PubMed Health⌕ Search

Biomedical subjects

M J Yzuel

Publications and source records attributed to M J Yzuel.

5 recordsLinked to original sources

Achromatic diffractive lens written onto a liquid crystal display.

We propose a programmable diffractive lens written onto a liquid crystal display (LCD) that is able to provide equal focal lengths for several wavelengths simultaneously. To achieve this goal it is necessary that the LCD operate in the phase-only regime simultaneously for the different wavelengths. We design the appropriate lens for each wavelength, and then the lenses are spatially multiplexed onto the LCD. Various multiplexing schemes have been analyzed, and the random scheme shows the best performance. We further show the possibility of finely tuning the chromaticity of the focal spot by changing the relative weights of the multiplexing among the various wavelengths.

Journal Article↗

Using mathematical morphology to determine left ventricular contours.

The aim of this study is to investigate the use of mathematical morphology for the determination of left ventricular contours in scintigraphic images using multigated radionuclide angiography. We have developed a completely automatic method that first restores the image with a Wiener filter, then finds the region where the left ventricle is contained, and finally segments the left ventricle contour and a background zone. The contours depend on the values of the parameters that appear in the mathematical morphology method, which are related to the height and the slope of the count distribution. Results obtained with this method are compared with the contours and the background zones outlined by experts on the basis of the number of counts. We study the values of the parameters with which the optimum correlation is obtained.

Humans↗

Evaluation of the response of a round hole scintillation camera collimator by the Fourier analysis method.

The Fourier analysis method was used to investigate the response of scintillation camera collimators with parallel holes. This method which takes into account the septal penetration was applied to the case of round hole collimators having a hexagonal distribution. Modulation transfer functions, MTF have been determined to verify the accuracy of the computed Fourier coefficients of the collimator function. Comparisons between the geometric and the penetrating plus geometric transfer function are shown for round and hexagonal holes.

Evaluation Studies as Topic↗

A study of the point spread function in scintillation camera collimators based on Fourier analysis.

A new technique for evaluating the point spread function of parallel hole collimators in scintillation cameras is studied. The collimator function is developed into a Fourier series and the intensity distribution in the detector plane for a point source is given by a mathematical expression that depends on the object position and on the collimator parameters. The septal penetration effect is considered. The technique is applied to obtain the general formulae for collimators with hexagonal holes and the PSF is evaluated.

Fourier Analysis↗