Distal radius: in vivo assessment with quantitative MR imaging, peripheral quantitative CT, and dual X-ray absorptiometry.

PURPOSE: To evaluate in vivo the relationship between magnetic resonance (MR) imaging relaxation time and bone mineral density (BMD) at the distal radius. MATERIALS AND METHODS: The 1/T2* MR imaging relaxation rates and dual X-ray absorptiometry (DXA) measurements were evaluated in the trabecular bone of the distal 5 cm of the radius in 14 healthy premenopausal women and 11 healthy postmenopausal women and in 11 women with osteoporosis. Trabecular and total BMD were measured with peripheral quantitative computed tomography (CT). RESULTS: In healthy women, 1/T2* values and trabecular BMD at peripheral quantitative CT were significantly correlated but 1/T2* and total BMD were not. Statistically significant (P = .03) correlations between 1/T2* and DXA were found only in the most distal area covered with DXA. The 1/T2* values were more closely correlated with age and showed higher relative annual decreases (0.47%-0.81%) than peripheral quantitative CT (0.20%-0.59%) or DXA (0.10%-0.39%). Pre- and postmenopausal healthy subjects could be distinguished only with MR imaging, and postmenopausal healthy and osteoporotic subjects only with CT and DXA. CONCLUSION: MR imaging relaxation rates correlate well with trabecular BMD in vivo.

Absorptiometry, Photon↗

Quantitative CT assessment of the lumbar spine and radius in patients with osteoporosis.

OBJECTIVE: We undertook this study to quantify the relationship between bone mineral assessments of the lumbar spine using quantitative CT (QCT) and of the radius using peripheral QCT (pQCT) and to test the sensitivity of both techniques in detecting changes in bone mass that are related to age and osteoporosis. SUBJECTS AND METHODS: Forty-two healthy premenopausal, 38 healthy postmenopausal, and 97 osteoporotic postmenopausal women were examined with pQCT of the distal radius and with QCT of the lumbar spine (L1-L4). The bone mineral density (BMD), bone mineral content (BMC), and a cross-sectional area of cortical bone were assessed at the distal radius. The BMD of trabecular and total bone and the BMC of total bone were assessed at the midvertebral bodies of the lumbar spine. RESULTS: In the healthy women, correlations of radial BMD with spinal trabecular and total BMD were modest (r = .39 and r = .49, respectively) but were higher for total BMC (r = .79). All correlations in osteoporotic women (r = .19 for trabecular BMD, r = .31 for total BMD, and r = .47 for total BMC) were lower than those in healthy women. For measurement of spinal bone mass in healthy women, trabecular BMD showed a higher correlation with age (r = .81) and a larger relative annual decrease (1.2%) than did total BMD (r = .75, .78%) or total BMC (r = .54, .55%). At the radius, the highest correlations with age were found for total BMC (r = .57, .53%), cortical area (r - .52, .67%), and cortical BMC (r = .48, .78%). Age-adjusted odds ratios for prevalent vertebral fractures were highest for total (4.5) and trabecular (4.4) spinal BMD. For radial measurements, odds ratios were highest for both total BMD (2.3) and cortical area (2.3). CONCLUSION: QCT of spinal trabecular bone showed the strongest capability for assessment of age-related bone loss and for discrimination of osteoporotic vertebral fractures. In comparison, pQCT of radial trabecular bone showed the weakest capability for these applications, and pQCT of radial cortical or total bone showed intermediate capability.

Aged↗

Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry.

To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are unaffected by height and weight and are more strongly associated with vertebral fracture than standard PA BMD or BMC, or estimates of volumetric density that are solely based on PA DXA scans.

Absorptiometry, Photon↗

Assessment of the skeletal status by peripheral quantitative computed tomography of the forearm: short-term precision in vivo and comparison to dual X-ray absorptiometry.

In order to assess precision of peripheral quantitative computed tomography (pQCT), duplicate bone mineral density (BMD) measurements at the radius were performed in 20 healthy premenopausal, 20 healthy postmenopausal, and 20 osteoporotic postmenopausal women using a Stratec XCT-960 system. The short-term reproductibility in vivo for the total, trabecular, and cortical regions of interest (ROI) was expressed as the absolute precision error (standard deviation, SD) and as the relative precision error (SD/mean x 100, or coefficient of variation, CV, in %). Reproducibility in vivo was good in all volunteers but was influenced by the study group and the ROI. The precision error for trabecular BMD was 3 mg/cm3, or about 1.6%. This is large relative to the aging decrease of 0.22%/year, or to the difference (12 mg/cm3, or 7%) between osteoporotic women and postmenopausal controls. In order to compare pQCT to dual X-ray absorptiometry (DXA) at the forearm and at the lumbar spine (L1-L4), 40 premenopausal healthy controls, 40 postmenopausal healthy controls, and 35 postmenopausal osteoporotic women were assessed. DXA measurements performed at the ultradistal, middistal, 1/3, and total ROI of the radius showed only moderate correlations between r = 0.38--0.75, r = 0.27--0.64, and r = 0.38--0.53 for the comparison versus pQCT total BMD, versus pQCT trabecular BMD, and versus pQCT cortical BMD, respectively. Correlations of DXA at the lumbar spine and pQCT were between r = 0.18 and 0.44. DXA at radius and spine was able to discriminate between post- menopausal controls and osteoporotic women (p = 0.001--.004),but BMD measurements by pQCT did not show this ability (p = 0.15--0.52). However, two nonstandard pQCT parameters, namely the surface area of the cortical bone and the cortical BMC were factors that discriminated well between these two groups (p = 0.002, p = 0.005, respectively). These pQCT parameters also yielded the highest relative annual changes in pre- and post-menopausal control subjects. The measurement of cortical bone in the distal radius proved to be a good predictor of vertebral fracture status and was a good indicator of age-related skeletal change. Our data emphasize the importance of cortical measurements when using pQCT of the radius to assess osteoporosis.

Absorptiometry, Photon↗

Hip and calcaneal bone loss increase with advancing age: longitudinal results from the study of osteoporotic fractures.

It is uncertain whether or how rapidly elderly women continue to lose bone with advancing age. To determine rates of change in bone mass at the hip and at the calcaneus in elderly women and to compare these rates of change among estrogen users and nonusers, we prospectively measured rates of change in bone mineral density (BMD) at the total hip and its four subregions (mean +/- SD, 3.55 +/- 0.29 years between examinations) and at the calcaneus (mean +/- SD, 5.69 +/- 0.33 years between examinations) in 5689 community-dwelling white women aged 65 years or older at the baseline examination. The rate of decline in total hip BMD steadily increased from 2.5 mg/cm 2/year (95% confidence interval 2.0 to 2.9) in women 67-69 years old to 10.4 mg/cm 2/year in those aged 85 or older (95% confidence interval 8.4 to 12.4). The rate of bone loss also increased with aging at all subregions of the hip and at the calcaneus. The average loss of bone from the total hip is sufficient to increase the risk of hip fracture by 21% per 5 years in women aged 80 years or older. Compared with nonusers, current estrogen users had a 33% lower age-adjusted mean rate of loss at the total hip (2.9 vs 4.3 mg/cm 2/year, p < or = 0.0001) and a 35% lower age-adjusted mean rate of loss at the calcaneus (3.9 vs 6.0 mg/cm 2/year, p < or = 0.0001). The rate of bone loss in the hip and calcaneus steadily increases with advancing age in older women. Estrogen therapy may significantly decrease this loss. Efforts to understand and prevent bone loss should include elderly women.

Aged↗

MRI of bone marrow in the distal radius: in vivo precision of effective transverse relaxation times.

The effective transverse relaxation time T2* is influenced by the presence of trabecular bone, and can potentially provide a measure of bone density as well as bone structure. We determined the in vivo precision of T2* in repeated bone marrow measurements. The T2* measurements of the bone marrow of the distal radius were performed twice within 2 weeks in six healthy young volunteers using a modified water-presaturated 3D Gradient-Recalled Acquisition at Steady State (GRASS) sequence with TE 7, 10, 12, 20, and 30; TR 67; flip angle (FA) 90 degrees. An axial volume covering a length of 5.6 cm in the distal radius was measured. Regions of interest (ROIs) were determined manually and consisted of the entire trabecular bone cross-section extending proximally from the radial subchondral endplate. Reproducibility of T2* and area measurements was expressed as the absolute precision error (standard deviation [SD] in ms or mm2) or as the relative precision error (SD/mean x 100, or coefficient of variation [CV] in %) between the two-point measurements. Short-term precision of T2* and area measurements varied depending on section thickness and location of the ROI in the distal radius. Absolute precision errors for T2* times were between 1.3 and 2.9 ms (relative precision errors 3.8-9.5 %) and for area measurements between 20 and 55 mm2 (relative precision errors 5.1-16.4%). This MR technique for quantitative assessment of trabecular bone density showed reasonable reproducibility in vivo and is a promising future tool for the assessment of osteoporosis.

Adult↗

Comparison of semiquantitative and quantitative techniques for the assessment of prevalent and incident vertebral fractures.

To compare visual semiquantitative (SQ) reading and quantitative morphometry (QM) for assessing prevalent and incident vertebral fractures, radiographs of the thoracolumbar spine were evaluated in 400 (only baseline films) and 335 (baseline and follow-up films) postmenopausal women with osteopenia as defined by a T-score of less than 2 SD below young normals. QM was performed using different cutoff thresholds, and the SQ reading was performed by three radiologists independently. A joint consensus reading of the radiographs by all participating radiologists was used as a reference standard. Our results indicate that the concordance within SQ methods is excellent, and it is higher than that between SQ and QM regardless of the cutoff criteria used. This finding was consistent for the diagnosis of prevalent as well as incident vertebral fractures. For prevalent fractures the use of the 2.5 SD cutoff criterion provided the highest concordance with the consensus reading and with the radiologists' reading, thereby providing high sensitivity (70.23%) with moderate specificity (98.76%) relative to the consensus reading when compared with the 3 SD or 4 SD cutoff criteria. For the diagnosis of incident vertebral fractures the best agreement between our consensus reading and QM was found for an absolute reduction of 6 mm and for a combination of relative and absolute reduction of 15% and 3 mm in vertebral height. The respective sensitivities and specificities for the two criteria were 51%/99.9% and 75.4%/98.9%, respectively. Even though the consensus reading may favor the reader's evaluation over QM, the assessment of prevalent and incident fractures using QM alone may not be sufficiently reliable for detection of vertebral fractures in epidemiological studies and clinical trials. It should be performed principally in conjunction with a trained radiologist or a highly experienced clinician.

Bone Diseases, Metabolic↗

Spinal bone mineral assessment in postmenopausal women: a comparison between dual X-ray absorptiometry and quantitative computed tomography.

We compared quantitative computed tomography (QCT) and dual X-ray absorptiometry (DXA) with respect to their ability to discriminate subjects with and without prevalent vertebral fractures. In 240 post-menopausal women (mean age 63.7 +/- 6.9 years) lateral spine radiographs (T4-L4) were reviewed for the presence of vertebral fracture. Using a semiquantitative technique to grade the severity of vertebral deformities, we classified fractures as mild, moderate or severe (grade 1 to 3, respectively). Postero-anterior DXA (PA-DXA) and lateral DXA (L-DXA) measurements (L2-4) as well as QCT measurements of the lumbar spine (T12-L3 or L1-14) were obtained in all women. Seventy-two women were diagnosed with at least one fracture, and of these 40 were graded as mild. Comparing normal women with fractured women, we found the area under the receiver operating characteristics (ROC) curves to be greatest for QCT (0.81), followed by L-DXA (0.72) and PA-DXA (0.65). The differences among all three techniques were significant. Comparing the normal women with women having only mild fractures, the areas under the ROC curves were 0.79, 0.73 and 0.63 for QCT, L-DXA and PA-DXA, respectively. Significant differences existed between QCT and PA-DXA as well as between L-DXA and PA-DXA. Logistic regression analysis also revealed the highest age-adjusted odds ratios for QCT (3.67; 2.25-5.97) while L-DXA and PA-DXA showed substantially lower odds ratios (2.00; 1.39-2.87, and 1.54; 1.11-2.15, respectively). We conclude that low bone density as measured by QCT, PA-DXA or L-DXA is significantly associated with the prevalence of vertebral fractures. Of the methods studied, QCT of trabecular bone offered the best discriminatory capability. L-DXA proved to be superior to PA-DXA in its diagnostic sensitivity, particularly in women with mild fracture. Mild vertebral fractures are associated with decreased spinal bone density and may be regarded as osteoporotic deformities.

Absorptiometry, Photon↗

Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques.

Assessment of precision errors in bone mineral densitometry is important for characterization of a technique's ability to detect longitudinal skeletal changes. Short-term and long-term precision errors should be calculated as root-mean-square (RMS) averages of standard deviations of repeated measurements (SD) and standard errors of the estimate of changes in bone density with time (SEE), respectively. Inadequate adjustment for degrees of freedom and use of arithmetic means instead of RMS averages may cause underestimation of true imprecision by up to 41% and 25% (for duplicate measurements), respectively. Calculation of confidence intervals of precision errors based on the number of repeated measurements and the number of subjects assessed serves to characterize limitations of precision error assessments. Provided that precision error are comparable across subjects, examinations with a total of 27 degrees of freedom result in an upper 90% confidence limit of +30% of the mean precision error, a level considered sufficient for characterizing technique imprecision. We recommend three (or four) repeated measurements per individual in a subject group of at least 14 individuals to characterize short-term (or long-term) precision of a technique.

Absorptiometry, Photon↗

Which vertebrae should be assessed using lateral dual-energy X-ray absorptiometry of the lumbar spine.

The purpose of this study was to determine precision and diagnostic capability of bone mineral density measurements using lateral dual-energy X-ray absorptiometry (DXA) of the lumbar spine in supine position. Duplicate postero-anterior (PA) and lateral DXA measurements were performed in 60 women. Precision errors of the single vertebral levels using lateral DXA ranged from 3.3% to 4.9%. The combination of all levels improved the precision errors to 2.0%. Paired PA and lateral DXA measurements (Hologic QDR 2000) including the vertebral levels L2 to L4 were performed in 331 postmenopausal women. In 42 women an overlap of L4 by the pelvis was suspected on the lateral DXA images. Vertebral fractures were assessed as a fracture/non-fracture dichotomy. L4 and combinations of vertebrae including L4 showed the best discriminatory capabilities with respect to vertebral fractures in receiver operating characteristic (ROC) analyses, t-tests and Z-scores, with smaller variability of the results when multiple vertebral levels were used. The areas under the ROC curves were 0.662 and 0.639 for lateral and PA measurements of L2 to L4, respectively when all women were included. Excluding the women with pelvic overlap on lateral DXA scans improved the ROC area for lateral scans to 0.686 while that for PA scans remained almost constant (0.641). The differences between PA and lateral measurements were not statistically significant. In 162 women of our study cohort an additional quantitative computed tomography (QCT) measurement of the vertebral levels L2 to L4 was performed and overlapping bony structures at the three levels were studied.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Evaluation of technical factors affecting the quantification of trabecular bone structure using magnetic resonance imaging.

High resolution magnetic resonance (MR) techniques combined with standard techniques of stereology and texture analysis have been used to quantify trabecular structure. Using dried excised specimens from the tibia (n = 10) and radius (n = 2) we evaluate the impact of using volumetric gradient-echo (GE) and spin-echo (SE) MR imaging sequences, the relative importance of echo time in gradient-echo MR imaging, and the impact of different threshold values to segment the bone and bone marrow on the estimation of trabecular bone structure. We also investigate the inter-relationships between the different structural parameters derived from MR images. Images were obtained using fast gradient-echo and spin-echo imaging sequences, with TE values ranging from 7 to 17 ms using 4.7 and 1.5 Tesla imaging systems. In-plane image resolution ranged from 128 to 156 microns, and slice thickness ranged from 128 to 1000 microns. We derived stereological measures such as the mean intercept length, trabecular width, fractional area of trabecular bone, trabecular number, and trabecular spacing, the fractal dimension as a texture-related parameter and the Euler number as a measure of connectivity from these images. We found that the mean intercept length as a function of angle traced an ellipse with the orientation of the principal axis of the ellipse, a measure of trabecular orientation, identical when measured from the spin-echo or gradient-echo MR images. Absolute measures such as the fractional area, trabecular width, trabecular number, and fractal dimension as measured from gradient echo images were 28%, 30%, 1.3%, and 0.6% greater, respectively, than those calculated from spin-echo images, while the trabecular spacing was 14% less when calculated from gradient-echo images compared to spin-echo images. The structural parameters also depended on the echo time used to obtain the MR image. The choice of the threshold used to segment the high resolution images also affected the estimated structural parameters significantly. Our results indicate that MR may be used to visualize and quantify trabecular bone architecture; however, the different technical factors that could affect the appearance of MR images must be understood and considered in the data analysis and interpretation.

Absorptiometry, Photon↗

A comparison of bone densitometry measurements of the central skeleton in post-menopausal women with and without vertebral fracture.

The purpose of this investigation was to compare the ability of two different bone densitometry techniques (quantitative computed tomography and dual X-ray absorptiometry) to discriminate subjects without any vertebral fracture from those with definite vertebral fractures. Bone mineral density (BMD) was determined in 112 post-menopausal women. 83 women were classified free of vertebral fracture and 29 were considered to have definite vertebral fractures. Quantitative computed tomography (QCT) was performed using three different spinal regions of interest. Dual X-ray absorptiometry (DXA) was measured at the spine (both in posteroanterior (PA) and lateral (L-DXA) projection, and at hip (total, neck and Ward regions). An additional estimated volumetric BMD was derived from the PA and L-DXA spine scans. Individuals with definite vertebral fractures had lower bone mineral density for each of the methods and regions of interest (ROI). Spinal QCT results, total and Ward hip DXA results showed the greatest percentage decrement. Odds ratio estimates revealed a significant relationship between BMD and fracture with spinal QCT, hip, and volumetric spinal DXA. The greatest areas under the receiver operating characteristic (ROC) curves were found with results of spinal QCT, total and Ward hip DXA, and volumetric spinal DXA measurements. It is concluded that spinal QCT and femoral total DXA measurement may be preferred to PA and lateral L3 DXA measurements.

Absorptiometry, Photon↗

The impact of bone size on broadband ultrasound attenuation.

Quantitative ultrasound (QUS) is a simple, inexpensive and radiation-free technique to study skeletal status in osteoporosis. Broadband ultrasound attenuation (BUA) is typically used without normalizing for bone thickness. We investigated the impact of bone thickness on BUA, both in in vitro and in vivo, using commercially available ultrasound scanners (Walker Sonix UBA 575 and 575+). For the study in vitro, we analyzed 12 paired cubes (12 x 12 x 12 mm3) of bovine trabecular bone cut from six "parent" blocks (24 x 12 x 12 mm3). These "parent" blocks showed a fairly homogeneous structure as assessed by conventional radiography. BUA and dual x-ray absorptiometry (DXA) measurements of bone mineral density (BMD) were obtained. The difference between the paired cubes was significant for BUA (p < 0.001), but not for BMD (p > 0.05). The BUA of the "parent" blocks was larger by 32-92% than the average BUA of the corresponding paired cubes, and always less than the sum of the paired cubes (5-34%). BUA thus added up in a complex and nonlinear fashion. Measurements in vivo of the calcaneal bone width demonstrated on radiographs (study in vivo I, 28 postmenopausal women) and CT images (study in vivo II, 17 women) showed a small, positive but not significant correlation with BUA (r2 = 0.13 and r2 = 0.007, p > 0.05). The magnitude of this effect provides further evidence that BUA does not scale linearly with bone size. Our results indicate that simple normalization of BUA data by specifying the results in decibels per megahertz per millimeter units may not be appropriate.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[The effect of a low-dose hydrochlorothiazide therapy on the bone mineral content of the axial and peripheral skeleton].

An increase in bone mineral content (BMC) as well as a decrease in the incidence of fracture of the proximal femur have been described in patients on thiazide diuretic treatment. A study was undertaken to assess, by means of dual X-ray absorptiometry, the effect of chronic low-dosage antihypertensive treatment with hydrochlorothiazide (HCT; < or = 25 mg daily) on lumbar vertebrae (representing the axial skeleton) and the nondominant radius (peripheral skeleton). Measurements were made on 27 women (mean age 63.8 +/- 8.2 years) and 23 men (65.9 +/- 9.5 years) and compared with a control group of 19 women (62 +/- 8.7 years) and 20 men (65.9 +/- 9.5 years) with minor surgical or dermatological lesions who had never taken HCT or other drugs with potential effects on mineral bone metabolism. In men who had been on HCT for more than 5 years, BMC of the lumbar vertebrae was higher by 10.3% and of the radius by 3.8% than among the controls (differences not significant). In women who had been on HCT for more than 5 years, the corresponding increases were 19.6% (P < 0.05) and 5.4% (not significant). Among those patients who had been on HCT for less than 5 years there were no significant differences compared with the control group. There were no significant differences between the groups relating as regards the proximal radius which, in contrast to the ultradistal radius, consists predominantly of cortical bone. -These data indicate that, while HCT has only a slight influence on BMC, it can be considered to have a desirable associated effect in the antihypertensive treatment of elderly patients.

Absorptiometry, Photon↗

Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results.

The comparison of patient data among different dual x-ray absorptiometry (DXA) scanners is complicated because no universally accepted cross-calibration procedure or standard currently exists. This study was performed under the auspices of the International DXA Standardization Committee to establish appropriate cross-calibration parameters. Posteroanterior (PA) lumbar spine measurements of 100 women, ages 20-80 years (mean 52.6 +/- 16, range of BMD = 0.4-1.6 g/cm2) were obtained on a Norland XR26 Mark II, a Lunar DPX-L, and a Hologic QDR 2000 densitometer using standard procedures (pencil beam mode for all three scanners). Area, BMC, and BMD results from the different scanners were compared for all patients. In addition, the European spine phantom (ESP) and the European spine phantom prototype (ESP prototype), as well as standard phantoms from all three manufacturers, were evaluated on the three systems. To achieve universal scanner calibration, we used the intercept and slope of the patient's correlations and the value of the middle vertebra of the ESP as a reference point in a series of standardization formulas, and we have expressed the results as sBMD (mg/cm2). The correlations of the patients' spinal BMD values were excellent for each of the three scanner pairs. The average absolute difference in patient spinal BMD values (L2-4) between Hologic and Norland was 0.012 g/cm2 (1.3%); it was 0.113 g/cm2 (11.7%) between Hologic and Lunar and 0.118 g/cm2 (12.2%) between Norland and Lunar. The phantoms' regression lines approximated those of the patient regression lines, and the phantoms with only one measurement point were very close to the patients' regression lines. After applying the standardization formulas, the average absolute differences for the 100 patients were 28 mg/cm2 (2.7%) for Hologic/Norland, 23 mg/cm2 (2.2%) for Hologic/Lunar, and 29 mg/cm2 (2.8%) for Norland/Lunar. Average BMD results for the patients before correction were 0.972 mg/cm2 for Hologic, 1.100 g/cm2 for Lunar, and 0.969 g/cm2 for Norland. After correction, sBMD results for patients were 1045 mg/cm2 for Hologic, 1047 mg/cm2 for Lunar, and 1043 mg/cm2 for Norland. The standardization approach as performed in our study provided compatibility of DXA results obtained on different scanners.

Absorptiometry, Photon↗

Interobserver variation in the detection of osteopenia by radiography and comparison with dual X-ray absorptiometry of the lumbar spine.

In 100 patients (20 male, 80 female) radiographs of the lumbar spine were obtained in both planes, anteroposterior and lateral. Nine readers independently and without specific criteria or training assessed the radiographs for presence of osteopenia in the form of a binary decision. A posteranterior dual x-ray absorptiometry (PA DXA) measurement of the lumbar spine was performed in all patients using the Hologic QDR 1000 bone densitometer. A bone mineral density (BMD) of 0.83 g/cm2 (T-score about 2 SD and 2.5 SD lower than BMD in normal young female and male subjects respectively) was used as a threshold for the diagnosis of osteopenia. Complete agreement amongst the 9 readers was achieved in 43 patients. In 26 more patients at least 8 readers agreed. kappa-coefficients for interobserver variation ranged from 0.458 to 0.691 for reader pairs. For agreement between the observer ratings and the DXA results, kappa-coefficients ranging between 0.347 and 0.555 were found. The vast majority of readers agreed in the diagnosis of osteopenia in cases where the BMD was less than 0.73 g/cm2. Where the BMD was between 0.73 and 1.03 g/cm2 a substantial disagreement was found between reader evaluation and DXA measurement, and also amongst the readers. We conclude from our results that osteopenia can reliably be detected from lumbar spine radiographs by all readers only after a substantial amount of BMD is lost. On the other hand, a diagnosis based solely on PA DXA measurement of the spine may also lack accuracy, due to a substantial influence of degenerative changes of the lumbar spine and aortic calcification.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗