Detection of non-prescription heroin markers in urine with liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

The planned introduction of a prescription heroin program in Germany created a need for differentiation between non-prescription and prescribed diamorphine use. The following substances were chosen as markers of non-prescription heroin: acetylcodeine (AC); its metabolites codeine (C) and codeine 6-glucuronide (C6G); papaverine (P); and noscapine (N). Typical heroin markers diamorphine (DAM) and its metabolites monoacetylmorphine (MAM) and morphine (M) were also determined. The drugs were extracted from urine samples with solid-phase extraction (C18) using standard 200-mg columns and 96-well microplates (100 mg). The extracts were examined with liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (positive ionization) in two isocratic systems. Selected ion monitoring procedures were applied for protonated molecular masses and characteristic fragments of drugs involved. The limits of detection were in the range of 0.5-1 ng/mL urine. The occurrence of selected heroin markers was investigated in 25 urine samples collected from heroin abusers (road traffic offenders and overdosed patients). C6G was found in all samples, C in 24 samples, N in 22 samples, MAM in 16 samples, P in 14 samples, DAM in 12 samples, and AC in 4 samples. The appearance of these compounds in urine reflects their pharmacokinetic properties and the composition of non-prescription heroin.

Adult↗

Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity.

The applications of LC-API-MS in routine forensic toxicological casework were presented. This technique has been used for routine determination of several groups of drugs: opiate agonists (like morphine, codeine, dihydrocodeine and their glucuronides, methadone, buprenorphine) cocaine and its metabolites (benzoylecgonine and ecgonine methyl ester), amphetamine and other psychoactive phenethylamines, like MDMA, MDE or MDA, benzodiazepine derivatives (flunitrazepam and metabolites, triazolam, bromazepam), hallucinogens (LSD, psilocybin, psilocin) and olanzapine, A common solid-phase extraction procedure for all drugs (with exception of LSD) has been developed. Among two ionization sources, atmospheric pressure chemical ionization appeared more universal and assured generally higher sensitivity. Only in the case of very polar drugs (e.g. psilocin or psilocybin) electrospray ionization was more sensitive. LC-API-MS became a very powerful and flexible method for dedicated analyses of substances of forensic interest. The use of this technique for general, broad applicable screening depends on the establishing of interlaboratory database of standardized mass spectra.

Atmospheric Pressure↗

Analysis of underivatized amphetamines and related phenethylamines with high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

Amphetamine, methamphetamine, illicit designer phenethylamines (MDA, MDEA, MDMA, MBDB, and BDMPEA), and other phenethylamines (benzyl-1-phenylethylamine, cathinone, ephedrine, fenfluramine, norfenfluramine, phentermine, 1-phenylethylamine, phenylpropanolamine, and propylhexedrine) were extracted from serum using a solid-phase extraction procedure. The extracts were examined with high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS). The drugs were separated on ODS column in acetonitrile/50 mM ammonium formate buffer (pH 3.0) (25:75) as a mobile phase. Full-scan mass spectra of drugs examined by means of APCI with collision-induced dissociation showed protonated molecular ions and fragments typical for particular drugs. LC-APCI-MS allowed an unequivocal differentiation of all drugs involved. The quantitation was performed using selected ion monitoring of protonated molecular ions and fragments of drugs involved and their deuterated analogues. The limits of detection ranged from 1 to 5 microg/L serum, and the recoveries ranged from 58 to 96%. A linear response was observed for all drugs in the range from 5 to 500 microg/L. The method was applied for routine determination of amphetamine, MDMA, MDA, and MDEA in one run. Solid-phase extraction used assured simultaneous isolation of various groups of basic drugs of forensic interest (opiates, cocaines, phenethylamines, and benzodiazepines) from biofluids.

Amphetamines↗

Hyphenated liquid chromatographic techniques in forensic toxicology.

The prerequisite of applicability of hyphenated methods in forensic analysis is the achievement of a stage of "final maturity". In the field of liquid chromatography, HPLC coupled with diode array detection (DAD) seems to fulfill this criterion, whilst the combination with atmospheric pressure ionization mass spectrometry (HPLC-API-MS) is still in a development stage. HPLC-DAD is broadly used as identification tool in forensic and in emergency toxicology. Two main approaches were observed; development of retention index scales for intra-laboratory exchange of data and establishing of databases only for intra-laboratory use. Using these approaches, several databases were established for toxicological relevant substances (illicit and therapeutic drugs and their metabolites, environmental poisons etc.) in biological fluids. Also, complete HPLC-DAD identification systems are commercially available. Further possibility of progress depends on the on-line combination ("triple hyphenation") with other detection methods, preferably API-MS. HPLC-API-MS, both in electrospray (ESI) and atmospheric pressure chemical ionization (APCI) options, underwent dramatic development in the last decade and is reaching its final shape. The method was broadly applied for various groups of toxicologically relevant substances, a lot of them unaccessible for other techniques, including GC-MS. Particularly important was application of HPLC-API-MS for detection and quantitation of active, polar metabolites of various drugs and for analysis of macromolecules. APCI seems to be more useful for analysis of less polar compounds, whereas ESI is particularly valuable for determination of polar, large molecules (e.g., toxic peptides, polar metabolites etc.) Up to now, HPLC-API-MS has been mainly applied for dedicated analyses, but the introduction of APCI or ESI in systematic toxicological screening may be expected in the near future.

Chromatography, High Pressure Liquid↗

Monitoring of olanzapine in serum by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A selective assay of olanzapine with liquid chromatography atmospheric pressure chemical ionization (LC-APCI-MS, positive ions) is described. The drug and internal standard (ethyl derivative of olanzapine) were isolated from serum using a solid-phase extraction procedure (C18 cartridges). The separation was performed on ODS column in acetonitrile-50 mM ammonium formate buffer, pH 3.0 (25:75). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection (SIM) was applied with the following ions: m/z 313 and 256 for olanzapine and m/z 327 and 270 for the internal standard for quantitation. The limit of quantitation was 1 microg/l, the absolute recovery was above 80% at concentration level of 10 to 100 microg/l. The method tested linear in the range from 1 to 1000 microg/l and was applied for therapeutic monitoring of olanzapine in the serum of patients receiving (Zyprexa) and in one case of olanzapine overdose. Olanzapine in frozen serum samples and in frozen extracts was stable over at least four weeks. The examinations of urine extracts from patients receiving olanzapine revealed peaks of postulated metabolites (glucuronide and N-desmethylolanzapine).

Antipsychotic Agents↗

Poor reproducibility of in-source collisional atmospheric pressure ionization mass spectra of toxicologically relevant drugs.

The purpose of the study was to examine the intra- and interlaboratory reproducibility of mass spectra obtained with liquid chromatography-atmospheric pressure ionization mass spectrometry (LC--API-MS) both in electrospray (ESI) and atmospheric pressure chemical ionization (APCI) modes. Toxicologically relevant drugs of different polarity were selected as test substances: morphine-6-glucuronide, 6-monoacetylmorphine, codeine, lysergic acid diethylamide, methylenedioxymethamphetamine. The study was performed in two laboratories using identical instruments and in one using a slightly different instrument. Basic instrument settings and mobile phase were identical in all laboratories. Mass spectra of drugs were taken at four collision energy voltages and using mobile phase of different composition (four concentration levels of acetonitrile and of ammonium formate buffer). The experiments demonstrated that mass spectra of given drugs, obtained in identical conditions with identical instruments, may show very different degrees of fragmentation. Mass spectra obtained with different instruments differed profoundly not only in the degree of fragmentation, but also different fragments and adducts were observed. Short-term intralaboratory reproducibility of mass spectra was satisfactory. On the other hand, the long-term experiments showed different degrees of fragmentation of APCI-generated mass spectra at nominally identical fragmentation energy. The changes in the composition of the mobile phase (concentration of organic modifier or buffer molarity) did not affect the reproducibility of fragmentation to any relevant degree. The study showed that the interlaboratory exchange and use of mass spectrum library, generated by single-quadrupole (LC--API-MS instruments, is hardly feasible at the moment, even under very carefully standardized conditions.

Atmospheric Pressure↗

Determination of flunitrazepam and its metabolites in blood by high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A selective assay of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DF) and 3-hydroxyflunitrazepam (3-OHF) with liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS, positive ions) is described. The drugs were isolated from serum, blood or urine using a solid-phase extraction procedure previously applied to various drugs of abuse. F-d3 and 7-AF-d3 were used as internal standards. The drugs were separated on ODS column in acetonitrile-50 mM ammonium formate buffer, pH 3.0 (45:55, v/v). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection was applied with following ions: m/z 284 (7-AF and F), 287 (7-AF-d3 and F-d3), 314 (F), 300 (N-DF and 3-OHF), 317 (F-d3), 330 (3-OHF). The limits of detection were: 0.2 microg/l for F and 7-AF, 1 microg/l for N-DF and 3-OHF. The method was linear in the range 1-500 microg/l, the recoveries ranged from 92 to 99%. The method was applied for determination of F and metabolites in clinical and forensic samples. LC-APCI-MS seems to be a method of choice for these compounds.

Anti-Anxiety Agents↗

Honey with Psilocybe mushrooms: a revival of a very old preparation on the drug market?

In 1996 samples of suspicious honey preparations were confiscated at the Dutch-German border. The labels on the 50 ml jars indicated that the honey contained Stropharia cubensis (better known as Psilocybe cubensis). The jars were filled with honey with a ca. 1 cm layer of fine particles on the top. The particles were collected and subjected to microscopic and chemical analysis. By microscopy mushroom tissue (plectenchym) and spores typical for the genus Psilocybe were identified in all samples. The HPLC analysis with atmospheric pressure mass spectrometry and diode array detection revealed psilocine but psilocybine was not found. The quantitative analysis was very difficult due to the matrix problems. A search showed that the honey with Psilocybe can be purchased in Dutch coffee shops without any limitations although psilocine and psilocybine belong to listed substances according to Dutch law.

Chromatography, High Pressure Liquid↗

Determination of morphine and its 3- and 6-glucuronides, codeine, codeine-glucuronide and 6-monoacetylmorphine in body fluids by liquid chromatography atmospheric pressure chemical ionization mass spectrometry.

A selective assay of morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G), morphine, codeine, codeine-6-glucuronide (C6G) and 6-monoacetylmorphine (6-MAM) based on liquid chromatography atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS) is described. The drugs were extracted from serum, autopsy blood, urine, cerebrospinal fluid or vitreous humor using C18 solid-phase extraction cartridges and subjected to LC-APCI-MS analysis. The separation was performed on an ODS column in acetonitrile-50 mM ammonium formate buffer, pH 3.0 (5:95), using a flow-rate gradient from 0.6 to 1.1 ml/min (total analysis time was 17 min). The quantitative analysis was done using deuterated analogues of each compound. Selected-ion monitoring detection was applied: m/z 286 (for morphine, M3G-aglycone and M6G-aglycone), 289 (for morphine-d3, M3G-d3-aglycone and M6G-d3-aglycone), 300 (for codeine and C6G-aglycone), 303 (for C6G-d3-aglycone), 306 (for codeine-d6), 328 (for 6-MAM), 334 (for 6-MAM-d6), 462 (for M3G and M6G), 465 (for M3G-d3 and M6G-d3), 476 (for C6G) and 479 (for C6G-d3). The limits of quantitation were: 1 microg/l for morphine, 2 microg/l for 6-MAM, 5 microg/l for M3G, M6G and codeine and 200 microg/I for C6G. The recovery ranged from 85 to 98% for each analyte. The method appeared very selective and may be used for the routine determination of opiates in body fluids of heroin abusers and patients treated with opiates.

Analgesics, Opioid↗

Morphine, morphine-3-glucuronide, morphine-6-glucuronide, and 6-monoacetylmorphine determined by means of atmospheric pressure chemical ionization-mass spectrometry-liquid chromatography in body fluids of heroin victims.

Morphine, morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G), and 6-monoacetylmorphine (6-MAM) were isolated from body fluids using solid-phase extraction and determined by means of atmospheric pressure chemical ionization-mass spectrometry-liquid chromatography (APCI-LC-MS) in selected ion monitoring mode. The following ions were monitored: m/z 286 for morphine; m/z 286 and 462 for M3G and M6G; m/z 211, 268, and 328 for 6-MAM; and m/z 289 for morphine-d3 (internal standard). The recoveries ranged from 82 to 89% The limits of detection were as follows: 0.1 ng/mL (morphine), 0.5 ng/mL (6-MAM), and 1 ng/mL (M3G and M6G). The analytes were determined in samples taken from 21 heroin-overdose victims. Twenty-one blood samples, 11 cerebrospinal fluid (CSF) samples, 12 vitreous humor (VH) samples, and 6 urine samples were investigated. Blood concentrations (ng/mL) of morphine ranged from 8 to 1539, of M3G from 111 to 941, of M6G from 32 to 332, and of 6-MAM from 0 to 73. The levels of morphine were correlated with glucuronide values and with 6-MAM. The concentrations of morphine, M3G, and M6G in CSF were, as a rule, lower than in blood and lower in VH than in CSF. The concentrations of morphine and molar ratios of M6G-morphine in blood and CSF were correlated. Low ratios of M3G-morphine and M6G-morphine in blood of heroin-overdose victims indicated short survival time after drug intake.

Adolescent↗

Applicability of various brands of mixed-phase extraction columns for opiate extraction from blood and serum.

Four commercially available types of mixed-phase solid-phase extraction (SPE) columns (Bond Elut Certify, Isolute Confirm HCX, Chromabond Drug and Bakerbond Narc-2) were examined in order to compare the extraction efficiencies and chromatographic purity of extracts. The absolute recovery of morphine, 6-monoacetylmorphine and codeine was examined in blood and serum (ten samples each at two concentration levels), using SPE columns of the same batch. GC-MS (ion trap) and HPLC with amperometric detection were used for quantitation. A distinct variability in extraction recovery was observed among the same batches of all brands of SPE columns. All extracts were chromatographically pure and no interfering peaks were observed, neither in GC-MS nor in HPLC examinations, but in some extracts large peaks of plasticizers were identified. The measurements of flow velocities of the same samples of blood or serum through the SPE columns of the same batch showed very large variability of random character. The morphometric analysis of particles was performed for two batches of each sort of SPE columns by means of an image analysing system. Symmetrical distribution of particle size was observed only in Chromabond MN Drug packing, while in other cartridges large fractions of fine particles and nonhomogenous distribution were found. Only in one case the morphometric findings were pretty concordant with the data available from the manufacturer; in two cases, observed data varied considerably from that expected, and in one case no information was available at all. The study showed generally that there was room for improvement in the quality of mixed-phase SPE columns.

Analgesics, Opioid↗

Internally concealed cocaine: analytical and diagnostic aspects.

Thirty persons arrested at Frankfurt airport for smuggling internally concealed cocaine in 1993/1994 were investigated. An X-ray examination (in all 30 cases), immunochemical examination of urine (in 27 cases) and of saliva (in 20 cases) was performed in parallel. An X-ray examination gave positive results in all examined persons. EMIT cocaine metabolite assay (cut off 300 ng benzoylecgonine (BE)/mL) was positive in eight urine samples. After reducing the cut off to 150 ng BE/mL urine, eleven samples were classified as positive. The results were confirmed by means of chromatographic determinations. These findings showed limited role of immunological examination of urine as a screening test in suspected smuggling of internally concealed drugs. All saliva samples showed negative immunochemical results. The number of concealed containers ranged from 44 to 135 per person. The amount of cocaine hydrochloride found in particular cases ranged from 242 to 1050 g net weight, divided into containers weighing from 5.7 to 13.8 g. Drug packages were obviously machine-made. The packages smuggled by a particular person were uniform. However, a distinct interpersonal variability in drug packages was observed, in regard to the number of protective layers (4-7), size, weight, and cocaine purity. This may be helpful for the identification of production site. The leaching of cocaine from selected containers was investigated in a stirring bath and was independent of the conditions applied.

Adult↗

Determination of phenylisothiocyanate derivatives of amphetamine and its analogues in biological fluids by HPLC-APCI-MS or DAD.

Amphetamine (A), methamphetamine (MA), methylene dioxyamphetamine (MDA), methylenedioxyethylamphelamine (MDE), and methylenedioxymethamphetamine (MDMA), as well as eight other sympathomimetic amines (benzyl-1-phenylethylamine, ephedrine, fenfluramine, norfenfluramine, phentermine, phenylethylamine, phenylpropanolamine, and propylhexedrine), were extracted from serum or urine with ether, derivatized with phenylisothiocyanate, and subjected to high-performance liquid chromatographic (HPLC) examination in isocratic mode. Two detection arts were applied: atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) and UV-spectrometry as diode array detection (DAD) or single wavelength at 250 nm. The derivatives were well-separated and showed good chromatographic behavior. Full-scan mass spectra of drugs examined by means of APCI with collision induced dissociation (APCID) contained protonated molecular ions (M+H)+ and fragments typical for particular drugs. APCID-liquid chromatography-mass spectrometry (LC-MS) appeared very selective for differentiation of all drugs involved. The quantitation with APCID was performed using selected ion monitoring (SIM) of (M+H)+ ions and selected fragments of drugs involved and their deuterated analogues. The limits of detection ranged from 0.001 mg/L (MA, MDMA, and MDE) to 0.005 mg/L (A and MDA). In HPLC-DAD, the spectra of MDMA and MDE were practically identical with maxima of 236-240 nm. Other amphetamines showed slightly different spectra with maxima of 245-250 nm. The limits of detection in UV detection amounted to 0.01-0.03 mg/L (single wavelength detector at 250 nm) or 0.05-0.1 mg/L (DAD).

Amphetamines↗