Plaque and structural characteristics of the descending thoracic aorta using transesophageal echocardiography.

The in vivo acoustic and structural characteristics of atherosclerosis in the descending thoracic aorta have not been well delineated. We prospectively evaluated the descending thoracic aorta of 147 patients (35 women and 112 men; age, 61 +/- 14 years) who underwent clinically indicated transesophageal echocardiography. Patients with suspected disease of the aorta were excluded. Thirty-eight patients (26%) had protruding plaques (men, 25%; women, 29%). Six patients had mobile intimal densities with the mobile area ranging up to 1 cm2. As expected, aortic lumen area was decreased (plaque-free, 3.53 cm2; plaque, 3.19 cm2; p less than 0.05) and wall area was increased (plaque-free, 1.51 cm2; plaque, 1.92 cm2; p less than 0.05) in the regions of the plaque. However, total arterial area was not increased (plaque-free, 5.04 cm2; plaque, 5.09 cm2; difference not significant) in a compensatory manner as observed in other arterial beds. Plaque gray scale was less than the gray scale of plaque-free wall (plaque-free, 141.2; plaque, 122.7; p less than 0.05) when compared at the same level of the descending thoracic aorta or with a second aortic plaque-free level (plaque-free, 150.4; plaque, 122.7; p less than 0.05). Standard deviation of gray scale level was similar between plaque and normal regions. Unsuspected protruding plaques in the descending thoracic aorta occurred in one quarter of the patients referred for routine transesophageal examination. Plaques tended to have lower echogenicity and were differentiated from plaque-free walls within patients. Plaque formation did not result in increased total arterial area. These data suggest that the degree or character of compensatory atherosclerotic remodeling in the highly elastic descending thoracic aorta may differ from other arterial beds.

Aorta, Thoracic↗

Structural evaluation of porcine heart valve prostheses with radiofrequency ultrasound.

BACKGROUND: Bioprosthetic heart valve use is limited by progressive degeneration. Early degenerative changes are often occult, making assessment of tissue integrity difficult. Ultrasound tissue characterization may detect alterations in tissue structure and allow early detection of leaflet degeneration. METHODS: Using a modified echocardiographic unit (Acuson), radiofrequency (RF) integrated backscatter amplitude (IBA) (integral/RF/dt) was measured in 38 leaflets from nine explanted and six control porcine valves. Regions of interest in each leaflet were studied using four ultrasound frequencies. Radiographic gray scale mean and leaflet thickness were measured at each region of interest. Percent collagen and mineral were calculated for each region of interest using color-image processing of histologic sections and compared to IBA. RESULTS: IBA values for control vs. explanted leaflets were (mean value+/-standard deviation): 8.2+/-4.69 dB vs. -4.7+/-4.64 dB at 7.0 MHz; -5.8+/-4.34 dB vs. -3.1+/-5.34 dB at 5.0 MHz; -3.8+/-3.38 dB vs. -2.1+/-3.18 dB at 3.5 MHz; and -9.0+/-4.58 dB vs. -7.1+/-4.25 dB at 2.5 MHz. Collagen content was 27.7+/-8.50% vs. 33.2+/-10.90%, mineral content was 0.1+/-0.10% vs. 2.1+/-4.30%, and radiographic gray scale mean was 150.6+/-1.96 vs. 145.3+/-5.14 for control vs. explanted leaflets, respectively. For control and explanted leaflets IBA, collagen content, mineral content, and radiographic gray scale mean were different (control vs. explanted P<0.05). Leaflet thickness was also noted to be different between the two groups. IBA was different among explanted leaflets with low, medium, and high mineral content. CONCLUSION: IBA was found to be a useful technique to differentiate normal from explanted porcine prosthetic valves in vitro. This method may be useful in the serial assessment of bioprosthetic leaflet degenerative properties in vivo.

Adult↗

Confirmation and initial documentation of thoracic and abdominal aortic helical flow. An ultrasound study.

Aortic helical flow may play an important role in plaque deposition, dissection formation, and organ perfusion. The authors have previously demonstrated, using in vitro flow models and transesophageal echocardiography, that helical flow begins in the mammalian aortic arch and continues into the descending thoracic aorta. The purpose of this study was to confirm thoracic aortic helical flow and document its extent into the abdominal aorta using direct measurements. Twelve mongrel dogs underwent surgery with exposure of the abdominal aorta up to the diaphragm. Six of the 12 underwent further thoracotomy with thoracic aorta exposure. Color Doppler ultrasound images were obtained using a 5 megaHz esophageal transducer, hand held, directly applied, and visually aligned for transverse aortic imaging. Helical flow was considered present with the appearance of red/blue hemicircles during a systolic wave when the aorta was imaged transversely. All six dogs that had thoracotomy showed clockwise thoracic aortic helical flow (along the direction of blood flow) at the retro left ventricular region. In all dogs, clockwise helical flow was demonstrated to and immediately beyond the renal arteries. In 11 of 12 dogs, clockwise helical flow was demonstrated 7 cm below the renal arteries. The study confirms the presence of helical flow in the thoracic aorta and documents its extent into the abdominal aorta below the level of the renal arteries. The teleologic flow pattern of mammals may extend to other classes of vertebrates and must be accounted for in studies of endothelial shear and flow separation. In addition, tangential velocities imparted by helical flow may affect organ perfusion.

Animals↗

Cannulation of the aortic branches using ultrasound guidance. An animal study.

Catheter placement by ultrasound may reduce radiation, improve positioning, and allow the use of echo contrast agents for diagnostic and therapeutic procedures. To evaluate its utility in the peripheral and coronary vascular beds, a preshaped 20 MHz Doppler catheter was inserted into the femoral artery for renal artery, or into the right carotid artery for left coronary artery cannulation in five dogs. Ultrasonic imaging of the vascular structure and catheter was provided by either transabdominal or transesophageal ultrasound. Using Doppler waveform polarity for retrograde guidance, the catheter was advanced to the region of the left renal or left coronary ostia. Ultrasonic emissions from the Doppler catheter were identified by color Doppler mode of the ultrasound machine and allowed the catheter tip to be identified within the beam width of the scanning transducer, providing the depth dimension. In the two animals in which left renal artery cannulation was attempted, the catheter was successfully manipulated into the ostium. In two of the three animals in which left coronary artery cannulation was attempted, the catheter was successfully manipulated into the ostium, followed by saline contrast injections revealing myocardial perfusion. In addition, in one animal, a Doppler flow wire was identified as it was advanced into the mid circumflex coronary. In conclusion, ultrasonically guided cannulation of aortic branches may be possible without x-ray, and this technique may lead to further use of ultrasound in diagnostic and therapeutic procedures.

Animals↗