Oxygen-derived free radical scavengers for amelioration of reperfusion damage in heart transplantation.

In this study we tried to define the possible benefits of the oxygen-derived free radical scavengers after 3 hours of cold myocardial global ischemia, as required in the setting of cardiac transplantation. Twenty-one pig hearts were harvested after preservation with a cold cardioplegic solution (St. Thomas' Hospital solution) and topical cooling. Normothermic reperfusion with blood was achieved with a special heart-lung machine preparation, which allows the heart to beat in a working or nonworking mode. Twelve hearts served as control hearts (group I), and nine (group II) were subjected to superoxide dismutase and catalase. Superoxide dismutase was applied at a dose of 40 U/ml of cardioplegic solution and 1500 U/kg body weight with the start of reperfusion. Catalase was added to the cardioplegic solution in a dose of 100 U/kg and 3500 U/kg body weight with the start of reperfusion. After 15 minutes of retrograde reperfusion, both left ventricular developed pressure and its first derivative were significantly higher in group II (137 +/- 7.6 mm Hg, 2467 +/- 162 mm Hg/sec) than in group I (105 +/- 6 mm Hg, 1676 +/- 231 mm Hg/sec, p less than 0.05 for each). In addition, a considerably higher coronary blood flow was observed in group II throughout the 180-minute period of reperfusion (p = 0.047). We therefore conclude that the combined administration of superoxide dismutase and catalase during the initial period of cardioplegic arrest and during early reperfusion of donor hearts submitted to 3 hours of cold ischemia has a beneficial effect on myocardial performance.

Animals↗

In vivo determinants of energy consumption in electric motor driven artificial hearts.

To identify factors responsible for energy consumption, a retrospective investigation of the in-vivo performance of the 100 ml electric motor-driven left ventricular assist device (ELVAD), and the e-motor 100 ml total artificial heart, was undertaken. Multivariate regression analysis of the device parameters demonstrated that device flow, and estimated outlet pressure, were the most significant independent variables for predicting changes in motor power. Weighted least-square curvefit, using the product of these two variables, showed that changes in energy consumption can be well predicted for the ventricular assist device (r2 = 0.732). However, by applying the same model to the total artificial heart (ETAH), less favorable results were achieved (r2 = 0.422). In this model, device flow seemed to be more important in predicting energy consumption for the ETAH compared to the ELVAD. Therefore, changing the model by using flow to the third order significantly improved the fit (r2 = 0.6706) for the ETAH, and could compensate in part for the greater variability of the values and increased number of outliers in this group.

Animals↗

Emergency lung transplantation after extracorporeal membrane oxygenation.

In some patients with acute respiratory failure, the native lungs do not recover during extracorporeal membrane oxygenation (ECMO), or complications occur that preclude the meaningful continuation of ECMO therapy. In such cases, emergency lung transplantation (LTx) represents the only therapeutic alternative. Between May 1988 and April 1993, the authors have performed LTx after ECMO support in five of 111 lung or heart-lung transplantations (4.5%). Two patients presented with early graft failure after unilateral LTx. In these patients, ECMO was used as a bridging device to unilateral re-LTx for 1, resp. 11 days. One patient died 6 months post-operatively from chronic rejection; the other underwent a third LTx and is doing well after 42 months. In three further patients already treated with ECMO for 5 to 12 days for ARDS (n = 2) or acute respiratory failure after liver and kidney transplantation, the native lungs did not recover (n = 2) or pulmonary hemorrhage developed. The last patient (unilateral LTx) and one of the former (bilateral LTx for ARDS) are long-term survivors (12, 30 months). The remaining patient (unilateral LTx for ARDS) had severe multiorgan failure at the time of his operation and died intraoperatively. The authors conclude that ECMO no longer represents a contraindication to subsequent LTx. Their results also support the continued investigation of this combined therapeutic approach.

Adult↗

Intravascular oxygenation for advanced respiratory failure.

Severe acute respiratory failure of varying etiology may require the temporary use of artificial gas exchange devices. So far, extracorporeal membrane oxygenation and extracorporeal carbon dioxide removal have been used successfully for this purpose. A totally implantable intravascular oxygenator (IVOX) recently became available. The authors have used IVOX in three patients who presented with severe respiratory failure secondary to pneumonia (n = 2) and post-traumatic adult respiratory distress syndrome (n = 1). At the time of implantation, all patients had hypoxemia (PaO2 less than 60) despite a 100% inspired oxygen concentration and forced mechanical ventilation. The duration of IVOX therapy ranged from 12 to 71 hr. All patients initially showed improvement in arterial oxygenation, allowing for moderate reduction of ventilator therapy after several hours. In one patient the pulmonary status deteriorated further, and she died from multiple organ failure despite IVOX therapy. One patient could be stabilized but died from other causes. The third patient is a long-term survivor 18 months after IVOX therapy. Gas transfer capabilities of IVOX are limited when compared to extracorporeal membrane oxygenation, and this may restrict its clinical applicability in cases of severe adult respiratory distress syndrome. However, IVOX may be used successfully in selected patients with less severe respiratory failure.

Adolescent↗

In vitro and in vivo evaluation of a right ventricular assist device.

A simple right ventricular assist device (RVAD) has been developed. This device will be useful in situations where biventricular failure has been partially treated by placement of a left ventricular assist device, or when right ventricular failure occurs in isolation. This pneumatically actuated, R-wave synchronized, sac type pump contains no valves, and is connected by a graft to the pulmonary artery. The RVAD was tested in a circulation simulator to verify its hemodynamic efficacy and then implanted in six calves for 2-4 weeks to evaluate its biocompatibility. In vitro testing of the RVAD demonstrated that it restored normal hemodynamics in the presence of severe simulated RVF. In six animal implantations, a small amount of thrombus was found in one pump. No anticoagulants were employed. Thrombus was present in the connecting graft in three animals; in two this was clearly related to technical implant errors. No evidence of significant hemolysis was found. This simple RVAD has been found to be hemodynamically effective, is simple to use, and is well tolerated. Refinements in the interconnection graft between the pulmonary artery and the device are necessary.

Animals↗

Early graft failure after heart transplantation: management by extracorporeal circulatory assist and retransplantation.

Early graft failure represents a serious complication after orthotopic heart transplantation. Various modes of extracorporeal mechanical circulatory assistance, however, allow for "bridging" to heart retransplantation in these instances. We report a case of bridging to heart transplantation by means of intraaortic balloon counterpulsation. After transplantation a right ventricular assist device was required because of early graft failure while the intraaortic balloon pump was left in place. A retransplantation was successful, and 13 months after the operation the patient is in New York Heart Association functional class I. The cause of early graft failure, especially the tendency toward failure of the right ventricle, is not well understood and seems to be multifactorial, which suggests that an elevated pulmonary vascular resistance in the recipient possibly represents a considerable risk factor. Bridging to heart retransplantation with the use of extracorporeal blood pumps can be performed effectively.

Assisted Circulation↗

Preventive treatment of coronary vasculopathy in heart transplantation by inhibition of smooth muscle cell proliferation with angiopeptin.

BACKGROUND: The underlying mechanism of accelerated coronary vasculopathy in cardiac allografts still remains unclear. Our hypothesis was that inhibition of smooth muscle cell proliferation with the somatostatine analogue Angiopeptin may reduce vasculopathy. METHODS: Fifty-four patients received Angiopeptin injections (1500 micrograms x three times daily subcutaneously) for 21 days after the operation and three additional injections with every rejection treatment. Angiography was performed yearly, and data were compared with a matched historic control group. RESULTS: Actuarial survival was 85% at 1 year and 80% at 2 years, comparable with our results in general (80%/77%). Forty-six long-term survivors could be followed by coronary angiography. At 1 year, vasculopathy was assessed in nine patients (17%). Of the 18 patients investigated at 2 years thus far, an additional three patients were found to have vasculopathy. In the control group vasculopathy was comparable, being 13% after 1 year and 20% after 2 years. A significantly lower incidence of rejections and lower creatinine values were found in the study group within the entire observation period (p < 0.05). CONCLUSIONS: We conclude that Angiopeptin treatment appears to be safe without significant side effects; it may reduce the number of acute rejections, at least during the first year after heart transplantation. However, the results of the 2-year follow-up in the remaining patients would have to be included in assessing the effect of Angiopeptin. Long-term follow-up will be necessary to decide whether Angiopeptin will be helpful in reducing the incidence of transplant vasculopathy.

Actuarial Analysis↗