PubMed HealthSearch

Biomedical subjects

M Imran

Publications and source records attributed to M Imran.

13 recordsLinked to original sources

Cardioprotective effect of cromakalim (potassium channel opener) in isoproterenol induced myocardial infarction in rats.

Animals pretreated with cromakalim (1 mg/kg,po) along with isoproterenol (85 mg/kg,sc) showed less myocardial degenerative changes on histopathological examinations when compared with those treated with isoproterenol alone. Cromakalim's beneficial effects on myocardium were in dose-dependent manner. Administration of cromakalim (po) lowered significantly the serum LDH and SGOT and depleted intracytoplasmic glycogen as demonstrated by periodic schiff staining procedure. Increase in blood clotting time was highly significant (P less than 0.001). The results suggest cardioprotective effect of cromakalim in isoproterenol induced myocardial infarction.

Animals

Automatic implantable cardioverter-defibrillator structural characteristics.

There are a number of equipment options and surgical techniques available for automatic implantable cardioverter-defibrillator implantation. The system can be successfully used even in problem cases where restrictions may be imposed because of physical build or the presence of other implanted devices. The sensing requirements and energy output of the units can be tailored to the exact needs of the particular patient. Battery life and device function are easily monitored periodically following implantation, making possible elective replacement of the pulse generator when the batteries become depleted.

Arrhythmias, Cardiac

The automatic implantable defibrillator: local ventricular bipolar sensing to detect ventricular tachycardia and fibrillation.

The first-generation automatic implantable defibrillator implanted in man sensed arrhythmias by monitoring a transcardiac electrocardiographic signal. This sensing system reliably detected ventricular fibrillation and sinusoidal ventricular tachycardia but failed to sense all nonsinusoidal ventricular tachycardias. To solve this problem, a new ventricular tachycardia detection scheme was developed using a local ventricular bipolar electrogram and electronic circuits using rate averaging and automatic gain control to permit sensing of electrograms down to 0.1 mV. This detection scheme was tested during electrophysiologic studies in 11 patients with ventricular tachycardia and fibrillation. All 22 episodes of induced ventricular tachycardia with a rate above the selected cutoff were detected after an average of 5.1 +/- 1.8 seconds. No episodes below the rate cutoff were detected. The bipolar circuits also reliably detected ventricular fibrillation. Arrhythmia detection and signal quality in 9 patients receiving automatic defibrillators using the new bipolar rate detection circuit were compared with the findings in 5 patients previously receiving units that sensed arrhythmias using the transcardiac electrocardiographic signal. Compared with the transcardiac monitoring units the newer bipolar units had shorter and more uniform sense times (5.5 +/- 1.4 versus 12.2 +/- 7.1 seconds). It is concluded that malignant ventricular tachyarrhythmias can be sensed accurately using bipolar rate detection and that this system has numerous advantages over the previously used transcardiac electrocardiographic signal.

Aged

Clinical evaluation of the internal automatic cardioverter-defibrillator in survivors of sudden cardiac death.

An R-wave synchronous implantable automatic cardioverter-defibrillator (IACD) was evaluated in 12 patients with repeated episodes of cardiac arrest who remained refractory to medical and surgical therapy. Seven men and 5 women, average age 61 years, surgically received a complete IACD system. Coronary artery disease was found in 11 and the prolonged Q-T syndrome in 1. The average ejection fraction was 34%, and 6 patients had severe congestive heart failure (New York Heart Association class III or IV). The IACD is a completely implantable unit consisting of 2 bipolar lead systems. One system uses a lead in the superior vena cava and on the left ventricular apex through which the cardioverting pulse is delivered. The second system employs a close bipolar lead implanted in the ventricle for sensing rate. After the onset of ventricular tachycardia or fibrillation, the IACD automatically delivers approximately 25 J. Postoperative electrophysiologic study in 10 and spontaneous ventricular tachycardia in 1 patient demonstrated appropriate IACD function and successful conversion in all with an average of 18 +/- 4 seconds. The induced arrhythmias were ventricular tachycardia (160 to 300 beats/min) in 9 and ventricular fibrillation in 1. These data demonstrate that ventricular tachycardia, not ventricular fibrillation, was the predominant rhythm induced during programmed ventricular stimulation in these survivors of cardiac arrest and that the IACD effectively responded to a wide range of ventricular tachycardia rates as well as ventricular fibrillation. Use of the IACD offers an effective means of therapy for some patients who otherwise may not have survived.

Aged

Combined procedure of aspiration termination and laparoscopic sterilization.

Termination of pregnancy and laparoscopic sterilization has been performed in 101 women in a one-year period. The complication rate was low and the average stay in hospital was short. With close supervision and co-operation between the gynaecologist and the patient's general practitioner it is suggested that this is a safe and economic procedure.

Abortion, Therapeutic

Opium administration to infants in Peshawar region of Pakistan.

Use of opium for sedating infants in the North-West Frontier Province of Pakistan causes a grave public health problem. Among the infants hospitalized for opium overdosage, 22 were studied in detail, and their major clinical picture is presented in this paper. The effect of opium use on the nutritional status of these infants, or the relation of infant opium use to addiction in adult life, have not been assessed. It is, however, pointed out that opium overdosage of infants contributed to infant mortality. Despite emergency treatment, the lethality rate of opium overdosed infants was 40 per cent. It is emphasized that a preventive programme should be undertaken to educate parents who are ignorant of the dangers of opium administration to infants.

Child, Preschool

Improving intramuscular pH needle electrode stability.

An improved design for an intramuscular pH needle electrode, which slows the rate of accumulation of protein deposits and increases the stability of the needle electrodes, has been developed. To further stabilize the electrode, a counter EMF pulsing technique was also developed. As presently fabricated and used, needle electrodes remain stable for months in nonprotein solutions and for about 53 hours in albumin solutions.

Acid-Base Equilibrium