PubMed Health⌕ Search

Biomedical subjects

M J W Greuter

Publications and source records attributed to M J W Greuter.

2 recordsLinked to original sources

A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm.

A model is presented that describes the image quality of coronary arteries with multidetector computer tomography. The results are discussed in the context of rotation time of the scanner, heart rate, and number of sectors used in the acquisition process. The blurring of the coronary arteries was calculated for heart rates between 50 and 100 bpm for rotation times of 420, 370, and 330 ms, and one-, two-, three-, and four-sector acquisition modes and irregular coronary artery movement is included. The model predicts optimal timing within the RR cycle of 45+/-3% (RCA), 44+/-4% and 74+/-6% (LCX), and 35+/-4% and 76+/-5% (LAD). The optimal timing shows a negative linear dependency on heart rate and increases with the number of sectors used. The RCA blurring decreases from 0.98 cm for 420 ms, one-sector mode to 0.27 cm for 330 ms, four-sector mode. The corresponding values are 0.81 cm and 0.29 cm for LCX and 0.42 cm and 0.17 cm for LAD. The number of sectors used in a multisector reconstruction and the timing within the cardiac cycle should be adjusted to the specific coronary artery that has to be imaged. Irregular coronary artery movement of 1.5 mm justifies the statement that no more than two sectors should be used in multisector acquisition processes in order to improve temporal resolution in cardiac MDCT.

Algorithms↗

Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature.

Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.

Humans↗