PubMed HealthSearch

Biomedical subjects

M K Giles

Publications and source records attributed to M K Giles.

2 recordsLinked to original sources

Preexposure to amphetamine and nicotine predisposes rats to self-administer a low dose of cocaine.

The acquisition of low-dose (0.25 mg/kg/infusion) intravenous cocaine self-administration was measured in rats that had received nine daily injections of amphetamine (1.0 mg/kg, IP), nicotine (0.6 mg/kg base weight, SC) or vehicle. For control rats, the acquisition of self-administration was gradual with the number of responses per 2 h daily test session increasing between days 3 and 9. By comparison, rats preexposed with amphetamine and nicotine demonstrated elevated response means during the early days of testing, suggesting more rapid acquisition. All groups eventually reached similar asymptotic levels of responding. The enhanced responding observed during the early days of testing in the rats preexposed with amphetamine and nicotine was due to an increased number of subjects that reliably self-administered cocaine. Thus, the rats preexposed with amphetamine and nicotine seemed predisposed to the reinforcing effects of cocaine. In contrast to the self-administration data, preexposure to nicotine failed to sensitize rats to the locomotor activating effects of cocaine. In fact, the same preexposure regimen appeared to produce tolerance to this effect of cocaine. These data give evidence that different mechanisms may mediate sensitization to the reinforcing and locomotor activating effects of cocaine.

Amphetamine

Aberration tolerances for visual optical systems.

The effects of aberrations on images formed by a total system, including the eye, are assessed in terms of modulation threshold, grating detectability, and modulation transfer functions. The effects of approximately one and two waves of third-order spherical aberration, coma, and astigmatism on the total system modulation transfer function are investigated using three-bar resolution targets and Ronchi rulings in two separate psychophysical experiments. The results of both experiments indicate that the experimentally determined system modulation transfer function is closely approximated by the theoretically calculated modulation transfer function of the total system optics (dioptrics included) in the presence of instrument aberrations. The data indicate that the eye accomodates of a "best focus" when spherical aberration and astigmatism (but not coma) are present in the instrument. The quantitative data are used to determine aberration tolerances for instruments that are designed for specific visual tasks and that employ simple targets similar to those investigated.

Accommodation, Ocular