PubMed Health⌕ Search

Biomedical subjects

M J Spittal

Publications and source records attributed to M J Spittal.

14 recordsLinked to original sources

The recognition of critical incidents: quantification of monitor effectiveness.

We have conducted a prospective analysis of all reported critical incidents which occurred during the period from admission to the anaesthetic room until discharge from the operating theatre complex over a 1-year. The aim was to identify which monitors were most effective for initial recognition of those incidents. All patients were monitored in accordance with the recommendations of the procedures gave rise to 338 recorded critical incidents, of which 27 were deemed to have caused, or been likely to cause, patient harm. We have shown that a combination of arterial blood pressure measurement (noninvasive), ECG, pulse oximetry and clinical observation detected 90% of all reported critical incidents, and all the incidents causing patient harm. We have also shown that blood pressure monitoring by itself, and combination with ECG and pulse oximetry, detected proportionately more critical incidents resulting in patient harm (incidents resulting in harm remaining incidents, for each monitor) than clinical observation alone (p < 0.05) and all other remaining forms of monitoring together (p < 0.01).

Blood Pressure Determination↗

Rocuronium pretreatment reduces suxamethonium-induced myalgia: comparison with vecuronium.

We have studied, in 150 patients undergoing elective oral surgery, the effectiveness and sequelae of pretreatment with rocuronium for reducing myalgia after suxamethonium. Patients were allocated randomly to one of three groups: anaesthesia was induced with propofol and fentanyl, and group V received vecuronium 1 mg, group R rocuronium 6 mg and group P placebo pretreatment. Suxamethonium 1.5 mg kg-1 was given 60 s after the pretreatment agent. All patients received ketorolac 10 mg i.v. and morphine 10 mg i.m. for analgesia. The incidence of postoperative myalgia on day 1 after rocuronium (20%) was significantly less than after vecuronium (42%) (P < 0.05) or placebo (70%) (P < 0.01). By day 4 the incidence of myalgia was 28.6% in the rocuronium group, 46.3% in the vecuronium group and 95% in the placebo group. Intubating conditions were not affected adversely by any pretreatment regimen.

Adolescent↗

A prospective analysis of critical incidents attributable to anaesthesia.

The purpose of the study was an accurate and comprehensive prospective analysis of all untoward anaesthetic events and their sequelae, within a general hospital over a period of 1 year. We identified five system sets into which each of these critical incidents could be categorised. We also recorded data pertaining to the severity of the disturbance or event, the monitor that first identified the problem and the affect, if any, of the incident upon the patient. We found a critical incident rate of 6.68%, or one in 15 anaesthetic procedures performed. By far the majority of incidents were rapidly detected and effectively managed, with a morbidity rate of only 0.53%. The application of minimum monitoring standards was strongly reinforced. The presence of an anaesthetist throughout the period of the whole anaesthetic was shown to be the most effective component of these standards. The audit identified a trend for junior anaesthetists in particular to have a higher incidence of problems with the airway and circulation and for these to be associated with increased morbidity. This prompted revised supervision and training strategies for our junior anaesthetists.

Anesthesia↗

Evaluation of pulse oximetry during cardiopulmonary resuscitation.

This study evaluates whether the pulse oximeter is useful during cardiopulmonary resuscitation. The instrument was of undoubted benefit in the management of primary respiratory arrest, but of equivocable value in cardiac arrest. Data were displayed during external chest compressions, but were generally unreliable. The ear probe was not able to produce a consistently good signal during cardiopulmonary resuscitation. Nevertheless, the provision of an oximeter amongst the first-line resuscitation equipment available at a cardiopulmonary arrest significantly altered the management of seven out of 20 patients, five of whom survived.

Cardiopulmonary Resuscitation↗

The pneuPAC hyperbaric variant HB: a ventilator suitable for use within a one-man hyperbaric chamber.

We describe the performance of the pneuPAC hyperbaric variant HB, a ventilator designed for use in a one-man hyperbaric chamber. The ventilator delivered minute volumes of 11-23 litre at 1 atm abs to 7.6-16 litre at 2.5 atm abs. The delivered minute volume may be controlled easily from outside the chamber by manipulation of the ventilator rate, 11.5-31 b.p.m.

Evaluation Studies as Topic↗

Under pressure.

Explore the source record for details and available documents.

Adult↗