defects leading to intrauterine cardiac failure and subsequent fetal hydrops are rare. We report an unusual case of a double-chamber right ventricle leading to progressive fetal cardiac insufficiency and hydrops. The patient was first managed conservatively. Delivery by Cesarean section was performed for a pathological fetal heart-rate tracing at 28 weeks of gestation. The newborn died 4 h postpartum due to generalized cardiac insufficiency.

Adult↗

Excision of the coronary orifices in arterial switch operation: "O" like obstructive and "U" like unobstructive?

BACKGROUND: Stenoses of the neo-pulmonary artery (NPA) may complicate follow-up of the arterial switch operation (ASO). It is unknown whether the type of patch covering the coronary excision defects ("O"- or "U"-shaped) might influence this complication. METHODS: Echocardiographically and invasively measured NPA pressure-gradients were evaluated retrospectively in 95 children after ASO. Median follow-up was 5.8 years. Defects had been covered with pericardial patches: O/O and U/U (left/right) 34 x each, and 27 x in mixed combinations. The frequency of NPA stenoses requiring re-interventions was registered. RESULTS: Median of the peak instantaneous echocardiographic pressure gradient was 23 mmHg (interquartile range, IQR: 16 - 49, n = 34) in O/O, and 19 mmHg (IQR: 13 - 23, n = 34) in U/U; p < 0.034, t-test. Invasively measured gradients were 49 mmHg (IQR: 17 - 65, n = 12) in O/O, and 12 mmHg (IQR: 7-21, n = 28) in U/U; p < 0.001. One child per O/O- and U/U-group underwent balloon angioplasty of the neo-pulmonary root. Five children of the O/O-group had to undergo repeat surgery, whereas only one child in the U/U-group required repeat surgery ( p < 0.34). CONCLUSIONS: The preferential type of covering the NPA coronary excision sites in ASO should be U-shaped.

Anastomosis, Surgical↗

[Asymptomatic cor triatriatum in a 2 1/4 year old patient].

We report on an asymptomatic 2 1/4 year old girl. Echocardiography revealed cor triatriatum with a membrane separating the left atrium. Transesophageal echocardiography demonstrated 3 large perforations of the intraatrial membrane. Using Doppler sonography, no pressure gradients across these orifices were identified. Obstruction of the intraatrial membrane and pulmonary hypertension were excluded by cardiac catheterization. We therefore decided against surgical resection of the membrane and to follow the patient noninvasively by echocardiography. Follow-up over 18 months revealed no development of an obstruction across the intraatrial membrane. Our case shows that immediate surgical correction is not necessary in all patients with cor triatriatum. Conservative management of these patients requires full evaluation of the hemodynamics and careful follow-up examinations by echocardiography.

Child, Preschool↗

Intestinal perforations in a premature infant caused by Bacillus cereus.

Although Bacillus cereus is a ubiquitous bacterium, the incidence of neonatal infections is very low with only a few cases of B. cereus infections in neonates reported in the literature. We report the case of a premature infant with multiple intestinal perforations and an abdominal B. cereus infection. The initial course was characterized by severe cardiovascular shock, anemia, thrombocytopenia and disseminated intravascular coagulation, leading to periventricular leukomalacia, alopecia capitis and toxic epidermal necrolysis. The possible role of B. cereus-associated enterotoxins for the clinical manifestations are discussed. Our case confirms previous reports of severe clinical symptoms in B. cereus infection in premature neonates. We speculate that the systemic complications of B. cereus infection are at least partly related to the effect of B. cereus-associated enterotoxins.

Abnormalities, Multiple↗

[Echocardiographic diagnosis of the aorto-left ventricular tunnel].

AIM/METHOD: The aorto-left ventricular tunnel (ALVT) is a rare congenital cardiac malformation with clinical findings of severe aortic insufficiency. We report the echocardiographic differentiation of different anatomical variants of ALVT in two infants. RESULTS: Echocardiography in both patients demonstrated severe enlargement of the ascending aorta and the left ventricle. In the first patient the ALVT originated from the ascending aorta above the right coronary sinus and entered the left ventricle just below the aortic valve. In the second patient the ALVT originated above the left coronary sinus and took a lateral course to the left ventricle. Colour-Doppler-sonography in both patients confirmed a systolic-diastolic flow across the tunnel. Many patients have associated cardiac defects. Exact determination of the morphology of the aortic valve and coronary arteries is mandatory for surgical repair. Postoperative follow-up studies focus on the function of the aortic valve and the left ventricle. CONCLUSION: Differentiation of different anatomical variants of ALVT is possible trough echocardiography. Cardiac catheterization is required only in cases with inadequate information about coronary artery anatomy.

Aortic Valve↗

Determination of the pressure gradient in children with coarctation of the aorta by low-field magnetic resonance imaging.

During the past few years magnetic resonance imaging (MRI) has gained increasing importance in the noninvasive examination of congenital heart defects. Practically all existing examinations have been carried out with a magnetic field strength exceeding 1 (T high-field MRI). Flow quantification is considered to be an advanced MRI application and, in the past, has been available for high-field systems only. Therefore until recently, functional examinations such as MRI tomographic flow quantification were reported exclusively for high-field MRI units. From December 1998 to December 1999, nine patients (five girls and four boys, mean age 130 plus minus 3.6 months, range 62-185 months) were investigated by means of MRI after a previous surgical repair or interventional balloon dilatation of a coarctation of the aorta (mean postinterventional time period 23 plus minus 0.4 months). The examination was carried out without sedation in an open low-field unit (Siemens Magnetom Open 0.2 T). Cardiac-triggered spin-echo sequences were used with a 3-mm to 7-mm slice thickness in an axial and a double oblique plane. The measurement of the immediate poststenotic flow velocity was done by flow-sensitive sequences developed for the study (phase-sensitive flow measurement sequences: TE, 6-12 msec; TR, 50 msec; flip angle, 60 degrees; Vmax, 200-1200 cm/sec; two acquisitions). All patients were examined on the same day with comparative echocardiographic procedures. In all cases, an excellent anatomical evaluation of the aortic arch was possible. The diameters of the residual stenosis were measured by MRI and correlated well r = 0.95; p ? 0.001; mean difference 0.44 +/- 2.47 mm) with echocardiographic results. No wall damage was observed in any of the cases studied. The pressure gradient of the stenosis calculated from the flow sequence was between 17 and 50 mmHg and corresponded well (r = 0.93; p = 0.001; mean difference 0.67 +/- 11 mmHg) with the results obtained from echocardiography. The study demonstrates that examination of the aortic arch is possible in a low-field MRI system, with its significant advantages (lower patient discomfort and more cost-effective examination). In addition, a quantitative flow measurement in low-field MRI was realized for the first time. Low-field MRI therefore seems to be a good, noninvasive method for examining patients with a poor echocardiographic representation of the aortic arch.

Adolescent↗

[Tetralogy of Fallot with right pulmonary artery origin from the ascending aorta: noninvasive diagnosis and surgical correction in a 7-week-old infant].

Anomalous origin of one pulmonary artery from the ascending aorta is a rare anomaly which is almost always associated with hypertension in the contralateral pulmonary artery originating from the right ventricle. We report echocardiographic evaluation of an infant with tetralogy of Fallot and aortic origin of the right pulmonary artery. Since all relevant information regarding anatomy and hemodynamics could be obtained by echocardiography, cardiac catheterization and angiography were unnecessary. Surgical correction including transatrial patch closure of the ventricular septal defect, resection of the infundibular stenosis and direct reimplantation of the right pulmonary artery was performed successfully at the age of 7 weeks. The postoperative course was uneventful and persistent pulmonary hypertension was excluded by echocardiography. Our case shows that complete echocardiographic evaluation is possible in infants with this complex cardiac malformation. We recommend reserving cardiac catheterization for those patients with echocardiographic evidence of significant elevation of pulmonary vascular resistance. In order to avoid irreversible pulmonary vascular changes early surgical correction within the first 3 months of life should be performed in all children with aortic origin of a pulmonary artery including those with associated tetralogy of Fallot.

Aorta↗

[Advances in interventional occlusion of persistent ductus arteriosus: comparison of results using different occlusion devices].

This report describes our results with transcatheter closure of patent ductus arteriosus between March 1993 and May 2000 including our early experience with the Amplatzer duct occluder. One hundred and sixty-six consecutive procedures were performed in 160 patients. The mean age was 6.8 years (range 0.8 to 26.2), mean weight 24.3 kg (range 7.7 to 84.0). Single or multiple coils were implanted successfully in 114 cases, a Rashind double umbrella in 35 patients, and an Amplatzer duct occluder in 16 patients. After failure to implant coils in one patient, a second attempt with a Rashkind double umbrella was successful. Complete closure of the patent ductus arteriosus was achieved in a total of 148 patients (92.5%), mean fluoroscopy time was 13.7 min (range 3.1 to 126 min). In 144 patients (90.0%), occlusion without residual shunting was achieved by the first interventional approach. Angiography showed immediate closure in 44%, echocardiography within 48 h revealed complete closure in additional 28%. In a further 18%, a residual shunt disappeared spontaneously in the following months. In five patients a second procedure was performed to terminate residual shunting after placement of a Rashkind occluder system by coils. In three patients, the residual shunt resolved. In 12 patients (7.5%) echocardiography showed a residual shunt 2-1259 days after interventional approach. Occlusion rates of the different devices were 83% for the Rashkind occluder, 92% for detachable coils, and 100% for the Amplatzer duct occluder. Coil embolisation into the pulmonary artery occurred in two patients, interventional removal was successful in one of them. There were no further complications. According to our experience interventional occlusion of patent ductus arteriosus is highly effective and associated with a low complication rate. Transcatheter closure using the Amplatzer duct occluder seems to be safe and effective also in small children with a body weight of 8 kg and a large ductus diameter. Compared to the total group of patients, the occlusion rate of the Amplatzer duct occluder was significantly higher (p = 0.005), and of the Rashkind occluder system significantly lower (p = 0.026). Therefore, we recommend the use of detachable coils in patients with small ductus (diameter < or = 2 mm) and the Amplatzer duct occluder in those with a larger ductus. Transcatheter closure of the patent ductus arteriosus according to this regimen should achieve occlusion rates above 95%.

Adolescent↗