PubMed Health⌕ Search

Biomedical subjects

M J Lipton

Publications and source records attributed to M J Lipton.

At least 91 records · Page 5Linked to original sources

Spatial resolution analysis of computed tomographic images.

Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, and ring discontinuities. The model-dependent methods utilize multiparameter fits of a two-dimensional model function to the image data. Model predictions are compared with results obtained in a model-independent way by numerical transformation of the data. Results of resolution measurements of an Imatron C-100 CT scanner at UCSF and a second experimental scanner at the UCSF Physics Research Laboratory are presented.

Humans↗

Obstruction of the superior vena cava or subclavian veins: sonographic diagnosis.

The normal subclavian vein shows a respiratory rhythmicity on sonograms and responds to a sudden sniff maneuver by collapsing in a rapid, transient manner secondary to the sudden decrease in intrathoracic pressure. Of 11 patients studied using ultrasound (US) for possible superior vena cava (SVC) obstruction, five patients with proved SVC obstruction had no response of the enlarged subclavian veins to respiratory maneuvers. One patient with a partial obstruction had a minimal response on one side. Two patients with isolated subclavian vein obstructions had no response on the affected side and a normal response on the contralateral side. Three patients proved not to have SVC obstruction had normal responses. Sonography of the subclavian veins may be an effective, indirect screening technique for the presence of SVC obstruction and can also be used to evaluate the patency of the subclavian vein, although the sensitivity and specificity of the method remain to be determined from a larger, prospective study.

Constriction, Pathologic↗

Measurement of cardiac output by cine computed tomography.

High-speed computed transmission tomography (cine CT) is a new noninvasive technique that may be useful for the rapid, accurate quantitation of cardiac function. The capability of cine CT to assess cardiac output was examined 10 mongrel dogs as an initial step in validating this method. After the dogs were anesthetized, femoral arterial pressure and pulmonary artery thermodilution catheters were inserted. After intravenous injection of a bolus of contrast medium, cine CT scans were performed in the flow mode, in which 50-ms scans were triggered electrocardiographically at end-diastole at 8 levels during sequential cardiac cycles. Scans and thermodilution measurements of cardiac output were obtained at rest and during altered hemodynamic states induced by separate infusions of dobutamine and phenylephrine. Time-density analysis was performed over the left ventricular cavity and curves were fitted to the CT flow data by gamma-variate analysis. Using the Stewart-Hamilton equation established for indicator dilution techniques, the cardiac output was calculated. The results established a direct linear correlation (r = 0.92) between cine CT cardiac output and thermodilution cardiac output over a wide range of cardiac outputs (1.5 to 6.3 liters/min). This study demonstrates that cine CT can provide a reliable estimate of cardiac output noninvasively using contrast medium as an indicator in dogs.

Cardiac Output↗

Magnetic resonance imaging in hypertrophic cardiomyopathy.

Gated magnetic resonance imaging (MRI) was performed using a 0.35-Tesla cryogenic system in 14 patients with hypertrophic cardiomyopathy (HC) in order to define the site and extent of abnormal wall thickness. These studies were compared with 2-dimensional (2-D) echocardiograms. Gated magnetic resonance imaging studies in 12 normal volunteers were used for comparison. In normal subjects and in patients with HC, the sharp demarcation of the myocardial wall permitted measurement of wall thickness. The thickness of the septal and posterolateral walls in normal subjects was 10.2 +/- 0.4 mm (+/- standard deviation) and 10.8 +/- 0.5 mm, respectively, whereas septal thickness in all but 1 patient with HC was 15.0 mm or greater. In patients with HC, septal and posterolateral wall thickness were 2.2 +/- 0.8 cm and 1.3 +/- 0.17 cm, respectively, by MRI. The 2-D echocardiographic measurements for septal and posterolateral walls were 2.4 +/- 0.6 cm and 1.4 +/- 0.7 cm, respectively. The severity and distribution of abnormal wall thickness were comparable on 2-D echo and MRI. Gated MRI is an effective and completely noninvasive technique for demonstrating the presence, site and extent of abnormal wall thickness in HC. The large field of view, ability to image directly in multiple planes, and discrete blood-endocardial interfaces are advantages for cardiovascular imaging.

Adult↗

In vivo assessment of left ventricular wall and chamber dynamics during transient myocardial ischemia using cine computed tomography.

Using a new computed tomographic (CT) scanner design that uses a rapidly moving focused electron beam, 50-ms CT scans were obtained at 2 axial levels simultaneously through the hearts of 6 dogs in order to analyze left ventricular (LV) wall thickness and cross-sectional chamber area after acute occlusion of the left anterior descending coronary artery (LAD). Ten or fifteen 50-ms CT scans (rate of 17 scans/s through the middle of the left ventricle were performed in 1 second (cine acquisition) during intravenous administration of contrast medium at rest, 60 seconds after acute occlusion of the LAD, and 60 seconds after release of the occlusion. The percent extent of systolic wall thickening of the potentially ischemic anterior segment was 37 +/- 15% (+/- standard deviation) in the control state and -5 +/- 6.5% during LAD occlusion (p less than 0.01). There was no significant difference in the percent change in LV luminal area from end-diastole to end-systole between the control state (50 +/- 19%) compared with LAD occlusion (47 +/- 21%). There were no significant differences in the extent of systolic wall thickening or LV luminal area between the control state and 60 seconds after release of occlusion. The alterations in regional myocardial function during acute ischemia are characterized by wall thinning during systole in the jeopardized segment and no significant change in global LV function. These features can be assessed by cine computed tomography during a solitary heart cycle.

Animals↗

Computed axial tomography of the heart.

CT scanning provides useful cardiac imaging but has not become a routine clinical tool for heart disease due to long exposure times (2-5 seconds) and the limitation of single slice acquisition. A revolutionary high speed (Cine) CT electron beam scanner was designed at UCSF, with multilevel millisecond scanning speed at rates of 17 scans per second. Table tilt and swivel permits direct imaging in various planes including the half axis view. Images can be analysed as closed loop movies, and quantitation of wall thickening, wall mass and ejection fractions are being validated. High resolution imaging without the need for gated acquisition is a significant advantage over nuclear medicine and magnetic resonance imaging, and physiology can be studied with exercise of other interventions. Fast CT can measure vessel blood flow and has great potential for estimating myocardial perfusion using indicator dilution theory and small peripheral intravenous injection of contrast medium. Cine CT could become the noninvasive modality of choice in cardiovascular diagnosis - the scanner has universal application for all organ systems.

Cineradiography↗

Feasibility, reliability, and advantage of utilizing low contrast dose digital subtraction ventriculography in a conventional catheterization laboratory.

Ventriculography was performed with conventional biplane fluoroscopic equipment; a 1:4 dilution of contrast medium in a standard injectate volume was delivered by a power injector. The biplane images were acquired with two video tape recorders and enhanced by means of a portable digital image processor. By a simple modification and calibration of our standard light pen-computer system, volumes could be calculated and global and segmental wall motion analysis performed. Fifteen patients underwent conventional and low-dose left ventriculography. Good correlation was found in end-diastolic volume (EDV), in end-systolic volume (ESV), and in ejection fraction (EF) (r = 0.90, r = 0.93, and r = 0.92, respectively). The quality of the images enabled a frame-by-frame analysis of a cardiac cycle to be performed (r = 0.99 when compared in one patient) and regional wall motion abnormalities identified (21 out of 23 abnormal segments). Although conventional ventriculography caused a rise in left ventricular end-diastolic pressure (17 +/- 8 vs 23 +/- 11, p less than 0.002) and no change in systolic blood pressure (132 +/- 23 vs 135 +/- 23, p greater than 0.5), low-dose ventriculography had no effect on left ventricular end-diastolic pressure (18 +/- 7 vs 21 +/- 10, p greater than 0.05) and produced a rise in systolic blood pressure (144 +/- 20 vs 149 +/- 22, p less than 0.05). A system of digital enhancement that is capable of producing high-quality ventriculograms with lessened contrast morbidity can be assembled with minimal expense and adapted to any conventional catheterization laboratory.

Cardiac Catheterization↗

Computed tomography of the heart: evaluation of anatomy and function.

Diseases of the heart and blood vessels represent one of the most challenging problems for advanced diagnostic imaging systems. Computed tomographic scanning is potentially an ideal cardiac imaging modality since it is a cross-sectional imaging method with very high resolution. Currently available computed tomographic scanners have exposure speeds of 1 to 5 seconds, which are inadequate for the majority of cardiovascular imaging applications. Nevertheless, a variety of limited computed tomographic scanning techniques have been successfully performed in selected patient subgroups. These methods require the administration of contrast medium injected or infused into a peripheral vein, combined with either dynamic computed tomographic scanning or some form of electrocardiographic gated computed tomography. The newer conventional computed tomographic scanners can display anatomic structures in the heart and great vessels with considerable fidelity and provide not only cross-sectional displays but also, by means of computer manipulation, any selected reconstructed images in oblique, coronal or sagittal projections. Feasibility studies indicate improved accuracy of computed tomographic measurements of cardiac chamber volumes. Physiologic measurements include estimation of shunt flows and cardiac output and analysis of myocardial wall thickening. The full potential of computed tomography should be reached once fast, multiple slice, computed tomographic scanners using scanning electron beam techniques become available. The prototype CVCT (cine computed tomographic C-100 scanner) designed at the University of California, San Francisco, is now undergoing evaluation. This instrument images up to eight contiguous slices at the rate of 16 to 24 images/s. The computed tomographic scanner specifically designed for cardiac imaging should extend the utility of computed tomography in the evaluation of cardiac diseases and the study of cardiovascular physiology.

Heart↗

Assessment of cardiac anatomy using nuclear magnetic resonance imaging.

Nuclear magnetic resonance imaging has emerged in the past few years as a completely noninvasive method for medical imaging of internal organs. Because of the loss of signal intensity by motional nuclei (hydrogen) using most proton imaging techniques, flowing blood within the cardiovascular system generates little or no signal and consequently there is high natural contrast between blood and the walls of blood vessels or cardiac chambers. However, motion during imaging also complicates cardiac imaging because signal is lost from the nuclei in the moving cardiac structures. Consequently electrocardiographic gating of data acquisition is required for nuclear magnetic resonance imaging of the heart. Distinct advantages of nuclear magnetic resonance imaging in relation to other imaging modalities are good contrast between soft tissues and the capability for characterization of specific tissues by estimation of magnetic relaxation times. Early in vitro studies measuring relaxation times of myocardial tissue samples of excised hearts indicate that nuclear magnetic resonance imaging will be capable of discriminating infarcted from normal myocardium. Recent studies using electrocardiographically gated nuclear magnetic resonance imaging of dogs with acute infarction showed the infarct as a region of high intensity on spin-echo images. Initial clinical experience with electrocardiographically gated nuclear magnetic resonance imaging (0.35 tesla) in patients has clearly defined internal cardiac anatomy without the use of contrast media. This technique has demonstrated the consequence of previous myocardial infarction such as regional wall thinning, aneurysm, thrombus and contractile dysfunction, a number of pericardial abnormalities and the morphology of hypertrophic and congestive cardiomyopathies.

Coronary Circulation↗

Effects of intravenous administration of a new nonionic dimeric contrast medium on the coronary circulation. Comparison with monomeric ionic and nonionic media.

Contrast media injected into the circulation produce a variety of cardiovascular effects. Agents with low osmolality and low concentrations of cations cause considerably less hemodynamic effects. This study compared the effects of a nonionic dimer, iotrol, which has an osmolality (340 mosm/kg) close to that of serum (290 mosm/kg), with a standard ionic monomer, meglumine diatrizoate, and a nonionic monomer, iosimide. The effects of intravenous bolus injection of these three contrast agents on coronary and systemic hemodynamics were studied in eight anesthetized dogs. The influence of the contrast media on subendocardial and subepicardial perfusion was assessed by injecting radioactive microspheres into the left atrium 30 seconds after injection of the media. Alterations in coronary hemodynamics occurred with both iosimide and meglumine diatrizoate. Iotrol produced minimal changes in coronary hemodynamics. Thus, iotrol is the least perturbing contrast indicator and seems the best for use in quantitative digital subtraction and dynamic computed tomography studies designed to measure myocardial perfusion.

Animals↗

Magnetic resonance imaging of the heart: a review of the experience in 172 subjects.

Gated magnetic resonance (MR) imaging was used to evaluate central cardiovascular anatomy in 172 subjects, 31 of whom were healthy volunteers. Using the spin-echo technique, images of diagnostic quality were obtained in 93% of cases with TE = 28 msec and in 65% of cases with TE = 56 msec. Transverse multisection sequences encompassing most of the left ventricle required approximately 6-8 minutes. Corroborative studies were available in 134 of 141 patients who had cardiovascular disease; two dimensional echocardiograms and angiography in 133 and 100 patients, respectively. Gated MR demonstrated the wall thinning and complications caused by prior myocardial infarctions and high signal intensity of the myocardium at the site of acute myocardial infarctions. MR accurately demonstrated anatomic abnormalities owing to hypertrophic and congestive cardiomyopathies, congenital abnormalities of the heart and great vessels, rheumatic heart disease, pulmonary hypertension, and cardiac and paracardiac masses. Depiction of cardiovascular anatomy and pathoanatomy was attained without the use of any contrast media. Consequently, gated MR is an effective technique for cardiac diagnosis. The short time required for tomographic examination of the entire heart using the multisection technique renders this a practical cardiac imaging modality.

Adolescent↗

Regional myocardial dysfunction: evaluation of patients with prior myocardial infarction with fast CT.

A prototype ultrafast cine computed tomographic (CT) scanner, designed specifically for cardiac imaging, was used to evaluate a preliminary series of patients with prior myocardial infarction (n = 21) and a control group without coronary artery disease (n = 5). Multilevel 50-msec CT scan exposures were obtained during peripheral intravenous bolus injections of contrast medium. A comparison was made between cine-CT scans and standard left ventriculographic images in assessing segmental left ventricular motion. Results indicate that cine CT, performed at sufficiently rapid speeds (20 scans per second) to allow useful analysis of regional ventricular wall motion, can provide adequate image quality. Analysis of 110 segments revealed a good correlation (90.9%) between the two techniques in characterizing normal from abnormal regional wall motion. Cine CT, based on this initial study, demonstrates considerable potential for evaluating not only cardiac chamber dimensions but also segmental wall dynamics.

Adult↗

Detection and characterization of acute myocardial infarction in man with use of gated magnetic resonance.

To evaluate the capability of magnetic resonance imaging (MRI) in the detection and characterization of alterations in signal intensity and T2 relaxation time in acutely infarcted relative to normal myocardium 16 adult patients and normal volunteers were studied by electrocardiographically gated proton MRI. The seven volunteers were entirely asymptomatic and had no history of cardiovascular abnormality. The nine patients had each suffered an acute myocardial infarction within 5 to 12 days before the MRI studies. The diagnosis in each patient was confirmed by electrocardiographic (ECG) criteria and elevated levels of fractionated creatine kinase (CK) isoenzymes. Electrocardiographically gated MRI was performed with a superconducting system operating at 0.35 tesla. MRI demonstrated infarcted myocardium as a region of high signal intensity relative to that of adjacent normal myocardium; regions of high intensity corresponded anatomically to the site of infarction as defined by the ECG changes. The mean percent difference between normal and infarcted myocardium was substantially greater on 56 msec images (70.2 +/- 21.3%) compared with 28 msec images (27.1 +/- 13.6%). Region of interest analysis revealed that infarcted myocardium had a significantly (p less than .01) prolonged T2 relaxation time (mean T2 = 80.9 msec) relative to that in normal myocardium (mean T2 = 42.3 msec) and relative to the mean T2 of left ventricular myocardium in the volunteers (mean T2 = 42.4 msec). An additional finding for each patient with myocardial infarction was a high intraluminal flow signal on 56 msec images, but this was also observed in normal subjects and is therefore a nonspecific finding.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Determination of left ventricular mass in dogs with rapid-acquisition cardiac computed tomographic scanning.

The development of left ventricular hypertrophy in patients with heart disease often has far-reaching clinical implications with respect to overall morbidity and mortality. Approaches used to assess left ventricular mass include electrocardiography, echocardiography, contrast ventriculography, single photon-emission tomography, and conventional computed tomography. However, all of these modalities suffer from some major draw back that precludes widespread application to all patients. In this study we assessed the accuracy of determinations of left ventricular mass in 22 dogs by rapid-acquisition (50 msec) computed axial tomography (RACAT), an ultrafast computed tomographic (CT) instrument. Electrocardiographically triggered, end-diastolic, short-axis cardiac scans were obtained from apex to base during administration of intravenous iodinated contrast. Myocardial edges were determined for each tomographic scan by two methods: the regional half-contour method (the CT density half way between that of the left ventricular myocardium and adjacent ventricular cavities or lung) and "interactive plateau thresholding" of the cardiac borders. Left ventricular mass by RACAT was calculated as the sum of the mass of each individual scan from apex to base (modified Simpson's rule). Postmortem left ventricular mass ranged from 58 to 160 g. The correlation between true left ventricular mass and tomographically determined mass was excellent (r = .99), with the slope and y intercept not statistically different from 1 and 0, respectively. The standard error of the estimate was 4.1 g. Interobserver and intraobserver variability for determining left ventricular mass demonstrated excellent agreement (r = .99 and r = .99, respectively). We conclude that quantitative assessment of left ventricular mass can be accurately and reproducibly performed in dogs by rapid acquisition CT scanning. It is likely that this technique will be readily transferable to the clinical settings and prove to be an important method for quantifying left ventricular mass in patients.

Animals↗

Dynamic CT scanning of the normal canine liver: interpretation of time density curves resulting from an intravenous bolus injection of contrast material.

Seven adult male mongrel dogs were monitored by electromagnetic flow probes and string occluders around the hepatic artery and portal vein. Then, time density curves of the liver, aorta and portal vein were recorded using dynamic CT scanning following the bolus injection of contrast material into a peripheral vein (n = 7) and a mesenteric vein branch (n = 5). Information on total hepatic blood flow could not be obtained from the mesenteric vein injection. The hepatic time density curve could, however, be broken into its two components, hepatic arterial and portal venous flow contribution, by selective ligation of the hepatic artery or portal vein. It could be demonstrated that the arterial component of liver enhancement reached its peak at the end of the aortic wash-out of contrast material. Thus, the hepatic time-density curve could be broken in its two components by superimposing the aortic time density curve onto the hepatic curve. An attempt was made to estimate relative portal venous blood flow by using the slopes or the peaks of both components of the hepatic curve. Using the slopes of the hepatic curve resulted in a consistent underestimation of portal venous blood flow, whereas the peaks gave an estimate of portal venous flow with an accuracy within +/- 8%.

Animals↗