PubMed Health⌕ Search

Biomedical subjects

M Hugel

Publications and source records attributed to M Hugel.

7 recordsLinked to original sources

Carotid angioplasty and stenting under protection. Techniques, results and limitations.

A carotid stenosis is responsible for about 30% of strokes occurring. Carotid endarterectomy (CEA) is considered to be the gold standard treatment of a carotid stenosis. Carotid angioplasty and stenting (CAS) is emerging as a new alternative treatment for a carotid artery stenosis, but the risk of neurological complications and brain embolism remains the major drawback to this procedure. Therefore, in order to reduce the risks, we need: 1) good indications, good patient and lesion selection; 2) correct techniques; 3) brain protection devices (cerebral protection devices should be routinely used and are mandatory for any procedure); 4) 3 types of protection devices are available, but filters are the most commonly used (all protection devices have limitations and cannot prevent from all embolic events; however, neurological complications can be reduced by 60%); 5) a good choice of the stent and correct implantation (all stents are not equivalent and have different geometrical effects); 6) pharmacological adjuncts; 7) a good team. Recent studies have shown that CAS has superior short-term outcomes than CEA in high surgical risk patients, but there are enough reported data to conclude that CAS is also not inferior to CEA in low-risk patients. CAS under protection is the standard of care and is maybe becoming the gold standard treatment of a carotid stenosis at least in some subgroups of patients.

Angiography↗

Percutaneous transluminal angioplasty using a new peripheral cutting balloon for stenosis of arch vessels in aorto arteritis.

Percutaneous transluminal angioplasty (PTA) with or without stenting of steno-occlusions in the supra-aortic arch vessels in aortoarteritis is associated with higher residual stenosis and restenosis, particularly in those with diffuse disease. The use of the new peripheral cutting balloon (Boston Scientific Interventional Technologies, San Diego, CA, USA) in these lesions in aortoarteritis has not been described. We report here the first 2 cases of stand alone cutting angioplasty for 2 patients (3 arteries). One patient presented with a critical stenosis of the common carotid artery. We obtained a good immediate result but a restenosis appeared at 6 months, easily treated by a new angioplasty with cutting balloon and stent implantation. The second patient had an occlusion of the subclavian artery associated with a severe ostial vertebral artery stenosis. The immediate result was excellent and the 6-month clinical and angiographic control showed no restenosis.

Adult↗

Protected renal stenting with the PercuSurge GuardWire device: a pilot study.

PURPOSE: To evaluate the feasibility and safety of renal artery angioplasty and stenting utilizing a distal protection device to reduce the risk of intraprocedural atheroembolism. METHODS: Twenty-eight hypertensive patients (18 men; mean age 71.3 +/- 8.6 years, range 49-87) with atherosclerotic renal artery stenosis (4 bilateral) underwent angioplasty and stenting with distal protection in 32 renal arteries (29 ostial lesions). The lesion was crossed with a GuardWire temporary occlusion balloon, which was inflated to provide parenchymal protection. Generated debris was aspirated and analyzed. Blood pressure and serum creatinine levels were followed. RESULTS: Immediate technical success was 100%. All lesions were stented, either directly (14 ostial lesions), after predilation (15 ostial lesions), or owing to suboptimal angioplasty (3 nonostial lesions). Visible debris was aspirated from all patients. Mean particle number and diameter were 98.1 +/- 60.0 per procedure (range 13-208) and 201.2 +/- 76.0 microm (range 38-6206), respectively. Mean renal artery occlusion time was 6.55 +/- 2.46 min (range 2.29-13.21). Mean follow-up was 6.7 +/- 2.9 months (range 2-17). Systolic and diastolic blood pressure declined from 167.0 +/- 15.2 and 103.0 +/- 12.0 mm Hg, respectively, to 154.7 +/- 12.3 and 93.2 +/- 6.8 mm Hg after the procedure. The mean creatinine level dropped from 1.34 +/- 0.35 mg/dL preprocedurally to 1.22 +/- 0.36 mg/dL at 24 hours and remained constant. At 6-month follow-up, renal function did not deteriorate in any patient, whereas 5 patients with baseline renal insufficiency improved after the procedure. CONCLUSIONS: These preliminary results suggest the feasibility and safety of distal balloon occlusion during renal interventions to protect against atheroembolism. This technique's beneficial effects should be evaluated by randomized studies.

Aged↗

Angioplasty and stenting of the extracranial carotid arteries.

We performed percutaneous transluminal angioplasty and stenting in patients with carotid artery stenosis to determine the efficacy of these techniques as an alternative to surgical endarterectomy. From April 1995 through July 1999, 315 carotid angioplasty procedures were performed (right, 151; left, 164) in 290 patients ranging in age from 40 to 93 years. Of these patients, 42% were symptomatic and 58% were asymptomatic. Twenty-five patients underwent bilateral procedures. The mean percentage of stenosis was 82.3%+/-8.7% SD. Angioplasty and stenting were performed without cerebral protection in 165 arteries and with protection in 150. Two methods of protection were used: the Theron technique and the PercuSurge Guardwire temporary occlusion and aspiration system. Balloon dilation and stent placement were successful in 289 patients; in the last patient, severe arterial tortuosity prevented catheterization and stenting. We observed 13 periprocedural neurologic complications due to ischemia (4.2%): 4 transient ischemic attacks (1.3%), 4 minor strokes (1.3%), and 5 major strokes (1.6%), including 1 death. At 6 months, 210 patients had a follow-up angiogram (155) or duplex ultrasound (55). There were 10 restenoses (4.7%), 1 of which was symptomatic and 2 of which showed mild compression of a Palmaz stent without marked stenosis. Primary and secondary 4-year patency rates were 96% and 99%, respectively. These results demonstrate acceptable mortality and morbidity rates related to carotid angioplasty and stenting. However, we found the risk of embolic stroke to be substantial. Cerebral protection may improve the results of carotid angioplasty and expand the indications for this procedure.

Aged↗

Carotid stenting with cerebral protection: first clinical experience using the PercuSurge GuardWire system.

PURPOSE: To study the feasibility and safety of carotid angioplasty and stenting using a new cerebral protection device that temporarily occludes the distal internal carotid artery (ICA). METHODS: Forty-eight high-risk patients (39 men, mean age 69.1 +/- 8 years, range 54 to 86) with 53 ICA stenoses underwent percutaneous angioplasty and stenting via the femoral approach under cerebral protection afforded by a 0.014-inch GuardWire balloon occlusion device. Mean stenosis was 82.1% +/- 9.65% (range 70 to 96) and mean lesion length was 16.0 +/- 7.5 mm (range 6 to 50). Thirty-three (62%) lesions were calcified, and 38 (72%) were ulcerated. Thirty-two (60%) of the lesions were asymptomatic. With the occlusion balloon inflated in the distal ICA, the lesion was dilated and stented. The area was cleaned by aspiration and flushed via an aspiration catheter advanced over the wire. Blood samples were collected from the external carotid artery (ECA) and analyzed to measure the size and number of particles collected. Computed tomography and neurological examinations were performed the day after the procedure. RESULTS: Immediate technical success was achieved in all patients with the implantation of 38 Palmaz stents, 8 Expander stents, and 11 Wallstents. Carotid occlusion was well tolerated in all patients but 1 who had multiple, severe carotid lesions and poor collateralization. Mean cerebral flow occlusion time was 346 +/- 153 seconds during predilation and 303 +/- 143 seconds during stent placement. Total mean flow occlusion time was 542 +/- 243 seconds. One immediate neurological complication (transient amaurosis) occurred in a patient who had an anastomosis between the external carotid (EC) and ICA territories. Debris was removed in all patients with a mean 0.8-mm diameter catheter. CONCLUSION: Cerebral protection with the GuardWire device is easy, safe, and effective in protecting the brain from cerebral embolism. Larger studies are warranted.

Aged↗