PubMed Health⌕ Search

Biomedical subjects

M Kane

Publications and source records attributed to M Kane.

At least 37 records · Page 2Linked to original sources

Effect of NASA light-emitting diode irradiation on wound healing.

OBJECTIVE: The purpose of this study was to assess the effects of hyperbaric oxygen (HBO) and near-infrared light therapy on wound healing. BACKGROUND DATA: Light-emitting diodes (LED), originally developed for NASA plant growth experiments in space show promise for delivering light deep into tissues of the body to promote wound healing and human tissue growth. In this paper, we review and present our new data of LED treatment on cells grown in culture, on ischemic and diabetic wounds in rat models, and on acute and chronic wounds in humans. MATERIALS AND METHODS: In vitro and in vivo (animal and human) studies utilized a variety of LED wavelength, power intensity, and energy density parameters to begin to identify conditions for each biological tissue that are optimal for biostimulation. RESULTS: LED produced in vitro increases of cell growth of 140-200% in mouse-derived fibroblasts, rat-derived osteoblasts, and rat-derived skeletal muscle cells, and increases in growth of 155-171% of normal human epithelial cells. Wound size decreased up to 36% in conjunction with HBO in ischemic rat models. LED produced improvement of greater than 40% in musculoskeletal training injuries in Navy SEAL team members, and decreased wound healing time in crew members aboard a U.S. Naval submarine. LED produced a 47% reduction in pain of children suffering from oral mucositis. CONCLUSION: We believe that the use of NASA LED for light therapy alone, and in conjunction with hyperbaric oxygen, will greatly enhance the natural wound healing process, and more quickly return the patient to a preinjury/illness level of activity. This work is supported and managed through the NASA Marshall Space Flight Center-SBIR Program.

Animals↗

Phylogenetic analysis of picoplankton in Lake Biwa and application to legal medicine.

Three strains of picoplankton designated as brown, green, and pink belonging to the Synechococcus genus in cyanobacteria (approximately 1 microm in size) are found ubiquitously in Lake Biwa, Japan. However, they could not be morphologically discriminated from other bacteria such as Proteobacteria and Bacillus by microscopy. In this study, we attempted to use the polymerase chain reaction (PCR) analysis of the 16S ribosomal DNA (rDNA) from picoplankton for the diagnosis of death by drowning. A segment of 16S rDNA was sequenced in order to investigate their phylogenetic relationships and to design the specific primers. The PCR products from three picoplanktons were compared with those from five other cyanobacteria, Melosira (diatom), Staurastrum (green alga), bacteria from Lake Baikal, and humans. The picogram order of template DNA from picoplankton was specifically amplified by the primers. When the template of picoplankton was mixed with human tissue, at least 10 ng of template DNA was needed to obtain a PCR product. The efficiency of PCR was increased more than hundredfold by isolating the picoplankton from human lung tissue. The specific PCR products of the picoplankton were obtained from a formalin-fixed drowning body (lung and liver) that was found in a downstream river and Lake Biwa. The PCR analysis of the picoplanktion 16S rDNA is considered useful for the diagnosis of death by drowning.

Cyanobacteria↗

Rapid polymerase chain reaction/DNA probe membrane-based assay for the detection of Listeria and Listeria monocytogenes in food.

We describe the development of polymerase chain reaction (PCR)/DNA probe membrane-based colorimetric assays for the detection and identification of Listeria and L. monocytogenes. PCR primers designed from the 16S to 23S rRNA intergenic spacer region amplified products that were reverse hybridized to membrane-bound oligonucleotide probes specific for Listeria and L. monocytogenes with a detection limit of 1 to 10 CFU/25 ml in inoculated raw and pasteurized milk samples. These qualitative assays have the potential to be integrated into testing laboratories for monitoring the microbiological quality of foods.

Animals↗

The value of case management in the publicly funded substance abuse treatment system. The perspective of program directors, case managers and clients.

The many purposes of this article is to understand the role and value of case management from the perspective of program directors, case managers and clients. A survey of program directors from publicly funded substance abuse treatment programs in Boston was administered, and in-depth interviews with a sample of program directors, case managers, and clients were conducted. Case management allowed programs to serve more complex clients and increased time available for counselors to focus on the clinical needs of clients. From the perspective of case managers and clients, much of the value of case management came from educating clients about steps they could take to meet their needs and then supporting them in their efforts as they took these steps. Successful steps taken to deal with these needs helped lay the foundation necessary to confront the challenges of treatment. Program directors, case managers, and clients considered case management a valuable enhancement to substance abuse treatment.

Attitude of Health Personnel↗

Exploring lay definitions of asthma and interpersonal barriers to care in a predominantly Puerto Rican, inner-city community.

Lay definitions of asthma were elicited through a single open-ended question from a population-based sample of mostly Puerto Rican, inner-city residents in Buffalo, New York. One hundred fifty-five household responses to the question, "What do you think asthma is?" were analyzed qualitatively using the editing approach. Five common codes emerged in order of significance: "symptoms," "disease," "triggers," "threat," and "coping." Overall, expressions of illness reflected a largely symptomatic perception of asthma regardless of asthma status. Perceptions of "disease" increased with higher level of education. Patients' definitions of illness should be considered to help reduce interpersonal barriers to asthma care.

Adaptation, Psychological↗

The middle ear bioelectronic microphone for a totally implantable cochlear hearing device for profound and total hearing loss.

BACKGROUND: A bioelectronic middle ear microphone (BMEM) has been developed in a laboratory bench model and successfully tested in fresh human temporal bones. A transducer actually has been bench-tested in our laboratory; it was implanted in chronic animal experiments (cats) as well as in humans for a period of 1 year as a driver of a semi-implantable electromagnetic middle ear hearing device (IDE, FDA approved). This BMEM is the result of the use of this same electromagnetic transducer used in a reverse mode. The applicability of the BMEM is for the development of a totally implantable cochlear implant using the eardrum as a diaphragm that transmits vibrations to a magnet cemented to the ossicles. This BMEM is to be powered by a lithium-ion implantable, rechargeable battery. MATERIALS AND METHODS: To test the efficacy of this BMEM, the experiment was divided into two parts: (1) bench model, and (2) fresh human temporal bones, using an air-core electromagnetic (EM) coil and a ferrite core EM coil for comparison. RESULTS: In the bench model, the average displacement at 3 kHz was 0.95 microns (peak) for 4 V p-p and 1.65 microns (peak) for 10 V p-p. At 5 kHz, the measurements were somewhat higher. In fresh human temporal bones, with sound source in the ear canal (60 dB HL and 90 dB HL), the result was better with the magnet implanted on the head of the malleus with the incus removed. The ferrite core EM coil with the magnet implanted on the malleus with the incus removed was compared with the air-core EM coil. At 60 dB HL, the ferrite core EM coil yielded more than four times the amplitude of the EM coil. At 90 dB HL, the ferrite core EM coil produced more than five times the amplitude compared with the air-core coil. CONCLUSION: This BMEM using an EM ferrite coil and a permanent magnet on the head of the malleus is more efficient when compared with an EM air-core coil. This BMEM may be applicable to the construction of a totally implantable cochlear implant. Further research is necessary to integrate this BMEM with the other components of the design concept of the totally implantable cochlear implant.

Animals↗

Unsafe injections in the developing world and transmission of bloodborne pathogens: a review.

Unsafe injections are suspected to occur routinely in developing countries. We carried out a literature review to quantify the prevalence of unsafe injections and to assess the disease burden of bloodborne infections attributable to this practice. Quantitative information on injection use and unsafe injections (defined as the reuse of syringe or needle between patients without sterilization) was obtained by reviewing the published literature and unpublished WHO reports. The transmissibility of hepatitis B and C viruses and human immunodeficiency virus (HIV) was estimated using data from studies of needle-stick injuries. Finally, all epidemiological studies that linked unsafe injections and bloodborne infections were evaluated to assess the attributable burden of bloodborne infections. It was estimated that each person in the developing world receives 1.5 injections per year on average. However, institutionalized children, and children and adults who are ill or hospitalized, including those infected with HIV, are often exposed to 10-100 times as many injections. An average of 95% of all injections are therapeutic, the majority of which were judged to be unnecessary. At least 50% of injections were unsafe in 14 of 19 countries (representing five developing world regions) for which data were available. Eighteen studies reported a convincing link between unsafe injections and the transmission of hepatitis B and C, HIV, Ebola and Lassa virus infections and malaria. Five studies attributed 20-80% of all new hepatitis B infections to unsafe injections, while three implicated unsafe injections as a major mode of transmission of hepatitis C. In conclusion, unsafe injections occur routinely in most developing world regions, implying a significant potential for the transmission of any bloodborne pathogen. Unsafe injections currently account for a significant proportion of all new hepatitis B and C infections. This situation needs to be addressed immediately, as a political and policy issue, with responsibilities clearly defined at the global, country and community levels.

Adult↗

Transmission of hepatitis B, hepatitis C and human immunodeficiency viruses through unsafe injections in the developing world: model-based regional estimates.

Thousands of millions of injections are delivered every year in developing countries, many of them unsafe, and the transmission of certain bloodborne pathogens via this route is thought to be a major public health problem. In this article we report global and regional estimates of the number of hepatitis B virus (HBV), hepatitis C virus (HCV) and human immunodeficiency virus (HIV) infections that may occur from unsafe injections in the developing world. The estimates were determined using quantitative data on unsafe injection practices, transmission efficiency and disease burden of HBV, HCV and HIV and the prevalence of injection use obtained from a review of the literature. A simple mass-action model was used consisting of a generalized linear equation with variables accounting for the prevalence of a pathogen in a population, susceptibility of a population, transmission efficiency of the pathogen, proportion of injections that are unsafe, and the number of injections received. The model was applied to world census data to generate conservative estimates of incidence of transmission of bloodborne pathogens that may be attributable to unsafe injections. The model suggests that approximately 8-16 million HBV, 2.3-4.7 million HCV and 80,000-160,000 HIV infections may result every year from unsafe injections. The estimated range for HBV infections is in accordance with several epidemiological studies that attributed at least 20% of all new HBV infections to unsafe injections in developing countries. Our results suggest that unsafe injections may lead to a high number of infections with bloodborne pathogens. A major initiative is therefore needed to improve injection safety and decrease injection overuse in many countries.

Cross Infection↗

Forces required to initiate sliding in second-generation intramedullary nails.

Second-generation intramedullary nails, which allow the fixation screw that is placed in the femoral head to slide distally and thus allow compression of the fracture of the femoral neck, have become a popular option for the treatment of ipsilateral fractures of the femoral neck and shaft. However, the sliding characteristics of the screw within the barrel of the nail or the side-plate have not been assessed biomechanically, to our knowledge. The goal of the current study was to investigate the forces required to initiate sliding of the proximal screw in intramedullary devices and to compare these forces with those required to initiate sliding of hip screws. The loading configuration simulated the typical angle of 135 degrees between the intramedullary nail and the proximal screw. The forces required to initiate sliding of the proximal screw, with the screw extended fifty-one, seventy-six, eighty-six, and 102 millimeters beyond the proximal end of the barrel, were measured for three different types of second-generation intramedullary nails (Recon, ZMS, and Gamma), a sliding compression hip screw, and an intramedullary hip screw, and these forces were then compared. With each amount of extension of the screw, the hip screws required lower forces to initiate sliding than did the second-generation intramedullary devices. Of the second-generation devices, the Gamma nail required the highest forces to initiate sliding; the Recon and ZMS nails required 20 to 40 percent lower forces compared with the Gamma nail. None of the devices jammed in any of the loading configurations that were tested. When the extension of the screw was increased, higher forces were required to initiate sliding.

Biomechanical Phenomena↗