PubMed Health⌕ Search

Biomedical subjects

M J Niebauer

Publications and source records attributed to M J Niebauer.

26 records · Page 2Linked to original sources

Efficacy and safety of defibrillation with rectangular waves of 2- to 20-milliseconds duration.

The effect of suprathreshold defibrillator shocks on cardiac function was compared in 8 isolated, perfused, contracting canine hearts using 4 durations of rectangular electrical waveforms. Defibrillation threshold was first determined for each duration; then overdose shocks of 3, 4.5, 6, and 9 times threshold current density were delivered. Left ventricular isovolumic systolic pressure decreased immediately after the shocks in proportion to the overdose shock strength. The mean defibrillation current density thresholds for the 2-, 5-, 10-, and 20-msec durations were 101, 63, 47, and 39 mA/cm2, respectively. The corresponding energy density thresholds were 4.6, 3.5, 4.4, and 6.4 mJ/cm3, respectively. The safety factor for defibrillation was defined as the current overdose ratio (delivered current density/threshold current density) required to produce a 50% decrease in isovolumic systolic pressure immediately after the shock. This dose was determined by interpolation of the curve for depression versus overdose of shock strength. The mean current safety factors for the 2-, 5-, 10-, and 20-msec durations were 3.9, 5.1, 5.4, and 5.2, respectively. The corresponding mean energy safety factors were 15, 25, 28, and 27. The margin of safety for functional depression of the heart was significantly less (p less than 0.05) for the 2 msec rectangular wave then for the 5-, 10-, and 20-msec rectangular waves.

Animals↗

Cardiopulmonary resuscitation with interposed abdominal compression in dogs.

This study was conducted to evaluate the hemodynamic effectiveness of a new modification of cardiopulmonary resuscitation (CPR), termed interposed abdominal compression-CPR (IAC-CPR). IAC-CPR utilizes all the steps of standard CPR with the addition of abdominal compressions interposed during the release phase of chest compression. Ventricular fibrillation was induced electrically in 10 anesthetized dogs, and either IAC-CPR or standard CPR was initiated while arterial and venous blood pressures and cardiac output were monitored. The two CPR methods were alternated every 3 minutes over a period of 30 minutes. The addition of interposed abdominal compressions to standard CPR improved arterial pressures and perfusion in 10 of 10 dogs. Brachial arterial blood pressure averaged 87/32 mm Hg during IAC-CPR vs 58/16 mm Hg during standard CPR. Cardiac output (+/- SE) averaged 24.2 +/- 5.7 ml/min/kg during IAC-CPR vs 13.8 +/- 2.6 ml/min/kg during standard CPR. IAC-SPR requires no extra mechanical equipment, and, if proven effective in human trials, may improve resuscitation success in the field and in the hospital.

Abdomen↗

The effect of newer antiarrhythmic drugs on defibrillation threshold.

This study was conducted to determine the effects of clofilium phosphate and bretylium tosylate on ventricular defibrillation threshold. Dogs were anesthetized with pentobarbital and subjected to repeated fibrillation-defibrillation episodes. Defibrillation thresholds were determined at 15-min intervals, using underdamped 5--6 msec sinusoidal current shocks, from 30 min before drug injection to 120 min after injection. Eight dogs were given clofilium phosphate (0.34 mg/kg, iv). Another 10 dogs were given bretylium tosylate (10.0 mg/kg, iv). Both drugs lowered defibrillation threshold from 15--90 min after injection. The maximum clofilium effect was a 31% decrease in threshold current and a 54% decrease in threshold energy. The greatest decrease in defibrillation threshold produced by bretylium was 16% for current and 31% for energy. These drug induced changes in defibrillation threshold are of potential clinical benefit if they occur in human subjects at doses which are effective for control of ventricular arrhythmias.

Animals↗

Aortic baroreceptor characteristics in dogs with chronic high output failure.

It has been shown that the arterial baroreflex is depressed in heart failure. The role of alterations in afferent discharge as a possible mechanism for this depression has not been investigated previously. Single unit aortic baroreceptor activity was recorded from six normal dogs and from nine dogs, each with a chronic aorto-caval fistula (AVF). At the time of the acute experiment, mean arterial blood pressure (MABP) was not significantly different in the two groups of dogs; however, pulse pressure was significantly higher in the AVF dogs (45.7 +/- 2.4 mm Hg vs, 24.4 +/- 2.0 mm Hg; p less than 0.001). Left ventricular end-diastolic pressure (LVEDP) was higher in the AVF dogs (31.3 +/- 2.0 vs 5.6 +/- 1.8 mm Hg; p less than 0.001). AVF dogs had elevated heart weight/body weight ratios. The relationship of systolic aortic pressure to systolic discharge was examined by changing aortic pressure with aortic and vena caval occluders. The peak gain (normalized to maximum discharge) averaged 2.19 +/- 0.27 in the normal dogs compared to 1.15 +/- 0.09 in the AVF group (p less than 0.01). Saturation pressures and maximum discharge rates were greater in the AVF dogs although the threshold pressures were not different in the two groups. This data suggests that there is an attenuated response of aortic baroreceptor discharge in dogs with chronic volume overload and this abnormality may partially be responsible for the abnormal baroreflex in heart failure.

Animals↗

Management of atrial flutter.

Atrial flutter is a macroreentrant arrhythmia that is associated with cardiovascular and pulmonary disease. In the United States, 200,000 new cases of atrial flutter can be expected to develop every year with a male to female ratio of over 2:1. This arrhythmia is associated with atrial fibrillation in over half the cases. It is also associated with an increased risk of thromboembolic complications, but less than that is seen with atrial fibrillation. The most common form of atrial flutter involves a large reentrant circuit within the right atrium, encircling the tricuspid annulus. Other, less common forms of atrial flutter may involve other anatomic barriers, atriotomy scars, and infarcted areas of the atria. Treatment of atrial flutter often involves electrical cardioversion and/or antiarrhythmic medications. Type I and Type III antiarrhythmic drugs are often used to terminate or prevent recurrent episodes and Type II (beta-blockers) and Type IV (calcium channel blockers) can be used to control the ventricular rate during atrial flutter. However, antiarrhythmic drugs alone control atrial flutter in only 50% to 60% of patients. Since the early 1990s, radiofrequency catheter ablation has been used to interrupt the reentrant circuit and prevent recurrences of atrial flutter. Radiofrequency ablation is acutely successful in over 90% of cases and avoids the long-term toxicity seen with antiarrhythmic drugs. Advanced mapping techniques and newer methods of delivering the radiofrequency lesions are being used to delineate unusual forms of atrial flutter and to minimize fluoroscopic exposure during the procedure.

Anti-Arrhythmia Agents↗

Potassium efflux from myocardial cells induced by defibrillator shock.

A transient, dose-dependent cardiac depression was produced by defibrillator shocks in an isolated, working canine heart preparation perfused with oxygenated arterial blood from a support dog. Accompanying this depression was an efflux of potassium (K+), forced out of the myocardial cells by the passage of defibrillating current. The transient increase in extracellular K+ concentration was recorded graphically in the venous outflow. It was found that 5-msec rectangular wave shocks, from three to ten times defibrillatory current threshold, released dose-related pulses of K+. It is concluded that because K+ is a myocardial depressant, at least part of the myocardial depression after defibrillation is caused by the release of K+ from the myocardial cells.

Animals↗

Direct activation of cardiac adrenergic nerve endings by defibrillator shocks.

Defibrillator shocks ranging in intensity from three to nine times current threshold were delivered to four isolated, metabolically supported, beating canine hearts. The shocks produced an immediate, current-dependent depression of left ventricular isovolumic systolic pressure. This depression was transient, reproducible, and was followed by a transient overshoot in ventricular systolic pressure. Then 1 mg propranolol hydrochloride in 1 ml H2O was injected into the coronary arterial supply of the isolated heart, and the shocks were repeated. The magnitude of the immediate cardiac depression after shock was unchanged; however, the time required for full recovery of left ventricular systolic pressure to a pre-shock control value was prolonged. In addition, the transient overshoot in ventricular systolic pressure seen in the untreated state was absent. These results are consistent with the hypothesis that defibrillatory shocks produce a direct activation of cardiac adrenergic nerves, which aid in recovery of ventricular contractility following defibrillator shocks.

Adrenergic Fibers↗