Esophageal speaker articulation of /s,z/: a dynamic palatometric assessment.

Esophageal talker linguapalatal contact patterns and durations during /s/ and /z/ productions were examined using dynamic palatometry instrumentation. It was found that sibilant groove narrowing is a physiologic compensation for a reduced air supply in esophageal speech. The place of esophageal /s, z/ articulation was on the anterior portion of the alveolar ridge as seen in normal speakers. Average medial groove width for esophageal /s/ was narrower than the 5-7-mm groove characteristic of normal speakers. Groove widths averaged 3 mm for /s/ and 4 mm for /z/. Systematic changes in groove widths across speech sounds, syllable position, and vowel context were also observed. Use of a narrower lingual groove was interpreted as a significant articulatory maneuver to meter out a limited intraoral air supply and effect more normal fricative durations.

Articulation Disorders

Temporomandibular joint sounds and condyle/disk relations on magnetic resonance images.

This study compared the condyle/disk relationships on magnetic resonance images (MRIs) in a group of subjects with completely silent temporomandibular joints (TMJ) when tested clinically with those in subjects with readily discernible TMJ sounds. The sounds were recorded with an accelerometer as the transducer. Selected degrees of jaw separation were electronically determined and recorded with interocclusal wafers for use with the imaging process. Of the "silent joints" 89% were found to have sounds when tested with the accelerometer. These "subclinical" sounds tended to be of shorter duration and occurred at a greater degree of vertical opening than the clinically discernable sounds. The MRIs of the group with clinically discernable sounds tended to show a change in the relationship between the head of the condyle and the intermediate zone of the disk, at the degree of jaw separation of the sound occurrence, whereas no condyle/disk change occurred in the group with "clinically silent joints." It is likely that all joints create sound during function. The different characteristics of the subclinical sounds versus the clinical sounds may indicate differing sound origins.

Adult

Fluorescence intensity resolution in flow systems.

The factor which can limit fluorescence intensity resolution in a flow cytometer of the type in which cells pass perpendicularly through a focussed laser beam depends on signal intensity. For the brightest sources (e.g. fluorescent DNA stains), the coefficient of variation (CV) is limited in our system to around 3% by stream hydrodynamics, unstable illumination intensity, nonstoichiometric staining, etc. The weakest detectable sources (e.g. fluorescent cell-surface labels) are limited in coefficient of variation by shot noise in the photomultiplier due to constant background light levels. Finally, over a fairly wide brightness range between these extremes, resolution is determined primarily by photoelectron statistical variation on the signal itself (i.e. "photon statistics"). Thus photon collection and detection efficiency (solid angle, barrier filter passband, detector quantum efficiency) become of primary importance.

Cells

Measurement of cytoplasmic fluorescence depolarization of single cells in a flow system.

We have built a flow system in which we can analyze and sort individual viable cells on the basis of their cytoplasmic microviscosity. The average cytoplasmic microviscosity (or cytoplasmic structuredness) of a cell can be quantitated by exciting fluorescein molecules in the cytoplasm of the cell with a polarized light source and measuring the extent of depolarization of the fluorescent signal. Changes in the state of a cell (e.g., the reception of a signal inducing the cell to differentiate) often appear to be associated with changes in cytoplasmic microviscosity, these changes being detectable within hours of the inducing signal. An example of one such change is presented.

Bone Marrow

Dynamic palatometry.

A computer-based instrumental system is described for continuous palatometry. Thin pseudopalatal plates (approximately 0.2 mm) with embedded electrodes are used to detect linguapalatal contact during speech articulation. Geometric configurations of such contacts are then derived and displayed to reveal articulatory characteristics.

Computers

MR imaging of the vocal tract during vowel production.

Modeling of vocal tract behavior during speech production requires accurate measurements of the entire vocal tract. To accomplish this, magnetic resonance (MR) imaging was performed on a 0.5-T system with a custom-made, double-loop, wrap-around coil. A midsagittal section of the region from the glottis to the lips was imaged during sustained production of five American English vowels. A gradient-spoiled gradient-echo sequence was used to achieve a 4-second imaging time. Images showed clear profiles of the entire vocal tract and exhibited essential articulatory features of vowel production. It was possible to measure midsagittal widths at various points along the vocal tract with 1-mm resolution. The measurements were used to construct a tube model for prediction of the acoustic output of the vocal tract. It is concluded that risk-free MR imaging promises to be an important means of acquiring data for vocal tract modeling, with applications to speech pathology, linguistics, and artificial speech.

Humans