Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs.

In 20 patients undergoing hybrid total hip arthroplasty, the reproducibility and accuracy of templating using digital radiographs were assessed. Digital images were manipulated using either a ten-pence coin as a marker to scale for magnification, or two digital-line methods using computer software. On-screen images were templated with standard acetate templates and compared with templating performed on hard-copy digital prints. The digital-line methods were the least reliable and accuracy of sizing compared with the inserted prostheses varied between -1.6% and +10.2%. The hard-copy radiographs showed better reproducibility than the ten-pence coin method, but were less accurate with 3.7% undersizing. The ten-pence coin method was the most accurate, with no significant differences for offset or acetabulum, and undersizing of only 0.9%. On-screen templating of digital radiographs with standard acetate templates is accurate and reproducible if a radiopaque marker such as a ten-pence coin is included when the original radiograph is taken.

Acetabulum↗

The novel use of resorbable Vicryl mesh for in vivo tendon reconstruction to a metal prosthesis.

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure. Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres.

Animals↗

Ionising radiation exposure to orthopaedic trainees: the effect of sub-specialty training.

INTRODUCTION: We monitored image intensifier use by orthopaedic trainees to assess their exposure to ionising radiation and to investigate the influence of sub-specialty training. MATERIALS AND METHODS: Five different orthopaedic registrars recorded their monthly image intensifier screening times and exposure doses for all cases (trauma and elective), for a combined total of 12 non-consecutive months. Radiation exposure was monitored using shoulder and waist film badges worn both by surgeons and radiographers screening their cases. RESULTS: Registrars in spinal sub-specialties were exposed to significantly higher doses per case and cumulative doses per month than non-spinal trainees (P < 0.05), but significantly lower screening times per case (P < 0.05). There were no significant differences in cumulative screening times per month (P > 0.05). Regression analysis for all surgeons showed a significant relationship between shoulder film badge reading and cumulative dose exposed per month (P < 0.05), but not for cumulative screening time. Shoulder film badge recordings were significantly higher for spinal compared with non-spinal registrars (P < 0.05), although all badges were below the level for radiation reporting. Only one radiographer badge recorded a dose above threshold. CONCLUSIONS: Whilst the long-term effects of sub-reporting doses of radiation are not fully understood, we consider that this study demonstrates that trainees should not be complacent in accepting inadequate radiation protection. The higher doses encountered with spinal imaging means that sub-specialty trainees should be alerted to the risk of their increased exposure. The principle of minimising radiation exposure must be maintained by all trainees at all times.

Film Dosimetry↗

Extensor mechanism reconstruction after proximal tibial replacement.

We developed an in vivo model of the attachment of a patellar tendon to a metal implant to simulate the reconstruction of an extensor mechanism after replacement of the proximal tibia. In 24 ewes, the patellar tendon was attached to a hydroxyapatite (HA)-coated titanium prosthesis. In 12, the interface was augmented with autograft containing cancellous bone and marrow. In the remaining ewes, the interface was not grafted. Kinematic gait analysis showed nearly normal function of the joint by 12 weeks. Force-plate assessment showed a significant increase in functional weight-bearing in the grafted animals (p = 0.043). The tendon-implant interface showed that without graft, encapsulation of fibrous tissue occurred. With autograft, a developing tendon-bone-HA-implant interface was observed at six weeks and by 12 weeks a layered tendon-fibrocartilage-bone interface was seen which was similar to a direct-type enthesis. With stable mechanical fixation, an appropriate bioactive surface and biological augmentation the development of a functional tendon-implant interface can be achieved.

Animals↗

A histomorphological study of tendon reconstruction to a hydroxyapatite-coated implant: regeneration of a neo-enthesis in vivo.

The attachment of tendons and ligaments to massive endoprostheses remains a clinical challenge due to the difficulty in achieving a soft tissue implant interface with a mechanical strength sufficient to transmit the forces necessary for locomotion. We have used an in vivo animal model to study patellar tendon attachment to an implant surface. The interface generated when the patellar tendon was attached to a hydroxyapatite (HA) coated implant was examined using light microscopy and a quantitative histomorphological analysis was performed. In the Autograft Group, the interface was augmented with autogenous cancellous bone and marrow graft, and at six weeks an indirect-like insertion was observed. At twelve weeks, the interface was observed to be a layered neo-enthesis, whose morphology was similar to a normal direct tendon insertion. In the HA Group, the tendon-implant interface was not augmented, and the implant was enveloped by a dense collagenous fibrous tissue. This study shows that a tendon-implant neo-enthesis can develop in situ by employing a suitable implant surface in association with biological augmentation.

Animals↗