PubMed Health⌕ Search

Biomedical subjects

M J Collins

Publications and source records attributed to M J Collins.

At least 19 recordsLinked to original sources

Dynamics of ocular surface topography.

PURPOSE: To investigate fluctuations in the ocular surface, we used high-speed videokeratoscopy (50 Hz) to measure the dynamics of the ocular surface topography. METHODS: Ocular surface height difference maps were computed to illustrate the changes in the tear film in the inter-blink interval. Topography data were used to derive the ocular surface wavefront aberrations up to the fourth radial order of the Zernike polynomial expansion. We examined the ocular surface dynamics and temporal changes in the ocular surface wavefront aberrations in the inter-blink interval. RESULTS: During the first 0.5 s following a blink, the ocular surface height at the upper edge of the topography map increased by about 2 mum. Temporal changes occurred for some ocular surface wavefront aberrations and appeared to be related to changes in the distribution of tear film. CONCLUSION: In the clinical measurement of ocular surface topography using videokeratoscopy or optics of the eye using wavefront sensors, care should be taken to avoid the initial tear film build-up phase following a blink to achieve more consistent results.

Adult↗

The effect of the lipid layer on tear film behaviour.

This paper investigates the effect of surfactants during tear film deposition and subsequent thinning. The surfactants occur naturally on the surface of the tear film in the form of a lipid layer. A lubrication model is developed that describes lipid spreading and film height evolution. It is shown that lipids may play an important role in drawing the tear film up the cornea during the opening phase of the blink. Further, nonuniform distributions of lipids may lead to a rapid thinning of the tear film behind the advancing lipid front (shock). Experiments using a fluorescein dye technique and using a tearscope were undertaken in order to visualise the motion of the lipid layer and any associated shocks immediately after a blink. It is found that the lipid layer continues to spread upwards on the cornea after the opening phase of the blink, in agreement with the model. Using the experimental data, lipid particles were tracked in order to determine the surface velocity and these results are compared to the model predictions.

Blinking↗

Dynamics of tear film deposition and draining.

This paper investigates the deposition of the tear film on the cornea of the human eye. The tear film is laid down by the motion of the upper eyelid and then subsequently flows and thins. Of particular interest is the stability of the tear layer and the development of dry patches on the cornea. While there has been significant research on the behaviour of tear films between blinks, this paper focuses on understanding the mechanisms which control the shape and thickness of the deposited film and how this affects the subsequent film behaviour. Numerical and analytical methods are applied to a lubrication model which includes the effects of surface tension, viscosity, gravity and evaporation. The model reveals the importance of the eyelid velocity, motion of the surface lipid layer and the storage of tear film between blinks.

Cornea↗

Analysis of prosthetic cardiac devices: a guide for the practising pathologist.

Pathologists all over the world increasingly encounter prosthetic cardiac devices. A good evaluation of these devices is a valuable source of information, which can contribute to patient care and the appreciation and understanding of the pathobiology involved in the changes occurring between the host and the implanted prosthetic device. This article summarises the considerations underlying the analysis of prosthetic devices (particularly prosthetic heart valves), including the identification of the devices, the major morphological features of the devices, their modes of failure, and some technical details about evaluation and pitfalls.

Animals↗

Coronary artery stents: identification and evaluation.

First introduced in the 1980s, the coronary stent has been used to reduce the rate of arterial restenosis. Coronary stent implantation is currently a common procedure performed by interventional cardiologists, and the market for development and design is constantly expanding and evolving. This article was designed to assist pathologists in the accurate identification of coronary stents that are currently available, in addition to some that are no longer being implanted. The stents reviewed here were chosen based on frequency of use and/or occurrence in the literature. Some of the newer models have yet to undergo extensive clinical testing. The summaries accompanying each stent include concise physical descriptions and documented complications, intended to serve as a guide for the investigating pathologist.

Angioplasty, Balloon, Coronary↗

Aspartic acid racemization: evidence for marked longevity of elastin in human skin.

BACKGROUND: In extracellular proteins, aspartic acid racemization (AAR) has the potential to identify long-lived or permanent proteins. OBJECTIVES: We present data to show an age-dependent increase in AAR in chronologically aged skin elastin. METHODS: Elastin was purified in a multistep procedure designed to remove contaminating proteins and to avoid induced racemization. As a control experiment, elastin was also purified from the richest elastin bearing tissue, the yellow ligaments of the spine. RESULTS: In total skin, specimens displayed a slight age-dependent increase in d-aspartyl residues, but in purified elastin the rate of increase was rapid and highly correlated with age (r = 0.98). Similar rates were observed in the control data from the yellow ligaments. The AAR rates were found to be higher in elastin from skin (and yellow ligaments) than previous studies of lung parenchyma and from aorta had shown. These differences appear to be related to the purity of the extracted elastin product, and to a significant in vivo degradation of elastin in skin. CONCLUSIONS: The age-dependent accumulation of modified aspartic acid residues appears to be a common feature in ageing elastin, independent of the tissue source. This indicates a lack of turnover and an accumulation of elastin damage in diverse ageing tissues, possibly as part of programmed ageing.

Adolescent↗

Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium 3 years postoperatively.

PURPOSE: To investigate the effects of laser in situ keratomileusis (LASIK) on the corneal endothelium 3 years postoperatively. METHODS: Patients who were subjects of a previous prospective study (Am J Ophthalmol 125:465-471, (April) 1998) were contacted for a follow-up analysis of the central corneal endothelium. Noncontact specular microscopy was performed 35 to 37 months after LASIK on 52 eyes of 27 patients of the original cohort of 98 eyes of 65 patients and six eyes of three patients who were previously lost to follow-up after their initial post-LASIK evaluation. Patient age ranged from 29 to 66 years at the time of the original LASIK procedure. Attempted corrections ranged from 2.25 to 14.5 diopters of myopia, giving theoretical ablation depths of 182 to 332 microm below the corneal surface. Forty-eight eyes (83%) had a history of preoperative contact lens use (3 to 33 years). Central endothelial cell density, coefficient of variation of cell size, and percent of hexagonal cells were analyzed using 72 to 152 cells from each image. Multivariate analysis was used to search for factors that might predict changes in cell density, coefficient of variation, and percent of hexagonal cells. RESULTS: The mean +/- SD preoperative cell density was 2,498 +/- 354 cells per mm(2), the mean coefficient of variation was 0.36 +/- 0.07, and the percent of hexagonal cells was 58 +/- 6. Three years after surgery there was no statistically significant change in the mean endothelial cell density (2,489 +/- 335 cells per mm(2); P = 0.88, paired t test) or the percent of hexagonal cells (60 +/- 7; P = 0.14, paired t test). The mean coefficient of variation was significantly lower postoperatively (0.32 +/- 0.04; P = 0.0006, paired t test); a repeated measures analysis showed that this significant improvement could not be explained by cessation of contact lens wear after LASIK (P = 0.34). Multivariate analysis did not identify any factors that were predictive of change in cell density, coefficient of variation, and percent of hexagonal cells. CONCLUSIONS: Laser in situ keratomileusis for the correction of 2.25 to 14.5 diopters of myopia had no significant effect on central corneal endothelial cell density or the percent of hexagonal cells 3 years after surgery. The coefficient of variation of cell size improved significantly 3 years after surgery.

Adult↗

Flexure of thin rigid contact lenses.

The flexure of spherical rigid contact lenses was measured on the eyes of 10 young subjects using a videokeratoscope. Five subjects had little or no with-the-rule astigmatism (<0.75 D) andfive had moderate levels of with-the-rule astigmatism (1.00-2.00 D). Two lens materials (polymethylmethacrylate [PMMA] and Boston XO) in three centre thicknesses (0.05, 0.10 and 0.15 mm) were used in the study. No significant difference in the amount of flexure was found between the two materials tested. The degree of regular astigmatism on the lens front surface was found to increase as the centre thickness of the contact lens decreased. For the astigmatic group, the lenses with centre thicknesses of 0.05 mm had levels of front surface astigmatism similar to those of the underlying cornea. On spherical corneas the level of regular astigmatism can exceed that of the cornea for thinner lenses. When sphero-cylinder variations are accounted for, residual higher order aberration (root mean square) levels were found to approach those of the cornea when the lens thickness was reduced to 0.05 mm.

Journal Article↗

Ambient air quality at the site of a former manufactured gas plant.

Prior to the 1950's, manufactured gas was commercially produced from the pyrolysis of coal, coke, and oil at facilities that are termed manufactured gas plants (MGPs). The constituents of residual coal tar present on many MGP sites are an environmental health concern because of their toxicity and the possibility for their off-site migration via water and air. Atmospheric concentrations of five volatile organic compounds (VOCs, e.g., benzene), sixteen polycyclic aromatic hydrocarbons (PAHs, e.g., naphthalene) and particulate matter less than 10 microns in aerodynamic diameter (PM10) were measured at the site of a former MGP. Air samples were obtained before, during, and after excavation of subterranean coal tar at the site. The results of this investigation indicate that subterranean coal tar was not a primary source of VOCs and PAHs in the local atmosphere before or after remediation of the site. However, excavation, treatment, blending, and transfer of the coal tar during remediation generated concentrations of selected aromatic and semi-volatile organic compounds that were substantially greater than typical ambient levels. In addition, these data suggest that blending and mixing of coal tars could lead to exceedance of the U.S. National Ambient Air Quality Standard for PM10, although additional research is required to fully evaluate this possibility. Nuisance odors associated with the site remediation were likely the result of naphthalene and possibly isomers of xylene. Air pollutant concentrations measured adjacent to the excavation area and at the site perimeter during remediation activities were less than the relevant occupational and environmental exposure limits.

Air Pollution↗

The stability of corneal topography in the post-blink interval.

PURPOSE: Videokeratoscopes provide a wealth of information about the topography of the ocular surface. Although there have been numerous studies of the accuracy and precision of videokeratoscopes with inanimate test objects, little information exists on their precision (repeatability) for real eyes. METHODS: To investigate the stability of the ocular surface in the inter-blink period, 10 patients were recruited for videokeratoscopy. Tear break-up time was measured and videokeratographs were acquired immediately post-blink and again at 4, 8, and 12 seconds post-blink. To permit statistical inferences to be drawn from the data, we acquired 24 videokeratographs for each of the four post-blink intervals. The videokeratograph data were interpolated (bilinear) to a common grid, and average and standard deviation (SD) maps were derived for each post-blink condition. t Tests were used to test the significance of changes observed in the topography. RESULTS: The instantaneous power SD maps showed increasing variation toward the periphery, with most maps showing less than +/-0.5 diopters (D) of SD in the central 4 to 5 mm and variation in the periphery often reaching more than +/-1 D SD at the edge of an 8-mm diameter. When the 4-, 8-, and 12-second average maps were subtracted from the average map acquired immediately after blinking, regions of statistically significant ( p < 0.001) change were apparent in the upper and lower regions of the maps. The upper and lower bands of change were found to correlate with the natural position of the patients' lid margins. CONCLUSIONS: For normal eyes, the central regions of videokeratographs show high stability in the inter-blink period. However, the upper and lower edges of 8-mm diameter maps show statistically significant variability, which appears to be related to the effects of eyelid pressure.

Adult↗

Optimal modeling of corneal surfaces with Zernike polynomials.

Zernike polynomials are often used as an expansion of corneal height data and for analysis of optical wavefronts. Accurate modeling of corneal surfaces with Zernike polynomials involves selecting the order of the polynomial expansion based on the measured data. We have compared the efficacy of various classical model order selection techniques that can be utilized for this purpose, and propose an approach based on the bootstrap. First, it is shown in simulations that the bootstrap method outperforms the classical model order selection techniques. Then, it is proved that the bootstrap technique is the most appropriate method in the context of fitting Zernike polynomials to corneal elevation data, allowing objective selection of the optimal number of Zernike terms. The process of optimal fitting of Zernike polynomials to corneal elevation data is discussed and examples are given for normal corneas and for abnormal corneas with significant distortion. The optimal model order varies as a function of the diameter of the cornea.

Astigmatism↗

An improved method for the immunological detection of mineral bound protein using hydrofluoric acid and direct capture.

Immunological detection of proteins adsorbed to mineral and ceramic surfaces has proved not only difficult but controversial. Unlike the immunological detection of proteins associated with carbonate or phosphate minerals (e.g. shells and bones) proteins adsorbed to siliceous minerals cannot readily be removed by dissolution of the mineral phase. We have previously examined alternative extraction methodologies which claim to bring the protein into solution, but found none of these to be effective. Here we report a novel strategy for immuno-detection of proteins adsorbed to siliceous minerals, the Digestion and Capture Immunoassay (DACIA). The method involves the use of cold, concentrated (4M) hydrofluoric acid (HF) with the simultaneous capture of liberated protein onto a solid phase. The combination of low temperatures and surface stabilisation enables us to detect epitopes from even partially degraded proteins. The method may have a wide application in forensic, archaeological, soil and earth sciences.

Adsorption↗

Quality assurance in age estimation based on aspartic acid racemisation.

Estimates of the age of living and dead individuals, obtained in order to answer legal or social questions, require minimum quality standards in order to guarantee data quality. We present an outline strategy (with recommendations) for the attainment of quality assurance in age estimation based on aspartic acid racemisation. The strategy is based on a definition of minimum standards for laboratories, including documentation of procedures, methodology and levels of expertise, and the formulation of guidelines for intralaboratory and interlaboratory quality control.

Age Determination by Teeth↗

Age estimation: the state of the art in relation to the specific demands of forensic practise.

Age estimation in cadavers, human remains and living individuals may clarify issues with significant legal and social ramifications for individuals as well as for the community. In such cases methods for estimating age should fulfil the following specific demands: (1) they must have been presented to the scientific community, as a rule by publication in peer-reviewed journals, (2) clear information concerning accuracy of age estimation by the method should be available, (3) the methods need to be sufficiently accurate and (4) in cases of age estimation in living individuals principles of medical ethics and legal regulations have to be considered. We have identified and summarized the methods that essentially fulfil these specific demands. In childhood and adolescence morphological methods based on the radiological examination of dental and skeletal development are to be recommended. In adulthood, the accuracy of most morphological methods is much reduced. Here a biochemical method based on aspartic acid racemization in dentine provides the most accurate estimates of age, followed by special morphological dental and skeletal methods. The choice of method has to take account of the individual circumstances of each case. Most methods require either the consultation of specialised and trained scientists or an adequate calibration by the "user". Very few attempts have been made to find common standardisation, calibration and evaluation procedures or to develop means of quality assurance for methods of age estimation. Efforts in these directions are necessary to guarantee quality standards and adequate answers to the important legal and social issue of age estimation in forensic medicine.

Adolescent↗

The accuracy and precision performance of four videokeratoscopes in measuring test surfaces.

In this study we evaluated the accuracy and precision of three placido-disk videokeratoscopes (the Keratron, Medmont and TMS) and one videokeratoscope that uses the raster-stereogrammetry technique (PAR-CTS) in elevation topography with six test surfaces. The test surfaces were a sphere, an asphere, a multicurve, and three bicurve surfaces. Each instrument performed well on certain test surfaces, but none of the instruments excelled on all of the surfaces. The results showed high accuracy of the Keratron and Medmont instruments in measuring the sphere, asphere, and multicurve surfaces, but not the bicurve surfaces. The precision of the Keratron and Medmont instruments were high. The TMS and PAR-CTS instruments showed poorer accuracy than the Keratron and Medmont instruments for the multicurve test surface but showed better performance for the bicurve surfaces. The PAR-CTS had the poorest performance in precision of the four instruments. The use of the Noryl spherical test surface instead of polymethyl methacrylate (PMMA) resulted in small differences in the accuracy performance of the placido-disk videokeratoscopes only.

Cornea↗

A review of the methodological aspects of aspartic acid racemization analysis for use in forensic science.

Accurate age determination of adult cadavers and human remains is a key requirement in forensic practice. The current morphological methods lack accuracy and precision, require specialist training and are costly. The use of aspartic acid racemization (AAR) in human dentine provides a simple, cost-effective solution and the method can achieve accuracies of +/- 3 years at best. Currently, there are differences in AAR methodology between laboratories which produce different results on the rate of racemization in teeth. These inconsistencies must be resolved if the technique is to be successfully applied to age determinations in forensic cases. This paper reviews the differences in protocol which have been used, discusses how each method will affect the results obtained from AAR analysis and gives recommendations for optimization of the methological protocol as a first step towards international standardization.

Adult↗

Predicting protein decomposition: the case of aspartic-acid racemization kinetics.

The increase in proportion of the non-biological (D-) isomer of aspartic acid (Asp) relative to the L-isomer has been widely used in archaeology and geochemistry as a tool for dating. the method has proved controversial, particularly when used for bones. The non-linear kinetics of Asp racemization have prompted a number of suggestions as to the underlying mechanism(s) and have led to the use of mathematical transformations which linearize the increase in D-Asp with respect to time. Using one example, a suggestion that the initial rapid phase of Asp racemization is due to a contribution from asparagine (Asn), we demonstrate how a simple model of the degradation and racemization of Asn can be used to predict the observed kinetics. A more complex model of peptide bound Asx (Asn + Asp) racemization, which occurs via the formation of a cyclic succinimide (Asu), can be used to correctly predict Asx racemization kinetics in proteins at high temperatures (95-140 degrees C). The model fails to predict racemization kinetics in dentine collagen at 37 degrees C. The reason for this is that Asu formation is highly conformation dependent and is predicted to occur extremely slowly in triple helical collagen. As conformation strongly influences the rate of Asu formation and hence Asx racemization, the use of extrapolation from high temperatures to estimate racemization kinetics of Asx in proteins below their denaturation temperature is called into question. In the case of archaeological bone, we argue that the D:L ratio of Asx reflects the proportion of non-helical to helical collagen, overlain by the effects of leaching of more soluble (and conformationally unconstrained) peptides. Thus, racemization kinetics in bone are potentially unpredictable, and the proposed use of Asx racemization to estimate the extent of DNA depurination in archaeological bones is challenged.

Aspartic Acid↗