PubMed Health⌕ Search

Biomedical subjects

M K Ivancevic

Publications and source records attributed to M K Ivancevic.

4 recordsLinked to original sources

Optimization of cardiac cine in the rat on a clinical 1.5-T MR system.

OBJECT: The overall goal was to study cardiovascular function in small animals using a clinical 1.5-T MR scanner optimizing a fast gradient-echo cine sequence to obtain high spatial and temporal resolution. MATERIALS AND METHODS: Normal rat hearts (n = 9) were imaged using a 1.5-T MR scanner with a spiral fast gradient-echo (fast field echo for Philips scanners) sequence, three Cartesian fast gradient-echo (turbo field echo for Philips scanners) sequences with different in-plane resolution, and with and without flow compensation and half-Fourier acquisition. The hearts of four rats were then excised and left-ventricle mass was weighed. Inter- and intra-observer variability analysis was performed for magnetic resonance imaging (MRI) measurements. RESULTS: Half-Fourier acquisition with flow compensation gave the best sequence in terms of image quality, spatial as well as temporal resolution, and suppression of flow artifact. Ejection fraction was 71 +/- 4% with less than 5% inter- and intra-observer variability. A good correlation was found between MRI-calculated left-ventricular mass and wet weight. CONCLUSIONS: Using optimized sequences on a clinical 1.5-T MR scanner can provide accurate quantification of cardiac function in small animals and can promote cardiovascular research on small animals at 1.5-T.

Algorithms↗

Parametric and quantitative analysis of MR renographic curves for assessing the functional behaviour of the kidney.

The aim of this study was to refine the description of the renal function based on MR images and through transit-time curve analysis on a normal population and on a population with renal failure, using the quantitative model of the up-slope. Thirty patients referred for a kidney MR exam were divided in a first population with well-functioning kidneys and in a second population with renal failure from ischaemic kidney disease. The perfusion sequence consisted of an intravenous injection of Gd-DTPA and of a fast GRE sequence T1-TFE with 90 degrees magnetisation preparation (Intera 1.5 T MR System, Philips Medical System). To convert the signal intensity into 1/T1, which is proportional to the contrast media concentration, a flow-corrected calibration procedure was used. Following segmentation of regions of interest in the cortex and medulla of the kidney and in the abdominal aorta, outflow curves were obtained and filtered to remove the high frequency fluctuations. The model of the up-slope method was then applied. Significant reduction of the cortical perfusion (Qc = 0.057+/-0.030 ml/(s 100 g) to Qc = 0.030 +/- 0.017 ml/(s 100 g), P < 0.013) of the medullary perfusion (Qm = 0.023 +/- 0.018 ml/(s 100 g) to Qm = 0.011 +/- 0.006 ml/(s 100 g), P < 0.046) and of the accumulation of contrast media in the medulla (Qa = 0.005 +/- 0.003 ml/(s 100 g) to Qa = 0.0009 +/- 0.0008 ml/(s 100 g), P < 0.001) were found in presence of renal failure. High correlations were found between the creatinine level and the accumulation Qa in the medulla (r2 = 0.72, P < 0.05), and between the perfusion ratio Qc/Qm and the accumulation Qa in the medulla (r2 = 0.81, P < 0.05). No significant difference was found in times to peak between both populations despite a trend showing Ta the time to the end of the increasing contrast accumulation period in the medulla, arriving later for renal failure. Advances in MR signal calibration with the building of quantitative model such as the up-slope allow to assess kinetic and haemodynamic and functional parameters of the diseased kidney.

Contrast Media↗

Current status of cardiac MRI in small animals.

Cardiac magnetic resonance imaging (MRI) on small animals is possible but remains challenging and not well standardized. This publication aims to provide an overview of the current techniques, applications and challenges of cardiac MRI in small animals for researchers interested in moving into this field. Solutions have been developed to obtain a reliable cardiac trigger in both the rat and the mouse. Techniques to measure ventricular function and mass have been well validated and are used by several research groups. More advanced techniques like perfusion imaging, delayed enhancement or tag imaging are emerging. Regarding cardiac applications, not only coronary ischemic disease but several other pathologies or conditions including cardiopathies in transgenic animals have already benefited from these new developments. Therefore, cardiac MRI has a bright future for research in small animals.

Animals↗

FAST sequences optimization for contrast media pharmacokinetic quantification in tissue.

The purpose of this study was to investigate the influence of the fast gradient-recalled echo (GRE) sequence parameters on the contrast dynamic range and signal sensitivity, to optimize the magnetic resonance (MR) sequence for contrast media pharmacokinetic assessment. Effects of the fast low-angle shot (FLASH), Fast acquisition at steady rate (FAST), and radiofrequency-spoiled (RF)-FAST sequence parameters were studied in vitro. The FAST sequence had the highest sensitivity in low gadolinium (Gd) concentration. The FLASH and RF-FAST sequences had a larger contrast dynamic range, but the FLASH images contained side band artifacts. Increasing the flip angle to 90 degrees raised the sensitivity of the FAST sequence and the contrast dynamic range of the RF-FAST sequence. The shortest possible TE was optimal for both contrast dynamics and imaging time. TI had an influence on the sensitivity of the FAST sequence only for small acquisition matrices. This study indicates the optimal parameters for contrast dynamics (RF-FAST, 90 degrees flip angle, shortest possible TE) and sensitivity (FAST, 90 degrees flip angle, long TI(eff)).

Contrast Media↗