PubMed Health⌕ Search

Biomedical subjects

M K Stenstrom

Publications and source records attributed to M K Stenstrom.

13 recordsLinked to original sources

Degradation kinetics and mechanism of RDX and HMX in TiO2 photocatalysis.

This study was undertaken to examine the photocatalytic degradation of explosives hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) with a circular photocatalytic reactor, using a UV lamp as a light source and TiO2 as a photocatalyst. The effects of various parameters, such as the RDX or HMX concentration, the amount of TiO, and the initial pH, on the photocatalytic degradation rates of explosives were examined. In the presence of both UV light and TiO2 RDX and HMX were more effectively degraded than with either UV or TiO2 alone. The degradation rates were found to obey pseudo-first-order kinetics represented by the Langmuir-Hinshelwood model. Increases in the RDX and HMX degradation rates were obtained with decreasing initial concentrations of the explosives. The RDX and HMX degradation rates were higher at pH 7 than at either pH 3 or pH 11. A dose of approximately 0.7 g l(-1) of TiO2 degraded HMX more rapidly than did higher or lower TiO2 doses. RDX (20 mg l(-1)) photocatalysis resulted in an approximately 20% decrease in TOC, and HMX (5 mg l(-1)) photocatalysis resulted in a 60%, decrease in TOC within 150 minutes. A trace amount of formate was produced as an intermediate that was further mineralized by RDX or HMX photocatalysis. The nitrogen byproducts from the photocatalysis of RDX and HMX were mainly NO3- with NO2-, and NH4+. The total nitrogen recovery was about 60% from RDX (20 mg l(-1)), and 70% from HMX (5 mg l(-1)), respectively. Finally, a mechanism for RDX/HMX photocatalysis was proposed, along with supporting qualitative and quantitative evidence.

Azocines↗

Characteristics of litter waste in highway storm runoff.

Litter characterization is an integrated part of the Caltrans First Flush Characterization Study. These data will provide a basis to develop potential treatment technologies and best management practices to control pollutants in runoff from freeways. During monitoring periods in Southern California areas, the first flush phenomenon was evaluated and the impacts of various parameters such as rain intensity, drainage area, peak flow rate, and antecedent dry period on litter volume and loading rates were evaluated. First flush phenomenon was generally observed for litter concentrations, but was not apparent with litter mass loading rates. Total captured gross pollutants, defined as larger than 0.5 cm, was 90% vegetation with only 10% being litter. The normalized cumulative litter loadings were determined from 1.25 to 13.39 kg/ha for dry litter weight and 0.40 to 8.99 kg/ha for dry biodegradable litter weight. The portions of biodegradable litter to non-biodegradable litter were roughly the same across the entire event. Event mean concentrations were ranged 0.0021 to 0.259 g/L for wet gross pollutants, 0.0001 to 0.027 g/L for wet litters and 0.00007 to 0.018 g/L for dry litters. The mass emission rates should be useful to estimate total litter production for developing total maximum daily loads.

Air Pollutants↗

Correlation analysis among highway stormwater pollutants and characteristics.

Stormwater runoff from highway land use is a common non-point source of pollutants. A large quantity of highway stormwater runoff characteristics were collected in California during the past three years. Correlations among various water quality parameters and constituents were performed using data sets collected over the 2000-2001, 2001-2002, and 2002-2003 wet seasons for 18, 21 and 23 storm events at three highway sites in west Los Angeles, California. In addition, statistical and graphical correlation analysis of the mass first flush ratio (MFF) with storm characteristics was made to determine if the first flush is related to site or storm characteristics. The results and analyses performed indicate that (1) TSS correlates well with most particulate-bound metals. However, TSS was poorly correlated with most other pollutants. (2) Strong correlations were also observed among dissolved and total metals; DOC, COD, TKN and oil and grease; conductivity and Cl. (3) Total metals, COD and DOC were generally well correlated with mass first flush, suggesting that BMPs that treat the early portion of runoff have an opportunity to remove high concentrations of these pollutants.

Air Pollutants↗

Surfactant effects on alpha factors in full-scale wastewater aeration systems.

Aeration is an essential process in the majority of wastewater treatment processes, and accounts for the largest fraction of plant energy costs. Aeration systems can achieve wastewater oxygenation by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactants accumulate on gas-liquid interfaces and reduce mass transfer rates. This reduction in general is larger for fine-bubble aerators. This study was conducted to evaluate mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes were analysed, showing higher gas transfer depression for lower turbulence regimes. Higher turbulence regimes can offset contamination effects, at the expense of operating efficiency. This phenomenon is characteristic of surface aerators and coarse bubble diffusers and is here discussed. The results explain the variability of alpha factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations that describe mass transfer as a function of physiochemical and geometrical characteristics of the aeration process.

Bioreactors↗

Greenhouse gas production: a comparison between aerobic and anaerobic wastewater treatment technology.

Anaerobic wastewater treatment offers improved energy conservation with potential reduction in greenhouse gas emissions. Pitfalls exist in that the methane produced in anaerobic treatment can offset any reductions in carbon dioxide emissions, if it is released to the environment. This paper analyzes greenhouse gas emissions from both aerobic and anaerobic treatment systems, including sludge digestion and the losses of dissolved methane in digested biosolids and process effluents. There exists cross over points, ranging from 300 to 700 mg/L influent wastewater BODu, which are functions of the efficiency of the aerobic treatment system. Anaerobic treatment becomes favorable when treating influents higher in concentrations than the cross over values. A technology to recover dissolved methane would make anaerobic treatment favorable at nearly all influent strengths.

Aerobiosis↗

A new modeling approach for estimating first flush metal mass loading.

The purpose of this study was to investigate pollutant mass loading from major highways in Southern California, with emphasis on interpretation of event mean concentrations and first flush effects. The results of monitoring eight sites during the 1999-2002 storm seasons found that metal contaminants had higher concentrations at the early stages of storm events compared with other stages of rain storms. A new washoff model was developed to predict the event mean concentrations of metal contaminants taking first flush effect into account. Model variable parameters included average daily traffic, antecedent dry period, rain intensity, total runoff volume, and runoff coefficient. The results obtained using the washoff model were compared with measured values and found to fit well for heavy metals with R2 ranging from 0.8 to 0.95.

California↗

Comparison of the pollutant loads in dry and wet weather runoff in a southern California urban watershed.

This research compares the relative contributions of potential contaminants discharged in dry weather flow (DWF) and wet weather flow (WWF) from the highly urbanized Ballona Creek watershed (BCW) in southern California using empirical and deterministic models. These models were used to compare the loading of the following pollutants: total suspended solids, biochemical oxygen demand, total nitrogen, total inorganic nitrogen, total Kjeldahl nitrogen, total phosphorus, copper, lead, arsenic, nickel, cadmium, and chromium. The results indicate DWF contributes approximately 10-30% of the total annual flow discharged from Ballona Creek. The annual DWF volume was fairly consistent; the variation in DWF percentage contribution was dependent on the highly variable volume of WWF. The relative contribution to the annual pollutant load varied considerably between each pollutant. In general, the DWF load was found to be significant, especially in years with lower precipitation totals. The results from this investigation have identified the relative relationship between DWF and WWF loads in the BCW and will aid in the decision-making process during the development of an integrated DWF-WWF management plan and allocation of water pollution control funds between DWF and WWF management.

California↗

Evaluation of urban non-point source runoff of hazardous metals entering Santa Monica Bay, California.

Significant amounts of non-point source runoff enter the Santa Monica Bay from the Ballona Creek Watershed during wet weather flow. The primary objective of this study was to determine the concentrations of hazardous metal pollutants associated with the aqueous and suspended solid phases during wet weather flow. A calculation of the mass of the pollutants for each storm was conducted. Other objectives of this study were to evaluate during a storm event the relationships between (1) soluble and sorbed metals, (2) storm flow and pollutant loading, including a determination if a first flush was present, and (3) total mass loading of pollutants and relative pollution loading from three watershed sub-basins. This study focused on the urbanized watershed of Ballona Creek, which is approximately 330 km2 (127 miles2) in size and developed primarily with residential and light commercial industries. In the 1997-98 rain season, an El Niño year, two storm events were monitored by the collection of hourly grab samples. An initial storm monitored Ballona creek, while a second storm also monitored Ballona Creek along with two smaller sub-watersheds, Centinela Channel and Sepulveda Channel. The results indicated the suspended solids phase primarily transported the mass for five of the six hazardous metals studied: cadmium, chromium, copper, lead, and nickel. Arsenic was found primarily in the aqueous phase.

California↗

Catch basin inserts to reduce pollution from stormwater.

Stormwater contamination represents the largest source of contaminants to many receiving waters in the United States, such as Santa Monica Bay in Los Angeles, California. Point sources to these same waters generally receive secondary or better treatment before they are released, and they are usually discharged through outfalls that diffuse the wastewater plume to prevent it from contacting the shoreline. Stormwaters receive no treatment and reach the receiving waters through a variety of ways, but most enter through catch basins or inserts to storm drains that terminate at the beach or in shallow coastal areas. Under these conditions, the stormwater discharge may have greater impact on the quality and utility of the receiving water than the treated wastewater discharges. One method of reducing pollution is to equip catch basins with an insert that can capture pollutants. A number of commercially available devices exist but few have been evaluated by independent parties in full-scale applications. A series of tests using bench and full-scale devices under both laboratory and field conditions were conducted to evaluate their ability to remove trash and debris, suspended solids and oil and grease in stormwaters. The results presented in the paper should provide a basis for future insert development and application.

Cities↗

Relationship between oxygen transfer rate and airflow for fine-pore aeration under process conditions.

Although feedback systems that control the air supply to aeration tanks inherently incorporate some assumption about oxygen transfer response to changes in airflow, it is rare to measure this relationship under process conditions. This paper reports measurements of oxygen mass-transfer curves (MTCs) for a tank at the Tillman Water Reclamation Plant in Los Angeles, California. The curves were obtained by measuring the oxygen transfer efficiency (OTE) at selected points for several set values of airflow while the plant was operating. They approximate inverted parabolas because increasing the airflow increases the amount of oxygen supplied by the blowers, but decreases the OTE, which is the fraction of the supplied oxygen that actually enters the water. Data were recorded from both recently cleaned diffusers and ones that were moderately to severely fouled. The peaks in the curves from the fouled diffusers are at or below the midpoints of the observed ranges of airflows. Hence, there is only a narrow range of usable airflows between the lower limit, determined by the manufacturer of the diffusers, and the peak of the MTC, which is the maximum amount of oxygen that can be supplied. The peaks for the cleaned diffusers are higher, which allows more ability to adjust to changing biological loads. These results show that existing dissolved oxygen control systems may not be adequate and that fouling may reduce not only the overall efficiency of an aeration system but its ability to respond to changes in the biological load. The measurements also provide some insight to the limitations of using sparsely distributed dissolved oxygen sensors to control the aeration process and the excess costs that are incurred by the consequent need to compensate for uncertainty with extra air. However, additional testing is needed to determine whether the present results are aberrant or typical of tanks with fouled or cleaned diffusers.

Air Movements↗

Use of biodegradable dissolved organic carbon to assess treatment process performance in relation to solids retention time.

A biodegradable dissolved organic carbon (BDOC) method has been developed and used to analyze secondary- and advanced-treated wastewater effluents and to investigate correlations between residual organic content and the solids retention time (SRT). Conventional biochemical oxygen demand (BOD) bottles and a 28-day incubation period were used. Secondary wastewater effluents from Hawaii were found to contain between 9.0 and 14.0 mg/L of dissolved organic carbon (DOC), of which 23 to 35% was biodegradable in the 28-day BDOC test (from a survey of nine treatment plants). Bench-scale, continuous-flow activated-sludge biological reactors treating synthetic wastewater were operated at SRTs between 2 and 15 days, and effluent BDOCs were determined. A good BDOC prediction equation was developed that incorporates the initial DOC, the DOC remaining after 5 days, and the SRT of the system from which the sample originated. This equation can be used to determine the BDOC value using data that can be obtained during a conventional 5-day BOD test. The determined equation was found to be appropriate for some of the full-scale wastewater effluent survey data.

Biodegradation, Environmental↗

Changing mesophilic wastewater sludge digestion into thermophilic operation at Terminal Island Treatment Plant.

This paper describes the progress up to June 2000 for thermophilic digestion of wastewater sludge at the Los Angeles, California, Bureau of Sanitation's Terminal Island Treatment Plant. The development of the microorganism culture has followed a course similar to that seen at other successful plants for establishment of a stable, well-balanced thermophilic culture in a large digester, but at an accelerated pace. This study began with rapid heating, increasing the temperature of the 4500 m3 (1.2 mil. gal) digester to the target temperature of 55 degrees C at approximately 3 degrees C/d. A method of feeding to maximize the rate of culture development was used as feeding accelerated to approximately 400 m3/d (0.1 mgd). An initial rise of acid concentration (primarily acetate) was seen. Within two weeks, acid concentration declined and stabilized, indicating that acidogenic and methanogenic microbial communities came into balance. Coliform data indicate that digester disinfection was stably effective from the middle of April. The salmonella tests done to date satisfy the U.S. Environmental Protection Agency (U.S. EPA) class A specification. Testing with helminth ova and enteric viruses before and after the digester shows satisfaction of class A standard for those organisms. The present combination of low volatile fatty acids and low hydrogen sulfide is good news for odor control. The data show increases in volatile solids destruction and estimated gas production, compared with the previous mesophilic operation; however, large uncertainties have been calculated from the data. As the digester is now operating successfully at the current feed rate, there seems to be no barriers to processing the entire sludge production of the plant. Other results indicate that the U.S. EPA requirements for exceptional quality class A biosolids are likely to be achieved.

Animals↗

Fifteen years of offgas transfer efficiency measurements on fine-pore aerators: key role of sludge age and normalized air flux.

Fine-pore diffusers, often called fine-bubble diffusers, have nearly replaced coarse bubble diffusers in municipal wastewater treatment over the past 20 years. The rapid increases in energy costs, which began in the 1970s, created financial incentives to upgrade to this more expensive and maintenance-intensive method of aeration. Fine-pore diffusers have the added benefit of reducing volatile organic compound stripping and reduced aeration heat loss. This paper summarizes 15 years of oxygen transfer efficiency measurements using the offgas technique. Efficiencies are shown for different types of diffusers at various tank geometries (depth, diffuser size, and number), airflow rates, and mean cell retention times (MCRT or sludge age). By normalizing the airflow rates per unit of depth and diffusing area, efficiencies measured in different plants can be compared. The results show that aeration efficiencies are logarithmically related to the ratio between MCRT and the normalized air flux, with transfer rates suppressed by low MCRT or high normalized air flux systems. There is no evidence for different alpha factors among the different types of fine-bubble diffuser types.

Air Movements↗