Contribution of the ocular surface to visual optics.

The air/tear interface contributes 70% of the vergence in the eye and, because of this, even minor variations in its shape can produce significant visual deficit. Placido disc-based corneal topographers measure the precise characteristics of the corneal surface, transforming shape into color-coded dioptric power maps and topography indexes related to optical quality and specific patterns associated with pathology. Artificial intelligence-based methods are used to classify corneal topography and these are used as screening tools. Coupling corneal topography measurements with aberrometry measurements permits the display of the internal aberrations of the eye. Together, these data provide the opportunity to extend refractive correction beyond sphere and cylinder to the higher order aberrations as well.

Cornea↗

Screening of prior refractive surgery by a wavelet-based neural network.

PURPOSE: To demonstrate an objective method of screening for previous refractive surgery using corneal topography. SETTING: Corneal topography research laboratories, LSU Eye Center, New Orleans, Louisiana, USA. METHODS: Videokeratography (TMS-1, Tomey) examinations from the LSU Eye Center were randomly divided into training and test sets that each included 32 normal corneas and 106 corneas with previous radial keratotomy or photorefractive keratectomy from 1 month up to 10 years after surgery. A set of 1024 axial curvature values were extracted from mires 1 to 25 from each cornea to form a 1-dimensional waveform. Multiresolution wavelet decomposition was performed on this waveform using the s8 Symmlet wavelet. A portion of the resulting wavelet coefficients was input into a backpropagation neural network that was trained to 5% error. After training, the independent test set was passed though the neural net and scored. RESULTS: The trained network correctly recognized 32 of 32 normal corneas and 105 of 106 refractive surgery corneas for a 99.3% accuracy, 99.1% sensitivity, and 100% specificity for previous myopic refractive surgery detection. CONCLUSIONS: The 1-dimensional wavelet-based neural network approach was an effective and accurate method of distinguishing eyes that had had myopic refractive surgery from normal eyes. The single error was a result of having too few examples of grossly decentered procedures in the training set.

Cornea↗

Is keratoconus a true ectasia? An evaluation of corneal surface area.

BACKGROUND: Keratoconus has long been considered to be an ectasia produced by stromal stretching. Although stretching should result in increased corneal surface area, previous observations of topography during progression of keratoconus have suggested that surface area may actually be conserved. A novel objective surface area measurement based on corneal topography was tested and applied to data from actual corneas under various conditions for comparative analysis. SETTING: The LSU Eye Center clinic videokeratography archives. METHODS: TMS-1 videokeratography files (Tomey Corp, Cambridge, Mass) were obtained from 6 groups of corneas: normal (n = 29), keratoconus from mild to severe states (n = 51), topographically judged keratoconus-suspect conditions (n = 10), postoperative photorefractive keratectomy for myopia (n = 39), with-the-rule corneal astigmatism (n = 17), and keratoglobus (n = 1). Additionally, 3 different spherical test surfaces were analyzed to verify the accuracy of the process. Only maps with no missing data out to ring 29 were used. The cumulative surface area from center to periphery was determined by calculating and summing the area of individual patches along consecutive annular rings. Mean surface area with respect to mean chord radius was plotted for each corneal condition, and curve fitting was used to extend each result to a 5. 85-mm limbus. Means, SEs, and 95% confidence intervals were calculated at intervals for statistical comparisons among all groups. Computer-generated surfaces helped to evaluate the relationship between shape and surface area. RESULTS: When videokeratographic test targets were used, surface area error was less than 2%, which was deemed acceptable. Normal corneas had a mean +/- SE surface area of 120.3 +/- 2.2 mm(2), whereas all keratoconus corneas combined had a mean +/- SE surface area of 116.2 +/- 3.4 mm(2). The difference was not significant at any chord radius (analysis of variance, P<. 05). The keratoglobus cornea was found to have a surface area of 129. 9 mm(2), which was 7.98% greater than normal. An individual with progressive keratoconus exhibited no appreciable trend toward increasing surface area during a 76-month period. The corneas in the other groups resembled normal corneas in their total surface area. CONCLUSIONS: With the exception of the single case of keratoglobus, corneal surface area tended to be conserved near a value of 120 mm(2) for all groups in the study, including corneas with keratoconus. Surface area is remarkably insensitive to curvature change near the vertex. Flattening seen in the periphery of corneas with keratoconus suggests that biomechanical coupling compensates for any increase in curvature occurring in the region of the cone itself. Thus, it seems that keratoconus is not a true ectasia as is keratoglobus, but rather a specialized type of warpage, at least in mild to moderate forms of the disease. Arch Ophthalmol. 2000;118:1179-1186

Algorithms↗

Anomalous acute inflammatory response in rabbit corneal stroma.

PURPOSE: To investigate the nature and cause of an acute, anomalous stromal edema after epithelial debridement in the rabbit cornea. METHODS: Series I: Adult New Zealand White rabbit corneas were mounted in perfusion chambers. The endothelium was bathed with Ringer's fluid, and the outer surface was covered with silicone oil. The epithelium of one eye was débrided with a scalpel before mounting, and the cornea of the fellow eye was débrided with a rotating brush after stabilization in the perfusion chamber. Using specular microscope tracking software, it was possible to measure total swelling and local swelling within the cornea. Series II: Diclofenac sodium ophthalmic solution 0.1% or a placebo was applied topically, 1 drop per 45 minutes for 3 hours before animals were euthanatized. RESULTS: Series I: Corneas with their epithelium scraped with a scalpel before mounting were 37.5 +/- 17.5 microm (n = 6; P < 0.001) thicker in vitro than the stromas of perfused, intact fellow corneas. Epithelial débridement with a rotating brush after mounting resulted in an immediate (within 8 minutes) stromal swelling that plateaued in 1 hour at 31.0 +/- 5.3 microm (n = 6; P < 0.001). Curiously, in six of six corneas, the anterior stroma swelled more than the posterior stroma. In four of six corneas, the posterior stroma thinned. Analysis showed this pattern to be consistent with a sudden increase in anterior swelling pressure or osmotic pressure and to be inconsistent with a change in endothelial transport properties. Series II: Placebo-treated corneas swelled 30.6 +/- 7.7 microm (n = 5) 1 hour after débridement, whereas corneas pretreated with diclofenac sodium swelled only 19.2 +/- 3.1 microm (n = 6; P < 0.008). CONCLUSIONS: The anterior stromal swelling occurs rapidly and near the site of epithelial injury suggesting messenger and/or enzymatic involvement with an effect parallel to apoptosis. Reduction of the swelling response with nonsteroidal anti-inflammatory drugs (NSAIDs) implicates the cyclooxygenase pathway. The swelling is similar to the unexplained acute edema that occurs during inflammation in the rat paw edema model, and may represent a general mechanism for mobilization of inflammatory cells.

Acute Disease↗

Topographic assessment of irregular astigmatism after photorefractive keratectomy.

OBJECTIVE: To correlate new quantitative topographic indexes of corneal irregular astigmatism to best spectacle-corrected visual acuity (BSCVA) following excimer laser photorefractive keratectomy (PRK). SETTING: Department of Ophthalmology, LSU Eye Center, and Refractive Surgery Center of the South, Ear, Nose & Throat Hospital, New Orleans, Louisiana; Manhattan Eye, Ear and Throat Hospital, New York, New York, USA. METHODS: Videokeratography data (TMS-1) were obtained preoperatively and 1, 3, 6, 12, 18, and 24 months postoperatively from 100 eyes having PRK for low to mild myopia. Algorithms measured fine local irregularity with the surface regularity index (SRIp), varifocality with the coefficient of variation of corneal power (CVPp), and central islands with the elevation/depression magnitude (EDM). RESULTS: The SRIp and CVPp increased after surgery and remained significantly higher than the preoperative levels throughout the 24 month follow-up (P < .05). The increase in EDM was significant from 1 to 6 months (P < .05) but not thereafter. Multiple regression analysis revealed that variables having a statistically significant relationship with postoperative BSCVA were CVPp and EDM at 1 month, CVPp at 3 months, and CVPp, haze, and age at 6 months. No statistically significant correlation between any measures of irregular astigmatism and BSCVA was found after 1 year of follow-up. CONCLUSION: The quantitative measures used in this study are sensitive methods by which irregular astigmatism after keratorefractive procedures can be classified, evaluated, and compared.

Algorithms↗

Corneal hydration and central islands after excimer laser photorefractive keratectomy.

PURPOSE: To determine whether uneven corneal surface hydration during excimer laser photorefractive keratectomy (PRK) is related to postoperative occurrence of central islands. SETTING: LSU Eye Center, New Orleans, Louisiana, USA. METHODS: A retrospective study reviewed intraoperative videotapes and postoperative videokeratography of 49 eyes of 49 patients who had excimer laser PRK for myopia. The uniformity of corneal hydration within the photoablation zone, particularly the frosty appearance of the ablated zone, was characterized. The presence or absence of a topographic central island (steepening of at least 3.0 diopters and 1.5 mm in diameter) was determined from the 1 month postoperative videokeratographs. RESULTS: Twelve eyes (24.5%) developed central islands postoperatively. A statistically significant association was observed between the uneven surface hydration (central accumulation of fluid) within the ablation zone intraoperatively and the formation of central islands postoperatively (P < .001, Kruskal-Wallis test; Kendall tau rank correlation = 0.534; P < .001). CONCLUSION: Nonuniform fluid distribution during photoablation was a risk factor for central island formation after PRK. Intraoperatively, the presence of excess fluid in the central cornea appeared as a shiny area. This mirror-like surface layer may reduce the rate of central ablation by reflecting and absorbing a significant amount of the incident excimer laser light.

Adult↗

Cinemakeratography using computer morphing.

PURPOSE: TMS-1 videokeratography (Tomey Technologies, Inc.) was animated using computer morphing to visualize corneal shape change over time. METHODS: Morphing was performed using keratoconus (8 examinations/76 months) and postoperative photorefractive keratectomy (PRK) corneas (8 examinations/37 months; LSU PRK Phase IIa). RESULTS: In the keratoconus animation, the inferior cone increased curvature, but not equally in all directions, nor at a constant rate. The cone apex did not drift over time. Periodic flattening and steepening was observed superiorly, as well as cone regression at month 76. The Keratoconus Prediction Index (KPI) at month 0 was 0.18, plateaued at 0.36 at month 46, and dropped to 0.33 at month 76. In the post-PRK animation there was continuous corneal remodeling out to 30 months. Fluctuating steep and flat regions of the ablation zone correlated with the Surface Regularity Index (SRI). CONCLUSION: Cinemakeratography (Cinema-K) enhanced our appreciation of subtle changes in corneal topography.

Cornea↗

Disparity between keratometry-style readings and corneal power within the pupil after refractive surgery for myopia.

PURPOSE: Because keratometry readings may no accurately reflect the refractive changes after keratorefractive surgery for myopia, better methods for the assessment of corneal curvature in the postsurgical cornea are needed. METHODS: We developed a procedure to calculate the average central power (ACP) of the cornea within the entrance pupil from videokeratography. Videokeratograph-derived keratometry-style readings (average K; K) and calculated ACPs, as well as the differences between the two values, were compared in four groups: normal corneas (n = 30), corneas with regular astigmatism (n = 30); post-radial keratotomy corneas (RK, n = 85), and post-excimer laser photorefractive keratectomy corneas (PRK, n = 63). Intraocular lens (IOL) powers calculated by using K or ACP in the Sanders-Retzlaff-Kraff formula were compared. RESULTS: In the groups with normal corneas or regular astigmatism, none of the eyes showed a difference between K and ACP > 0.25 D. However, six (7%) of the RK eyes and 16 (25%) of the PRK eyes had differences > 0.55 D; in these eyes, the disparity between IOL powers calculated by using K and IOL powers calculated by using ACP was > 0.5 D. CONCLUSION: These results suggest that basing the calculation of IOL powers on keratometry readings in patients who have undergone RK. PRK, or possibly other refractive procedures may result in a residual refractive error in some eyes. In particular, patients undergoing surgery involving a small optical zone or large attempted correction or both, as well as those with low postoperative keratometry readings, may be at risk for this problem if IOL placement becomes necessary in later years.

Cornea↗

Current keratoconus detection methods compared with a neural network approach.

PURPOSE: Four videokeratographic methods for keratoconus detection were compared with a neural network approach. METHODS: A classification neural network for keratoconus screening was designed to detect the presence of keratoconus (KC) or keratoconus suspects (KCS); a separate cone severity network graded the severity of conelike topography patterns consistent with KC or KCS. Three hundred TMS-1 examinations (Tomey) were randomly divided into training and test sets. Ten topographic indexes were network inputs. Nine categories were used: normal, astigmatism, KC, KCS, contact lens-induced warpage, pellucid marginal degeneration, photorefractive keratectomy, radial keratotomy, and penetrating keratoplasty. KC was subdivided into KC1 (mild), KC2 (moderate), and KC3 (advanced). There were three outputs for the classification network (KC, KCS, and OTHER); target output values of 0 = OTHER, 0.25 = KCS, 0.5 = KC1, 0.75 = KC2, and 1.0 = KC3 were used for the severity network. RESULTS: The best-trained classification network had 100% accuracy, specificity, and sensitivity for the test set. The severity network had mean outputs (+/-standard deviation) of OTHER = 0.02+/-0.02, KCS = 0.21+/-0.05, KC1 = 0.52+/-0.17, KC2 = 0.74+/-0.12, and KC3 = 0.91+/-0.15. The severity network output for all categories was well correlated to the keratoconus prediction index (R = 0.892, P < 0.0001). The classification network had an overall accuracy and specificity significantly better (P < or = 0.005) than the Klyce/Maeda keratoconus index (KCI) test, the Rabinowitz test (K & I-S), and simulated keratometry (average Sim K). However, there were no significant differences in keratoconus sensitivity between the classification network, KCI, and K & I-S. The sensitivity and specificity of average Sim K were significantly worse than those of the other tests. The classification network had significantly better sensitivity (P < 0.001) and specificity (P = 0.025) for KCS detection than the K & I-S. CONCLUSIONS: The neural networks completely distinguished KC from KCS and from topographies that resembled KC. The network approach equaled the sensitivity of currently used tests for keratoconus detection and outperformed them in terms of accuracy and specificity.

Cornea↗

Comparison of methods for detecting keratoconus using videokeratography.

BACKGROUND: The detection of keratoconus patterns on videokeratography is important for screening candidates for refractive surgery and for studying the genetic basis of keratoconus. OBJECTIVE: We compared three quantitative approaches to identifying keratoconus from videokeratographic information to examine the limitations and capabilities of each test and to determine their suitability for use in the clinical setting. METHODS: Videokeratographs typical of clinically diagnosed keratoconus (n = 44) and of various non-keratoconus conditions (n = 132, including normal, with-the-rule astigmatism, contact lens-induced corneal warpage, photorefractive keratectomy, keratoplasty, and pellucid marginal degeneration) were selected. Three methods for detecting keratoconus were used: keratometry (average Simulated Keratometry [SimK] readings > 45.7 diopters [D]); the modified Rabinowitz-McDonnell test (central corneal power > 47.2 D and/or Inferosuperior Asymmetry [I-S] value > 1.4 D); and an expert system classifier (classification based on discriminant analysis and classification tree with eight topographic indexes). Sensitivity and specificity were calculated for each test. RESULTS: Sensitivities were 84% for keratometry, 96% for the modified Rabinowitz-McDonnell test, and 98% for the expert system classifier. Specificities for the three methods were 86%, 85%, and 99%, respectively. In terms of sensitivity, the expert system classifier was significantly better than keratometry (P = .04). In terms of specificity, the expert system classifier was significantly better than either of the other methods (P = .001). CONCLUSIONS: For screening candidates for refractive surgery, where high sensitivity is needed, either the modified Rabinowitz-McDonnell test or the expert system classifier is suitable. For diagnosing keratoconus, where high specificity is more useful, the expert system classifier is more appropriate than the other two methods.

Cornea↗

Neural network classification of corneal topography. Preliminary demonstration.

PURPOSE: Videokeratography is a powerful tool for the diagnosis of corneal shape abnormalities. However, interpretation of the topographic map is sometimes difficult, especially when pathologies with similar topographic patterns are suspected. The neural networks model, an artificial intelligence approach, was applied for automated pattern interpretation in corneal topography, and its usefulness was assessed. METHODS: One hundred eighty-three topographic maps were selected and classified by human experts into seven categories: normal, with-the-rule astigmatism, keratoconus (mild, moderate, advanced), postphotorefractive keratectomy, and postkeratoplasty. The maps were divided into a training set (108 maps) and a test set (75 maps). For each map, 11 topography-characterizing indices calculated from the data provided by the TMS-1 videokeratoscope, plus the corresponding diagnosis category, were used to train a neural network. RESULTS: The correct classification was achieved by a trained neural network for all 108 maps in the training set. In the test set, the neural network correctly classified 60 of 75 maps (80%). For every category, accuracy and specificity were greater than 90%, whereas sensitivity ranged from 44% to 100%. CONCLUSIONS: With further testing and refinement, the neural networks paradigm for computer-assisted interpretation or objective classification of videokeratography may become a useful tool to aid the clinician in the diagnosis of corneal topographic abnormalities.

Cornea↗

Holographic interferometry of intact and radially incised human eye-bank corneas.

Many methods to measure corneal elasticity destroy the tissue and thereby produce erroneous results. Holographic interferometry, a highly precise nondestructive optical comparison technique, was used to evaluate corneal elasticity of intact eye-bank eyes. A double-pulse holographic interferometer operating at 632.8 nm was used to measure corneal deformation in 20 whole-globe eyes from donors 45 to 83 years of age for intraocular pressures from 16 mm Hg to 21 mm Hg. Stress was computed from LaPlace's law, and arc length strain was derived from z-axis distention of the central cornea. The stress-strain relationship in the normal physiological range of intraocular pressure was linear with a Young's elastic modulus of 1.03 gigapascals for the central cornea (r = 0.999). During interferometry of radial keratotomy of the cornea, interference fringe patterns developed in association with each incision as it was made. When four incisions were placed deep along each of the primary semimeridians, the fringe pattern developed as expected, based on current keratotomy models. When incisions were shallow (approximately 50% depth) and placed asymmetrically along the nasal, temporal, and superior semimeridians, the resulting surface strain was symmetrical about the central cornea, forming an annular pattern of interference fringes. These results indicate that when the cornea was stressed at physiological pressures as part of the intact whole globe, it was less elastic than excised corneal tissue tested by strip extensiometry. Radially incised corneas demonstrated strain patterns suggestive of inherent structural anisotropy with a possible inferior quadrant weakness.

Adult↗

Keratoconus and contact lens-induced corneal warpage analysis using the keratomorphic diagram.

PURPOSE: Videokeratography of early keratoconus may be difficult to distinguish from contact lens-induced corneal warpage, even by experienced examiners. Furthermore, topographic irregularity may be judged inconsistently if quantitative standards are not applied. Quantitative measures based on videokeratographic data were developed and evaluated to determine if improved corneal topographic classification can be achieved. METHODS: The Corneal Irregularity Coefficient (CIC) and Corneal Power Coefficient (CPC) were derived from multiple measures of mean corneal power and its variance for 207 videokeratographs of normal, warped, keratoconus, and keratoconus-suspect corneas. CIC was plotted against CPC, creating a distribution of points representing all maps that tended to be grouped according to surface conditions (the Keratomorphic Diagram). Normal, steep, abnormal, and warped zones were defined by CIC and CPC cutoff values chosen to distinguish normal from keratoconus corneas graphically. RESULTS: Seventy of 76 normal corneas were grouped in the normal zone and 6 in the steep zone; 84 of 84 keratoconus corneas were grouped in the abnormal zone; 35 of 35 contact lens-induced warpage cases were grouped in the warped zone; and 10 of 12 keratoconus-suspect corneas were grouped in the warped zone, with 2 in the abnormal zone. Serially plotted data of keratoconus progression and warpage regression demonstrated that the vector displacement of CIC and CPC values may provide a potentially useful means of distinguishing contact lens-induced warpage from keratoconus-suspect corneas. CONCLUSION: The Keratomorphic Diagram aids in classifying and comparing corneal shape by plotting indices along axes with easily recalled scales. The diagram may become a useful tool to assess presurgical corneal surface instability and postoperative progression of corneal shape change due to healing.

Contact Lenses↗

Automated keratoconus screening with corneal topography analysis.

PURPOSE: Although visual inspection of corneal topography maps by trained experts can be powerful, this method is inherently subjective. Quantitative classification methods that can detect and classify abnormal topographic patterns would be useful. An automated system was developed to differentiate keratoconus patterns from other conditions using computer-assisted videokeratoscopy. METHODS: This system combined a classification tree with a linear discriminant function derived from discriminant analysis of eight indices obtained from TMS-1 videokeratoscope data. One hundred corneas with a variety of diagnoses (keratoconus, normal, keratoplasty, epikeratophakia, excimer laser photorefractive keratectomy, radical keratotomy, contact lens-induced warpage, and others) were used for training, and a validation set of 100 additional corneas was used to evaluate the results. RESULTS: In the training set, all 22 cases of clinically diagnosed keratoconus were detected with three-false-positive cases (sensitivity 100%, specificity 96%, and accuracy 97%). With the validation set, 25 out of 28 keratoconus cases were detected with one false-positive case, which was a transplanted cornea (sensitivity 89%, specificity 99%, and accuracy 96%). CONCLUSIONS: This system can be used as a screening procedure to distinguish clinical keratoconus from other corneal topographies. This quantitative classification method may also aid in refining the clinical interpretation of topographic maps.

Cornea↗

Corneal topography of excimer laser photorefractive keratectomy.

The application of the 193 nm excimer laser for keratorefractive surgery promises to deliver a higher degree of precision and predictability than traditional procedures such as radial keratotomy. The development and evaluation of keratorefractive surgery have benefited from the parallel advances made in the field of corneal topography analysis. We used the Computed Anatomy Topography Modeling System (TMS-1) to analyze a Louisiana State University (LSU) Eye Center series of patients who had photorefractive keratectomy for the treatment of myopia with the VISX Twenty/Twenty excimer laser system. The excimer ablations were characterized by a relatively uniform distribution of surface powers within the treated zone. In the few cases that exhibited marked refractive regression, corneal topography analysis showed correlative changes. With topographical analysis, centration of the ablations relative to the center of the pupil could be evaluated. Marked improvement in centration occurred in the patients of LSU Series IIB in which the procedure to locate the point on the cornea directly over the pupil's center during surgery was refined. Corneal topographical analysis provides objective measures of keratorefractive surgical results and is able to measure the precise tissue removal effect of excimer laser ablation without the uncertainties caused by measuring visual acuity alone. Our observations forecast the need for improved aids to center the laser ablations and for the development of a course of treatment to prevent post-ablation stromal remodeling.

Cornea↗