Amblyopia: is visual loss permanent?

AIM: To ascertain whether recovery of visual function in amblyopic eyes is likely to occur when the fellow eye is lost as a result of age related macular degeneration. METHODS: The records of 465 patients with an established diagnosis of age related macular degeneration who had attended a specialist macular clinic between 1990 and 1998 were scrutinised. A full clinical examination and standardised refraction had been carried out in 189 of these cases on a minimum of two occasions. Cases were looked for where an improvement of one or more lines of either distance or near acuity was recorded in the eye unaffected by macular disease. In each one of these cases the improvement in visual acuity could not be attributed to treatment of other existing pathology. RESULTS: 12 such cases were detected. In nine of these the eye showing improvement of acuity had a history of amblyopia. The mean improvement in distance and near acuity in amblyopic eyes by 12 months was 3.3 and 1.9 lines logMAR respectively. The improvement in acuity generally occurred between 1 and 12 months from baseline and remained stable over the period of follow up. CONCLUSIONS: Older people with a history of amblyopia who develop visual loss in the previously normal eye can experience recovery of visual function in the amblyopic eye over a period of time. This recovery in visual function occurs in the wake of visual loss in the fellow eye and the improvement appears to be sustained.

Amblyopia↗

Transcatheter occlusion of the patent ductus arteriosus: a comparison of two devices.

BACKGROUND: Transcatheter occlusion of the arterial duct is a safe and effective alternative to surgical closure. The Rashkind umbrella occluder and the Cook coil are two established devices, although the former is no longer manufactured. AIMS: To assess any difference in outcomes between the use of the Cook detachable coil and the Rashkind double umbrella in patent ductus arteriosus (PDA) occlusion. METHODS: A retrospective study of 77 patients in whom PDA occlusion was attempted using the Cook detachable PDA coil from March 1996 to March 2000. A comparison was carried out with patients in whom occlusion was attempted using the Rashkind double umbrella between 1989 and 1996. RESULTS: The rate of immediate complete occlusion was 24% compared with 29.9% for the Rashkind device. The figure for complete occlusion after 24 hours with the PDA coil was 63% compared with 61.5% in the Rashkind group (p > 0.1). The overall closure rate in the coil group was 72% versus 74.6% for umbrellas. CONCLUSION: The outcome in terms of complete duct closure using the Cook coil is comparable with figures obtained using the Rashkind umbrella. Both devices have a good safety profile in the short and medium-terms.

Cardiac Catheterization↗