A new apheresis procedure for the preparation of high-quality red cells and plasma.

BACKGROUND: Multicomponent apheresis is an alternative way of preparing blood components that avoids the delay between collection and separation seen with standard whole-blood techniques. STUDY DESIGN AND METHODS: An apheresis device has been modified to facilitate the combined collection of a unit (250 mL) of red cells (RBCs) and a high-volume unit (475 mL) of plasma. The procedure, using 8-percent ACD-A, has been tested in two European blood centers. Each center performed 20 procedures for in vitro evaluation of collected RBCs and plasma and 10 procedures for evaluation of in vivo RBC recovery. All RBCs were white cell reduced by filtration. One-half of the RBC units were stored in the additive solution Adsol and one-half in another such solution (Erythro-Sol). RESULTS: The target volumes of RBCs and plasma were obtained in 27 minutes (range, 20-44 min) by using three to six cycles in a single-needle procedure. Saline (275 mL) was used to replace fluid volume withdrawn in excess of standard whole-blood donation. No side effects occurred, with the exception of minor signs of hypocalcemia. RBC ATP was well maintained (>65% at Day 42) during storage; 2,3-DPG was less well maintained, with virtually none remaining at Day 21 in either Adsol or Erythro-Sol. The RBC in vivo recoveries, after 42 days of storage at 4+/-2 degrees C determined by the single-label method, were 86.7+/-7.2 percent (Erythro-Sol) and 84.4+/-8.1 percent (Adsol). Mean plasma factor VIII levels were >100 percent in all test groups. CONCLUSION: A novel automated technique for the simultaneous collection and preparation of RBCs and plasma has been evaluated. The apheresis procedure was acceptable and well tolerated by donors, and it resulted in high-quality blood components. Further optimization of the system should yield a practicable component suitable for routine use in blood banks.

Blood Component Removal↗

Platelets stored in a new-generation container differences between plasma and platelet additive solution II.

BACKGROUND AND OBJECTIVES: In order to preserve platelet concentrates (PCs) with high yields, a new polyolefin platelet storage container (PL 2410, 1.3L, Baxter, La Châtre, France) with increased gas permeability in combination with a larger surface area has been developed. The storage capacity was studied with platelets in plasma and platelets additive solution. MATERIALS AND METHODS: Platelet concentrate pools (PCs) of different yields suspended in either plasma (PCs-PL; n = 30) or PAS II (PCs-PAS; n = 37) were prepared. For preparation of PCs with a low, intermediate and high number of platelets 3, 5 and 6 buffy coat (BCs) were pooled with different volumes of plasma and 5 and 6 BCs were pooled with different volumes of PAS II, in order to obtain PCs of equal volumes comparable with routine conditions. All PCs were stored on a flatbed shaker at 22+/-2 degrees C and evaluated on days 1, 2, 5 and 7 by determining platelet and white cell counts, pH (37 degrees C), pO2, pCO2 and swirling score. RESULTS: Platelet yields ranged from 1.5 up to 5.5 x 10(11) platelets/U. On day 7 all PCs-PL (n = 4) with platelet yields above 4.5 x 10(11)/U had a pH value below 6.8 (range 5.91-6.79). While 7 of 8 PCs-PAS units with platelet yields above 4. 0 x 10(11)/U showed a pH value below 6.8 (range 6.31-6.70). CONCLUSION: During 7 days of storage in a new 1.3-liter platelet container, the pH was maintained above 6.8 in PCs in plasma with a yield between 1.5- and 4.5 x 10(11)/U; when PAS II was used, the maximum platelet yield allowed for comparable pH maintenance was somewhat lower (4.0 x 10(11)/U).

Adult↗

A system for the supply of platelets suspended in a storage medium including buffy-coat-derived platelet concentrates in combination with "split" apheresis platelets.

Our objective was to create a system for the supply of platelet concentrates (PCs) based on leukocyte-filtered PCs suspended in a storage medium (PAS-II) including: (1) pooled buffy-coat-derived (BC) PCs and (2) "split" apheresis PCs. The same standards were intended for the two preparations with regard to composition and blood cell counts. In preliminary studies, similar in vitro data were found for leukocyte-filtered and non-filtered reference BC PCs. Slightly inferior in vitro results than for BC PCs restricted the shelf-life of apheresis PCs to 5 days compared to 7 days for BC PCs. With the present platelet supply system in use as a routine service for one year, the experience was very satisfactory, meeting the demands for PCs very efficiently and resulting in a low out-dating rate (5%).