PubMed Health⌕ Search

Biomedical subjects

M J Tanasijevic

Publications and source records attributed to M J Tanasijevic.

At least 19 recordsLinked to original sources

Myoglobin levels at 12 hours identify patients at low risk for 30-day mortality after thrombolysis in acute myocardial infarction: a Thrombolysis in Myocardial Infarction 10B substudy.

OBJECTIVE: We sought to identify, by use of serum cardiac markers, patients at low risk for 30-day mortality after ST-segment elevation myocardial infarction. BACKGROUND: Baseline cardiac markers are currently used to identify patients at increased risk for short-term events. We hypothesized that serum markers measured after treatment could identify patients at low risk for 30-day mortality. METHODS: A total of 839 patients from the Thrombolysis in Myocardial Infarction (TIMI) 10B study had myoglobin, cardiac-specific troponin-I, creatine kinase (CK)-MB measurements at the following time points; baseline, 90 minutes, and 3 and 12 hours after thrombolysis. By use of receiver operating characteristic analysis, thresholds were derived to predict 30-day mortality with at least 95% negative predictive value. RESULTS: Ninety minutes after thrombolysis myoglobin was superior to troponin-I or CK-MB in identifying patients at low risk for mortality. The 30-day mortality for 12-hour myoglobin < or = 239 ng/mL was 1.4% compared with 9.1% for levels > 239 ng/mL (P < .001). For 12-hour troponin-I (threshold 81.5 ng/mL), mortality was 1.9% versus 6.6% (P = .001) if above threshold; similarly for CK-MB at 12 hours (threshold 191 ng/mL) it was 3.3% versus 7.9% (P = .02). Multivariate analysis of baseline and posttreatment cardiac markers, age, sex, infarct artery location, and 90-minute TIMI flow grade identified only 12-hour myoglobin among the cardiac markers as independently predicting a low 30-day mortality (odds ratio 0.11, 95% confidence interval 0.02-0.50, P < .004). CONCLUSION: Serum cardiac markers can identify greater than two thirds of patients at low risk for 30-day mortality. A low 12-hour myoglobin level (< or = 239 ng/mL in this substudy) identifies such patients at low risk and could potentially assist in early risk stratification and triage after ST-segment elevation myocardial infarction.

Aged↗

Differences in TDx fetal lung maturity assay values between twin and singleton gestations.

OBJECTIVE: The purpose of this study was to quantify differences in indexes of pulmonary maturity between singleton and twin gestations by means of the TDx fetal lung maturity assay. STUDY DESIGN: We identified records of a total of 830 singleton and twin pregnancies not complicated by diabetes and delivered between 28 and 37 weeks' gestation from December 1994 through August 1995. Among these, 170 (20%) had TDx fetal lung maturity measurements performed within 72 hours of delivery. Linear regression was used to assess differences in TDx fetal lung maturity assay values between singleton gestations (n = 143 gestations) and twin gestations (n = 27 gestations) while controlling for potential confounding factors. RESULTS: Twin gestations were no more likely than singleton gestations to undergo TDx fetal lung maturity screening (odds ratio, 1.3; 95% confidence interval, 0.8-2.2). Pregnancy complications and corticosteroid treatment were similar in the two groups. After 31 weeks' gestation the twin gestations had significantly higher TDx fetal lung maturity values. Linear regression with controls for gestational age indicated that twin gestations on average had a TDx fetal lung maturity value that was 22.0 mg/g (95% confidence interval, 9.8-34.6 mg/g) higher than that of gestational age-matched singleton gestations. CONCLUSION: Beyond 31 weeks' gestation twin pregnancies appeared to have a TDx fetal lung maturity value that was 22 mg/g higher than that of singleton pregnancies. If the underlying incidences of respiratory distress syndrome are similar between twin and singleton gestations, then the potential exists for false-positive prediction of adequate lung maturity values among twin gestations.

Adrenal Cortex Hormones↗

Comparison of disaturated phosphatidylcholine and fetal lung maturity surfactant/albumin ratio in diabetic and nondiabetic pregnancies.

We studied fetal lung maturity (FLM) by the amniotic fluid surfactant/albumin (FLM S/A) ratio and the disaturated phosphatidylcholine (DSPC) amniotic fluid levels at different gestational ages in diabetic (179 women with type 1 diabetes mellitus antedating pregnancy; infants delivered within 72 hours after amniotic fluid testing for DSPC level and FLM S/A ratio) and nondiabetic pregnancies (2 independent nondiabetic groups, 300 for FLM S/A ratio and 1,231 for DSPC level). The degree of maternal glycemia during gestation was estimated by serial measurements of hemoglobin A1. Multiple regression analyses, including gestational age (GAs) and diabetic status as independent variables and FLM S/A ratio and DSPC level as dependent variables, revealed significant effect from diabetic status and GA for FLM S/A ratio and a significant effect from GA but not from diabetic status for DSPC level. Glucose levels were controlled adequately throughout gestation as reflected by mean total glycated hemoglobin levels. Amniotic fluid levels of DSPC, the major surface tension-lowering component of pulmonary surfactant, are not significantly different between diabetic and nondiabetic pregnancies at different GAs.

Albumins↗

Appropriateness of prostate-specific antigen testing.

We established criteria for appropriate use of the prostate-specific antigen (PSA) assay and used them to evaluate PSA test utilization at 1 tertiary care institution. During a 6-month period, 2,330 PSA results were reported for outpatients and 95 for inpatients. We reviewed medical records for a random sample of 338 outpatient results (14.51%) and all 95 inpatient results, of which 21% (71/338) of outpatient and 17% (16/95) of inpatient results were inappropriate according to our test utilization criteria. Among outpatients, 52% of tests were done for screening and 19% for monitoring for cancer recurrence. For inpatients, workup for cancer (53/95 [56%]) was the most frequent indication for testing and screening the second (24/95 [25%]). Of tests failing the criteria, 66 (76%) of 87 resulted from excessively frequent and age-inappropriate screening. We assessed the potential effect on clinical outcome if these tests were not performed. Of the 87 tests considered inappropriate, only 1 test result influenced clinical management for patients younger than 75 years. By instituting simple limits on age and frequency, we estimate that 74% (64/87) of the inappropriate tests could have been eliminated.

Adult↗

Clinical efficacy of three assays for cardiac troponin I for risk stratification in acute coronary syndromes: a Thrombolysis In Myocardial Infarction (TIMI) 11B Substudy.

BACKGROUND: Significant analytic variability exists between the multiple assays for cardiac troponin I (cTnI) approved for clinical use. Until adequate cTnI standardization is possible, an evidence-based approach evaluating each assay at specific thresholds appears warranted. METHODS: We examined the efficacy of three cTnI assays for predicting death, myocardial infarction (MI), or the composite of death, MI, or urgent revascularization at 43 days among patients with non-ST-elevation acute coronary syndromes enrolled in the Thrombolysis In Myocardial Infarction (TIMI) 11B study. RESULTS: Six hundred eighty-one patients with serum samples obtained at baseline and/or 12-24 h had cTnI determined using all three assays. Baseline cTnI was > or = 0.1 microg/L for 368, 395, and 418 patients with the Bayer Immuno 1(TM), ACS:180, and Dimension RxL assays, respectively. Correlation coefficients for the RxL with the ACS:180 and Bayer Immuno 1 results were 0.89 (P = 0.0001) and 0.87 (P = 0.0001), with a coefficient of 0.92 (P = 0.0001) for the ACS:180 and Bayer Immuno 1 assays. Patients with cTnI > or = 0.1 microg/L were at increased risk fo death or MI by 43 days (relative risk, 2.2-3.0; P <0.0006), regardless of the assay used. This prognostic capacity persisted among those with creatine kinase MB isoenzyme concentrations within the reference interval. Moreover, cTnI was the strongest multivariate predictor of death, MI, or urgent revascularization with adjusted odds ratios of 2.1-2.9 (P <0. 0006). CONCLUSION: This study demonstrates the prognostic efficacy of three independently developed cTnI assays at a threshold of 0.1 microg/L for the prediction of adverse clinical outcomes among patients with non-ST-elevation acute coronary syndromes.

Aged↗

Evaluating the appropriateness of digoxin level monitoring.

BACKGROUND: Digoxin level determinations can be useful clinically in patients receiving digoxin therapy but are sometimes misused. METHODS: Explicit appropriateness criteria were adapted from previously published criteria and revised using local expert opinion. They were then used to evaluate the appropriateness of random samples of inpatient and outpatient serum digoxin levels. Overall agreement between reviewers regarding appropriateness was good (K = 0.65). Patients in the study included 162 inpatients in whom 224 digoxin levels were measured and 117 outpatients in whom 130 digoxin levels were measured during a 6-month period. The main outcome measure was the proportion of digoxin levels with an appropriate indication. RESULTS: Among inpatient levels, only 16% (95% confidence intervals [CI], 11%-20%) were appropriate. Of the 189 digoxin levels considered inappropriate, only 26 (14%) had a result of 2.3 nmol/L or more (> or =1.8 ng/ mL). None of these levels resulted in an important change in therapy, and no patient had a toxic reaction to the therapy. Among inappropriate levels, daily routine monitoring accounted for 78%. Of the 130 outpatient levels, 52% (95% CI, 44%-61%) were appropriate. Of 62 inappropriate levels, only 4 (6%) had a result of 2.3 nmol/L or more (> or =1.8 ng/mL). One result led to a change in therapy, but none of the patients were believed to experience a toxic reaction. Among the inappropriate levels, 87% of patients underwent early routine monitoring before a steady state was achieved. CONCLUSIONS: A high proportion of digoxin levels were inappropriate, particularly among inpatients. In both groups, the primary reason tests were judged inappropriate was early routine monitoring. Few inappropriate tests resulted in important data. Interventions to improve the use of digoxin levels could potentially save substantial resources without missing important clinical results.

Aged↗

The role of cardiac troponin-I (cTnI) in risk stratification of patients with unstable coronary artery disease.

In patients with chest pain at rest but no ST-segment elevation on the electrocardiogram, the diagnoses of unstable angina and non-Q-wave myocardial infarction (MI) are usually considered together because they cannot be differentiated clinically or angiographically. Since the extent of myocardial necrosis is an important determinant of the risk of death, it is important to identify serum markers with which to predict prognosis, in order to initiate appropriate medical treatment and/or invasive procedures in these patients. Cardiac troponin-I (cTnI), one of the subunits of the troponin regulatory complex, binds to actin and inhibits interactions between actin and myosin. The presence of elevated cTnI in serum is a significant prognostic indicator in patients with unstable angina and non-Q wave MI. Its independent prognostic potential persists even after adjustment for independent baseline variables known to be significantly associated with an increased risk of cardiac events. The use of cTnI in the triage of patients with unstable coronary disease may identify those at greater risk for adverse cardiac events.

Aged↗

Myoglobin, creatine-kinase-MB and cardiac troponin-I 60-minute ratios predict infarct-related artery patency after thrombolysis for acute myocardial infarction: results from the Thrombolysis in Myocardial Infarction study (TIMI) 10B.

OBJECTIVES: We examined the diagnostic performance of serum myoglobin, creatine-kinase-MB (CK-MB) and cardiac troponin-I (cTnI) for predicting the infarct-related artery (IRA) patency in patients receiving TNK-tissue plasminogen activator (TNK-tPA) therapy for acute myocardial infarction (AMI) in the Thrombolysis in Myocardial Infarction (TIMI) 10B trial. BACKGROUND: A reliable noninvasive serum marker of IRA patency is desired to permit early identification of patients with a patent IRA after thrombolysis. METHODS: We measured myoglobin, CK-MB and cTnI concentrations in sera obtained just before thrombolysis (T0) and 60 min later (T60) in 442 patients given TNK-tPA and who underwent coronary angiography at 60 min. RESULTS: Angiography at 60 min showed a patent IRA (TIMI flow grade 2, 3) in 344 and occluded IRA (TIMI flow grade 0, 1) in 98 patients. The median serum T60 concentration, the ratio of the T60 and T0 serum concentration (60-min ratio) and the slope of increase over 60 min for each serum marker were significantly higher in patients with patent arteries compared with patients with occluded arteries. The area under the receiver-operating characteristic (ROC) curve for diagnosis of occlusion was 0.71, 0.70 and 0.71 for the 60-min ratio of myoglobin, cTnI and CKMB, respectively. The 60-min ratios of > or =4.0 for myoglobin, > or =3.3 for CK-MB and > or =2.0 for cTnI yielded a probability of patency of 90%, 88% and 87%, respectively. CONCLUSIONS: The diagnostic performance of serum myoglobin, CK-MB and cardiac troponin-I (cTnI) 60-min ratios was similar. The probability of a patent IRA was very high (90%) in patients with 60-min myoglobin ratio > or =4.0, and early invasive interventions to establish IRA patency may not be necessary in this group. Serum marker determinations at baseline and 60-min after thrombolysis may permit rapid triage of patients receiving thrombolytic therapy by ruling out IRA occlusion.

Aged↗

What proportion of common diagnostic tests appear redundant?

PURPOSE: To identify ancillary tests for which there are criteria defining the earliest interval at which a repeat test might be indicated, to determine how often each test is repeated earlier than these intervals and, if repeated, provides useful information. SUBJECTS AND METHODS: We performed a retrospective cohort study of 6,007 adults discharged from a large teaching hospital during a 3-month period in 1991. We measured the proportion of commonly performed diagnostic tests that were redundant, and their associated charges. RESULTS: Of the 6,007 patients discharged, 5,289 (88%) had at least one of 12 target tests performed. Overall, 78,798 of the target tests were performed during the study period, of which 22,237 (28%) were repeated earlier than test-specific predefined intervals. This percentage varied substantially by test (range, 2% to 62%). To assess how many early repeats were justified, we performed chart reviews in a random sample stratified by test. For two tests, nearly all the initial results in the sample were abnormal, and all repeats were considered justified. Of early repeats following a normal initial result for the remaining 10 tests, chart review found no clinical indication for 92%, and a weighted mean of 40% appeared redundant. Overall, 8.6% of these 10 tests appeared redundant; if these were not performed, the annual charge reductions would be $930,000 at our hospital, although the impact on costs would be much smaller. CONCLUSIONS: For some tests, an important proportion are repeated too early to provide useful clinical information. Most such tests might be eliminated using computerized reminder systems.

Adult↗

Does the computerized display of charges affect inpatient ancillary test utilization?

BACKGROUND: The computerized display of charges for ancillary tests in outpatients has been found to affect physician-ordering behavior, but this issue has not been studied in inpatients. OBJECTIVE: To assess whether the computerized display of charges for clinical laboratory or radiological tests affected physician-ordering behavior. PATIENTS AND METHODS: Two prospective controlled trials, randomized by patient, were performed. Each trial included all medical and surgical inpatients at 1 large teaching hospital during 4 and 7 months: 3536 intervention and 3554 control inpatients in the group with clinical laboratory tests, and 8728 intervention and 8653 control inpatients in the group with radiological tests. The intervention consisted of the computerized display of charges for tests at the time of ordering. MAIN OUTCOME MEASURES: The number of clinical laboratory and radiological tests ordered per admission and the charges for these tests. RESULTS: For the clinical laboratory tests, during a 4-month study period, patients in the intervention group had 4.5% fewer tests ordered, and the total charges for these tests were 4.2% lower, although neither difference was statistically significant. Compared with historical controls from the same 4-month period a year before, the charges for the tests per admission had decreased 13.3%, but the decrease was temporally correlated with a restriction of future ordering of tests, and not with the introduction of the display of charges. For the radiological tests, during a 7-month period, the intervention group had almost identical numbers of tests ordered and charges for these tests. CONCLUSIONS: The computerized display of charges had no statistically significant effect on the number of clinical laboratory tests or radiological procedures ordered or performed, although small trends were present for clinical laboratory tests. More intensive interventions may be needed to affect physician test utilization.

Computer Systems↗

Myoglobin, creatine kinase MB, and cardiac troponin-I to assess reperfusion after thrombolysis for acute myocardial infarction: results from TIMI 10A.

BACKGROUND: The availability of a reliable, noninvasive serum marker of reperfusion may permit early identification of patients with occlusion after thrombolysis who might benefit from further interventions. METHODS: We measured myoglobin, creatine kinase MB (CK-MB), and cardiac troponin-I (cTnI) concentrations in sera obtained just before thrombolysis (T0) and 60 minutes later (T60) in 30 patients given TNK-tPA for acute myocardial infarction as part of the Thrombolysis in Myocardial Infarction (TIMI) 10A trial. RESULTS: Angiography at T60 showed reperfusion (TIMI flow grade 2 to 3; n = 19) or occlusion (TIMI flow grade 0 to 1; n = 8). The median serum T60 concentration, the ratio of the T60 and T0 serum concentration, and the slope of increase over a 60-minute period for each serum marker were significantly higher in patients with patent arteries compared with patients with occluded arteries. The areas under the receiver operator characteristics curve for diagnosis of occlusion were 0.96, 0.91, and 0.87 for the T60 concentration of myoglobin, CK-MB and cTnI, respectively. Although the T60 levels of <469 ng/ml for myoglobin, <11.5 ng/ml for CK-MB, and < 1.1 ng/ml for cTnI identified all patients with occlusion, the specificity of myoglobin (94%) was higher than that of CK-MB (61%) and cTnI (67%). Similar results were obtained for the 60-minute ratios and 60-minute slopes for each marker, with indexes for myoglobin having the highest specificity. CONCLUSIONS: In this pilot study, noninvasive diagnosis of occlusion 60 minutes after thrombolysis was achieved with a high degree of sensitivity and specificity with the myoglobin, CK-MB, and cTnI concentrations measured at that time point. These preliminary findings may permit a new strategy for assessment of the success of reperfusion, with triage to rescue angioplasty for patients in whom the 60-minute cardiac marker values or indexes are consistent with occlusion of the infarct-related artery.

Adult↗

How fast is fast enough for clinical laboratory turnaround time? Measurement of the interval between result entry and inquiries for reports.

We measured the time interval from result entry by the clinical laboratory to inquiry for reports by clinicians as a proxy for the actual turnaround time required to meet current patient care needs and to determine whether different patterns of report inquiry occur among clinical departments. The study included 4,004 complete blood cell (CBC) count reports that were sought by the clinical services using the hospital information system. The median time to report inquiry was 90 minutes for routine inpatient tests, 35 minutes for stat inpatient tests, and 30 minutes for the stat outpatient CBC counts. Most reports (range, 86%-94%) from these three subgroups were requested within 4 hours from entry of the results in the hospital information system. Of the routine outpatient test reports, 14%, 23%, and 31% were requested within the first 2 hours, 4 hours, and 8 hours, respectively. Although the interdepartmental variations in the median time for report inquiry were statistically significant for routine inpatient tests, stat inpatient tests, and stat outpatient tests, inquiries for the preponderance of reports for all three groups were within the first 1.5 to 3 hours from entry of the results in the hospital information system. We conclude that the majority of CBC counts and other tests with effects on immediate patient care management must be performed very rapidly on site and cannot be moved off site without compromising current standards of medical practice.

Blood Cell Count↗

Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes.

BACKGROUND: In patients with acute coronary syndromes, it is desirable to identify a sensitive serum marker that is closely related to the degree of myocardial damage, provides prognostic information, and can be measured rapidly. We studied the prognostic value of cardiac troponin I levels in patients with unstable angina or non-Q-wave myocardial infarction. METHODS: In a multicenter study, blood specimens from 1404 symptomatic patients were analyzed for cardiac troponin I, a serum marker not detected in the blood of healthy persons. The relation between mortality at 42 days and the level of cardiac troponin I in the specimen obtained on enrollment was determined both before and after adjustment for baseline characteristics. RESULTS: The mortality rate at 42 days was significantly higher in the 573 patients with cardiac troponin I levels of at least 0.4 ng per milliliter (21 deaths, or 3.7 percent) than in the 831 patients with cardiac troponin I levels below 0.4 ng per milliliter (8 deaths, or 1.0 percent; P < 0.001). There were statistically significant increases in mortality with increasing levels of cardiac troponin I (P < 0.001). Each increase of 1 ng per milliliter in the cardiac troponin I level was associated with a significant increase (P = 0.03) in the risk ratio for death after adjustment for the base-line characteristics that were independently predictive of mortality (ST-segment depression and age > or = 65 years). CONCLUSIONS: In patients with acute coronary syndromes, cardiac troponin I levels provide useful prognostic information and permit the early identification of patients with an increased risk of death.

Acute Disease↗

Racial differences in the predictive value of the TDx fetal lung maturity assay.

OBJECTIVE: Black newborns have lower rates of neonatal respiratory distress syndrome compared with nonblack newborns. This has been attributed to accelerated lung maturation. Previous studies have demonstrated a difference in the predictive value of the lecithin/sphingomyelin ratio, a test for lung maturity, between races. Our study examines the predictive value of the newer TDx Fetal Lung Maturity Surfactant-to-Albumin assay. STUDY DESIGN: We reviewed the records of 393 nonblack and 87 black infants delivered within 72 hours of the TDx FLM S/A assay testing. We compared the rates of neonatal respiratory distress syndrome by race, stratified by results. RESULTS: In our study population black newborns had less than one half the rate of respiratory distress syndrome compared with nonblack newborns (4.6% vs 10.4%). To adjust for possible differences in the timing of lung maturation, the results were stratified by the TDx FLM S/A assay result. Black race had a protective effect (Mantel-Haenszel weighted odds ratio 0.30, 95% confidence interval 0.06 to 0.93, p < 0.05). This significant racial difference remained when both TDx FLM S/A assay result and gestational age were controlled in a multiple logistic regression analysis. CONCLUSIONS: There are differences in the predictive value of the TDx FLM S/A assay among races. Black fetuses are less likely to have respiratory distress syndrome. The difference in rates of respiratory distress syndrome between races must be due to either a qualitative difference in the surfactant or to an anatomic difference in fetal lungs. Consideration should be given to a lower cutoff value for a mature test result in black women.

Black People↗

Prediction of fetal lung maturity in infants of diabetic mothers using the FLM S/A and disaturated phosphatidylcholine tests.

The authors evaluated the performance of the amniotic fluid surfactant to albumin ratio (FLM S/A), and disaturated phosphatidylcholine (DSPC) tests in assessing fetal lung maturity in infants of mothers with insulin-dependent diabetes mellitus antedating pregnancy. The distribution of the study population (n = 180) by class of diabetes was class B (27%); class C (28%); class D (29%); class F, FR and T (8%); and class R patients (8%). The diagnosis of respiratory distress syndrome (RDS) was the standard for evaluating the performance of FLM S/A and DSPC. The mean estimated gestational age was 37.4 weeks. Three infants (1.7%) were diagnosed with RDS. All three were delivered before 36 weeks. FLM S/A at the cut-off for "maturity" of > or = 70 mg/g, had a sensitivity of 66.6%, specificity of 94.9%, positive predictive value (PPV) of 18.2%, and negative predictive value (NPV) of 99.4%. DSPC at the cut-off for "maturity" of 1,000 micrograms/dL, had identical sensitivity and NPV, but lower specificity (89.2%) and PPV (9.5%) than FLM S/A. Both tests mispredicted maturity in the same case of RDS. The false "mature" rate of FLM S/A was 0.6% (95% confidence interval 0.0%-3.2%). The FLM S/A result of > or = 70 mg/g, obtained at or near-term, is a reliable predictor of the absence of RDS in infants of mothers with diabetes mellitus antedating pregnancy.

Albumins↗