PubMed Health⌕ Search

Biomedical subjects

M J Peake

Publications and source records attributed to M J Peake.

29 records · Page 2Linked to original sources

Theoretical constraints in the measurement of serum bilirubin binding capacity.

The large majority of methods for measuring serum unoccupied bilirubin binding capacity involve adding an exogenous ligand to a diluted serum sample. If the added ligand binds specifically to bilirubin binding sites, the extrapolation is made that the amount of ligand which becomes bound represents the previously unoccupied bilirubin binding capacity of the original sample. This simple theory ignores the labile nature of the equilibrium reactions between bilirubin binding sites and the ligands with which they interact. The present theoretical and experimental study of these equilibrium reactions shows that (a) sample dilution alone results in changes in the proportional occupancy of bilirubin binding sites by bilirubin and other endogenous ligands, so that the extent of vacancy of those binding sites becomes exaggerated; (b) addition of an exogenous ligand to the diluted sample results is further displacement of native bilirubin and other endogenous ligands from bilirubin binding sites. The amount of added ligand which becomes bound is thus likely to represent a greater extent of vacancy of bilirubin binding sites than was present in the original sample. Results from such methods can therefore only overestimate the unoccupied bilirubin binding capacity of blood plasma in vivo. In order to avoid these analytical problems, current methods must be redesigned. It is suggested from this work that the ability of a serum to sequester safety additional bilirubin may best be assessed from measurement of its bilirubin buffering capacity. This parameter is different from the total or unoccupied binding capacity currently attempted, and its measurement is within the capability of published methods for measuring free (= unbound) bilirubin, modified to analyse minimally diluted samples.

Bilirubin↗

Comparison of standardization techniques for colorimetric analyses on a centrifugal analyzer.

The influences of the mode of standardization and the type of standard on the precision of four mechanized methods performed on a centrifugal analyzer are described. Experimental results show that the mode of standardization -- variable, using a standard in each analytical batch, and constant, using a direct relationship between concentration and absorbance -- must be objectively selected. If the variable mode is chosen, the type and level of standard must be carefully chosen and absorbance of assays of the standard must be carefully monitored for good quality control. It is recommended that the optimum standardization technique and standard, where applicable, should be assessed and subsequently documented in evaluations of methods, kits and instruments.

Centrifugation↗

Comparison of standardization techniques for manual colorimetric analyses.

The influence of both the mode of standardization and the type of standard on the precision of four manual colorimetric methods performed under optimal conditions variance is described. The terms variable calibration mode and constant calibration mode are proposed; these describe standardization by within-run standards and standardization by a predetermined calibration relationship between concentration and absorbance that remains constant over a fixed period of time. We show that calibration relationships and mode of standardization must be established for each and every individual method on objective evidence. Where within-run standards are used, they must be carefully selected for each method. The implications for method evaluation and quality control are discussed.

Blood Glucose↗

Problems associated with clinical chemistry quality control materials.

Quality control methods and materials are widely used to monitor each and every facet of clinical chemistry laboratory performance. Quality control materials are also used in evaluation of methods and as secondary standards. A wide range of liquid and lyophilized materials are available from commercial sources and are prepared in individual laboratories. Many problems arise in the use of quality control materials. Problems discussed in this review include the use of nonhuman based materials and additives of animal origin, the physical and chemical characteristics of quality control materials that differentiate such samples from those from patients, attempts to generate quality control materials with elevated levels of particular analytes, the difficulties in handling and storage of quality control materials, the dangers of hepatitis, and the stability of quality control materials both during storage in the laboratory and after their reconstitution. The advantages and disadvantages of liquid and lyophilized quality control materials are discussed. The assignation of analyte values is of particular importance as the current trend is to consider inaccuracy of laboratory methods in addition to imprecision. This review assesses relevant publications in an area of fundamental importance to quality control in clinical chemistry.

Animals↗

Rapid cholesterol measurement: patient classification in heart risk evaluation clinics.

Plasma cholesterol levels of patients attending a heart risk evaluation clinic were measured both in the clinic at the time of attendance, and later in a reference laboratory. The workflow of evaluation clinics may be improved, and patient satisfaction enhanced, by in situ measurement, since more than 60% of patients can be given a complete risk score at the time of attendance.

Cholesterol↗

Assessment of the Beckman oxygen rate analyzer for the enzymatic assay of cholesterol.

We describe an evaluation of the Beckman oxygen rate analyzer for the determination of cholesterol. The precision and accuracy obtained did not fulfill the short-term criteria of the Center for Disease Control but the precision met the criteria of the College of American Pathologist for analysis of cholesterol in screening programs. Good overall correlation between the oxygen rate method and a continuous-flow method with prior extraction was found for patient samples. The results obtained by the oxygen rate method had net positive bias up to the limit of linearity of 8.6 mmol cholesterol/liter. The instrument is not recommended for laboratory or epidemiological studies but may prove useful in screening programs.

Autoanalysis↗

Evaluation of a kit for the colorimetric determination of inorganic phosphate.

An evaluation of a colorimetric kit method for the determination of inorganic phosphate (Pierce Phosphorus Auto/Stat Kit) is described. The within-batch and between-batch precisions were shown to fulfil current criteria, and recovery experiments, linearity studies, analyses of quality control materials, and studies of possible interfering substances evidenced good accuracy. Comparison of the results obtained on samples from patients with those obtained by the vanadate/molybdate continuous-flow method showed that the test method had a comparative positive bias. The use of a calibration reference serum as standard is recommended. The kit method is technically simple, requiring no protein precipitation, and analyses can be performed rapidly.

Colorimetry↗

Manual and centrifugal analyzer determination of cholesterol and triglycerides with single-vial enzymatic reagents.

We have assessed Calbiochem single-vial enzymatic reagent systems for the analysis for cholesterol and triglycerides, using manual and centrifugal analyzer techniques. Analysis for cholesterol by both techniques had acceptable performance by the short-term criteria of the Center for Disease Control (CDC) during this study carried out under optimal conditions of variance. Analysis for triglycerides by the manual technique did not meet CDC criteria, and we do not recommend use of this method. Analysis for triglycerides by the centrifugal analyzer technique had acceptable short-term precision but had unacceptable accuracy at high concentrations of triglycerides; this method may be considered to have acceptable performance for routine laboratory use.

Centrifugation↗

Effectiveness of an outpatient urine screening program.

We evaluated the effectiveness of a routine outpatient urinalysis screening program on a sample population of 2600 patients. The 189 abnormal urine results found in 182 patients were followed up by study of any new clinical and laboratory investigations or therapeutic modifications initiated on the basis of any abnormal test result. The urinalysis screening program appeared to have significant bearing on diagnosis or treatment in only 13 patients. Abnormalities found in 150 of the 182 patients were either not noted or no further positive action was taken. Thus we concluded that under the conditions of this study the urine screening program added to hospital costs without significant benefit to the patient.

Bilirubin↗

Urinalysis by use of multi-test reagent strips: two dipsticks compared.

We compared Ames' "N-Multistix" with Boehringer's "Combur-8" ("Chemstrip-8") multi-test urine reagent strips by analysis of contrived urine specimens, testing accuracy, precision, specificity, and limits of detection of both products. Relative cost and ease of use were also examined. Each brand of urinary dipstick had specific advantages but it is unlikely that patient care would be adversely affected by preferential use of either product.

Acetoacetates↗