The effect of linear contrast flow acceleration on catheter tip recoil in selective arteriography.

We investigated the effect of the device known as the linear accelerator flow control (linear-rise) available on some angiographic power injectors used for delivering contrast medium. Its influence on catheter tip recoil during selective arteriography was evaluated in two glass models, which simulated assessment of catheter position in visceral and cerebral arterial branches. Contrast medium was injected over a clinical range with and without the linear flow accelerator in operation. Biplane high speed video recordings simultaneously referenced time in thousandths of seconds and the catheter position. The linear flow accelerator failed to prevent, but did delay, catheter tip recoil in proportion to the prolongation of contrast medium injection time. These laboratory results conformed with the findings of catheter behavior during similar experiments in animals undergoing arteriography.

Angiography↗

Cine-computed tomography of arrhythmogenic right ventricular dysplasia.

The CT diagnostic features of arrhythmogenic right ventricular dysplasia (Uhl anomaly) are described in a 72-year-old man. High speed cine-CT was performed using millisecond exposures and multilevel scanning. Ventricular morphology and function were evaluated, and findings were compared with two-dimensional echocardiography and equilibrium gated blood pool imaging. Cine-CT showed a dilated hypokinetic right ventricle with a markedly thin anterior wall and normal left sided chambers. The clinical aspects of Uhl anomaly are reviewed.

Aged↗

Cine-computed tomography of Ebstein anomaly.

A case of Ebstein anomaly is reported, and the diagnostic potential of cine-CT in assessing the magnitude of the anatomic changes and the presence of right to left intracardiac shunting is evaluated.

Cineradiography↗

MR imaging of the thoracic aorta in Marfan patients.

A characteristic shape of the ascending aorta has been reported in patients with Marfan syndrome. To evaluate the capability of magnetic resonance (MR) imaging to distinguish between marfanoid and other aortic aneurysms, 11 Marfan patients (group 1), eight patients with ascending aorta enlargement (group 2), and 20 normal subjects (group 3) had transverse and sagittal MR of the thoracic aorta. Aortic diameter was measured at the sinuses of Valsalva (SV), the caudal portion of the ascending aorta, the prearch region (PA), the middle arch, and the descending aorta. The ratio SV/PA was significantly greater (p less than 0.001) in group 1 compared with groups 2 and 3. The SV/PA in all Marfan patients exceeded 1.4 but was less than 1.3 in subjects of groups 2 and 3. Magnetic resonance imaging provides definitive measurements of aortic dimensions and is potentially the method of choice for establishing the diagnosis of aortic involvement in Marfan syndrome and monitoring the course of aortic enlargement.

Aorta↗

Cine-CT measurement of cortical renal blood flow.

A modified indicator-dilution technique using radiographic contrast material and a cine-CT scanner was used to measure blood flow in the renal cortex of dogs. To validate this technique, CT measurements were correlated with simultaneous measurements of flow determined by radioactive microspheres. Measurements were taken during euvolemic conditions and after hemorrhage. Thirty-nine measurements were compared, covering a flow range from 1 to 7 ml min-1 g-1, and a good correlation was found between the cine-CT and microsphere results (r = 0.93; p less than 0.001). Additionally, cine-CT measurements were made of the mean transit time (MTT) of contrast material through the renal cortex, and the reciprocal of these MTT values was also well correlated to microsphere determined flow (r = 0.94; p less than 0.001). Thus, cine-CT appears to be a promising new technique for measuring renal blood flow.

Animals↗

Evaluation of regional ventricular wall motion by ECG-gated CT.

A conventional whole body CT scanner equipped for electrocardiographic gating was used to evaluate regional left ventricular function and the findings were compared with a corresponding analysis by two-dimensional echocardiography and left ventriculography. Twenty-two patients between the ages of 40 and 77 years with a documented anterior or posterolateral myocardial infarction were studied together with a control group comprising 10 patients. The gated CT studies were obtained using three 1 cm levels selected through the mid, apical, and basal regions of the left ventricle. Qualitative analysis of segmental wall motion (p less than 0.0001) correlated with angiography in 82% and with two-dimensional echocardiography in 86% (p less than 0.0001). Computed tomography correctly identified the location of prior myocardial infarction in all but one patient. The results of this study suggest that gated CT may provide an accurate assessment of regional left ventricular function (for anterior and posterolateral myocardial infarction) and that this technique may prove to be clinically useful if these early results are confirmed by further experience.

Adult↗

Quantitation of intracardiac shunts by cine-CT.

Quantitation of intracardiac shunts is important in the evaluation of congenital heart disease and ventricular septal defects postmyocardial infarction. Shunt detection and quantitation is currently performed by either oximetry or radionuclide angiography. Oximetry is an invasive technique and radionuclide angiography, although noninvasive, does not have sufficient spatial resolution to provide detailed anatomic information. The present study evaluated a new technique for quantitating right-to-left shunts by analysis of indicator dilution curves acquired noninvasively using cine-CT. This technique was evaluated in a phantom and in postoperative dogs with a surgically created variable shunt. The phantom model demonstrated the accuracy and reproducibility of the curve analysis algorithm, and the canine model permitted the comparison of oximetry with cine-CT for shunt quantitation. Cine-CT accurately estimated right-to-left shunt fraction when compared with oximetry (r = 0.91) and is more sensitive than oximetry in detecting small shunts. The results of this study suggest that contrast enhanced cine-CT provides a precise noninvasive technique for measuring shunt lesions in congenital and acquired heart diseases.

Animals↗

Synergistic enhancement of MRI with Gd-DTPA and magnetization transfer.

Magnetization transfer (MT) between protons of macromolecules and protons of water molecules is a recently introduced mechanism for tissue contrast in MR imaging. The MT effect is strong in tissues where there is an efficient cross relaxation between macromolecular protons and water protons and where this interaction is the dominant source of relaxation. Paramagnetic ions shorten relaxation times and decrease the MT effect. These two facts led to the assumption that, in the case of contrast enhanced MRI, the combination of the T1-weighted imaging method and the MT technique may yield increased contrast, compared with standard methods. The synergistic effect is demonstrated in this work with studies of egg white samples and by imaging three patients with different brain pathologies. The lesion-to-white matter contrasts, with standard T1-weighted sequences with and without the MT effect, were compared before and after the introduction of Gd-DTPA. In each case the synergistic effect of T1 weighting and MT improved the contrast enhancement provided with Gd-diethylenetriamine pentaacetic acid.

Brain↗

Liver perfusion studied with ultrafast CT.

OBJECTIVE: Our goal was to quantify absolute hepatic arterial and portal venous perfusion noninvasively in patients with and without liver disease using ultrafast CT. MATERIALS AND METHODS: A single slice through the porta hepatis was repeatedly scanned after bolus injection of 25 ml of iohexol 300 mg I/ml, followed by a 25 ml saline "chaser" intravenously at 10 ml/s. Thirty-nine controls, 7 cirrhotic patients, and 5 patients with known metastases on the slice plane were studied; hepatic arterial perfusion was determined in 41 patients and portal venous perfusion in 24. Time-attenuation curves from regions of interest drawn over the liver, spleen, aorta, and portal vein were analysed. Hepatic arterial perfusion was calculated by dividing the peak gradient of the liver time-attenuation curve prior to the time of peak splenic attenuation by the peak aortic CT number increase. Splenic perfusion was calculated by dividing the peak gradient of the splenic time-attenuation curve by the peak aortic CT number increase. Portal perfusion was derived by scaling the splenic time-attenuation curve by the ratio of hepatic arterial/splenic perfusion. This scaled curve was subtracted from the liver time-attenuation curve to give a portal curve. The peak up-slope of this curve was divided by the peak rise in splenic or portal vein density. RESULTS: Hepatic arterial perfusion averaged 0.19 ml/min/ml (n = 31) in controls and was raised in cirrhosis to 0.25 ml/min/ml (n = 6) and metastases 0.43 ml/min/ml (n = 4). Portal venous perfusion was 0.93 ml/min/ml (n = 19) in controls and 0.43 ml/min/ml (n = 4) in cirrhosis. Reproducibility has been confirmed. CONCLUSION: Dynamic ultrafast CT shows potential in quantifying arterial and portal hepatic perfusion. The technique may be adaptable to dynamic bolus MRI.

Female↗

Flow measurements with a high-speed computed tomography scanner.

A high-speed computed tomography (CT) scanner with a scan time of 50 ms was used to measure flow in a phantom constructed to simulate both tissue and vessels. After a bolus injection of iodinated contrast medium, the phantom was scanned at a rate of up to 2 images/s. A gamma-variate curve was fit to the time-density data obtained from the inlet and outlet, as well as from the tissue-equivalent part of the phantom. Flow was then calculated using different curves and curve parameters according to the Stewart-Hamilton equation, the mean transit time, and a modification of the Sapirstein principle. Actual flow rates were assessed by timed sampling. The results demonstrated that high-speed CT can measure flow accurately by all these methods. Application of high-speed CT for flow measurements in experimental animals and patients is, therefore, promising. The limitations of each technique for clinical application are discussed.

Blood Flow Velocity↗

Attenuation changes of the normal and ischemic canine kidney. Dynamic CT scanning after intravenous contrast medium bolus.

The potential of CT scanning to explore total and regional renal blood flow was evaluated in a dog model with unilateral renal artery stenosis (n = 7, reduction of renal blood flow: 32-75% of base line flow). Attenuation versus time curves were generated for the renal cortex and medulla, as well as for the aorta and renal vein. A fast CT scanner was used which allowed for up to 24 scans/minute at the same level (slice thickness: 10 mm). A total of 10 ml contrast medium was injected into a peripheral vein for each scan series taken. During baseline conditions, the curve of the renal cortex and medulla demonstrated 2 peaks. The first peak was mainly related to early vascular enhancement, whereas the second peak corresponded mainly to the appearance of contrast medium in the distal convolutes and collecting ducts. Ischemia of the kidney resulted in a reduction of the first peak and a flattening of the leading edge slope. Transport of contrast medium through the extravascular compartments of the kidney was delayed during ischemia. Relative renal blood flow was obtained from the CT data by dividing peak enhancement by rise-time as assessed from the cortical curve. All measurements were related to baseline flow and validated by flow measurements using radioactive labeled microspheres (n = 5). Correlation was found to be r = 0.97.

Animals↗