PubMed Health⌕ Search

Biomedical subjects

M K Dewanjee

Publications and source records attributed to M K Dewanjee.

At least 109 records · Page 6Linked to original sources

Autoradiography of live and dead mammalian cells with 99mTc-tetracycline.

Considering the diagnostic significance of a few 99mTc-chelates in the diagnosis of myocardial infarct, we have recently developed a necrosis model in tissue culture obtained from mammalian cells, where the dead cells showed enhanced binding of 99mTc-tetracycline like the necrotic cells of infarcted myocardium. Technical details of the principles of labeling, fixing, washing and drying, dipping in emulsion, exposure, development and staining of mammalian cells have been described. Considering the short half-life of 99mTc-radioisotope, the recently available techniques have been modified to make autoradiography possible in a reasonably short period of time. Technetium-99m in different physical and chemical states is playing a very important role in a variety of diagnostic procedures. The autoradiography of 99mTc-labeled cells and tissue will shed further light on the mechanism of cellular uptake and subcellular distribution in normal and pathologic states. Presently no information is available regarding autoradiography with 99mTc-chelates of mammalian cells obtained from tissue culture.

Autoradiography↗

Fluid mechanics of arterial stenosis: relationship to the development of mural thrombus.

In this study, we analyzed blood flow through a model stenosis with Reynolds numbers ranging from 300 to 3,600 using both experimental and numerical methods. The jet produced at the throat was turbulent, leading to an axisymmetric region of slowly recirculating flow. For higher Reynolds numbers, this region became more disturbed and its length was reduced. The numerical predictions were confirmed by digital particle image velocimetry and used to describe the fluid dynamics mechanisms relevant to prior measurements of platelet deposition in canine blood flow (R.T. Schoephoerster et al., Atherosclerosis and Thrombosis 12:1806-1813, 1993). Actual deposition onto the wall was dependent on the wall shear stress distribution along the stenosis, increasing in areas of flow recirculation and reattachment. Platelet activation potential was analyzed under laminar and turbulent flow conditions in terms of the cumulative effect of the varying shear and elongational stresses, and the duration platelets are exposed to them along individual platelet paths. The cumulative product of shear rate and exposure time along a platelet path reached a value of 500, half the value needed for platelet activation under constant shear (J.M.. Ramstack et al., Journal of Biomechanics 12: 113-125, 1979).

Algorithms↗

Development of sensitive radioiodinated anti-sense oligonucleotide probes by conjugation technique.

Radioactive and nonradioactive oligonucleotide (ON) probes have been used in a variety of studies of in vitro hybridization for locations of specific genes and determination of the level of mRNA transcription in activated and proliferative cells. Nuclease-resistant phosphorothioate derivatives of oligonucleotides are also finding potential therapeutic applications in intact cells and animal models. In this study, we have developed new techniques of radioiodination by the conjugation of oligonucleotides with p-methoxyphenyl isothiocyanate (PMPITC) and optimized the conditions of the radioiodination, e.g. concentration of reactants, oxidants, pH, time, and temperature. We have used a 25-mer actin mRNA probe as a model substrate for radioiodination. The ON probe was modified by conjugation with the addition of aminohexyl (AH) group at the 5'-terminal. Both the techniques of preiodination of PMPITC followed by conjugation and radioiodination of PMPITC-conjugated AHON were evaluated; the latter was found to be more convenient. The optimum pH of radioiodination of PMPITC with 125I was 6.5; on the other hand, the optimum pH for PMPITC-conjugated AHON was 8.5. The conditions of conjugation were optimized with 125I-labeled PMPITC. The techniques of paper chromatography and HPLC with a Spherogel column were developed for the purification and characterization of these oligonucleotide probes. Without PMPITC conjugation, the yield of direct radioiodination of the same oligonucleotide was very low (4-6%); the yield in our optimized technique is 50-60%. Radioiodination of conjugated oligonucleotides is a simple and efficient route to radiolabeled probes for hybridization studies.

Amines↗

Viability and functional integrity of washed platelets.

The viability and functional integrity of saline- and ACD-saline-washed platelets were compared with those of unwashed platelets. After template bleeding time (TBT) was measured, 15 healthy volunteers underwent plateletpheresis and ingested 600 mg of aspirin. Autologous 111In-labeled platelets were transfused: unwashed (n = 5), washed with 0.9 percent saline solution (SS) (n = 5), and washed with a buffered 12.6 percent solution of ACD-A in 0.9 percent saline solution (n = 5). After transfusion, we measured TBT at 1, 4, and 24 hours; platelet survival at 10 minutes and 1, 4, and 24 hours and daily for 6 days; and the percentage of uptake in liver and spleen by quantitative whole-body radionuclide scintigraphy at 24 and 190 hours. We found that saline washing affected platelet recovery, 23.47 +/- 12 percent (p less than 0.001) as compared to 52.43 +/- 17 percent (p less than 0.002) for ACD-saline and 73.17 +/- 8 percent for control; that saline washing resulted in a greater liver uptake than control and ACD-saline-washed platelets (31.9 +/- 8% [p less than 0.001] vs 17.7 +/- 4.1 and 19.3 +/- 2.1% [p greater than 0.1], respectively); that, unlike control and ACD-saline-washed platelets, saline-washed platelets did not shorten bleeding time; and that neither type of washing affected survival. Although ACD-saline washing affects recovery, it also results in intact function, normal survival, higher recovery than SS platelets, and no significant liver uptake.

Bleeding Time↗

Quantitation of platelet and fibrinogen-fibrin deposition on components of tissue valves (Ionescu-Shiley) in calves.

With 111In-labeled platelets and 125I-labeled bovine fibrinogen, regional mapping of platelet and fibrinogen deposition on leaflets and sewing rings was obtained. Ten Holstein calves received 25-mm mitral valves (ISLM) and were killed 1, 14, and 30 days after implantation. Twenty-four hours before the calves were killed, 350 to 450 microCi of 111In-labeled platelets and 200 to 250 microCi of 125I-labeled bovine fibrinogen were administered intravenously. The components of the tissue valves, i.e., three leaflets and sewing rings, were separated. Each leaflet was cut into four sections: free edge, central zone, flexion zone, and attachment zone. From the radioactivity in blood, leaflet zones, sewing rings, area of leaflet zones, platelet count, and fibrinogen level in blood, the mean regional density of adherent platelets, fibrinogen-fibrin, and fibrinogen/platelet were calculated. The density of platelets and fibrinogen deposited on the components of the valves decreases with time postimplantation. The number of fibrinogen molecules per platelet is fivefold to 20-fold higher than that of the receptor concentration on platelets on leaflet zones, suggesting the heterogeneity of fibrinogen-fibrin in thrombus and components of the valve.

Animals↗

Kinetics and quantitation of In-111 labeled platelet deposition on control and heparin-bonded polyurethane angio catheters in a dog model.

The dynamics of platelet deposition on control polyurethane catheters (CPC) and heparin-bonded polyurethane catheters (HBPC) were evaluated with In-111 labeled platelets (In-PLT) using a computerized gamma camera (CGC). Ten nonheparinized dogs (18-25 kg) had both femoral arteries catherized with 10 cm of CPC and HBPC (5 Fr.) 24 hr postinjection of 300-420 microcuries of In-PLT, and imaged for 3 hr with a gamma camera. Regional platelet deposition on three segments of catheters and the puncture site was determined. Catheters were harvested and radioactivity on the catheter segments (proximal: PROX, middle: MID, distal: DIST and puncture site: PS) of both was determined. From the platelet count in blood, and radioactivity in blood and segments of catheters, adjacent artery, and area of artery and catheter, the platelet-density [X10(3) (mean +/- S.D.)] on catheter and artery was calculated and tabulated. Proximal values were cath (CPC), 1289 +/- 1125; artery, 1355 +/- 587; cath (HBPC), 125 +/- 113; artery, 1149 +/- 1620. The middle values were cath (CPC), 1102 +/- 1109; artery, 1512 +/- 625; cath (HBPC), 132 +/- 108; artery, 1011 +/- 942. Distal values were cath (CPC), 780 +/- 584; artery, 132 +/- 108; cath (HBPC), 227 +/- 194; artery, 1457 +/- 1309. The puncture site values were cath (CPC), 106 +/- 382; artery, 1011 +/- 942; cath (HBPC), 164 +/- 135; artery, 1498 +/- 1240. The large standard deviation in retained platelets is due to embolization. The platelet-density and regional counts on catheter segments were lower with HBPC than CPC, as was the rate of platelet-deposition.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Quantitation of platelet loss with indium-111 labeled platelets in a hollow-fiber membrane oxygenator and arterial filter during extracorporeal circulation in a pig model.

Platelet consumption in a hollow-fiber membrane oxygenator (HFMO) and arterial filter (AF) during cardiopulmonary bypass (CPB) was quantified in five pigs using Indium-111 labeled autologous platelets. Platelet labeling was performed 20-24 hours before CPB. After general endotracheal anesthesia, the pigs were systemically heparinized and were placed on CPB via a median sternotomy. After 3 hours of CPB, radioactivity was quantified with a gamma camera and an ionization chamber. The percent of injected dose (mean +/- SD) was 0.79 +/- 0.45 in the HFMO, 2.52 +/- 0.93 in AF, 4.3 +/- 1.2 in blood loss during CPB. Platelet consumption in HFMO during CPB was lower than in bubble oxygenators (19%) or silicone membrane oxygenators (12%) as observed in previous studies.

Animals↗

Rate constants of embolization and quantitation of emboli from the hollow-fiber oxygenator and arterial filter during cardiopulmonary bypass.

A direct technique was developed to estimate parameters related to half life (T1/2) and rate constants of embolization (RCE) and to quantitate emboli of three sizes (small, medium, and large) shed from the oxygenator and arterial filter during cardiopulmonary bypass (CPB). Cardiopulmonary bypass was performed in 16 Yorkshire pigs divided as follows: systemic heparin group (SHG:6), systemic heparin/heparinized circuit group (SH/HCG:5), and Iloprost (Bentley) (2 ng/kg/min)/heparinized circuit group (IHCG:5) with In-111 labeled autologous platelets. The anesthetized pigs (20-25 kg) underwent CPB at 2.5-3.0 L/min for 3 hours. Pigs were injected with In-111 platelets (300-420 microCi) 24 hours before CPB. Cardiopulmonary bypass was instituted with a roller pump and hollow-fiber oxygenator, and thrombosis and embolization on the oxygenator and filter were monitored by a calibrated Geiger probe (WMB Johnson Associates, Montvale, NJ). The radioactivity in the oxygenator and filter reached peak values at 25-45 min after CPB; the radioactivity then declined in the oxygenator but remained at a steady state in the filter, suggesting continuous embolization at the same rate of trapping. The curve stripping technique of the normalized radioactivity time curve of the oxygenator was used for RCE estimation of different sized emboli shed from the oxygenator; 42% of thrombus embolized from the oxygenator in SHG with three rate constants, with T1/2s of 12 min, 42 min, and 13 hr; the SH/HCG embolized 35% with T1/2 of 78 min, and the IHCG embolized 30%, with a T1/2 of 22 min. This indicates that there is less embolization in the IHCG.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Neutrophil dynamics and retention in lung, oxygenator, and arterial filter during cardiopulmonary bypass in a pig model.

Interactions of neutrophils with adsorbed proteins in components of the cardiopulmonary bypass (CPB) circuit and expression of leukocyte adhesion molecules on activated neutrophils affect neutrophil kinetics and margination. Lung and skeletal muscle along with oxygenator (OX) and arterial filter (AF) in the extracorporeal circuit provide the major areas of neutrophil (N) interaction. The dynamics of N-interaction and N-retention during 3 hr CPB was quantified with autologous In-111 labeled neutrophils (INN) in 4 groups of 20 Yorkshire pigs (28-35 kg, 5 sham; 5 CPB, 1 hr; 5 CPB, 3 hr and 5 CPB with heparinized circuit, 3 hr); anesthetized pigs were injected with INN (500-650 microCi), 30 min before CPB and heparinized, and underwent CPB with a roller pump, a hollow fiber OX (Bentley CM 50, 5.0 m2) and AF (Bentley AF 025, 0.25 m2) at 2.5-3.6 l/min for 3 hr. N-dynamics on OX and AF was monitored by a calibrated Geiger probe. Neutrophil deposition, like that of plasma proteins on OX, reached a steady state almost instantly, but increased on filter with CPB time. INN distribution was viewed with a gamma camera; total INN was measured with an ion chamber and INN in samples of fibers and tissues was quantified with a gamma counter. INN in lung did not change significantly during CPB and increased in liver. The percentage of injected INN in lung, liver, and brain changed with CPB time and showed significant increase over sham-operated animals. Heparin coating of components decreased INN retention. INN/meter2 of lung, OX, and AF at 3 hr were 0.26 +/- 0.07%, 0.06 +/- 0.02%, and 6.17 +/- 3.94%, and significantly lower on a heparin coated filter (2.14 +/- 1.30%). Capillary surface areas of viscera and connective tissues (lung, 100; liver, 134; spleen, 20; heart, 7; skeletal muscle, 92; fat, 12; bone, 3; bone marrow, 5; brain, 0.1 meter2) were estimated from distribution of activated INN in pigs. Lung INN retention was much higher than that of the polymer surfaces of OX/AF, indicating the role of cell adhesion molecules on INN retention on endothelial cells of lung and viscera. By direct continuous monitoring and quantitation of INN at the end of CPB, a sensitive technique for quantitation of neutrophil kinetics, margination, and retention during CPB was developed.

Animals↗

Reduction of neutrophil margination by L-arginine during hypothermic cardiopulmonary bypass in a pig model.

Nitric oxide generation by L-arginine (2 mg/kg/min) infusion during cardiopulmonary bypass (CPB) increases blood flow to all organs and reduces cytokine induced organ damage by reducing the level of marginating neutrophils (Ns). The N-trapping in the oxygenator (OX), arterial filter (AF), cardiotomy reservoir (CR), and N-margination were quantified with indium 111 labeled autologous neutrophils (INN) in nine groups of 40 Yorkshire pigs (30-35 kg). Cardiopulmonary bypass (180 min or 90 min CPB, 90 min reperfusion) was carried out at 2.5-3.5 L/min and at two temperatures (18 degrees C, 28 degrees C). The INN (650-780 microCi) was administered intravenously 15 mins before CPB. All pigs received heparin systemically (activated coagulation time > 400 secs); CPB was instituted with a roller pump, OX (Univox 1.8 m2), AF (0.25 m2), and CR (BCR-3500, Bentley Lab, Irvine, CA). The INN distribution in the device (OX, AF, CR) and organs was imaged with a gamma camera and measured with an ion chamber and a gamma counter. The LA infusion decreased N-trapping, estimated as the percent of injected INN (mean +/- standard deviation), in OX from control (2.7 +/- 2.02)% to (0.94 +/- 0.29)%, and margination in lung from control (48 +/- 4)% to minimal levels (23 +/- 2)% (p < 0.01). In the CPB reperfusion group, a beneficial effect was observed at LA low dose and toxicity of higher N-margination at 15 mg/ kg/min. Neither CPB temperature nor Leumedin affected N-margination significantly.

Animals↗