Behavior of nitric oxide infused at constant flow rates directly into a breathing circuit during controlled mechanical ventilation.

OBJECTIVES: This study was designed to test the hypothesis that the practice of infusing nitric oxide at constant flow rates directly into breathing circuits with intermittent (pulsatile) flow can lead to streaming and tidal pooling of the nitric oxide. This study was also designed to show the extent to which streaming and tidal pooling of nitric oxide affect nitric oxide delivery. DESIGN: A series of five in vitro experiments was performed. For each experiment, either one or two features of the nitric oxide delivery/sampling system were varied, and the effects of these variations were evaluated with regard to measured nitric oxide concentration changes. The results from each experiment were analyzed using either one- or two-factor analysis of variance. SETTING: University research laboratory. SUBJECTS: Breaths were provided by a mechanical ventilator that was connected to a lung model. A standard, corrugated, adult breathing circuit was used. Gas samples were obtained from either the lung model's bellows or selected sites within the breathing circuit. Nitric oxide concentrations were measured, using an electrochemical gas analyzer. INTERVENTIONS: The system features that were varied included the cross-sectional position of the sampling site within the breathing circuit, the distance between the infusion port and the sampling site, the breathing frequency, the distance between the Y-piece and the infusion port, and the airway (deadspace) volume. MEASUREMENTS AND MAIN RESULTS: Streaming of nitric oxide within the breathing circuit was detected as far as 25 cm downstream of the infusion site (p < .0001). Pooling of nitric oxide was detected both near and downstream of the infusion site (p < .0001). Increasing the breathing frequency from 5 to 30 breaths/min increased mixing thoroughness (p < .005). Increasing the distance between the Y-piece and the infusion port from 15 to 180 cm decreased nitric oxide delivery to our lung model (p < .0001). Interestingly, increasing airway (deadspace) volume from 150 to 450 mL decreased nitric oxide delivery to our lung model (p < .0001). CONCLUSIONS: Estimates of nitric oxide delivery using a constant flow rate of nitric oxide infused directly into a breathing circuit during controlled mechanical ventilation can be confounded by streaming and tidal propagation of nitric oxide pools. Improved reproducibility of reported dose-response relationships is likely to be achieved through further study of nitric oxide behavior within the breathing circuits. Reduced toxicity associated with nitric oxide inhalation may also be achieved through a better understanding of this nitric oxide behavior.

Administration, Inhalation

Artificial surfactant for therapy in hydrocarbon-induced lung injury in sheep.

OBJECTIVE: To document the effect of administering artificial surfactant into the trachea, either by instillation or aerosolization, on acute lung injury experimentally induced with kerosene in sheep. DESIGN: Randomized, prospective, controlled study. SETTING: Research laboratory. SUBJECTS: Sheep (n = 24), weighing 8.5 to 25.2 kg (average 16.6). INTERVENTIONS: In anesthetized, tracheally intubated sheep with pulmonary and femoral artery catheters inserted, lung injury was induced by instilling kerosene (0.3 mL/kg) into the trachea. After 15 mins of spontaneous breathing, mechanical ventilation was instituted with a uniform F10(2) and a tidal volume of 10 mL/kg. Sheep were then assigned randomly to one of four regimens as follows: exogenous surfactant or saline (5 mL/kg each) was administered as a bolus intratracheally or by aerosolization for 6 hrs. MEASUREMENTS AND MAIN RESULTS: Arterial and mixed venous blood gases, pH, airway pressure, and static respiratory system compliance were measured and compared between aerosol saline and aerosol surfactant and between bolus saline and bolus surfactant. For all variables except static respiratory system compliance, the hourly rate of change from 15 mins, 1 hr, and 6 hrs after kerosene instillation was determined for each animal, and group rank sums of hourly rates of change were compared. For static respiratory system compliance, the slope of the pressure-volume curve with volumes of 100, 200, 300, 400, and 500 mL was computed for each animal at baseline and at 3 and 6 hrs after kerosene instillation. Group rank sums for static respiratory system compliance at 3 and 6 hrs were compared. Also, the 3- and 6-hr static respiratory system compliance values at each of the volumes were compared. With saline, six of eight sheep died; with surfactant, no sheep died (p = .001). When compared with saline at 15 mins, 1 hr, and 6 hrs after kerosene instillation, surfactant, regardless of whether administered by aerosol or bolus, significantly increased rate of change of arterial oxygen saturation, mixed venous oxygen saturation, and PO2. CONCLUSIONS: In the present animal study, artificial surfactant was an effective treatment for hydrocarbon aspiration. Aerosolized surfactant achieved results similar to instilled surfactant but at a lower total dose.

Aerosols

Tracheal pressure triggering a demand-flow continuous positive airway pressure system decreases patient work of breathing.

OBJECTIVES: Triggering a ventilator "ON" at the carinal end of the endotracheal tube decreases imposed work of breathing by bypassing the resistance imposed by the breathing circuit and the endotracheal tube. We compared work of breathing during spontaneous ventilation between three methods of triggering the ventilator "ON": a) conventional pressure triggering from inside the ventilator; b) flow-by triggering; or c) tracheal pressure triggering at the carinal end of the endotracheal tube. We hypothesized that the work of breathing would be substantially decreased with tracheal pressure triggering compared with conventional pressure and flow-by methods in patients receiving continuous positive airway pressure. DESIGN: Clinical, prospective study. SETTING: University teaching hospital. PATIENTS: Fourteen adults diagnosed with acute respiratory failure. INTERVENTIONS: All patients were breathing spontaneously at an FIO2 of 0.30 to 0.40 and received 5 cm H2O of continuous positive airway pressure. Three different methods of triggering the ventilator while set in the continuous positive airway pressure mode were administered in random order. MEASUREMENTS AND MAIN RESULTS: Real-time measurements of esophageal pressure and tidal volume were integrated with a respiratory monitor (CP-100, Bicore, Riverside, CA) that uses the Campbell diagram to calculate total work of breathing. Imposed work of breathing was calculated by integrating tidal volume with the pressure at the carinal end of the endotracheal tube. Physiologic work of breathing was calculated by subtracting imposed work of breathing from the total work of breathing. Breathing frequency, the index of rapid shallow breathing (breathing frequency/tidal volume), peak inspiratory flow rate demand, exhaled minute ventilation, and the duration of respiratory muscle contraction assessed by the ratio of inspiratory time to total cycle time were also measured. Data were analyzed by Friedman's repeated-measures analysis of variance on ranks. Alpha was set at .05 for statistical significance. Imposed work of breathing decreased to approximately zero during tracheal pressure triggering. As a result, total work of breathing decreased by approximately 40% compared with the flow-by and conventional methods. During tracheal pressure triggering only, airway pressure increased above baseline pressure to approximately 11 cm H2O, which resembled pressure-support ventilation. Also, during tracheal pressure triggering, tidal volume and peak inspiratory flow rate were significantly increased, while the pressure-time product and the index of rapid shallow breathing were significantly decreased. Hemodynamic status and oxygen saturation were not clinically affected. CONCLUSIONS: The tracheal pressure triggering of a demand-flow continuous positive airway pressure system creates an effect similar to pressure-support ventilation that significantly decreases imposed work of breathing and, thus, total work of breathing. We recommend moving the triggering site of the ventilator to the carinal end of the endotracheal tube.

Acute Disease

A new pediatric respiratory monitor that accurately measures imposed work of breathing: a validation study.

OBJECTIVE: A new, microprocessor-controlled respiratory monitor (model CP-100 Pediatric, Bicore Monitoring Systems, Irvine, CA) that measures imposed work of breathing and a variety of respiratory parameters for pediatric patients receiving ventilatory support has recently been developed. To validate its accuracy, measurements obtained using this monitor were compared with those obtained using conventional laboratory equipment. METHODS: An in vitro lung model was used to simulate spontaneously breathing pediatric patients ranging from infancy to 10 years of age. Tidal volume, respiratory rate, and peak inspiratory flow rates were simulated in a stepwise manner. Values for imposed work, tidal volume, peak inspiratory flow rate, and change in airway pressure for both methods were compared using regression analysis. RESULTS: The coefficients of determination (r2) describing the relationships of both methods of measuring imposed work, tidal volume, peak inspiratory flow rate, and the change in airway pressure ranged from 0.99 to 1.00, and were highly significant (p < 0.001). For all measurements, bias was minimal and precision was calculated. CONCLUSIONS: Our data reveal that this pediatric respiratory monitor accurately measures imposed work of breathing, as well as tidal volume, flow rate, and airway pressure. Imposed work of breathing measurements obtained from the monitor may be used to adjust pressure support ventilation, so that the imposed work of the breathing apparatus is reduced to zero and the patient's total work of breathing is thus decreased.

Child

Automatic mechanical device to standardize active compression-decompression CPR.

STUDY OBJECTIVE: To develop an automatic mechanical device capable of performing active compression-decompression (ACD) CPR in laboratory animals. DESIGN: A swine model was used to study standard and ACD CPR. One-minute periods of standard mechanical chest compressions were alternated with mechanical ACD CPR. SETTING: University hospital laboratory. INTERVENTIONS: A commercially available device that provided standard chest compressions only was modified to deliver ACD CPR. RESULTS: The absolute difference in intrapleural pressure and tidal volume almost doubled during ACD CPR compared with that with standard CPR. CONCLUSION: The presence of a greater negative change in intrapleural pressure confirmed that active decompression of the chest had occurred and that the device was capable of performing ACD CPR. The device provides consistent rate, depth, force, and duty cycle.

Animals

Simple method to measure total expiratory time constant based on the passive expiratory flow-volume curve.

OBJECTIVE: In intubated, mechanically ventilated patients, inspiration is forced by externally applied positive pressure. In contrast, exhalation is passive and depends on the time constant of the total respiratory system. The expiratory time constant is thus an important determinant of mechanical ventilation. The aim of this study was to evaluate a simple method for measuring the expiratory time constant in ventilated subjects. DESIGN: Prospective study using a lung simulator and ten dogs. SETTING: University hospital. SUBJECTS: Commercially available lung simulator and ten greyhound dogs. INTERVENTIONS: Different expiratory time constants were set on the lung simulator. In the dogs, the endotracheal tube was clamped to increase airways resistance by 22.5 cm H2O/(L/sec) and the lungs were injured with hydrochloric acid to decrease total respiratory compliance by 16 mL/cm H2O. This procedure resulted in a wide range of expiratory time constants. MEASUREMENTS AND MAIN RESULTS: Pneumotachography was used to measure flow and volume. The ratio of exhaled volume and peak flow was calculated from these signals, corrected for the limited exhalation time yielding the "calculated expiratory time constant" and compared with the actual expiratory time constant. The typical error was +/- 0.19 sec for the lung simulator and +/- 0.15 sec for the dogs. CONCLUSIONS: The volume and peak flow corrected for limited exhalation time is a good estimate of the total expiratory time constant in passive subjects and may be useful for the titration of mechanical ventilation.

Airway Resistance

Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing.

STUDY OBJECTIVE: We evaluated the difference in work of breathing (WOB) during spontaneous ventilation with continuous positive airway pressure (CPAP) among three methods of triggering the ventilator: conventional pressure triggering, tracheal pressure triggering, and flow-by triggering. METHODS: In an in vitro model of the respiratory system consisting of a bellows (lungs) in a plastic canister (chest wall), spontaneous ventilation was simulated with a piston-driven pump (respiratory muscles). Data were recorded during CPAP of 5 cm H2O (model 7200ae ventilator, Puritan-Bennett, Overland Park, Kan) at peak sinusoidal inspiratory flow rate demands of 60 and 80 L/min and airway resistances of 5 and 20 cm H2O/L/s, with the demand flow system triggered by conventional pressure, tracheal pressure, or flow. Under each condition, tidal volume, pressure-time product (PTP), WOB, and changes in intrapleural pressure (Ppl) and airway pressure were recorded in real time by means of a computerized portable respiratory monitor (model CP-100, Bicore, Irvine, Calif). The Ppl was measured from within the canister, tidal volume by positioning a flow sensor between the Y-piece of the breathing circuit and the endotracheal tube (ETT), and airway pressure from a catheter attached to the flow sensor. The WOB was calculated by the monitor in real time. RESULTS: Changes in Ppl were greatest with conventional pressure triggering, less with flow-by triggering, and least with tracheal pressure triggering. The WOB was significantly lower (approximately 50%) with tracheal pressure triggering than with the other two methods. With tracheal pressure triggering only, an effect similar to that of pressure support ventilation (PSV) occurred, which accounted in part for the significant decrease in WOB. The PTP/breath ratio correlated strongly and was a good predictor of WOB (r2 = 0.95). CONCLUSIONS: Compared with conventional pressure and flow-by methods, triggering with tracheal pressure decreased WOB significantly. This method of triggering may improve patient-ventilator interaction.

Air Pressure

Does hypoxia or hypercarbia independently affect resuscitation from cardiac arrest?

STUDY OBJECTIVE: In a previous cardiopulmonary resuscitation (CPR) study in swine, ventilation was associated with improved rate of return of spontaneous circulation (ROSC) compared with nonventilated animals, which had greater hypoxia and hypercarbic acidosis. We used the same model to determine the independent effect of hypoxia and hypercarbic acidosis on ROSC after cardiac arrest. DESIGN: Laboratory model of cardiac arrest. SETTING: University teaching hospital laboratory. PARTICIPANTS: Domestic swine (23 to 61 kg). INTERVENTIONS: Twenty-four swine were randomly assigned to three groups receiving ventilation during CPR with 85% O2/15% N2 (control), 95% O2/5% CO2 (hypercarbia), or 10% O2/90% N2 (hypoxia). All animals had ventricular fibrillation for 6 min without CPR, then CPR with one of the ventilation gases for 10 min, then defibrillation. Animals without ROSC received epinephrine, 85% O2, CPR for another 3 min, and defibrillation. MEASUREMENTS AND RESULTS: During the tenth minute of CPR, the hypercarbic group had more mean (SD) arterial hypercarbia than the control group (PCO2, 47 +/- 6, compared with 34 +/- 6; p < 0.01), and greater mixed venous hypercarbia (PCO2, 72 +/- 14, compared with 59 +/- 8; p < 0.05), while mean arterial and mixed venous PO2 was not significantly different. The hypoxic group had significantly less mean arterial (43 +/- 9 compared with 228 +/- 103 mm Hg) and mixed venous (22 +/- 5 compared with 35 +/- 7 mm Hg) PO2 when compared with the control group (p < 0.01), while mean arterial and mixed venous PCO2 were not significantly different. Thus, the model succeeded in producing isolated hypercarbia without hypoxia in the hypercarbic group and isolated hypoxia without hypercarbia in the hypoxic group. The rate of ROSC was 6/8 (75%) for the control group, 1/8 (13%) for the hypercarbic group, and 1/8 (13%) for the hypoxic group (p < 0.02). CONCLUSIONS: Both hypoxia and hypercarbia independently had an adverse effect on resuscitation from cardiac arrest. In this model with a prolonged interval of untreated cardiac arrest, adequate ventilation was important for resuscitation.

Analysis of Variance

Breathing frequency and pattern are poor predictors of work of breathing in patients receiving pressure support ventilation.

OBJECTIVE: To evaluate the relationships between directly measured work of breathing (WOB) and variables of the breathing pattern commonly used at the bedside to infer WOB for intubated, spontaneously breathing patients treated with pressure support ventilation (PSV). DESIGN: In vivo measurements of the WOB were obtained on a consecutive series of adults. Breathing frequency (f), tidal volume (VT), the index of rapid, shallow breathing (f/V T), the duration of respiratory muscle contraction expressed as the ratio of inspiratory time over total respiratory cycle time (TI/TTOT), and a breathing pattern score (applied to approximately 50% of the patients) which ranks f, VT, sternocleidomastoid muscle activity, substernal retraction, and abdominal paradox on a scale were variables of the breathing pattern were also measured. The greater the breathing pattern score, the lower the WOB and vice versa. SETTING: Surgical ICUs in two university teaching hospitals. PATIENTS: Sixty-seven adults (42 men and 25 women, aged 20 to 78 years) who had acute respiratory failure from various etiologies were studied. All patients were breathing spontaneously receiving continuous positive airway pressure and PSV. INTERVENTIONS: Intraesophageal pressure (indirect measurement of intrapleural pressure) was measured with an esophageal balloon integrated into a nasogastric tube. VT was obtained by positioning a flow sensor between the "Y" piece of breathing circuit and the endotracheal tube. Data from these measurements were directed to a bedside respiratory monitor (Bicore; Allied Healthcare Products; Riverside, Calif) that calculates WOB using the Campbell diagram. Patients received PSV at levels deemed reasonable to unload the respiratory muscles. All measurements were obtained after 15 to 20 min at each level of PSV, averaged over 1 min, and then variables of the breathing pattern were regressed with directly measured values for WOB. RESULTS: All breathing pattern variables poorly predicted WOB as evidenced by the low values for the coefficients of determination (r2). Breathing frequency correlated positively with WOB (r = 0.47, p < 0.001) and predicted or explained only 22% (r2 = .22) of the variance in WOB. VT correlated negatively and f/VT and TI/TTOT each correlated positively with WOB. However, these variables predicted only 20 to 27% of the variance in WOB. The breathing pattern score correlated negatively with WOB and predicted only 43% of the variance in WOB. A prediction model taking all variables into consideration using multiple regression analysis predicted only 50% of the variance in WOB; thus, it too was a poor to moderate predictor of WOB. CONCLUSION: Our data reveal that WOB should be measured directly because variables of the breathing pattern commonly used at the bedside appear to be inaccurate and misleading inferences of the WOB. The clinical implication of these findings involves the traditional and empirical practice of titrating PSV based on the breathing pattern. We do not imply that the patient's breathing pattern should be ignored, nor undermine its importance, for it provides useful diagnostic information. It appears, however, that relying primarily on the breathing pattern alone does not provide enough information to accurately assess the respiratory muscle workload. Using the breathing pattern as the primary guideline for selecting a level of PSV may result in inappropriate respiratory muscle workloads. A more comprehensive strategy is to employ WOB measurements and the breathing pattern in a complementary manner when titrating PSV in critically ill patients.

Adult

Evaluation of a fiberoptic system for airway pressure monitoring.

OBJECTIVE: Our objective was to evaluate the accuracy of a novel fiberoptic system for airway pressure measurement at the carinal end of the endotracheal tube in an in vitro pediatric lung model. METHODS: A fiberoptic pressure measuring system was compared to the conventional method of measuring airway pressure with a pneumatic transducer using a test lung model. Pressure measurements were obtained using four endotracheal tubes of various internal diameters (ID) (3 to 6 mm) during simulated spontaneous and mechanical ventilation. Airway pressure was measured using both methods simultaneously and the results were compared by statistical analysis. RESULTS: Airway pressure measured by the fiberoptic system was not significantly different from measurements obtained by the pneumatic transducer except when using the 3-mm and 4-mm ID endotracheal tubes during mechanical ventilation. CONCLUSIONS: We conclude that the fiberoptic system provides accurate and precise measurement of airway pressure during spontaneous and mechanical ventilation. Additionally, the statistically significant differences obtained for 3- and 4-mm tubes are not large enough to be clinically significant. The fiberoptic system offers advantages over the pneumatic system for measuring the airway pressure. These advantages include decreased chance of false pressure measurement secondary to occlusion with water or mucous, less chance of kinking, and possibly, more rapid response to pressure changes due to the mechanical ventilator.

Airway Resistance

Ventilation caused by external chest compression is unable to sustain effective gas exchange during CPR: a comparison with mechanical ventilation.

OBJECTIVE: To compare the tidal volume, minute ventilation, and gas exchange caused by mechanical chest compression with and without mechanical ventilatory support during cardiopulmonary resuscitation (CPR) in a laboratory model of cardiac arrest. DESIGN: A laboratory swine model of CPR was used. Eight animals with and eight animals without mechanical ventilation received chest compression (100/min) for 10 min. Coronary perfusion pressure, tidal volume, and minute ventilation were recorded continuously. INTERVENTIONS: Ventricular fibrillation for 6 min without CPR, then mechanical chest compression for 10 min. RESULTS: During the first minute of chest compression, mean (+/- S.D.) minute ventilation was 11.2 +/- 5.9 l/min in the mechanically ventilated group and 4.5 +/- 2.8 l/min in the group without mechanical ventilation (P = 0.01). Minute ventilation gradually declined to 5.8 +/- 1.4 l/min and 1.7 +/- 1.6 l/min, respectively, during the last minute of chest compression (P < 0.0001). After 10 min of chest compression, mean arterial pH was significantly more acidemic in the group without mechanical ventilation (7.16 +/- 0.13 compared with 7.30 +/- 0.07 units) and PCO2 was higher (62 +/- 19 compared with 35 +/- 9 mmHg). Mixed venous PCO2 was also higher (76 +/- 15 compared with 61 +/- 8 mmHg). CONCLUSION: Standard chest compression alone produced measurable tidal volume and minute ventilation. However, after 10 min of chest compression following 6 min of untreated ventricular fibrillation, it failed to sustain pulmonary gas exchange as indicated by significantly greater arterial and mixed venous hypercarbic acidosis when compared with a group receiving mechanical ventilation.

Acid-Base Equilibrium

Components of the work of breathing and implications for monitoring ventilator-dependent patients.

OBJECTIVES: a) To discuss the components of the work of breathing using an established physiologic model (Campbell diagram); b) to describe the requirements of a monitor to measure work; and c) to discuss the implications and relevance for assessing the work of breathing of ventilator-dependent patients. DATA SOURCES: Relevant articles from the medical and physiologic literature are referenced, as well as the authors' experience. STUDY SELECTION: Identified (by authors) laboratory and clinical research establishing the need and physiologic importance for correctly measuring the work of breathing. DATA EXTRACTION: A physiologic model of the various components of the work of breathing is used in conjunction with data from published literature. SYNTHESIS: Diagrams of increasing complexity based on the Campbell diagram depict the physiologic elastic and resistive work of breathing for the lungs and chest wall under normal and abnormal conditions. Decreases in compliance and increases in airways resistance are associated with increases in elastic and resistive work, respectively. A modification of the Campbell diagram to include an additional area depicting the imposed work of the breathing apparatus is suggested; i.e., the additional resistive load imposed on the respiratory muscles by the endotracheal tube, breathing circuit, and the ventilator's demand-flow system during spontaneous breathing. Increases in physiologic and/or imposed work result in respiratory muscle loading, predisposing to increases in oxygen consumption and the development of fatigue and hypercapnia. Measuring work of breathing by integrating the area of the esophageal pressure-volume loop alone underestimates the work of breathing relative to the Campbell diagram and, therefore, should not be used. Because the site of pressure measurement and mode of ventilation influence measurements of the work of breathing as well as compliance, clinicians should be aware of these factors when interpreting measurements. Monitors that are used in clinical practice to assess the work of breathing should be able to measure pressure at the airway opening (between the Y-piece of the breathing circuit and the endotracheal tube), at the carinal end of the endotracheal tube, and in the esophagus (inference of intrapleural pressure); as well as measure flow rate and volume at the airway opening; and calculate the various components of the work of breathing based on the Campbell diagram. CONCLUSIONS: Accurate measurement of physiologic and imposed work performed by the patient are essential to assess the afterload on the respiratory muscles, diagnose specific work of breathing abnormalities, and monitor the effects of interventions to mitigate respiratory muscle loading. Work of breathing data are useful in formulating objective guidelines for setting the ventilator appropriately to optimize respiratory muscle loads, e.g., selecting an appropriate amount of pressure support ventilation to decrease the work of breathing to a specific level.

Airway Resistance

The composition of gas given by mouth-to-mouth ventilation during CPR.

STUDY OBJECTIVE: To compare the concentration of a rescuer's exhaled O2 and CO2 during mouth-to-mouth ventilation with or without chest compression. DESIGN: Prospective repeated measures study. Simulated one- and two-rescuer cardiopulmonary resuscitation (CPR) was performed as recommended by the American Heart Association. SETTING: University laboratory. PARTICIPANTS: Fifty-five healthcare professionals certified in basic and advanced cardiac life support volunteered as rescuers in this study. MEASUREMENTS AND RESULTS: Thirty-three volunteers performed one-rescuer CPR, and 22 volunteers performed two-rescuer CPR. Minute ventilation for both groups increased 50% to 130% during CPR (p < 0.05). During the performance of CPR, the concentration of exhaled O2 increased from 16.4 +/- 0.7% to 16.9 +/- 0.5% in the one-rescuer CPR group and from 16.5 +/- 0.9% to 17.8 +/- 0.6% in the two-rescuer CPR group (p < 0.05). The concentration of exhaled CO2 in the one-rescuer CPR group did not change significantly throughout the entire experiment, but decreased in the two-rescuer CPR group from a baseline measurement of 4.0 +/- 0.6% to 3.5 +/- 0.4% (p < 0.05). During CPR, the concentration of exhaled CO2 was 4.0 +/- 0.4% in the one-rescuer CPR group compared with 3.5 +/- 0.4% in the two-rescuer CPR group (p < 0.05). CONCLUSIONS: The gas given by mouth-to-mouth ventilation is a hypercarbic and hypoxic mixture compared with room air. Mouth-to-mouth ventilation is the only circumstance in which a hypercarbic and hypoxic gas is given as therapy. Further laboratory and clinical studies are necessary to determine the effect of mouth-to-mouth ventilation during CPR.

Carbon Dioxide