Fluorescence-enhanced optical imaging of large phantoms using single and simultaneous dual point illumination geometries.

Fluorescence-enhanced optical tomography is typically performed using single point illumination and multiple point collection measurement geometry. Single point illumination is often insufficient to illuminate greater volumes of large phantoms and results in an inadequate fluorescent signal to noise ratio (SNR) for the majority of measurements. In this work, the use of simultaneous multiple point illumination geometry is proposed for acquiring a large number of fluorescent measurements with a sufficiently high SNR. As a feasibility study, dual point excitation sources, which are in-phase, were used in order to acquire surface measurements and perform three-dimensional reconstructions on phantoms of large volume and/or significant penetration depth. Measurements were acquired in the frequency-domain using a modulated intensified CCD imaging system under different experimental conditions of target depth (1.4-2.8 cm deep) with a perfect uptake optical contrast. Three-dimensional reconstructions of the fluorescence absorption from the dual point illumination geometry compare well with the reconstructions from the single point illumination geometry. Targets located up to 2 cm deep were located successfully, establishing the feasibility of reconstructions from simultaneous multiple point excitation sources. With improved excitation light rejection, multiple point illumination geometry may prove useful in reconstructing more challenging domains containing deeply embedded targets. Image quality assessment tools are required to determine the optimal measurement geometry for the largest set off imaging tasks.

Breast↗

A comparison of exact and approximate adjoint sensitivities in fluorescence tomography.

Many approaches to fluorescence tomography utilize some form of regularized nonlinear least-squares algorithm for data inversion, thus requiring repeated computation of the Jacobian sensitivity matrix relating changes in observable quantities, such as emission fluence, to changes in underlying optical parameters, such as fluorescence absorption. An exact adjoint formulation of these sensitivities comprises three terms, reflecting the individual contributions of 1) sensitivities of diffusion and decay coefficients at the emission wavelength, 2) sensitivities of diffusion and decay coefficients at the excitation wavelength, and 3) sensitivity of the emission source term. Simplifying linearity assumptions are computationally attractive in that they cause the first and second terms to drop out of the formulation. The relative importance of the three terms is thus explored in order to determine the extent to which these approximations introduce error. Computational experiments show that, while the third term of the sensitivity matrix has the largest magnitude, the second term becomes increasingly significant as target fluorophore concentration or volume increases. Image reconstructions from experimental data confirm that neglecting the second term results in overestimation of sensitivities and consequently overestimation of the value and volume of the fluorescent target, whereas contributions of the first term are so low that they are probably not worth the additional computational costs.

Algorithms↗

Three-dimensional Bayesian optical image reconstruction with domain decomposition.

Most current efforts in near-infrared optical tomography are effectively limited to two-dimensional reconstructions due to the computationally intensive nature of full three-dimensional (3-D) data inversion. Previously, we described a new computationally efficient and statistically powerful inversion method APPRIZE (automatic progressive parameter-reducing inverse zonation and estimation). The APPRIZE method computes minimum-variance estimates of parameter values (here, spatially variant absorption due to a fluorescent contrast agent) and covariance, while simultaneously estimating the number of parameters needed as well as the size, shape, and location of the spatial regions that correspond to those parameters. Estimates of measurement and model error are explicitly incorporated into the procedure and implicitly regularize the inversion in a physically based manner. The optimal estimation of parameters is bounds-constrained, precluding infeasible values. In this paper, the APPRIZE method for optical imaging is extended for application to arbitrarily large 3-D domains through the use of domain decomposition. The effect of subdomain size on the performance of the method is examined by assessing the sensitivity for identifying 112 randomly located single-voxel heterogeneities in 58 3-D domains. Also investigated are the effects of unmodeled heterogeneity in background optical properties. The method is tested on simulated frequency-domain photon migration measurements at 100 MHz in order to recover absorption maps owing to fluorescent contrast agent. This study provides a new approach for computationally tractable 3-D optical tomography.

Bayes Theorem↗

Diagnostic imaging of breast cancer using fluorescence-enhanced optical tomography: phantom studies.

Molecular targeting with exogenous near-infrared excitable fluorescent agents using time-dependent imaging techniques may enable diagnostic imaging of breast cancer and prognostic imaging of sentinel lymph nodes within the breast. However, prior to the administration of unproven contrast agents, phantom studies on clinically relevant volumes are essential to assess the benefits of fluorescence-enhanced optical imaging in humans. Diagnostic 3-D fluorescence-enhanced optical tomography is demonstrated using 0.5 to 1 cm(3) single and multiple targets differentiated from their surroundings by indocyanine green (micromolar) in a breast-shaped phantom (10-cm diameter). Fluorescence measurements of referenced ac intensity and phase shift were acquired in response to point illumination measurement geometry using a homodyned intensified charge-coupled device system modulated at 100 MHz. Bayesian reconstructions show artifact-free 3-D images (3857 unknowns) from 3-D boundary surface measurements (126 to 439). In a reflectance geometry appropriate for prognostic imaging of lymph node involvement, fluorescence measurements were likewise acquired from the surface of a semi-infinite phantom (8x8x8 cm(3)) in response to area illumination (12 cm(2)) by excitation light. Tomographic 3-D reconstructions (24,123 unknowns) were recovered from 2-D boundary surface measurements (3194) using the modified truncated Newton's method. These studies represent the first 3-D tomographic images from physiologically relevant geometries for breast imaging.

Algorithms↗