PubMed Health⌕ Search

Biomedical subjects

M J Budoff

Publications and source records attributed to M J Budoff.

At least 37 records · Page 2Linked to original sources

Effects of scanning and reconstruction parameters on image quality in electron-beam CT angiography: coronary artery phantom study.

RATIONALE AND OBJECTIVES: This study compared the image quality obtained with different scanning and reconstruction parameters for electron-beam computed tomographic (CT) angiography and sought optimal methods for visualizing the coronary artery lumen. MATERIALS AND METHODS: Electron-beam CT angiography with contrast material enhancement was used to image 35 branches of fresh postmortem swine coronary arteries. Different collimation widths, fields of view (FOVs), reconstruction kernels, and algorithms were employed to reconstruct the acquired raw data into CT angiographic images. Image quality was compared and analyzed. RESULTS: The contrast-to-noise ratios (C/Ns) for 1.5-, 2-, and 3-mm section thickness were 28.4 +/- 15.2, 31.9 +/- 9.3, and 33.8 +/- 14.5, respectively (P < .05). The lengths of visualized coronary artery lumina were significantly longer for 1.5-mm scanning (71.6 mm +/- 4.3) than for 2-mm (58.3 mm +/- 5.5) and 3-mm scanning (59.0 mm +/- 8.0) (P < .01). The C/Ns for 12.7-, 18.0-, and 26.0-cm FOV reconstruction were 32.8 +/- 9.9, 28.9 +/- 8.2, and 27.1 +/- 8.2, respectively (not significant), and the visualized luminal lengths were 76.1 mm +/- 12.5, 71.7 mm +/- 14.6, and 65.4 mm +/- 13.1, respectively (not significant). The highest C/N (48.2 +/- 13.3) was achieved with smooth kernels and a cone-beam algorithm, and the lowest (14.7 +/- 3.4) with very sharp kernels and a normal algorithm. Cone-beam algorithm images had significantly higher C/Ns than did normal algorithm images (P < .001), and they demonstrated longer coronary artery lumina (P < .01). CONCLUSION: Collimation width, FOV, reconstruction kernels, and algorithms are important in the processing of high-quality electron-beam coronary angiograms. A 1.5-mm collimation width, 12.7-cm FOV, cone-beam reconstruction algorithm, and very sharp kernels should help in obtaining the best image quality and depicting the longest segments of coronary artery lumen.

Algorithms↗

Preview method for electron-beam CT scanning of the coronary arteries.

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate a method that uses electron-beam computed tomography to obtain the most appropriate starting level for complete imaging of the coronary tree and to compare it with the existing method. A second aim was to evaluate the spatial location of the coronary arteries relative to different anatomic cardiac and chest landmarks. MATERIALS AND METHODS: Two hundred forty consecutive patients were randomly assigned to imaging with either a six-level preview (new) method or the traditional preview method. The accuracy of each preview method to encompass the coronary anatomy was compared. RESULTS: All coronary arteries were included in 3-mm scans obtained starting three levels above the origin of the left main coronary artery. The left anterior descending coronary artery extended 3-9 mm above the left main artery in 33 patients (14%). The coronary arteries were encompassed by scans depicting 72-105 mm; thus, with 3-mm sections, up to 35 scans are necessary to cover the entire coronary tree. No stable relationship between the coronary arteries and the pulmonary artery or carina could be found. CONCLUSION: The six-level preview method that identifies the left main coronary artery and begins 9 mm above this level is the most accurate method for depicting the coronary anatomy. No anatomic landmarks in the heart or chest can be used reliably to identify the position of the coronary arteries in individual patients.

Coronary Angiography↗

A simple single slice method for measurement of left and right ventricular enlargement by electron beam tomography.

RATIONALE AND OBJECTIVE: We devised to test the feasibility of measuring the left and right ventricular sizes by non-contrast electron beam tomographic images. METHODS: Ventricular sizes consist of the sum of the intracavitary cavity and myocardial mass for each ventricle. A total of 50-image studies from subjects undergoing contrast-enhanced studies were used to develop the measurement methodology. About 20 contrast studies were used to test the measure. The methodology was then prospectively tested on 75 patients with non-contrast studies to estimate the intra-observer, inter-observer and inter-study reproducibility. RESULTS: Multiple linear regression analysis was completed and the correct regression formulas to calculate ventricular volumes were acquired by using the area and span from the contrast studies. There was excellent correlation between the estimate of LV (r > 0.97, p < 0.001) and RV (r > 0.93, p < 0.001) sizes between measured and calculated (contrast, single slice) left and right ventricular volumes. The intra-observer, inter-observer and inter-study reproducibility demonstrated excellent results with < 7% difference in absolute values and a high correlation (r > 0.89, p < 0.001). CONCLUSION: We conclude that the left and right ventricular sizes can be accurately estimated from a single mid-ventricular slice on non-contrast electron beam tomographic images.

Case-Control Studies↗

Safety of EBCT contrast injection studies in severe pulmonary hypertension.

PURPOSE: There is considerable literature published on noninvasive contrast-enhanced techniques to diagnose pulmonary vascular abnormalities, however little data exists on the safety of contrast injections in patients with elevated pulmonary arterial pressures. We studied the safety of contrast-enhanced electron beam computed tomography (EBCT) in 29 patients with severe pulmonary hypertension. The mean dose of intravenous contrast used was 124 +/- 39 cc. MATERIALS AND METHODS: Subjects underwent EBCT using contrast injected at a rate of 2-4 ml/s. All patients were watched closely for at least 15 min post-procedure prior to being released. Patients had Doppler echocardiograms to estimate pulmonary artery pressure. Right heart catheterization data was collected for patients in which echocardiographic data was unavailable. RESULTS: A total of 29 patients with pulmonary arterial hypertension were studied. There were 17 patients with primary pulmonary hypertension (PPH), and 12 patients with secondary forms of pulmonary hypertension. None of the patients developed complications from their study. CONCLUSION: There is a paucity of data on the safety of contrast injections in patients with severely elevated pulmonary arterial pressures. Contrast-enhanced EBCT was well-tolerated in our diverse series of patients with severely elevated pulmonary arterial pressures. Clinicians concerned about invasive pulmonary angiography should consider contrast-enhanced EBCT as a safe alternative to angiography.

Adult↗

Accurate measures of left ventricular ejection fraction using electron beam tomography: a comparison with radionuclide angiography, and cine angiography.

BACKGROUND: Quantitative determination of ejection fraction is predicated on precise measurement of end-diastolic and end-systolic volumes of the left ventricle. Contrast enhanced electron beam tomography (EBT), with excellent temporal and spatial resolution, has the potential for highly accurate measures of ejection fraction. METHODS: EBT protocol used a short axis scan of the left ventricle (8-12 levels, apex to base) during infusion of iodinated contrast. To assess the accuracy of the measured left ventricular ejection fraction (LVEF), we compared EBT with first-pass radionuclide angiography (RNA) and cine angiography (CINE). RESULTS: A total of 41 patients (26 men and 15 women) underwent all three tests within 1 week. Resting ejection fraction using each modality was assessed in a linear regression model to assess inter-test correlation with the other two modalities. Correlation between CINE and EBT was high (r = 0.90, intercept 4.67, p < 0.001). Similarly, correlation of CINE and RNA (r = 0.87, intercept -5.48, p < 0.001) and between EBT and RNA (r = 0.87, intercept -4.6, p < 0.001) were high. In a subset of those patients with LVEF < or = 40%, correlation was consistently high between EBT and CINE. However, correlations were poor for the comparisons between RNA and CINE (r = 0.40), and between the RNA and EBT (r = 0.47). The mean differences of measured ejection fractions between each of the imaging modality were small. However, there was only modest agreement between each of the comparisons as measured using 95% confidence interval (CI) on Bland-Altman plots. CONCLUSION: These data indicate that the LVEF results are comparable among EBT, RNA, and CINE and can be used interchangeably to assess ventricular function for LVEF > 40%. For LVEF < or = 40%, we demonstrated some disparate results between cine angiography and RNA and between EBT and RNA, indicating that CINE or EBT may provide more accurate assessment.

Cineangiography↗

Evaluation of fluid collection in the pericardial sinuses and recesses: noncontrast-enhanced electron beam tomography.

RATIONALE AND OBJECTIVES: To evaluate the attenuation, size, and volume of the pericardial sinuses and recesses by using electrocardiographically triggered, noncontrast-enhanced electron beam tomography (EBT) and to consider its relation with sex, age, and heart volume. METHODS: Findings in 213 consecutive patients without known pericardial disease were studied. The patients underwent EBT scanning of the heart to evaluate coronary artery calcification. Incremental electrocardiographically triggered noncontrast images were obtained with a 100-ms exposure time and a 3-mm slice thickness. The appearance, density, and volume of the pericardial sinuses and recesses were calculated. RESULTS: Among the 213 patients, 97.2% had at least one of the sinuses or recesses visible on EBT. The sinuses or recesses were seen with the following frequency: transverse sinus (93.9%), oblique sinus (71.8%), and superior aortic recess (51.2%). The mean attenuation and volume were 9.9 +/- 7.3 Hounsfield units (HU), 12.6 +/- 8.1 HU, and 12.6 +/- 8.7 HU, and 1.9 +/- 1.3 mL, 1.3 +/- 1.0 mL, and 0.8 +/- 0.8 mL, respectively. The total volume of the pericardial sinuses (3.3 +/- 2.2 mL) had no significant relation with the total heart volume. CONCLUSIONS: Pericardial sinuses and recesses were frequently and well depicted on noncontrast EBT images. In patients without obvious pericardial effusion, physiological fluid collections were observed in the transverse and oblique sinuses or other recesses. Location, attenuation, and volume were helpful in the differentiation of normal pericardial sinuses from pericardial effusions and mediastinal lymph nodes.

Adult↗

Evaluation of electron beam tomographic coronary arteriography with three-dimensional reconstruction in healthy subjects.

In this study, the authors evaluated the performance characteristics of contrast-enhanced electron-beam tomography (EBT) with three-dimensional reconstruction in defining the coronary artery lumen in healthy subjects. Thirty patients with normal coronary angiograms by selective coronary arteriography (SCA) underwent contrast-enhanced EBT examination. Measured parameters included degree of luminal enhancement, intravascular contrast-to-noise ratio (CNR), and diameter and length of visualized lumen. Ventricular cavity, aortic blood pool, and coronary artery attenuation were found to be significantly different before and after intravenous injection of contrast material (p < 0.001). CNR decreased from proximal to distal segments within each vessel (p < 0.001), with a peak of 11.2 +/- 2.3 occurring in the proximal left anterior descending coronary artery (LAD) to a low of 4.8 +/- 2.0 in the distal left circumflex (LCX). Luminal diameters visualized by EBT had no significant difference with that of SCA (p > 0.05). Therefore, EBT angiography with three-dimensional reconstruction allows for noninvasive coronary arteriography revealing long segments of the major coronary arteries in normal subjects.

Adult↗

Detection and analysis of intracoronary artery stent after PTCA using contrast-enhanced three-dimensional electron beam tomography.

We evaluated several three-dimensional methods of contrast-enhanced electron beam tomography (EBT) for evaluation of intracoronary stent characteristics after percutaneous transluminal coronary angioplasty (PTCA). Twenty-six patients who had undergone PTCA and stenting (31 stents) were investigated by using contrast-enhanced, electrocardiographically (ECG) triggered EBT scanning. EBT results were compared with conventional selective coronary arteriography (SCA). Overall, 27 intracoronary stents had been identified on EBT images (87.1%), while 4 stents could not be evaluated because of impaired image quality. EBT correctly identified the only case in which there was a residual stenosis at the distal portion of the stent. As compared with SCA results, EBT showed an over-estimation of intracoronary stent diameter (p < 0.001) and accurate measurement on the visualized length of the stents (p > 0.05). Fifty Hu, 100 Hu and 150 Hu were used as the observed window levels on three-dimensional (3-D) images; the accuracy for stent assessment increased with ascending window levels. EBT can reliably characterize coronary artery stents and may become a useful non-invasiveive method for patency evaluation of stented coronary segments after PTCA.

Adult↗

Electron beam tomography with three-dimensional reconstruction in the diagnosis of aortic diseases.

BACKGROUND: This study was performed to evaluate the protocols of electron beam tomographic angiography and three-dimensional reconstruction for assessing the diagnostic value of aortic diseases. METHODS EXPERIMENTAL DESIGN: Retrospective and comparative study. SETTINGS: University hospital. PATIENTS: Between 1996 and 1998, 189 cases who underwent electron beam tomographic angiography and diagnosed with aortic diseases were analyzed retrospectively. The results were compared with surgical and pathological findings in 68 cases. Electron beam tomographic angiography was used single-slice-scanning with ECG-triggering for screening of the thoracic aorta, continuous-volume-scanning, permitted by continuous X-ray exposure with table incremention, was performed for the abdominal aorta scanning without ECG-triggering. Three-dimensional reconstructions were performed with shaded-surface display, multiplanar reformatting and/or maximum intensity projection methods. RESULTS: Electron beam tomography angiography with ECG-triggered sections of single-slice-scanning improved the image quality of the ascending aorta without motion artifacts. Continuous-volume-scanning was suitable for screening of the abdominal aorta because of minimizing exposure time (10-14 sec) and saving contrast media (total contrast material of 45.5+/-6.6 ml was needed). One hundred eighty-nine cases were diagnosed with aortic dissection (97 cases), aortic aneurysm (26 cases), pseudoaneurysm (8 cases), Marfan's syndrome (39 cases), Takayasu's arteritis (5 cases) and congenital aortic malformations (14 cases). Electron beam tomography results were compared with the findings of surgery (as gold standard) in 68 cases, the diagnostic accuracy was 97% (2 cases with aortic aneurysm were erroneously diagnosed with pseudoaneurysm). CONCLUSIONS: Electrocardiographically triggered, contrast-enhanced electron beam tomography is feasible for the diagnosis of all kinds of aortic diseases, with excellent three-dimensional images competitive in quality with conventional selective aortic angiography or digital subtraction angiography.

Adolescent↗

Effect of exercise on left and right ventricular ejection fraction and wall motion.

OBJECTIVE: We evaluated the diagnostic value of response of left and right ventricular ejection fraction and wall motion to exercise using electron beam computed tomography. METHODS AND RESULTS: We attempted to determine the value of exercise electron beam computed tomography for detecting coronary artery disease, including evaluation of the right ventricular ejection fraction and wall motion abnormalities. A study of 35 patients undergoing electron beam tomography exercise cine studies and coronary artery angiography for the evaluation of chest pain was performed. Of the 18 patients with significant coronary disease (> or = 50% luminal diameter stenosis in at least one coronary artery), 17 (94%) had failure to increase global left ventricular ejection fraction with exercise. Fourteen of 18 (78%) developed a wall motion abnormality during peak exercise, and eight (44%) developed a regional right ventricular wall motion abnormality during peak exercise. Of the 17 patients without obstructive disease, 14 (82%) had a increase in ejection fraction > or = 5% and none had an abnormal response in left ventricular wall motion during peak exercise (specificity = 100%). The change in right ventricular ejection fraction with exercise was not a significant predictor of obstructive coronary disease in this study (P=NS). Using different criteria during stress to predict coronary disease, the accuracy was 89% (31/35) using an increase of <5% in ejection fraction, 89% (31/35) using the development of a new or worsened wall motion abnormality, and 91% (32/35) using both left ventricular criteria. CONCLUSION: Our study suggests that exercise electron beam computed tomography appears to be a useful tool for the detection of coronary disease. A increase of <5% in ejection fraction and abnormal left ventricular response to exercise were important predictors, while the exercise induced changes of right ventricular ejection fraction was not a significant predictor of obstructive disease. Both left and right ventricular wall motion abnormalities are useful and important parameters in identifying patients with obstructive disease from those with normal coronary arteries.

Adult↗

Coronary calcium does not accurately predict near-term future coronary events in high-risk adults.

BACKGROUND: Prognostic risk models have had limited success in predicting coronary events in subjects with multiple risk factors. We and others have proposed an alternative approach using radiographically detectable coronary calcium. We evaluated and compared the predictive value of these 2 approaches for determining coronary event risk in asymptomatic adults with multiple coronary risk factors. In addition, we assessed the predictive value of a risk model that included calcium score and cardiac risk-factor data. METHODS AND RESULTS: We recruited 1196 asymptomatic high-coronary-risk subjects who then underwent risk-factor assessment and cardiac electron-beam CT (EBCT) scanning and were followed up for 41 months with a 99% success rate. We applied the Framingham model and our data-derived risk model to determine the 3-year likelihood of a coronary event. The mean age of our cohort was 66 years, and mean 3-year Framingham risk was 3.3+/-3.6%. Sixty-eight percent (818 subjects) had detectable coronary calcium. There were 17 coronary deaths (1.4%) and 29 nonfatal infarctions (2. 4%). The receiver operating characteristic (ROC) curve areas calculated from the Framingham model, our data-derived risk model, and the calcium score were 0.69+/-0.05, 0.68+/-0.05, and 0.64+/-0.05, respectively (P=NS). When calcium score was included as a variable in the data-derived model, the ROC area did not change significantly (0.68+/-0.05 to 0.71+/-0.04; P=NS). CONCLUSIONS: Neither risk-factor assessment nor EBCT calcium is an accurate event predictor in high-risk asymptomatic adults. EBCT calcium score does not add significant incremental information to risk factors, and its use in clinical screening is not justified at this time.

Aged↗

Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography.

Coronary angiography remains the diagnostic standard for establishing the presence, site, and severity of coronary artery disease (CAD). Electron beam computed tomography (EBCT), with its 3-dimensional capabilities, is an emerging technology with the potential for obtaining essentially noninvasive coronary arteriograms. The purpose of this study was to (1) test the accuracy of intravenous coronary arteriography using the EBCT to conventional coronary arteriographic images; (2) establish the inter-reader variability of this procedure; (3) determine the limitations due to location within the coronary tree; and (4) identify factors that contributed to improved image quality of the 3-dimensional EBCT angiograms. Fifty-two patients underwent both EBCT angiography and coronary angiography within 2 weeks. The coronary angiogram and the EBCT 3-dimensional images were analyzed by 2 observers blinded to the results of the other techniques. EBCT correctly identified 43 of 55 significantly stenosed arteries (sensitivity 78%), and correctly identified 118 of 130 of the nonobstructed arteries, yielding a specificity of 91% (p <0.001, chi-square analysis). The overall accuracy for EBCT angiography was 87%. Significantly more left main and anterior descending coronary arteries were adequately visualized than the circumflex and right coronary vessels (p = 0.003). Overall, 23 of 208 (11%) major epicardial vessels were noninterpretable by the blinded EBCT readers, primarily due to motion artifacts caused by cardiac and respiratory motion and poor electrocardiographic gating. The inter-reader variability was similar to that of angiography, and its high accuracy makes this a clinically useful test. This study demonstrates, by using intravenous contrast enhancement, that EBCT can clearly depict the coronary artery anatomy and can permit identification of coronary artery stenosis.

Contrast Media↗

Electron beam computed tomography: screening for coronary artery disease.

The need to detect coronary atherosclerosis early in its course has been well recognized by clinicians and epidemiologists for decades. The ability to identify populations with a greater prevalence of coronary disease prior to manifestation of illness would greatly reduce cardiac morbidity and mortality. Electron beam computed tomography (EBCT) uniquely combines the characteristics of speed and excellent density resolution that have led to a rebirth of interest in detecting coronary calcium as a means of screening asymptomatic populations for coronary atherosclerosis. Electron beam computed tomography is noninvasive and widely applicable. It can both detect and quantitate the presence of coronary atherosclerosis. A positive test has diagnostic and prognostic significance, predicting future cardiac events and the extent of atherosclerosis, including the probability of obstructive coronary artery disease (CAD). Multiple studies demonstrate a 6- to 35-fold increased risk of developing a cardiac event with elevated calcium scores. A negative test is highly predictive for excluding obstructive CAD. The cost ranges from $300 to $400, similar to that of an exercise treadmill test. Moreover, scanning for coronary calcium does not require injection of contrast medium, requiring no patient preparation or exercise; therefore, a CT technician can perform the study without supervision. The entire procedure takes < 10 min to perform. These features make EBCT a potential screening test for occult CAD in symptomatic and asymptomatic persons.

Algorithms↗

Simple single-section method for measurement of left and right atrial volumes with electron-beam CT.

RATIONALE AND OBJECTIVES: The authors estimated left and right atrial volumes by using a simple method of measurement with nonenhanced electron-beam computed tomography (CT). MATERIALS AND METHODS: One hundred sixty-four contrast material-enhanced electron-beam CT studies were divided into two groups. Group 1, which included 104 studies, was used to develop the measurement method (i.e., the formulas) for measuring left and right atrial volumes from a nonenhanced study. Group 2 consisted of 60 studies on which the validity of the method was tested. Measurement of left and right atrial volumes was performed on all section levels by tracing the respective atrial borders for each section, then multiplying the area by section thickness and summing the resultant volumes. RESULTS: Calculated left and right atrial volumes were derived by using the biggest atrial area and cephalic-caudal span. The span was equal to section thickness times the number of sections in which the atria were present. Linear regression analysis formulas were acquired with the biggest atrial area and cephalic-caudal span. Left and right atrial calculated volumes were obtained with these formulas and demonstrated a significant good relation (r > .95, P < .001) and a difference of less than 11% (P < .05) in absolute values between measured and calculated volumes. Intraobserver, interobserver, and interstudy reproducibility were excellent, with less than 10% difference in absolute values. CONCLUSION: Left and right atrial volumes can be accurately estimated from a single midventricular section by using nonenhanced electron-beam CT.

Anatomy, Cross-Sectional↗

Comparison of exercise electron beam computed tomography and sestamibi in the evaluation of coronary artery disease.

This blinded, single center study prospectively compares exercise electron beam computed tomography (EBCT) with stress technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) in 33 patients undergoing coronary angiography for evaluation of chest pain. Patients undergoing routine cardiac catheterization for the diagnosis of chest pain were imaged at rest using EBCT. Patients exercised on a semi-supine ergometer, and exercise EBCT was immediately followed by injection of Tc-99m sestamibi for assessment of myocardial ischemia. At peak exercise, Tc-99m SPECT, followed immediately by nonionic contrast material, was injected intravenously to directly compare these 2 imaging techniques. Patients were reimaged with Tc-99m SPECT at rest 24 to 48 hours after stress. Exercise EBCT, which was analyzed using a global ejection fraction measure, had a sensitivity of 81% and a specificity of 76%, compared with angiography. Using the development of a new regional wall motion abnormality as evidence of obstructive coronary artery disease (CAD), EBCT yielded a specificity of 100% and a sensitivity of 88%. Reversible perfusion defects identified by SPECT, as evidence of obstructive CAD, revealed a sensitivity of 75% and a specificity of 71%. The specificity of regional wall motion analysis by EBCT was significantly better than SPECT (p <0.01) in this population. This study demonstrates regional wall motion assessed by EBCT to be as sensitive and more specific than SPECT myocardial perfusion imaging in identifying obstructive CAD as defined by angiography.

Aged↗

Usefulness of electron beam computed tomography scanning for distinguishing ischemic from nonischemic cardiomyopathy.

OBJECTIVES: This study was undertaken to evaluate the ability of electron beam computed tomography (EBCT) to distinguish ischemic from nonischemic causes of cardiomyopathy by evaluating heart failure patients for coronary calcification (CC). BACKGROUND: The etiology of heart failure, whether coronary-induced or nonischemic, may be difficult to discern clinically. Differentiation of ischemic from nonischemic etiology is clinically important for both therapeutic and prognostic implications. With its ability to noninvasively discern and quantitate coronary artery calcification, EBCT correlates well with angiographic stenosis and thus may be useful in distinguishing ischemic and nonischemic cardiomyopathies. METHODS: One hundred and twenty-five patients with cardiomyopathy (ejection fraction <0.40) and known coronary anatomy underwent EBCT coronary scanning to evaluate for CCs within 3 months of coronary angiography. RESULTS: Of the 72 patients who were found to have ischemic cardiomyopathy, 71 patients had CC by EBCT (sensitivity 99%, p < 0.001), mean score 798+/-899. In comparison, among the 53 patients without significant coronary artery disease (CAD) (nonischemic cardiomyopathy), the mean score was significantly lower (17+/-51; p < 0.0001), and 44 patients had a CC score of 0 (no CC present). The specificity of EBCT to exclude CAD in patients with cardiomyopathy was 83%, using a threshold CC score of 0, and 92% for scores <80 (p < 0.001). Overall accuracy for determining the etiology of cardiomyopathy (differentiating ischemic from nonischemic) was 92% for this technique. CONCLUSIONS: This prospective, blinded study indicates that EBCT detected CC accurately and can noninvasively distinguish between cardiomyopathy because of CAD and nonischemic causes of left ventricular dysfunction.

Adult↗

Ultrafast computed tomography as a diagnostic modality in the detection of coronary artery disease: a multicenter study.

BACKGROUND: Ultrafast computed tomography (CT), by acquiring images of the proximal coronary arteries, detects coronary calcifications and has been demonstrated to be highly sensitive for the detection of coronary artery disease in many small studies. The aim of this study was to determine the relationship between ultrafast CT scanning and coronary angiography in a large number of symptomatic patients. METHODS AND RESULTS: The study population consisted of 710 patients from six participating centers. A multivariate logistic regression model was used to evaluate the individual contributions of age, number of calcified vessels, and the calcium score for the probability of angiographically significant disease. Of the 710 patients enrolled, 427 patients had significant angiographic disease, and coronary calcification was detected in 404, yielding a sensitivity of 95%. Of the 23 patients without calcifications, 19 (83%) had single-vessel disease at angiography. Of the 283 patients without angiographically significant disease, 124 had negative ultrafast CT coronary studies, for a specificity of 44%. An increasing number of vessels with calcification present on ultrafast CT was found to increase specificity for the presence of obstructive coronary artery disease in at least one vessel (P < .0001). As the log of the calcium score increases, the probability of multivessel obstructive disease increases (P < .0001). CONCLUSIONS: Ultrafast CT scanning is an noninvasive, non-exercise-dependent test with an excellent sensitivity for the detection of coronary artery disease. The presence of calcifications in multiple vessels and in younger populations correlates with higher specificities for obstructive disease, making ultrafast CT coronary scanning a very useful diagnostic test.

Adult↗

Coronary artery stenoses: a phantom study using contrast enhanced three-dimensional electron beam tomography.

This paper evaluated the accuracy of electron beam tomographic angiography (EBA) with conventional coronary arteriography (CCA) using four graded artificial stenoses in a postmortem swine coronary phantom model. The sensitivity, specificity, and accuracy of EBA for diagnosing significant stenosis (> or =50% stenosis) were 94.3%, 96.7%, and 95.8%, respectively. The diagnostic accuracy of EBA had no significant difference with CCA (chi(2)=0.0162; P>.05). EBA three-dimensional (3D) procedures had high interobserver reproducibility (k=.92-.95, P>.05). Maximum intensity projection (MIP) was the most sensitive and curved planar reformation (CPR) was the most accurate 3D procedure for quantitatively identifying coronary stenosis. EBA yields promising results concerning the visualization of coronary artery stenosis with high accuracy for stenoses >50%.

Animals↗