PubMed Health⌕ Search

Biomedical subjects

M Krachler

Publications and source records attributed to M Krachler.

27 records · Page 2Linked to original sources

Optimized procedure for the determination of antimony in lipid-rich environmental matrices by flow injection hydride generation atomic absorption spectrometry.

An analytical procedure for the reliable determination of Sb in digests of lipid-rich environmental matrices in the low ng l-1-range based on flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS) has been developed. Prior to HG-AAS, aliquots (250 to 320 mg) of dry samples were mineralized with 3 ml nitric acid and 0.5 ml of each sulfuric and perchloric acids in open digestion vessels made of glassy carbon in a heating block. Procedure detection and quantification limits of a previously developed procedure for the determination of Sb in plant materials by FI-HG-AAS were decreased with respect to the lower Sb concentrations in animal tissues, the sensitivity of the instrumental response was increased, and the composition of the acid digestion mixture was re-optimized for lipid-rich samples. The accuracy and precision of the developed procedure was evaluated by the analysis of the two reference materials Bovine Liver 1577a and Pig Kidney CRM 186. These reference materials have been additionally spiked with appropriate amounts of Sb to obtain recovery data. The solution detection limit (3 sigma) in digested samples was 0.021 microgram l-1, the detection limit for the whole procedure based on the dry powders was 7 pg g-1, the method quantification limit for a reliable determination of Sb was 23 pg g-1. The reproducibility of repetitive measurements was 6.0% at 0.1 microgram Sb l-1 and 2.2% at 0.5 microgram Sb l-1. Calibration curves were linear from 0.05 to 3 micrograms Sb l-1. To demonstrate the suitability of the developed method, concentrations of Sb have been determined in pigeon eggs (approximately 2 ng Sb g-1), as well as in bream livers (approximately 4 ng g-1) and in deer livers (approximately 5 to 8 ng g-1) from animals living in remote and urban-industrialized areas of Germany, respectively.

Animals↗

Biomonitoring of antimony in environmental matrices from terrestrial and limnic ecosystems.

Elder and poplar leaves from various sampling sites were studied with respect to their antimony content. Moreover, a retrospective determination of Sb was performed in representative limnic and terrestrial samples of the Federal Environmental Specimen Bank of Germany which have been collected over 14 years. The analytical procedure is based on an open vessel acid digestion of freeze-dried biological samples and the subsequent quantification of Sb in the digests by flow injection hydride generation atomic absorption spectrometry. Strict quality control schemes were applied to the entire procedure to guarantee accurate and precise results. No long-term changes of the Sb concentrations were found in spruce shoots or poplar leaves from different sampling sites. However, spruce shoots from a semi-natural region showed concentrations of Sb (approximately 22 ng g-1; range: 17-29 ng g-1) that were approximately four times lower than in corresponding samples from an urban-industrialized area. The analysis of virgin and washed elder leaves revealed that approximately 20-30% of the Sb is present on the leaf surface. Sb levels in elder leaves ranged from 5.2 +/- 0.3 ng g-1 in samples from Argentina to 589 +/- 30 ng g-1 in leaves collected directly beside a motorway in Germany. Similarly, poplar leaves from Argentina and Chile showed about 4 ng Sb g-1, whereas 150 ng Sb g-1 was found in poplar leaves from Germany. The lowest concentrations of Sb were determined in digests of pigeon eggs (approximately 2 ng g-1), bream liver (approximately 4 ng g-1) and deer liver (approximately 6 ng g-1). A similar pattern of Sb concentrations in spruce shoots, leaves or liver samples from an industrialized area and an agrarian ecosystem in Germany was established. Concentrations of Sb in elder leaves were closely associated with car traffic, giving maximum concentrations of 589 ng g-1 directly beside a motorway, 207 ng g-1 50 m from the motorway and 153 ng g-1 in a close residential area.

Agriculture↗

Exchange of alkali trace elements in hemodialysis Patients: a comparison with Na(+) and K(+).

BACKGROUND: In the past, nephrologists have been troubled by electrolyte disturbances and consequently focused their attention on the importance of maintaining the concentrations of electrolytes within the normal range. However, information about the potential role of trace elements in chronic renal failure is scarce. METHODS: During hemodialysis sessions, the concentrations of the five alkali metal cations lithium (Li), sodium (Na), potassium (K), rubidium (Rb), and cesium (Cs) have been determined in plasma and dialysis fluids of chronic hemodialysis patients by inductively coupled plasma mass spectrometry (Li, Rb, Cs) and by ion-sensitive electrodes (Na, K). Strict quality control schemes were applied to all analytical procedures to ensure accuracy and precision of the results. RESULTS: The plasma concentrations of the elements Li, Cs, Rb, and K distinctly decreased to 29, 50, 69, and 71%, respectively, of their initial values during hemodialysis. Simultaneously, the concentrations of these elements in dialysis fluids at the outlet of the dialyzer increased approximately 13-fold for Rb, 11-fold for Li, 3-fold for Cs, and 2-fold for K as compared with the inlet values. The concentrations of Na in plasma and dialysis fluids were almost identical and did not change during hemodialysis. CONCLUSIONS: Li, Rb, and Cs were depleted in hemodialysis patients, although the plasma concentrations of these trace elements still remained within the reference ranges for healthy adults. Consequently, further studies are needed to elucidate the clinical importance and long-term effects of these trace element imbalances - for example, CNS disturbances associated with diminished concentrations of Rb - in hemodialysis patients.

Adult↗

Trace elements in formulas based on cow and soy milk and in Austrian cow milk determined by inductively coupled plasma mass spectrometry.

With inductively coupled plasma-mass spectrometry (ICP-MS), the 18 trace elements Ba, (Be), (Bi), Cd, Co, Cs, Cu, La, Li, Mn, Mo, Pb, Rb, (Sb), (Sn), Sr, (Tl), and Zn were quantified in the digests of 13 formulas based on cow milk, of two formulas based on soy protein, of two milk powders, from which formulas were prepared, of two samples of Austrian cow milk, and in the water, with which the powders were suspended. Concentrations in parentheses were at or below the method detection limits in the formulas. The accuracy and precision of the analytical procedure tested with milk powder reference materials BCR 063 and BCR 150 were satisfactory. The concentrations of trace elements in the powders vary considerably from batch to batch. The ratios of high to low concentrations ranged from 1.1 to 4.8 and were higher for the essential trace elements Co, Cu, Mn, Mo, Sn, and Zn than for nonessential or toxic elements. The contribution of tap water from the water system of the city of Graz, Austria to the concentrations of trace elements in the formulas ranges from 45% for Pb to 0.2% for Rb and is negligible, for instance, for Cd, Cs, La, Mo, and Sn. Preformulas and follow-up formulas are partly supplemented with the essential trace elements Cu, Mn, and Zn and, therefore, concentrations of these trace elements in the formulas vary considerably. However, supplementation of a formula with a particular element must not necessarily result in higher concentrations compared to non-supplemented formulas. Concentrations of the essential elements were in the following ranges for preformulas, follow-up formulas, soy-based formulas (in microg/kg): Co, 8.3-11.2, 4.5-13, 5.0-5.7; Cu, 330-750, 27-730, 440-530; Mn, 33-580, 40-390, 440-530; Mo, 10-32, 9-39, 44-46; Sn, <0.44-3.8, <0.44-1.0, <0.44-5.8; Zn, 3340-11,380, 4120-7100, 5590-6,840. A preformula supplemented with Mn had a 10 times higher manganese concentration than preformulas without supplementation. Concentrations of all trace elements quantified were lower in cow milk than in formulas and do not meet the dietary requirements of infants.

Animals↗

Changes in the concentrations of trace elements in human milk during lactation.

Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine 18 trace elements (Ba, Be, Bi, Cd, Co, Cs, Cu, La, Li, Mn, Mo, Pb, Rb, Sb, Sn, Sr, Tl, and Zn) in 55 human milk samples from 46 healthy mothers collected during lactation periods extending to 293 days after birth. Se was quantified by hydride generation atomic absorption spectrometry (HG-AAS). To test the accuracy and the precision of the analytical procedure, milk powder reference materials (BCR 063 and BCR 150) were analyzed. The results obtained by ICP-MS and HG-AAS showed good agreement with the certified values. Whenever available, trace element concentrations determined in the human milk samples were compared to reliable literature data. The concentrations of Be (< 0.05 to 0.9 microgram/kg), Bi (< 0.09 to 2.0 micrograms/kg), Cs (1.7 to 7.7 micrograms/kg), La (< 0.05 to 3.7 micrograms/kg), Rb (440 to 1,620 micrograms/kg), and Tl (< 0.08 to 0.5 microgram/kg) are the first to be reported for human milk. The concentrations of the essential trace elements Cu (p < 0.005), Mn (p < 0.05), Mo (p < 0.0005), Se (p < 0.001), and Zn (p < 0.0005) significantly decreased and the concentrations of cobalt significantly increased (p < 0.005) in human milk during the course of lactation. All concentrations for the essential trace element tin in the human milk samples were below the method detection limit of 0.3 microgram/kg. Among the not essential and toxic elements-with the exception of Ba, Pb, and Tl-the trend toward lower concentrations with continuing lactation is much less pronounced than for the essential trace elements. With the exception of Se, the daily intakes of essential trace elements of fully breast-fed infants are considerably lower than dietary recommendations.

Female↗

Trace elements in coronary heart disease: Impact of intensified lifestyle modification.

Concentrations of 14 trace elements (Bi, Cd, Co, Cs, Cu, Hg, Mn, Pb, Rb, Sb, Sn, Sr, Tl, and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS) in 120 whole-blood and 121 plasma samples of 56 patients with angiographically documented coronary heart disease (CHD). One serum and two whole-blood reference materials were analyzed for quality control. At baseline, patients had elevated Co plasma as well as diminished Cu blood concentrations compared to healthy adults. The Zn concentrations in whole blood were below or at the lower end of the normal range, but the concentrations in plasma were elevated. All other trace elements were within the normal concentration ranges for healthy adults. After initial investigations, patients were randomly assigned to an experimental group (N = 27) and to a usual care group (N = 29). Experimental group patients were prescribed a lifestyle program that included a low-fat diet and a weekly moderate exercise. Patients were examined at baseline, after 6 and 12 mo for clinical assessment and fasting venous blood samples. No significant time-course changes in concentrations of trace elements in blood and plasma during the clinical treatment in both groups of patients could be observed. The experimental group patients lost weight and had lower blood pressure after 12 mo compared to baseline. The interventional therapy reduced the need for further revascularization procedures.

Aged↗

Trace element status of hemodialyzed patients.

The trace elements Ba, Bi, Cd, Co, Cs, Cu, Hg, La, Mn, Mo, Pb, Rb, Sb, Sn, Sr, Tl, and Zn were determined by inductively coupled plasma mass spectrometry in plasma samples of 68 hemodialysis patients. The same elements (with exception of La and Mn) were also determined in whole blood after mineralization with high-purity nitric acid/hydrogen peroxide in a closed-pressurized microwave system. The accuracy and precision was checked by analyzing two Seronorm "whole blood" reference materials. All samples were contaminated with barium (heparinized tubes) and the plasma samples with tin (collection tubes). The concentrations for Bi, Hg, Pb, Rb, Sb, and Sr in whole blood were within the literature ranges for healthy adults. All of the concentrations for Co, and some of the concentrations for Cd, Cs, Tl, and Zn were higher than the high limits of the normal ranges. Approximately 14% of the Cu concentrations were lower than the low limit of the normal range. The Mo and Sn concentrations are difficult to evaluate, because the normal ranges appears to be unreliable. All concentrations for Cd, Co, Mo, Pb, Sn, and Sr and some of the concentrations for Cu (15%) and Mn (75%) in the plasma samples were higher than the high limits of the normal ranges. The concentrations for Rb tended to be lower than the normal range. To establish unequivocally the causes for elevated and reduced concentrations of trace elements in whole blood and plasma of dialysis patients, all fluids in the dialysis process must be investigated.

Adult↗

Trace elements in pleural effusions.

When the secretion of pleural fluids exceeds their resorption, liquid (pleural effusion ) will accumulate between the visceral and parietal pleura. Pleural effusions derived from the liquid components of blood are expected to contain trace elements and may, as a sink for trace elements, deprive the body of needed essential elements upon their removal by medical intervention. Consequently, patients may be at risk of drifting into trace-element deficiencies. Because the literature is almost devoid of data about trace elements in effusions, the concentrations of 14 trace elements (Ba, Ca, Cd, Co, Cs, Cu, Mg, Mn, Mo, Pb, Rb, Sn, Sr, Zn) were determined simultaneously by inductively-coupled argon-plasma mass spectrometry (ICP-MS) in effusions from 17 patients. The median values for the concentrations of Rb (209 microgram/kg, range 104-334 microgram/kg) and Cs (1.5 micrograms/kg, range 0.8-2.4 microgram/kg) in the effusions were almost the same as in the sera. The concentrations of Mg (range 15-22 mg/kg), Ca range 52-91 mg/kg), Sr (range 12-37 micrograms/kg), and Ba (range 1.4-18.2 micrograms/kg) were consistently lower in the effusions than in the sera by 18% for Mg, 26% Ca 14% for Sr, and 88% for Ba (percentages based on median in serum as 100%). The concentrations of the essential trace elements Co (range 0.16-0.5 microgram/kg), Cu (130-902 micrograms/kg), Mn (0.2-2.2 micrograms/kg), Mo (0.4-1.5 micrograms/kg), Sn (0.4-1.2 micrograms/kg), and Zn (27-1931 micrograms/kg) in the effusions are generally lower (25-55% based on median) than in the corresponding sera, although a few effusions have higher concentrations of Co, Mn Mo, or Zn than in the sera. The concentrations of Cd (range 0.2-0.5 microgram/kg) in the effusions were approximately the same as in the sera for three patients, considerably lower than in the sera for four patients, and considerably higher for three patients. The concentrations for lead (range 0.6-45 micrograms/kg) in the effusions were generally much higher than in the sera. The effusions were not significantly contaminated with lead-rich erythrocytes. The concentrations of Ca, Cu, and Zn in the effusions correlated positively with the protein concentrations in the effusions. One kilogram of the effusions contain from 10-30% of the trace elements present in the entire volume of serum in circulation.

Adult↗

Microwave digestion methods for the determination of trace elements in brain and liver samples by inductively coupled plasma mass spectrometry.

Two microwave digestion systems (open-focused and closed-pressurized) were tested for the mineralization of human brain and bovine liver (NIST SRM 1577a) as dissolution steps prior to the determination of 16 trace elements (Bi, Cd, Co, Cs, Cu, Fe, Hg, Mn, Mo, Pb, Rb, Sb, Sn, Sr, Tl, and Zn) by inductively coupled plasma mass spectrometry (ICP-MS). Digestion parameters (mass of sample, digestion mixture, and power/time steps) were optimized using temperature and pressure sensors. Digestions with the open-focused microwave system require larger volumes of conc. HNO(3) and 30% H(2)O(2) than digestions with the closed-pressurized system. Both systems produce correct results for the bovine liver samples. The concentrations obtained for the digests of the open-focused system tend to be less precise than the concentrations from the "closed-pressurized" digests. Because the "open-focused" digests must be diluted to 50 mL to bring the acid concentration to 0.7-2.0 mol/L required by the ICP-MS (closed-pressurized digests need to be diluted to only 20 mL), the detection limits for the system with the open-focused digestion are higher than for the system with the closed-pressurized digestor. The open-focused digestor cannot handle more than 150 mg brain tissue, whereas the closed-pressurized system can mineralize 470 mg. The latter method gave better results with brain tissue than the open-focused system. The preparation of brain tissue as reference material for the determination of trace elements in brain samples is described.

Journal Article↗