PubMed Health⌕ Search

Biomedical subjects

M Klarhöfer

Publications and source records attributed to M Klarhöfer.

5 recordsLinked to original sources

High-resolution blood flow velocity measurements in the human finger.

MR phase contrast blood flow velocity measurements in the human index finger were performed with triggered, nontriggered, and cine acquisition schemes. A strong (G(max) = 200 mT/m), small bore (inner diameter 12 cm) gradient system inserted in a whole body 3 Tesla MR scanner allowed high-resolution imaging at short echo times, which decreases partial volume effects and flow artifacts. Arterial blood flow velocities ranging from 4.9-19 cm/sec were measured, while venous blood flow was significantly slower at 1.5-7.1 cm/sec. Taking into account the corresponding vessel diameters ranging from 800 microm to 1.8 mm, blood flow rates of 3.0-26 ml/min in arteries and 1.2-4.8 ml/min in veins are obtained. The results were compared to ultrasound measurements, resulting in comparable blood flow velocities in the same subjects. Magn Reson Med 45:716-719, 2001.

Blood Flow Velocity↗

In vivo magnetic resonance micro-imaging of the human toe at 3 Tesla.

The feasibility of in vivo high-resolution magnetic resonance micro-imaging of fine anatomic structures of human toes was tested. Five healthy subjects were investigated on an experimental 3 Tesla whole body scanner, using standard 3D gradient echo sequences. A radio-frequency surface coil was used for signal detection. Feet, toes and surface coil were comfortably fixed using a home built device for positioning and reduction of motion artifacts. The spatial resolution of 117 x 313 x 375 microm(3) allowed detailed visualization of anatomic structures like skin layers, vessels and nerves. In addition, oval structures with diameters ranging from 500 to 1000 microm were observed in all subjects, which could represent the sensory nerve endings of Vater-Pacinian bodies. Thus, high resolution MR micro-imaging at 3 Tesla may provide improved morphologic information in distal extremities of humans in vivo.

Adult↗

Functional MRI of the human motor cortex using single-shot, multiple gradient-echo spiral imaging.

In this study, we combined the advantages of a fast multi-slice spiral imaging approach with a multiple gradient-echo sampling scheme at high magnetic field strength to improve quantification of BOLD and inflow effects and to estimate T2* relaxation times in functional brain imaging. Eight echoes are collected with echo time (TE) ranging from 5 to 180 ms. Acquisition time per slice and echo time is 25 ms for a nominal resolution of 4 x 4 x 4 mm3. Evaluation of parameter images during rest and stimulation yields no significant activation on the inflow sensitive spin-density images (rho or I0-maps) whereas clear activation patterns in primary human motor cortex (M1) and supplementary motor area (SMA) are detected on BOLD sensitive T2*-maps. The calculation of relaxation times and rates of the activated areas over all subjects yields an average T2* +/- standard deviation (SD) of 46.1+/-4.5 ms (R2* of 21.8+/-2.2 s(-1)) and an average increase (deltaT2* +/- SD) of 0.93+/-0.47 ms (deltaR2* of -0.4+/-0.14 s(-1)). Our findings demonstrate the usefulness of a multiple gradient echo data acquisition approach in separating various vascular contributions to brain activation in fMRI.

Adult↗

Characterization of BOLD activation in multi-echo fMRI data using fuzzy cluster analysis and a comparison with quantitative modeling.

A combination of multiple gradient-echo imaging and exploratory data analysis (EDA), i.e. fuzzy cluster analysis (FCA), is proposed for separation and characterization of BOLD activation in single-shot spiral functional magnetic resonance imaging (fMRI) experiments at 3 T. Differentiation of functional activation using FCA is performed by clustering pixel signal changes (DeltaS) as a function of echo time (TE). Further vascular classification is supported by the localization of activation and the comparison with a single-exponential decay model. In some subjects, an additional indication for large vessels within a voxel was found as oscillation of the fMRI signal difference vs echo time (TE). Such large vessels may be separated from small vessel activation and, therefore, our proposed procedure might prove useful if a more specific functional localization is desired in fMRI. In addition to the signal change DeltaS, DeltaT(2)*/T(2)* is significantly different between activated regions. Averaged over all eight subjects DeltaT(2)* is 1.7 +/- 0.2 ms in ROIs with the highest signal change characterized as containing large vessels, whereas in ROIs corresponding to microvascular environment average DeltaT(2)* values are 0.8 +/- 0.1 ms.

Brain↗

High-resolution MR venography at 3.0 Tesla.

PURPOSE: The aim of this study was to investigate the visualization of small venous vessels in the normal human brain at a field strength of 3 Tesla. METHODS: T2*-weighted, three-dimensional gradient-echo images were acquired by exploiting the magnetic susceptibility difference between oxygenated and deoxygenated hemoglobin in the vasculature and microvasculature. The spatial resolution was 0.5 x 0.5 x 1 mm3, and sequence parameters were varied to obtain good vessel delineation. Improved visibility of venous vessels was obtained by creating phase mask images from the magnetic resonance phase images and multiplying these by the magnitude images. Venograms were created by performing a minimum intensity projection over targeted volumes. RESULTS: Highly detailed visualization of venous structures deep in the brain and in the superficial cortical areas were obtained without administration of an exogenous contrast agent; compared with similar studies performed at 1.5 T, the echo time could be reduced from typically 40-50 ms to 17-28 ms. CONCLUSION: Imaging at high-field strength offers the possibility of improved resolution and the delineation of smaller vessels compared with lower field strengths.

Adult↗