Extending the dynamic range of phase contrast magnetic resonance velocity imaging using advanced higher-dimensional phase unwrapping algorithms.

Phase contrast magnetic resonance velocity imaging is a powerful technique for quantitative in vivo blood flow measurement. Current practice normally involves restricting the sensitivity of the technique so as to avoid the problem of the measured phase being 'wrapped' onto the range -pi to +pi. However, as a result, dynamic range and signal-to-noise ratio are sacrificed. Alternatively, the true phase values can be estimated by a phase unwrapping process which consists of adding integral multiples of 2pi to the measured wrapped phase values. In the presence of noise and data undersampling, the phase unwrapping problem becomes non-trivial. In this paper, we investigate the performance of three different phase unwrapping algorithms when applied to three-dimensional (two spatial axes and one time axis) phase contrast datasets. A simple one-dimensional temporal unwrapping algorithm, a more complex and robust three-dimensional unwrapping algorithm and a novel velocity encoding unwrapping algorithm which involves unwrapping along a fourth dimension (the 'velocity encoding' direction) are discussed, and results from the three are presented and compared. It is shown that compared to the traditional approach, both dynamic range and signal-to-noise ratio can be increased by a factor of up to five times, which demonstrates considerable promise for a possible eventual clinical implementation. The results are also of direct relevance to users of any other technique delivering time-varying two-dimensional phase images, such as dynamic speckle interferometry and synthetic aperture radar.

Algorithms↗

High-resolution magnetic resonance cholangiography (MRC) with adaptive averaging: diagnostic performance evaluation.

AIM: To evaluate the diagnostic performance of an interactive, adaptively averaged (AA) two-dimensional (2D) magnetic resonance cholangiography (MRC) technique in patients with suspected biliary disease by comparison to the standard MRC technique. MATERIALS AND METHODS: The AA 2D MRC method registers the images after acquisition, allowing summation of multiple images to improve the signal:noise ratio (SNR) and thereby potentially improve the visualization of bile ducts. One hundred and twenty-eight patients underwent both 2D conventional and AA magnetic resonance cholangiopancreatography (MRCP). Twenty-seven patients were excluded from the analysis as AA images could not be properly obtained due to technical failures. All examinations were performed using a 1.5 T whole-body MR system and a four-channel torso phased array coil. Images of 101 patients were adaptively averaged using an in-house developed program written in IDL. Two readers qualitatively evaluated the studies in consensus, blinded to acquisition details and without knowledge of clinical information. RESULTS: The AA technique was significantly better than the conventional 2D MRC for the visualization of the second-order branch intrahepatic ducts (p<00001). Overall, there was no significant difference in the diagnostic confidence between two techniques (p=0.12). However, the AA technique showed a trend towards more confident diagnosis of biliary strictures (p=0.055), likely due to better diagnostic confidence in identifying second order branch intrahepatic duct strictures (p=0.054). CONCLUSION: Excluding those patients those patients in whom either satisfactory respiratory gating or a suitable kernel placement was not achieved, AA 2D MRC demonstrated a significant improvement in visualization of intrahepatic duct branches compared to standard MRC.

Adolescent↗

CO2 as a distending medium for gastric and small bowel MRI: a feasibility study.

This work evaluates carbon dioxide as a contrast medium for magnetic resonance imaging of the stomach and small bowel. Twelve healthy volunteers underwent rapid magnetic resonance imaging after oral administration of a carbon dioxide generating agent using a combination of breath-hold and interactive fluoroscopic imaging during breathing. Diagnostic-quality images were obtained in 100% of cases for the stomach and in 92, 75, 67 and 42% of cases for the duodenal segments 1-4, respectively. Visualisation of the jejunum and ileum proved unacceptable for clinical use and anti-peristaltic agents did not significantly influence the results. Further development of fast imaging and magnetic resonance interactive fluoroscopic methods may allow the use of carbon dioxide as a contrast medium for clinical imaging of the stomach and duodenum.

Adult↗

Utility of an ultrafast magnetic resonance imaging protocol in recent and semi-recent strokes.

OBJECTIVE: To evaluate the technical feasibility of an integrated ultrafast head magnetic resonance (MR) protocol using a sensitivity encoding (SENSE) technique for depicting parenchymal ischaemia and vascular compromise in patients with suspected recent stroke. METHODS: 23 patients were evaluated with the ultrafast MR protocol using T2, T1, fluid attenuated inversion recovery (FLAIR), 3D time of flight magnetic resonance angiography (MRA), and diffusion weighted imaging (DWI) sequences. These were compared with routine conventional MR sequences. RESULTS: One patient could not tolerate conventional imaging, although imaging using the three minute head SENSE protocol was diagnostic. Both conventional and ultrafast protocols were of similar diagnostic yield in the remaining patients. There were no significant differences in clinical diagnostic quality for the T1, T2, FLAIR, and DWI sequences. One MRA examination was of better quality when SENSE was used, owing to reduced motion artefacts and shorter imaging time. CONCLUSIONS: It is possible to undertake a comprehensive MR examination in stroke patients in approximately three to five minutes. Ultrafast imaging may become a useful triage tool before thrombolytic therapy. It may be of particular benefit in patients unable to tolerate longer sequences. Further work is necessary to confirm these findings in hyperacute stroke.

Adult↗

Contrast-enhanced MR angiography for carotid disease: diagnostic and potential clinical impact.

OBJECTIVE: To compare contrast-enhanced MR angiography (CEMRA) with intra-arterial digital subtraction angiography (DSA) for evaluating carotid stenosis. METHODS: A total of 167 consecutive symptomatic patients, scheduled for DSA following screening duplex ultrasound (DUS), were prospectively recruited to have CEMRA. Three independent readers reported on each examination in a blinded and random manner. Agreement was assessed using the Bland-Altman method. Diagnostic and potential clinical impact of CEMRA was evaluated, singly and in combination with DUS. RESULTS: CEMRA tended to overestimate stenosis by a mean bias ranging from 2.4 to 3.8%. A significant part of the disagreement between CEMRA and DSA was directly caused by interobserver variability. For detection of severe stenosis, CEMRA alone had a sensitivity of 93.0% and specificity of 80.6%, with a diagnostic misclassification rate of 15.0% (n = 30). More importantly, clinical decision-making would, however, have been potentially altered only in 6.0% of cases (n = 12). The combination of concordant DUS and CEMRA reduced diagnostic misclassification rate to 10.1% (n = 19) at the expense of 47 (24.9%) discordant cases needing to proceed to DSA. An intermediate approach of selective DUS review resulted in a marginally worse diagnostic misclassification rate of 11.6% (n = 22) but with only 6.8% of discordant cases (n = 13). CONCLUSIONS: DSA remains the gold standard for carotid imaging. The clinical misclassification rate with CEMRA, however, is acceptably low to support its safe use instead of DSA. The appropriateness of combination strategies depends on institutional choice and cost-effectiveness issues.

Aged↗

Multi-sequence in vivo MRI can quantify fibrous cap and lipid core components in human carotid atherosclerotic plaques.

OBJECTIVES: Risk of thrombo-embolic stroke is thought to be better reflected by carotid plaque composition than by luminal stenosis. We set out to determine whether high resolution MRI was a valid method of quantifying plaque components in vivo. DESIGN: A prospective cohort study validating in vivo MRI against histological analysis of excised carotid plaques. MATERIALS: Twenty-five recently symptomatic patients with severe internal carotid artery stenosis underwent pre-operative in vivo multi-sequence MRI of the carotid artery using a 1.5 T system. METHODS: Individual plaque constituents were characterized on axial MR images according to net signal intensities. Analysis of fibrous cap and lipid core content was quantified proportional to overall plaque area. Bland-Altman plots were generated, and intra-class coefficients computed to determine the level of agreement between the two methods and inter-observer variability. RESULTS: The intra-class correlation coefficients between two MR readers were 0.94 and 0.88 for quantifying fibrous cap and lipid core components, respectively. There was good agreement between MR and histology derived quantification of both fibrous cap and lipid core content; the mean % difference for fibrous cap was 0.75% (+/-2.86%) and for lipid core was 0.86% (+/-1.76%). CONCLUSION: High resolution carotid MRI can be used to quantify plaque components and may prove useful in risk stratification.

Aged↗

Interactive body magnetic resonance fluoroscopy using modified single-shot half-Fourier rapid acquisition with relaxation enhancement (RARE) with multiparameter control.

PURPOSE: To develop a technique for interactive fluoroscopic abdominal magnetic resonance imaging (MRI) based on a single-shot half-Fourier rapid acquisition and relaxation-enhanced sequence. MATERIALS AND METHODS: The sequence was modified by incorporating inner-volume excitation, driven-equilibrium signal enhancement, and reduced flip angle refocusing pulses. Contrast control was provided by integrating "on-the-fly" selection of phase encoding view order, fat suppression, and section thickness. The resulting sequence was evaluated with phantom experiments to quantify the signal-to-noise ratio (SNR) effects of the modifications and in healthy volunteers for imaging the bile ducts, stomach, and duodenum using water and gaseous contrast media. RESULTS: Observed SNR relating to driven-equilibrium and flip angle scaling matched theoretical predictions. Volunteer examinations demonstrated the ability of the modified sequence to provide interactive, artifact-free imaging of the abdomen, including switching between conventional proton density-weighted, T2-weighted imaging and "hydrographic" projection imaging. CONCLUSION: Refinement of this technique may provide an abdomino-pelvic imaging capability similar in concept to real-time ultrasound, but with the advantages of MRI.

Abdomen↗

Colon carcinoma: MR imaging with CO2 enema--pilot study.

Prior to surgery, seven patients with known colonic tumors underwent breath-hold single-shot fast spin-echo magnetic resonance imaging during a CO2 enema. The images were evaluated for depiction of tumor, adjacent structures, and the remaining colon, and findings were compared with findings at surgery. In all seven patients, the tumor was demonstrated, and in four (57%), breach of the muscularis propria was correctly predicted.

Adult↗

A multicenter validation of an active contour-based left ventricular analysis technique.

Quantitative analysis of functional cardiac magnetic resonance (MR) images has been limited by the lack of well-validated, semiautomatic, methods for rapid analysis. We describe the evaluation of a DICOM-compatible PC-based parallel-processing tool, for cardiac magnetic resonance analysis (CAMRA), which supports semiautomatic image mensuration using an active contour model-based algorithm. The CAMRA software was used to analyze data from 12 patients in a multicenter acquisition and analysis trial to compare semiautomatic contour detection with manual planimetry of the left ventricular endocardium from short-axis, breath-held, cine gradient-echo images. There was excellent agreement between the manual and semiautomatic measurements of global left ventricular function, with no significant (P = 0.32) difference in the determination of ejection fraction (-0.9 +/- 3.1% [mean difference +/- 1 standard deviation]). There was no significant interobserver difference in the semiautomatically measured ejection fraction. Additionally, a single observer completed the analysis on data from 30 patients and found no significant (P = 0.05) difference in the determination of ejection fraction (-1.3 +/- 3.5% [mean difference +/- 1 standard deviation]). The CAMRA software demonstrates the capability for the reproducible evaluation of global left ventricular function in cardiac patients, with adequate interobserver reproducibility for use in multicenter trials.

Adult↗

High resolution magnetic resonance imaging of atherosclerosis and the response to balloon angioplasty.

OBJECTIVE: To explore the use of high resolution magnetic resonance imaging (MRI) of the popliteal artery in defining atheroscelerotic lesions and to monitor the remodelling response to balloon angioplasty. METHODS: Four patients (aged 49-67) with symptomatic discrete popliteal artery stenoses, as demonstrated by conventional angiography, underwent balloon angioplasty. MRI of the diseased vessel was performed before and one week, one month, three months, and six months after therapeutic balloon angioplasty. Cine phase contrast MRI was used to estimate blood flow just proximal to the lesion before and after angioplasty. RESULTS: In all patients the extent of the atherosclerotic plaque could be defined, such that even in segments of vessel which were angiographically "normal", atherosclerotic lesions with cross sectional areas ranging from 49% to 76% of potential lumen area were identified. Following angioplasty, plaque fissuring and local dissection were easily identified and serial changes in lumen diameter, blood flow. and lesion size could be documented. CONCLUSIONS: High resolution MRI can define the extent of atherosclerotic plaque in the peripheral vasculature and demonstrate the changes that occur with remodelling and restenosis following angioplasty. As a safe, reproducible technique MRI is ideal for assessing plaque and monitoring intervention, but further technological developments will be needed if similar or better images are to be achieved in other vascular beds.

Aged↗

Comparison of cardiac stroke volume measurement determined using stereological analysis of breath-hold cine MRI and phase contrast velocity mapping.

Cine MRI of the heart using segmented k-space pulse sequences permits multiphase images to be acquired in a single breath-hold. Whilst image quality is improved compared with conventional (non-segmented) cine imaging, subsequent analysis can be relatively time consuming. In this study, multiple slice breath-hold cine imaging of the heart was performed in 11 normal volunteers. Left and right ventricular stroke volume (SV) was estimated from the images by application of the Cavalieri method of modern design stereology in combination with point counting. The measured SVs were compared with those obtained by cine phase contrast velocity mapping in the ascending aorta and main pulmonary artery. Excellent agreement was found between the SVs determined by the two techniques, with mean differences (+/- one SD) of 0.41 +/- 3.00 ml and 0.41 +/- 4.78 ml for left and right ventricles, respectively. Comparison of left and right ventricular SV using stereology yielded a mean difference of 0.84 +/- 5.70 ml. Breath-hold data acquisition together with stereological analysis is demonstrated to be an accurate and unbiased technique for the rapid assessment of cardiac function.

Adult↗

Small bowel MRI using water as a contrast medium.

Magnetic resonance imaging (MRI) of the small bowel has been limited by lack of an adequate luminal contrast medium and problems with image artefacts. In this study we investigate the feasibility of imaging the luminal small bowel using rapid heavily T2w techniques, similar to those used for MR cholangiopancreatography, combined with oral water loading. Eight volunteers were examined after drinking 1-21 of water using serial, multisection, half-Fourier single shot rapid acquisition with relaxation enhancement (RARE) acquisitions. The examinations were continued until the terminal ileum was reached or the water reabsorbed. The results were subjectively assessed for visibility of the small bowel. In all subjects the duodenum, jejunum and ileum were well demonstrated with valvulae conniventes clearly visible. The water column reached the terminal ileum and the caecum in six of the eight subjects but in the remaining two water remained in the small bowel and was ultimately reabsorbed. These preliminary results suggest that with further refinement such an approach may be practical for clinical magnetic resonance imaging of the small bowel.

Adult↗

Magnetic resonance angiography.

Magnetic resonance angiography (MRA) permits the non-invasive visualization of blood flow through the effects of moving spins on the magnetic resonance signal. MRA techniques can be divided into two main classifications depending upon the primary effect responsible for contrast in the image. Angiograms can be produced using either the time-of-flight (TOF) or phase contrast (PC) methods. Each method has particular advantages and limitations as an angiographic imaging technique and these are reflected in their respective applications. This review article is intended to outline the scientific and technical development of MRA from its basis in the earliest in vitro nuclear magnetic resonance (NMR) experiments, through the implementation of in vivo angiographic techniques on whole body MRI systems, to the recent rapid expansion in MRA acquisition and processing techniques.

Contrast Media↗

The measurement of time-averaged flow by magnetic resonance imaging using continuous acquisition in the carotid arteries and its comparison with Doppler ultrasound.

A continuous acquisition method was used to measure the time-averaged flow in the carotid arteries of 10 normal volunteers, using an interleaved flow-sensitive and flow-compensated field echo sequence on a 1.5 T magnetic resonance (MR) system. Validation of the sequence and technique was performed using a pulsatile rotating phantom. The measured flow rates for the common carotid arteries were compared with Doppler ultrasound values obtained immediately after the MR measurement using a Duplex scanner. The correlation (r = 0.52, P less than 0.01) was significant with data spread accounted for by the inherent errors of both techniques. The difference between time-averaged flow measured by MR and Doppler ultrasound was 1.9%. Short-term reproducibility of each technique was assessed by consecutive measurements with values of 6.8% and 6.6% respectively for MR and Doppler; measurements after a 2 - 4 week interval gave a long-term reproducibility of 11.8% and 9.8% respectively. The advantages of continuous acquisition make the method suitable for non-invasive flow measurements, particularly for vessels that are not accessible to ultrasound.

Blood Flow Velocity↗