Publications and source records attributed to M J Maryanski.

11 recordsLinked to original sources

Characterisation of PRESAGE: A new 3-D radiochromic solid polymer dosemeter for ionising radiation.

For the past 50 years there has been interest in developing 3-D dosemeters for ionising radiation. Particular emphasis has been put on those dosemeters that change their optical properties in proportion to the absorbed dose. Many of the dosemeters that have been evaluated have had limitations such as lack of transparency, diffusion of the image of the dose distribution or poor stability of baseline optical density. Many of these performance limitations have been overcome by the development of PRESAGE, an optically clear polyurethane-based radiochromic 3-D dosemeter. The solid PRESAGE dosemeter is formulated with a free radical initiator and a leuco dye and it does not require a container to maintain its shape. The polyurethane matrix is tissue equivalent and prevents the diffusion of the dose distribution image. There is a linear dose-response, which is independent of both photon energy and dose rate. Simple precautions such as preventing long-term exposure to additional ionising radiation including ultraviolet and controlling storage temperatures prevent the bleaching of the radiochromic response field within the irradiated dosemeter.

Dose-Response Relationship, Radiation↗

Image registration of BANG gel dose maps for quantitative dosimetry verification.

BACKGROUND: The BANG (product symbol SGEL, MGS Research Inc., Guilford, CT) polymer gel has been shown to be a valuable dosimeter for determining three-dimensional (3D) dose distributions. Because the proton relaxation rate (R2) of the gel changes as a function of absorbed dose, MR scans of the irradiated gel can be used to generate 3D dose maps. Previous work with the gel, however, has not relied on precise localization of the measured dose distribution. This has limited its quantitative use, as no precise correlation exists with the planned distribution. This paper reports on a technique for providing this correlation, thus providing a quality assurance tool that includes all of the steps of imaging, treatment planning, dose calculation, and treatment localization. METHODS AND MATERIALS: The BANG gel formulation was prepared and poured into spherical flasks (15.3-cm inner diameter). A stereotactic head ring was attached to each flask. Three magnetic resonance imaging (MRI) and computed tomography (CT) compatible fiducial markers were placed on the flask, thus defining the central axial plane. A high-resolution CT scan was obtained of each flask. These images were transferred to a radiosurgery treatment-planning program, where treatment plans were developed. The gels were irradiated using our systems for stereotactic radiosurgery or fractionated stereotactic radiotherapy. The gels were MR imaged, and a relative 3D dose map was created from an R2 map of these images. The dose maps were transferred to an image-correlation program, and then fused to the treatment-planning CT scan through a rigid body match of the MRI/CT-compatible fiducial markers. The fused dose maps were imported into the treatment-planning system for quantitative comparison with the calculated treatment plans. RESULTS: Calculated and measured isodose surfaces agreed to within 2 mm at the worst points within the in-plane dose distributions. This agreement is excellent, considering that the pixel resolution of the MRI dose maps is 1.56 x 1.56 mm, and the treatment-planning dose distributions were calculated on a 1-mm dose grid. All points within the dose distribution were well within the tolerances set forth for commissioning and quality assurance of stereotactic treatment-planning systems. Moreover, the quantitative evaluation presented here tests the accuracy of the entire treatment-planning and delivery process, including stereotactic frame rigidity, CT localization, CT/MR correlation, dose calculation, and radiation delivery. CONCLUSION: BANG polymer gel dosimetry coupled with image correlation provides quantitative verification of the accuracy of 3D dose distributions. Such quantitative evaluation is imperative to ensure the high quality of the 3D dose distributions generated and delivered by stereotactic and other conformal irradiation systems.

Gels↗

The role of specific side groups and pH in magnetization transfer in polymers.

The nature of water-macromolecule interactions in aqueous model polymers has been investigated using quantitative measurements of magnetization transfer. Cross-linked polymer gels composed of 94% water, 3% N,N'-methylene-bis-acrylamide, and 3% functional monomer (acrylamide, methacrylamide, acrylic acid, methacrylic acid, 2-hydroxyethyl-acrylate, or 2-hydroxyethyl-methacrylate) were studied. Water-macromolecule interactions were modified by varying the pH and specific functional group on the monomer. The magnitudes of the interactions were quantified by measuring the rate of proton nuclear spin magnetization exchange between the polymer matrix and the water. This rate was highly sensitive to the presence of carboxyl side groups on the macromolecule. However, the dependence of the rate on pH was not consistent with simple acid/base-catalyzed chemical exchange, and instead, the data suggest that multiequilibria proton exchange, a wide distribution in surface group pK values, and/or a macromolecular structural dependence on pH may play a significant role in magnetization transfer in polymer systems. These model polymer gels afford useful insights into the relevance of chemical composition and chemical dynamics on relaxation in tissues.

Acrylamides↗

Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters.

PURPOSE/OBJECTIVE: The measurement of complex dose distributions (those created by irradiation through multiple beams, multiple sources, or multiple source dwell positions) requires a dosimeter that can integrate the dose during a complete treatment. Integrating dosimeter devices generally are capable of measuring only dose at a point (ion chamber, diode, TLD) or in a plane (film). With increasing use of conformal dose distributions requiring shaped, noncoplanar beams, there will be an increased requirement for a dosimeter that can record and display a 3D dose distribution. The use of a 3D dosimeter will be required to confirm the accuracy of treatment plans produced by the current generation of 3D treatment-planning computers. METHODS AND MATERIALS: The use of a Fricke-infused gel and magnetic resonance imaging (MRI) to demonstrate the localization of stereotactic beams has been demonstrated (11). The recently developed BANG polymer gel dosimetry system (MGS Research, Inc., Guilford, CT), based on radiation-induced chain polymerization of acrylic monomers dispersed in a tissue-equivalent gel, surpasses the Fricke-gel method by providing accurate, quantitative dose distribution data that do not deteriorate with time (6, 9). The improved BANG2 formulation contains 3% N,N'-methylene-bisacrylamide, 3% acrylic acid, 1% sodium hydroxide, 5% gelatin, and 88% water, where all percentages are by weight. The gel was poured into volumetric flasks, of dimensions comparable to a human head. The gels were irradiated with complex beam arrangements, similar to those used for conformal radiation therapy. Images of the gels were acquired using a Siemens 1.5T imager and a Hahn spin-echo pulse sequence (90 degrees-tau-180 degrees-tau-acquire, for different values of tau). The images were transferred via network to a Macintosh computer for which a data analysis and display program was written. The program calculates R2 maps on the basis of multiple TE images, using a monoexponential nonlinear least-squares fit based on the Levenberg-Marquardt algorithm. The program also creates a dose-to-R2 calibration function by fitting a polynomial to a set of dose and R2 data points, obtained from gels irradiated in test tubes to known doses. This function can then be applied to any other R2 map, so that a dose map can be computed and displayed. RESULTS: Through exposure to known doses of radiation, the gel has been shown to respond linearly with dose in the range of 0 to 10 Gy, and its response is independent of the beam energy or modality. Dose distributions have been imaged in orthogonal planes, and can be displayed in a convenient form for comparison with isodose plans. The response of the gel is stable; the gel can be irradiated at any time after its manufacture, and imaging can be conducted any time following a brief interval after irradiation. CONCLUSION: The polymer gel dosimeter has been shown to be a valuable device for displaying three-dimensional dose distributions. The imaged dose distribution can be compared easily with calculated dose distributions, to validate a treatment planning system. In the future, gels may be prepared in anthropomorphic phantoms, to confirm unique patient dose distributions.

Gels↗

Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter.

The effects of varying the weight fraction (%C) of the crosslinker N, N'-methylene-bisacrylamide (bis) per total amount of monomer (6% w/w), and the NMR measurement temperature, on the dose response of the transverse relaxation rate (R2) of bis-acrylamide-nitrogen-gelatin (BANG) aqueous polymer gel dosimeters have been investigated. The gel samples were irradiated in test tubes with 250 kV x-rays, and the water proton NMR transverse relaxation rates were measured at 0.47 T using a Carr-Purcell-Meiboom-Gill multiecho pulse sequence. Both the dose sensitivity (slope of the linear portion of an R2-dose response) and the maximum rate at which the R2-dose response saturated (R2max), were found to depend strongly on the crosslinker fraction and on the temperature of the R2 measurement. The dose sensitivity peaked at approximately 50% C, and, for this composition, varied from 0.14 s-1 Gy-1 at 40 degrees C to 0.48 s-1 Gy-1 at 10 degrees C. The maximum transverse relaxation rates ranged from 0.8 s-1 at 33% C and 40 degrees C to 11.8 s-1 at 83% C and 5 degrees C. These results suggest that water proton transverse relaxation in the gel is controlled by an exchange of magnetization between the aqueous phase and the semi-solid protons associated with the polymer, and that the latter experience spectral broadening from immobilization which increases with crosslinking or cooling. Theoretical and practical implications of the above findings are discussed in the paper.

Acrylamides↗

Test objects for MRI quality assurance based on polymer gels.

Radiation-sensitive polymer gels have been adapted for making test objects that can be used to assess the imaging characteristics of magnetic resonance imaging (MRI) systems. The polymer gels contain acrylic monomers within a gel matrix, and when irradiated with x rays the constituents polymerize to produce highly cross-linked microparticles that dramatically affect water NMR relaxation rates where they form. The size of these effects depends on the radiation dose and composition of the mixture irradiated, while the spatial pattern of relaxation time changes can be precisely controlled by spatial modulation of the x-ray exposure. This permits the manufacture of complex test patterns free of susceptibility or edge effects, and overall image performance can be assessed by constructing contrast-detail diagrams using a singly irradiated gel containing areas of different sizes and contrasts. Polymer gels are stable and a variety of different tests objects can be constructed inexpensively. Such materials and test phantoms may find widespread application in diagnostic MRI quality assurance and testing programs.

Acrylic Resins↗

The effects of cross-link density and chemical exchange on magnetization transfer in polyacrylamide gels.

The effects of polymer structure and water-macromolecule interactions on proton relaxation in an aqueous model polymer have been investigated using quantitative measurements of magnetization transfer. Polyacrylamide gels composed of 95% water, 5% comonomers acrylamide and N,N'-methylene-bis-acrylamide were studied. The structure and rigidity were varied by changing the cross-linking density of the polymer. The polymer showed a biphasic change in transverse relaxation with increasing cross-linking density which was accompanied by a sudden increase in magnetization transfer above 40% cross linking. This change may be attributed to the formation of rigid domains in the polymer which exhibit solid-like behavior with a short T2 (11 microseconds) and a Gaussian lineshape. Water-macromolecule interactions were controlled by varying the pH of the gel. At high pH (> 8), there was an increase in magnetization transfer and transverse relaxivity consistent with a chemical-exchange-mediated interaction between water protons and the polymer. By analyzing the system as two proton reservoirs coupled by magnetization exchange, the proton populations, intrinsic relaxation rates, and exchange rates were estimated, for different degrees of cross linking and pH. This model affords useful insights into the relevance of both supramolecular structure and chemical exchange on relaxation in tissues.

Acrylic Resins↗

Radiation therapy dosimetry using magnetic resonance imaging of polymer gels.

Further progress in the development of polymer gel dosimetry using MRI is reported, together with examples of its application to verify treatment plans for stereotactic radiosurgery and high dose rate brachytherapy. The dose distribution image produced in the tissue-equivalent gel by radiation-induced polymerization, and encoded in the spatial distribution of the NMR transverse relaxation rates (R2) of the water protons in the gel, is permanent. Maps of R2 are constructed from magnetic resonance imaging data and serve as a template for dose maps, which can be used to verify complex dose distributions from external sources or brachytherapy applicators. The integrating, three-dimensional, tissue-equivalent characteristics of polymer gels make it possible to obtain dose distributions not readily measured by conventional methods. An improved gel formulation (BANG-2) has a linear dose response that is independent of energy and dose rate for the situations studied to date. There is excellent agreement between the dose distributions predicted using treatment planning calculations and those measured using the gel method, and the clinical practical utility of MRI-based polymer gel dosimetry is thereby demonstrated.

Acrylamide↗

Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter.

A new formulation of a tissue-equivalent polymer-gel dosimeter for the measurement of three-dimensional dose distributions of ionizing radiation has been developed. It is composed of aqueous gelatin infused with acrylamide and N, N'-methylene-bisacrylamide monomers, and made hypoxic by nitrogen saturation. Irradiation of the gel, referred to as BANG, causes localized polymerization of the monomers, which, in turn, reduces the transverse NMR relaxation times of water protons. The dose dependence of the NMR transverse relaxation rate, R2, is reproducible (less than 2% variation) and is linear up to about 8 Gy, with a slope of 0.25 s(-1)Gy(-1) at 1.5 T. Magnetic resonance imaging may be used to obtain accurate three-dimensional dose distributions with high spatial resolution. Since the radiation-induced polymers do not diffuse through the gelatin matrix, the dose distributions recorded by BANG gels are stable for long periods of time, and may be used to measure low-activity radioactive sources. Since the light-scattering properties of the polymerized regions are different from those of the clear, non-irradiated regions, the dose distributions are visible, and their optical densities are dependent on dose.

Acrylic Resins↗

NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI.

A new type of tissue-equivalent medium for magnetic resonance imaging of the dose distributions produced by ionizing radiation has been developed. Agarose gel is infused with acrylamide and N,N'-methylene-bis-acrylamide (Bis) comonomers, which are readily polymerized by free radical initiators in de-aerated aqueous solutions. Polymerization and cross-linking induced locally by free radical products of water radiolysis increase the rate of water proton spin relaxation gradually up to doses of about 15 Gy. The slopes of the dose-response curves at 64 MHz are 0.015 and 0.28 s-1 Gy-1 for R1 and R2, respectively. The agarose matrix as well as the high (50% by weight) relative concentration of the cross-linker (Bis) per total comonomer limit the spread of polymerization so that the spatial distribution of the radiation dose is faithfully represented in the resultant spatial distribution of relaxation rates. The gel can be imaged with conventional magnetic resonance imaging devices with high spatial resolution and accuracy. In addition, due to the well established effect of the precipitation of insoluble agglomerates of highly cross-linked acrylamide, the optical turbidity of the gel increases gradually with the absorbed dose. This may provide an additional means of visualizing the dose distribution in three dimensions. The major advantage of the acrylamide-Bis-agarose gels over those that depend on ionic chemical dosimeters, for example, Fricke-infused gels, lies in the lack of diffusion of radiation-induced chemical changes subsequent to or concurrent with irradiation.

Acrylamide↗

Assessment of the accuracy of stereotactic radiosurgery using Fricke-infused gels and MRI.

The treatment plans for stereotactic radiosurgery employ small, circular, noncoplanar fields applied in a series of arcs, or with synchronous rotation of the accelerator gantry and patient support assembly. Primary or metastatic brain tumors and arterial-venous malformations are localized in relation to a stereotactic head frame using CT, MRI, and angiography. As x-ray doses in the range of 20-40 Gy are delivered in a single treatment, it is critical that the dose distribution produced by the accelerator accurately reflect the one developed by the treatment planning computer. Until the advent of Fricke-infused gels, whose NMR characteristics are changed by irradiation, there was no practical method for assessing the accuracy of x-ray beam positioning on a target that was localized by both CT and MRI. A stereotactic head frame was attached to a hollow glass head filled with a Fricke-infused gel. A 2-mm target point at approximately the center of this manikin was localized by CT and MRI. The head frame was then mounted to the patient support assembly of a linear accelerator, and given a dose of 40 Gy to the isocenter from 6-MV x rays using a modified version of the dynamic stereotactic radiosurgery plan developed in Montreal. Subsequent MRI showed the target point at the center of the dose distribution, thus confirming the accuracy of the stereotactic radiosurgery procedure. This demonstrated the unique characteristics of the Fricke-infused gel for the simultaneous localization of x-ray beams in three dimensions.

Gels↗