[Verification of normative values for the Swiss version of the Freiburg speech intelligibility test].

BACKGROUND AND OBJECTIVE: In the Swiss version of the Freiburg speech intelligibility test five test words from the original German recording which are rarely used in Switzerland have been exchanged. Furthermore, differences in the transfer functions between headphone and loudspeaker presentation are not taken into account during calibration. New settings for the levels of the individual test words in the recommended recording and small changes in calibration procedures led us to make a verification of the currently used normative values. PATIENTS AND METHODS: Speech intelligibility was measured in 20 subjects with normal hearing using monosyllabic words and numbers via headphones and loudspeakers. RESULTS: On average, 50% speech intelligibility was reached at levels which were 7.5 dB lower under free-field conditions than for headphone presentation. The average difference between numbers and monosyllabic words was found to be 9.6 dB, which is considerably lower than the 14 dB of the current normative curves. CONCLUSIONS: There is a good agreement between our measurements and the normative values for tests using monosyllabic words and headphones, but not for numbers or free-field measurements.

Adult↗

[Tinnitus].

Tinnitus is an auditory perception without adequate external acoustic sources. The incidence of tinnitus in the general population is high, and can lead to total decompensation in some of the affected patients. Tinnitus is a symptom of an unspecific lesion of the ear or the central auditory system. In many cases, the cause of tinnitus can be inferred from the medical history and from the results of specific medical examines. Nevertheless, in many cases there is still no causal therapy available. As a result, for most patients approaches such as proper counselling, the fitting of hearing aids or tinnitus retraining therapy are adopted.

Audiometry↗

[New developments in hearing aid technology].

The last decade has seen numerous and significant improvements in hearing aid technology. Digital hearing aids are becoming increasingly common and have already replaced a considerable portion of the hearing aids using the older analogue technology. Efficient noise reduction methods, most notably multi-microphone systems for hearing aids, can increase speech intelligibility in adverse listening situations and noisy environments. Accessories, such as e.g. wireless classroom communication systems (FM systems) and remote controls are becoming smaller and less visible. As a consequence of the increased complexity of modern hearing aids, however, hearing aid fitting has become considerably more complex.

Acoustics↗

[Bone anchored hearing aids (B.A.H.A.)].

Semi-implantable bone conduction hearing aids of the type Bone Anchored Hearing Aids (B.A.H.A.) consist of an external vibrator hearing aid that is attached to a titanium screw implanted in the mastoideal bone behind the ear by means of a transcutaneous connector. In this way sound waves are transmitted directly to the bones of the skull, from where they are conducted to the cochlea. The primary indication for a semi-implantable bone conduction hearing aid is hearing loss due to conduction failure that is not surgically correctable. This may be caused, e.g. by ear canal atresia and other malformations of the external auditory meatus and of the middle ear, by chronic ear infections or by persistent high grade conduction hearing impairment after radical mastoidectomy. Today B.A.H.A.'s largely replace the less convenient conventional bone conducting hearing aids as hearing glasses or hearing bands, in which a vibrator is pressed against the skull. In conduction hearing impairment on both ears B.A.H.A.'s can be implanted bilaterally and thus binaural hearing with sound source localisation are made possible. A novel application is in cases of unilateral deafness, where the device is implanted on the side of the deaf ear and the amplified sounds are transmitted through the skull to the side of the hearing ear. Here it serves as a substitute for a CROS hearing aid. In adults the implantation is performed under local anesthesia as an out-patient procedure. Implantation may be undertaken under general anesthesia on children after two years of age. In Berne, B.A.H.A. bone conduction hearing aids have been implanted in 112 patients (ages 2-82 years) in the past 13 years. The operations have proved simple and without intra-operative complications. The long-term post-operative incidence of complications was low. The transcutaneous screw caused only isolated cases of transient skin reactions or local infections. In 7% of cases, rejection of the implant or a traumatic loosening of the screw required a reimplantation procedure. Over 90% of patients reported themselves satisfied with their partially-implantable B.A.H.A. hearing aids.

Adolescent↗

[The cochlear implant--evolution of hearing and language with an artificial inner ear].

One of the most spectacular progresses in modern medicine is the possibility to replace a deaf ear, a sensory organ in total by an implantable electronic prosthesis, a so-called cochlear implant (CI). The CI stimulates the auditory nerve by electrical pulses and thus generates the sensation of hearing along the auditory pathway. One of the most impressive aspects of cochlear implantation is the fact that small children with profound deafness who were able a few years ago to learn spoken language only to very limited extent may achieve nowadays an almost normal language development. Duration and intensity of the training of listening and spoken language vary considerably as a function of etiology and time of deafness. Most important for the development of language is sufficient stimulation of the auditory pathway during early childhood. Early diagnosis of a severe to profound deafness is most important in order to fit hearing aids or a cochlear implant without a time delay. Affected children need intensive training by professionals specialized in education and speech therapy. Adults and adolescents who lost their hearing when language acquisition was established may understand spoken language only a few weeks after receiving a cochlear implant. Several individuals are able to use the telephone. Preliminary results after bilateral cochlear implantation of children and adults show advantages. Not only do these subjects report "better hearing with two CI as compared to hearing with one CI," but some of them developed directional hearing in a rather short time lag after fitting the second implant. And in addition they achieve better speech discrimination in environmental noise.

Adolescent↗

Vestibular function in patients with cochlear implantation.

The aim of this work was to determine the influence of cochlear implantation (CI) on vestibular canal and otolithic function. Between 1995 and 1999, 15 patients (6 females, 9 males; 9-77 years old) underwent a vestibular examination before and after CI. Electronystagmography was performed between 5 and 8 days after CI in 9 patients, and with a time delay of 2-24 months in 10 patients. Pre- and postoperative evaluation included electronystagmography with caloric (44 degrees C, 30 degrees C, ice-water) and pendular rotatory testing. Otolithic function was measured postoperatively using off-vertical axis rotation (OVAR) in six patients. Preoperative data (n = 14) showed areflexia on caloric and rotatory pendular testing in deafness cases due to meningitis (n = 2) and in 2/5 patients with sudden idiopathic bilateral deafness. Two patients suffering from an idiopathic deafness had a unilateral hyporeflexia. Vestibular function was normal in the other eight patients. Immediately following CI, among patients with normal preoperative canal function, three developed vertiginous symptoms with spontaneous nystagmus, which disappeared within days to weeks. Later, postoperative canal evaluation was normal in 5/8 patients (62%) with initially preserved vestibular function: areflexia was measured ipsilaterally to the implanted ear in 1 patient and contralaterally in 2 patients. Hyporeflexia was measured ipsilateral to the implanted ear in two patients. OVAR examination, performed 2-19 months after surgery, showed a preserved otolithic function in all 6 tested patients. Transient vertigo on electrical CI stimulation was described in only one patient during the first postoperative weeks. The following conclusions can be drawn. Patients with deafness due to meningitis had an eradicated vestibular function. In other etiologies, vestibular function was most often preserved. CI did not usually abolish vestibular function, but the canal function was disturbed temporarily in 20% of cases. Otolithic function was preserved in all six CI patients tested in this series.

Adolescent↗

Performance of an adaptive beamforming noise reduction scheme for hearing aid applications. I. Prediction of the signal-to-noise-ratio improvement.

Adaptive beamformers have been proposed as noise reduction schemes for conventional hearing aids and cochlear implants. A method to predict the amount of noise reduction that can be achieved by a two-microphone adaptive beamformer is presented. The prediction is based on a model of the acoustic environment in which the presence of one acoustic target-signal source and one acoustic noise source in a reverberant enclosure is assumed. The acoustic field is sampled using two omnidirectional microphones mounted close to the ears of a user. The model takes eleven different parameters into account, including reverberation time and size of the room, directionality of the acoustic sources, and design parameters of the beamformer itself, including length of the adaptive filter and delay in the target signal path. An approximation to predict the achievable signal-to-noise improvement based on the model is presented. Potential applications as well as limitations of the proposed prediction method are discussed and a FORTRAN subroutine to predict the achievable signal-to-noise improvement is provided. Experimental verification of the predictions is provided in a companion paper [J. Acoust. Soc. Am. 109, 1134 (2001)].

Acoustics↗

Performance of an adaptive beamforming noise reduction scheme for hearing aid applications. II. Experimental verification of the predictions.

A method to predict the amount of noise reduction which can be achieved using a two-microphone adaptive beamforming noise reduction system for hearing aids [J. Acoust. Soc. Am. 109, 1123 (2001)] is verified experimentally. 34 experiments are performed in real environments and 58 in simulated environments and the results are compared to the predictions. In all experiments, one noise source and one target signal source are present. Starting from a setting in a moderately reverberant room (reverberation time 0.42 s, volume 34 m3, distance between listener and either sound source 1 m, length of the adaptive filter 25 ms), eight different parameters of the acoustical environment and three different design parameters of the adaptive beamformer were systematically varied. For those experiments, in which the direct-to-reverberant ratios of the noise signal is +3 dB or less, the difference between the predicted and the measured improvement in signal-to-noise ratio (SNR) is -0.21+/-0.59 dB for real environments and -0.25+/-0.51 dB for simulated environments (average +/- standard deviation). At higher direct-to-reverberant ratios, SNR improvement is systematically underestimated by up to 5.34 dB. The parameters with the greatest influence on the performance of the adaptive beamformer have been found to be the direct-to-reverberant ratio of the noise source, the reverberation time of the acoustic environment, and the length of the adaptive filter.

Acoustics↗

Acoustic imaging of the human chest.

STUDY OBJECTIVES: A novel method for acoustic imaging of the human respiratory system is proposed and evaluated. DESIGN: The proposed imaging system uses simultaneous multisensor recordings of thoracic sounds from the chest wall, and digital, computer-based postprocessing. Computer simulations and recordings from a life-size gelatin model of the human thorax are used to evaluate the system in vitro. Spatial representations of thoracic sounds from 8-microphone and 16-microphone recordings from five subjects (four healthy male adults and one child with lung consolidation) are used to evaluate the system in vivo. RESULTS: Results of the in vitro studies show that sound sources can be imaged to within 2 cm, and that the proposed algorithm is reasonably robust with respect to changes in the assumed sound speed within the imaged volume. The images from recordings from the healthy volunteers show distinct patterns for inspiratory breath sounds, expiratory breath sounds, and heart sounds that are consistent with the assumed origin of the respective sounds. Specifically, the images support the concept that inspiratory sounds are produced predominantly in the periphery of the lung while expiratory sounds are generated more centrally. Acoustic images from the subject with lung consolidation differ substantially from the images of the healthy subjects, and localize the abnormality. CONCLUSIONS: Acoustic imaging offers new perspectives to explore the acoustic properties of the respiratory system and thereby reveal structural and functional properties for diagnostic purposes.

Adult↗

A novel real-time noise reduction system for the assessment of evoked otoacoustic emissions.

A novel noise reduction method and apparatus to be used in connection with the measurement of evoked otoacoustic emissions (EOAE) are presented. The noise reduction method is based on an adaptive noise canceller and requires a noise-only reference microphone placed in the vicinity of the OAE-probe. The method was implemented in real time on a custom built digital signal processing system using an Analog Devices ADSP-2181 digital signal processor. The system interfaces seamlessly with a commercial EOAE acquisition system. Results of a series of experiments show than noise reductions of 7-8 dB can be reached.

Acoustic Stimulation↗

Electromagnetic interference of bone-anchored hearing aids by cellular phones.

We report a case of electromagnetic interference between a bone-anchored hearing aid (BAHA) and a cellular phone. A 54-year-old women was successfully treated for severe mixed conductive and sensorineural hearing loss with a BAHA. Five years after implantation, the patient experienced a sudden feeling of dizziness, accompanied by a loud buzzing sound and by a sensation of head pressure while examining a digital mobile phone. During a subsequent experiment, the buzzing sound could be reproduced and was identified as electromagnetic interference between the BAHA and digital cellular phones. Seventeen adult BAHA users from our clinic participated in a subsequent survey. Of the 13 patients with some experience of digital cellular phones, 11 reported hearing annoying noises elicited by these devices. However, no other sensation, such as dizziness, was described. Owing to the increasing number of users of both hearing aids and cellular phones, the incidence of electromagnetic interference must be expected to increase as well. Although to date there is no evidence that such interference may be harmful or dangerous to users of conventional or bone-anchored hearing aids, unexpected interference can be a frightening experience.

Electromagnetic Fields↗

Performance of compressed analogue (CA) and continuous interleaved sampling (CIS) coding strategies for cochlear implants in quiet and noise.

Speech understanding with compressed analogue (CA) and continuous interleaved sampling (CIS) coding strategies for cochlear implants was compared in quiet and in noise at signal-to-noise ratios (SNRs) of 15, 10 and 5 dB. The speech recognition of three experienced users of the Ineraid cochlear implant (CA coding strategy) was assessed using a set of sentence, vowel and consonant tests. Three weeks after the fitting of a CIS processor, the tests were repeated with the new device. Speech recognition scores for the sentence and consonant tests tended to be higher with the CIS processor in no or little noise, but lower in the test situations with less favourable SNRs, when compared to the CA processor (average score differences for the consonant test: +7.8% correct at 15 dB SNR; -6.8% correct at 5 dB SNR; p = 0.05). Results for the vowel test were slightly lower on average for the CIS processing strategy at all SNRs. A possible explanation for the differences in performance between CIS and CA in the consonant and sentence tests at different SNRs is the generally higher free-field threshold associated with the CA coding strategy, which may act as a single-channel noise suppression.

Adolescent↗

Effects of breathing pathways on tracheal sound spectral features.

The spectra of sounds recorded over the trachea of adults typically reveal peaks near 700 and 1500 Hz. We assessed the anatomical determinants of these peaks and the conditions contributing to their presence. We studied five adult subjects with normal lung function, measuring sounds at the suprasternal notch and on the right cheek. The subjects breathed at target airflows of 15 and at 30 ml sec(-1) kg(-1) both through the mouth with nose clips and then through the mouth and nose using a cushioned face mask. The mouth breathing maneuvers were performed with three lengths (3.6, 21.1 and 38.6 cm) of 2.6 cm diameter tubing between the mouth and the pneumotachograph. The nose breathing maneuver was performed with the longest tube (between the mask and pneumotachograph). The signals occurring at the target flows +/- 20% were used to create averaged, spectral estimates. We found that all subjects had two predominant spectral peaks; a approximately 700 Hz peak loudest over the cheek and a approximately 1500 Hz peak loudest over the trachea. The frequency of both peaks negatively correlated with body height (and presumably, airway length). There was no systematic effect of breathing phase, flow rate or length of the tube connecting the mouth to the pneumotachograph on the spectral peaks. Breathing into the mask and breathing through the nose did markedly alter the spectra. We conclude that the higher tracheal sound peak reflects resonance within the major airways and is relatively independent of extrathoracic influences during mouth breathing through a tube.

Adult↗

Computer-based lung sound simulation.

An algorithm for the simulation of normal and pathological lung sounds is developed. The simulation algorithm is implemented on a personal computer as well as on a digital signal processor system in real time. Normal, bronchial and tracheal breathing sounds can be generated, and continuous and discontinuous adventitious lung sounds can be added. The attributes of the individual sound components, such as loudness, frequency, duration or number of occurrences within one breathing cycle, are controlled by the user. The quality of the simulations is evaluated by sending audio tapes to 15 experienced pulmonary physicians for a formal assessment. Each tape contains five simulated lung sounds and five real lung sounds from a commercially available teaching tape, presented in random order. Simulated lung sounds are slightly better rated in terms of realism and signal quality when compared to the recordings from the teaching tape. The differences are, however, not significant. 13 out of the 15 physicians feel that computer-based lung sound simulators would be a useful and desirable teaching tool for auscultation courses.

Algorithms↗

Digital signal processing (DSP) applications for multiband loudness correction digital hearing aids and cochlear implants.

Single-chip digital signal processors (DSPs) allow the flexible implementation of a large variety of speech analysis, synthesis, and processing algorithms for the hearing impaired. A series of experiments was carried out to optimize parameters of the adaptive beamformer noise reduction algorithm and to evaluate its performance in realistic environments with normal-hearing and hearing-impaired subjects. An experimental DSP system has been used to implement a multiband loudness correction (MLC) algorithm for a digital hearing aid. Speech tests in quiet and noise with 13 users of conventional hearing aids demonstrated significant improvements in discrimination scores with the MLC algorithm. Various speech coding strategies for cochlear implants were implemented in real time on a DSP laboratory speech processor. Improved speech discrimination performance was achieved with high-rate stimulation. Hybrid strategies incorporating speech feature detectors and complex decision algorithms are currently being investigated.

Adult↗

Comparison of the TEMPO+ ear-level speech processor and the cis pro+ body-worn processor in adult MED-EL cochlear implant users.

A study was conducted to compare the new MED-EL TEMPO+ ear-level speech processor with the CIS PRO+ body-worn processor in the COMBI 40/COMBI 40+ implant system. Speech tests were performed in 46 experienced subjects in two test sessions approximately 4 weeks apart. Subjects were switched over from the CIS PRO+ to the TEMPO+ in the first session and used only the TEMPO+ in the time between the two sessions. Speech tests included monosyllabic word tests and sentence tests via the telephone. An adaptive noise method was used to adjust each subject's scores to approximately 50%. Additionally, subjects had to complete a questionnaire based on their 4 weeks of experience with the TEMPO+. The speech test results showed a statistically significant improvement in the monosyllabic word scores with the TEMPO+. In addition, in the second session, subjects showed a significant improvement when using the telephone with the TEMPO+, indicating some learning in this task. In the questionnaire, the vast majority of subjects found that the TEMPO+ allows equal or better speech understanding and rated the sound quality of the TEMPO+ higher. All these objective and subjective results indicate the superiority of the TEMPO+ and are mainly attributed to a new coding strategy called CIS+ and its implementation in the TEMPO+. In other words, based on the results of this study, it appears that after switching over from the CIS PRO+ to the TEMPO+, subjects are able to maintain or even improve their own speech understanding capability.

Adult↗